• Title/Summary/Keyword: 고도처리공정

Search Result 269, Processing Time 0.021 seconds

Estimation of Kinetic Coefficient in Submerged Membrane Bioreactor for Biological Nutrient Removal (도시 하수의 생물학적 고도처리를 위한 분리막 공정의 개발 및 동역학적 계수 산정 연구)

  • Park, Jong-Bu;Park, Seung-Kook;Hur, Hyung-Woo;Kang, Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.109-113
    • /
    • 2009
  • This study was performed to investigate the characteristics of nutrient removal of municipal wastewater in membrane bioreactor system. Membrane bioreactor consists of four reactors such as the anaerobic, the stabilization, the anoxic and the submerged membrane aerobic reactor with two internal recycles. The hydraulic retention time (HRT), sludge retention time (SRT) and flux were 6.2 h, 34.1 days and 19.6 L/$m^2$/hr (LMH), respectively. The removal efficiency of $COD_{Cr}$, SS, TN and TP were 94.3%, 99.9%, 69.4%, and 74.6%, respectively. The estimated true biomass yield, specific denitrification rate (SDNR), specific nitrification rate (SNR), specific phosphorus release rate (SPRR) and specific phosphorus uptake rate (SPUR) were 0.653 kgVSS/kgBOD/d, 0.044 $mgNO_3$-N/mgVSS/d, 0.035 $mgNH_4$-N/mgVSS/d, 51.0 mgP/gVSS/d and 5.4 mgP/gVSS/d, respectively. The contents of nitrogen and phosphorus of biomass were 8.86% and 3.5% on an average.

Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System (한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성)

  • Jae-Lim Lim;Lee, Kyung-Hyuk;Kim, Seong-Su;Chae, Seon-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.

Study on solubilization of sewage sludge using electrolysis techniques (전기분해에 의한 하수슬러지 가용 효과 연구)

  • Lee, Ji-Sun;Chang, In-Soung;Lee, Chul-Ku;Joung, Seun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.979-984
    • /
    • 2011
  • Although sludge production has been increased due to the number of the wastewater treatment plants expanded, needs of the techniques for the sludge reduction and disposal has been issued importantly because the sludge dumping to ocean is prohibited from 2012 by the London Dumping Convention. Therefore, the sludge solubilization using electrolysis as an alternative techniques for the sludge disposal was carried out in this study. Iridium coated titanium based insoluble electrodes were used and 20 volt was applied to the electrolysis reactor using DC power supply. Supernatants of the treated sludge was monitored: The soluble COD, TN, TP of it was increased to 151%, 22% and 6% respectively. And the sludge floc size distribution was changed, that is, the flocs ranged from 0.1 to 1.0 ${\mu}m$ were increased. All of these results indicate that the cells were lysed and the internal matters bursted out of the cell after electrolysis. As well as the reduction of the sludge production, the soluble organic matters from the cells could be used as an external carbon sources in the advanced wastewater treatment plants.

Effect of Wet Milling on Scum Generation and Solubilization in Batch Ozone Reaction Using Digested Sludge (소화슬러지를 이용한 회분식 오존반응 시 습식분쇄가 스컴 생성과 가용화에 미치는 영향)

  • Hong, Seong-Min;Lee, Dong-Hoon;Kim, Choong-Gon;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.13-18
    • /
    • 2019
  • Sewage sludge treatment is increasing every year due to improvement of living and urbanization. However, interest in anaerobic digestion which is one of the recycling technology. There is anaerobic digestion of increasing due to limitations of ocean dumping and final disposal. But, the limit of anaerobic digestion efficiency due to the advanced treatment of sewage has been limited, and studies for solubilization technology have been actively conducted. Therefore, in this study, we aimed to investigate the variation of generation of scum and the solubilization efficiency in the application of pre-treatment of ozone reaction and the change of properties of digested sludge with wet milling. There are results of VS/TS increased by 4.4% and $SCOD_{cr}/TCOD_{cr}$ increased by 9.4% by wet milling alone. In addition, the increase of the specific surface area due to which the reduction of the particle size of the solid content of the sludge in the ozone reaction caused by wet milling decreased the generation rate of scum at 14.3% and increased VS/TS at 2.1%, compared with the ozone reaction alone. From these results, it is expected that the application of wet milling can be increased the contact efficiency with solids in the sludge during ozone reaction with suppress scum and increase the efficiency of the subsequent process in anaerobic digestion.

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.

The Removal of Organics and Nitrogen with Step Feed Ratio Change into the Anoxic and Anaerobic reactor in Advanced Sewage Treatment process Using Nonsurface-modified and Surface-modified Media Biofilm (비개질/개질 생물막을 이용한 오수고도처리공정에서 혐기조와 무산소조의 원수 분배율에 따른 유기물 및 질소 제거)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.20 no.4
    • /
    • pp.253-259
    • /
    • 2005
  • This study was accomplished using attached $A^2/O$ process that contains nonsurface-modified and surface-modified polyethylene media inside the Anaerobic/Anoxic, Oxic tank, respectively. We could make the hydrophobic polyethylene media have hydrophilic characteristics by radiating ion beam on the surface of the media. The objectives of this study is to investigate the removal efficiencies of the organics and nitrogen when the step feed ratio of raw wastewater into anaerobic and anoxic tank is changed. In this case, we assumed that the denitrification rate can be improved because the nitrifiers in anoxic tank can perform denitrification using RBDCOD instead of artificial carbon sources (for example, methanol, etc.). The wastewater injection rate into anaerobic/anoxic tank was set up by the ratio of 10 : 0, 9 : 1, 8 : 2, 6 : 4, and the results of BOD removal efficiency showed similar trends with $93.3\%,\;92.6\%,\;92.4\%\;and\;91.6\%$, respectively. But the BOD removal efficiency (utilization of the organics) in the anoxic tank was in the order of 9 : 1 $(84.8\%)$, 10 : 0 $(77.0\%)$, 8 : 2 $(75.3\%)$, and 6 : 4 $(61.1\%)$. The T-N removal efficiency was most high when the ratio is 9 : 1 $(67.4\%)$, and other conditions, 10 : 0, 8 : 2, 6 : 4, showed $61.3(\%),\;60.7\%,\;55.5\%$, respectively; the ratio 6 : 4 was found to be lowest T-N removal efficiency, lower than the ratio 9 : 1 by $12\%$. Though the nitrification rate of the ratio 10 : 0, 9 : 1, and 8 : 2 showed similar levels, the ratio 6 : 4 showed considerable inhibition of nitrification, ammonia was the great portion of the effluent T-N. The advantages of this process is that this process is cost-saving, and non-toxic methods than injecting the artificial carbon source.

Distribution and Risk Assessment of Bisphenol-A in Tap Water from Rehabilitated Indoor Water Service Pipe (갱생 옥내급수관 수돗물에서 비스페놀-A 분포 및 위해성 평가)

  • Jeong, Gwanjo;Son, Boyoung;Lee, Inja;Ahn, Chihwa;Kim, Junil;Moon, Boram;Lee, Suwon;Ahn, Jaechan;Kim, Bogsoon;Chung, Deukmo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.371-376
    • /
    • 2016
  • In this study, the survey of bisphenol-A in indoor water service pipes rehabilitated with epoxy resin was conducted and the risk assessment was done to investigate the effect on the human health to drink tap water. Bisphenol-A in raw water was detected in a range of 50~118 ng/L in all samples, where the limit of quantification was 10 ng/L. This is caused by inflow of the sewage effluent or the tributaries of the surrounding area containing bisphenol-A. Bisphenol-A was not detected in finished water after the advanced water treatment process. It was achieved by its removal from the processes of flocculation-precipitation and oxidation of ozone and chlorine and by being changed to other by-product materials. For the indoor water service pipe, bisphenol-A was not detected in all cases which was not coated with epoxy resin. However, when epoxy resin is lined within the indoor water service pipe, bisphenol-A was identified at maximum level of 521 ng/L and was detected above the limit of quantitation at 68 percentages of all samples. The Hazard Quotient (HQ) at the maximum level (521 ng/L) of the detected bisphenol-A is 0.004, which is less than the reference value of 0.1 for the tap water intake. Therefore, it is considered that the detected levels of bisphenol-A in this study would be safe to drink tap water.

The Study on Optimum Operation Conditions of Ceramic MF Membrane Process in Y Water Treatment Plant (Y 정수장 세라믹막 여과공정 최적 운영인자 평가)

  • You, Sang-Jun;Ahn, Hyo-Won;Park, Sung-Han;Lim, Jae-Lim;Hong, Sung-Chul;Yi, Pyong-In
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.201-212
    • /
    • 2014
  • This study was performed to discover the optimum operation conditions for the advanced water treatment using the ceramic membrane, introduced the first in the nation at the Y water treatment plant (WTP). The result of investigation to find the optimum operation conditions which can continue preserving the filtration performance as well as satisfying both the economics and the water quality is as follows. In the ordinary water quality condition of the Y WTP, the optimum filtration time(the backwash period), which can minimize the production of backwash waste and preserve the membrane performance was examined to be 4.0 hours on basis of institution capacity ($16,000m^3/day$). Examining the recovery rate of TMP from the chemical cleaning (CIP) discovered that the inorganic contaminants, which cause membrane fouling, such as iron, manganese, aluminum, were removed through the acidic cleaning using citric acid, whereas the membrane recovery rate was found to be low. But, on the other hand, the TMP was recovered to the initial value from the alkali cleaning using the NaOCl. Therefore, the main contaminant causing the fouling was determined to be hydrophilic organic compound( biopolymer). The membrane recovery rate is highly influenced by the temperature of the cleaning chemical. That is, the rate increased with increasing temperature.

A Study of Use of Auto Rigging Tool To Increase Effectiveness of 3D Animation Production (3D애니메이션제작의 효율성 향상을 위한 오토 리깅 툴의 활용에 대한 연구)

  • Baek, Jong-Yeol
    • Cartoon and Animation Studies
    • /
    • s.49
    • /
    • pp.247-265
    • /
    • 2017
  • With the increasingly diverse, sophisticated and complex character animations that can be represented in 3D animations, the importance of rigging, which can most directly affect animating quality, is becoming more and more important. In addition, rapidity is another crucial aspect of 3D animation production. So, the importance of technical director's role which is accurate and rapid handling of rigging pipeline building and immediate application and, corrections of errors during the longest and manpower consuming animation production is more becoming key. Baek Ji Won and Kim Jae-woong (2014) said, "The technical director is adding new importance to the new job, which is created by 3D animation, in conjunction with the limited production period, manpower, budget and production process." Most major overseas studios are developing in-house software to handle rigging and animation processes. Software development code is used to freely develop and modify production pipelines in accordance with the direction of the work. They are making efforts to build an optimal environment for animators. However, too many efforts and ineffective efforts have been made to develop, adapt, and stabilize the rigging process for small producers, creators, and students who do not have the capacity to develop their own in-house software or hire a technical director. This study suggests the most suitable auto-rigging tool among the many auto-rigging tools released in the market, and suggests the most accurate and quick auto-rigging process setting method for those who have insufficient knowledge about 3D character rigging. The efficiency of use of auto-rigging tool was examined.

Degradation Characteristics of Non-degradable Dye in Aqueous Solution by Ozonation (고도산화공정인 오존처리에 의한 난분해성 염료 수용액의 분해특성)

  • Hwang, Se-Wook;Park, Jong-Hwan;Lee, Su-Lim;Eom, Ju-Hyun;Ryu, Sung-Ki;Choi, Ik-Won;Kim, Seong-Heon;Kang, Se-Won;Cho, Ju-Sik;Seo, Dong-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.1
    • /
    • pp.58-64
    • /
    • 2020
  • BACKGROUND: Most of the researches on the dye removal using ozonation have been focused on the removal efficiency. However, the research on their removal characteristics and mechanism according to the reaction time has been still insufficient. METHODS AND RESULTS: In this study, the effects of initial pH and dye concentration with reaction time on the degradation characteristics of methyl orange (MO) and methylene blue (MB) by ozonation were evaluated. The degradation efficiency of MB by ozonation increased with increasing pH. On the other hand, the degradation efficiency of MO by ozonation did not show a significant difference with varing pH. The both MO and MB by ozonation were decomposed within 30 min irrespective of the dye concentration, but the decomposition rates of dyes were faster at lower initial dye concentration. The decomposition efficiency of total organic carbon (TOC) in each dye solution by ozonation was low, which was found to be effective for partial decomposition such as decolorization rather than complete degradation of the dye. CONCLUSION: Overall, ozonation was an effective method for removing nondegradable dyes. However, it is necessary to study the optimization of dye degradation under various environmental conditions for ozonation.