• Title/Summary/Keyword: 고관절 인공관절 전치환술

Search Result 8, Processing Time 0.023 seconds

Saddle Prosthesis (안장형 인공 고관절 전치환술)

  • Park, I.H.;Ihn, J.C.;Lee, J.M.
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.133-144
    • /
    • 1995
  • After resection of intraarticular, periacetabulum(P2) and pubic rami(P23) and extraarticular, proximal femur(P2-H12) by Enneking classification, reconstruction is very difficult. We experienced three cases of saddle prostheses for reconstruction after P2, P23, and P2-H12 resection in pelvic malignancies. Case 1 was a high grade chondrosarcoma in 36 year-old-man and P2 resection was done. But he died of disease 19 months after operation. Case 2 was a malignant giant cell tumor in 32 year-old-woman. P23 resection was given and she is disease-free 32 months after operation. Case 3 was an osteosarcoma of 27-year-old-man and P2-H12 resection was performed and he is disease-free postoperative 12 months now. According to MSTS functional evaluatin system, all three patients showed no pain(5), intermediate function(2), emotinally satisfied(3), one cane or crutch supported(1), limited walking(3), and minor cosmetic gait(3). There was no significant complication and no dislocation except intermittent inguinal hernia in case 2. All patients started crutch walking 3 weeks after operation. Around 6 months postoperatively, the preserved iliac wing(P1 component) was hypertrophied enough to endure the full weight bearing. All could have squating and kneeling positions. In conclusion, saddle prosthesis would be a very useful method of reconstruction after P2, P23, and/or H1-2 resection to shorten the operation time and to reduce the infection rate without significant loss of function.

  • PDF

The Comparison of Bonded/Unbonded Stem-Cement Interface in Total Hip Replacement -Experimental Study (인공 고관절 전치환술에서 주대-시멘트 경계층의 접착 및 비접착 고정술의 비교를 위한 실험적 연구)

  • Han, J.H.;Yoon, Y.S.;Lee, J.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.951-955
    • /
    • 2001
  • The experimental comparison between bonded and unbonded types stem-cement interface was carried out on axisymmetric stem-cement-aluminum model of the femoral component of a total hip replacement. Human femur was modeled in non-tapered and tapered($7.5^{\circ}$) aluminum hollow cylinders to emulate the diaphyseal and metaphyseal segments of the femur. For unbonded type, we tested stems with three different taper angles($5^{\circ},\;7.5^{\circ},\;10^{\circ}$). In every case, the cement-aluminum interface was designed to endure 8MPa shear strength. (a measured value at cement-bone interface) We tested aluminum models under axial loading for both cases. As an experimental result, it was found that unbonded stem sustained more axial load as bonded stem in both cases, diaphyseal and metaphyseal models. The unbonded types failed in cement mantle under axial compressive load, while the bonded ones failed in shear at cement-aluminum interface. These results suggest that a polished stem will sustain much higher axial load than a roughened stem. And a polished stem will make more stable cement-bone interface that may promote better osteosythesis around the stem.

  • PDF

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.

Wear and Implantation Tilt Measurements using X-ray and CAD (X-ray영상과 CAD를 이용한 인공고관절의 마모 및 식립각 측정법)

  • Lee, Jong Min;Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2018
  • Long-term complications such as loosening, wear, osteolytic lesion and granulomatous reaction by foreign bodies can occur, after total hip arthroplasty. The implantation alignment effects dislocation and wear, according to its amount and direction. Wear particles in total hip arthroplasty brings about biochemical complications such as osteolysis or send wear. In this sense, it is important to regularly check wear and alignment of total hip replacement. Because the wear in followup of 10 years may remain in a small amount, like a 1 or 2 mm generally, somewhat precise measurement tool has to be established. The wear and alignment measurement softwares commercially available currently lack in project saving or reproducibility. This study suggests a reliable method for the measurement using an X-ray image and a CAD software. The proposed method can be executed only if having a CAD software under most of current general clinical radiographical environment. The proposed was revealed through tests for the method to have accuracy of 0.06 mm with precision of 0.05 mm for wear measurement, and precision of 0.27 degrees for tilt measurement.

Effects of Structured Exercise Program on Hip Pain, Physical Function and Quality of Life in Patients with Total Hip Arthroplasty (구조화된 운동 프로그램이 인공고관절 전치환술 환자의 고관절 통증, 신체기능 및 삶의 질에 미치는 효과)

  • Kwon, Eunhee;Lee, Haejung;Lee, Sunghwa
    • Journal of muscle and joint health
    • /
    • v.25 no.2
    • /
    • pp.122-134
    • /
    • 2018
  • Purpose: The purpose of this study was to develop a 12-week structured exercise program (12-week-SEP) and evaluate its effects on pain, physical function and quality of life in patients with total hip arthroplasty (THA). Methods: A nonequivalent control group non-synchronized design was utilized to examine the effects of the 12-week-SEP on patients' outcomes after THA. A total of 46 adult patients (experimental group=25, control group=21) who had THA were recruited for the study. The 12-week-SEP consisted of education, exercise (muscle strengthening and progressive walking), and feedback. Data were analyzed by SPSS/WIN 21.0 using the $x^2$ test and repeated measures ANOVA. Results: The mean age of the participants was 60.9 years and 25 men (54.5%) and 21 women (45.7%) were included in the study. There were significant intervention effects on pain reduction and increased physical function but no effects on quality of life. Conclusion: The 12-week-SEP provided pain relief and enhanced physical function in patients underwent THA. Clinical application of the 12-week-SEP can improve postoperative nursing practices for patients with THA. Future research with larger sample is of necessity to obtain greater generalizability of the empirical evidences of the 12-week-SEP.

Behavior Analysis of the Treated Femur and Design of Composite Hip Prosthesis (대퇴부 거동 해석 및 복합재료 보철물 설계)

  • 임종완;하성규
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.119-130
    • /
    • 2002
  • The nonlinear finite element program has been developed to analyze the design performance of an artificial hip prosthesis and long term behavior of a treated femur with stems made of composite material after cementless total hip arthroplasty(THA). The authors developed the three dimentional FEM models of femoral bone with designed composite stem which was taken with elliptic cross section of 816 brick elements under hip contact load and muscle farce in simulating single leg stand. Using the program, density changes, stress distributions and micromotions of the material femoral bone were evaluated by changing fiber orientation of stems for selected manufacturing method such as plate cut and bend mold. The results showed that the composite materials such as AS4/PEEK and T300/976 gave less bone resorption than the metallic material such as cobalt chrome alloy, titanium alloy and stainless steal. It was found that increasing the long term stability of the prosthesis in the femur could be obtained by selecting the appropriate ply orientation and stacking sequence of composite.

Comparative Study of Compliance for Venous Thromboembolism Prophylaxis (American College of Chest Physicians Guideline and American College of Orthopedic Surgeons Guideline) in High Risk Patients with a Venous Thromboembolism (정맥혈전 색전증 고위험군에서 시행한 혈전색전 예방요법(American College of Chest Physicians 지침 및 American College of Orthopedic Surgeons 지침)의 준수율 비교 연구)

  • Suh, You-Sung;Nho, Jae-Hwi;Jang, Byung-Woong;Kang, Deokwon;Won, Sung-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.317-326
    • /
    • 2019
  • Purpose: To compare and analyze the rate of prevention of two venous thromboembolism prophylaxis guidelines in patients with artificial joint arthroplasty and hip joint fracture. Proper prophylaxis for preventing thromboembolism in orthopedic surgery is significant because of this fetal complication. Materials and Methods: This study compared and retrospective analyzed the rate of prevention using the medical records and radiographs of patients who underwent orthopedic surgery from March 2009 to February 2011 according to the American College of Chest Physicians (ACCP) guidelines and from March 2012 to February 2014 according to the American Academy of Orthopedic Surgeons (AAOS) guidelines. Results: The guidelines for venous thromboembolism prophylaxis have been applied to patients with artificial joint replacement and hip joint fracture, the compliance rate of the ACCP guidelines was 56.0% before surgery, 67.0% after surgery with chemical prophylaxis, and 80.5% with mechanical prophylaxis. In addition, the compliance rate of the AAOS guidelines was 74.1% with chemical prophylaxis, and 88.3% with mechanical prophylaxis, which was higher than the ACCP guidelines. The compliance rates of mechanical and chemical prophylaxis before and after surgery of the ACCP guidelines, and the compliance rate of mechanical and chemical prophylaxis of the AAOS guidelines were compared and analyzed. The results revealed statistical significance (p<0.05) before and after total knee replacement arthroplasty and hip joint fracture internal fixation and total high risk orthopedic surgery. Conclusion: Raising the compliance rate of prophylaxis of venous thromboembolism in high risk orthopedic surgery is necessary and people should follow the guidelines for a unified direction depending on which situation they are in.