• Title/Summary/Keyword: 고강도 그라우트

Search Result 28, Processing Time 0.035 seconds

Characteristics Strength of Silicasol-cement Grout Material for Ground Reinforcement (지반보강용 실리카졸 약액의 강도특성에 대한 연구)

  • Kim, Hyunki;Kim, Younghun;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.9
    • /
    • pp.47-53
    • /
    • 2010
  • This study was made on the fact that the compressive strength characteristic of the recently developed alkali silica-sol chemical grout material was examined, whose grout material used for this study was designed to understand its strength property through the uniaxial compressive strength test(homo-gel, sand-gel), permeability test, deflection strength test, etc. In order to compare with the engineering characteristics regarding alkali silica-sol grout material and sodium silicate grout material. The uniaxial compressive strength of silica-sol grout material was identified to be increased more than 3~5 times than sodium silicate grout material at the early stage(within 72 hours). When comparing with the uniaxial compressive strengths of Sand-gel and Homo-gel at the material age of 28 days in case of silica-sol grouting material the strength of Sand-gel was measured to be about 1.3 times higher than Homo-gel. In case of silica-sol, it is assumed to have the property to exert high strength when it is actually grouted into the ground. As a result of permeability test it is judged that it is possible to apply the silica-sol to the site in the place requiring the water cut-off as the silica-sol. As a result of testing the strength at the material age of 28 days of grouting-use silica-sol showed more than 3 times' difference than the sodium silicate grouting material.

Engineering Properties of Composite Silicate Grout Materials (합성실리카 그라우트재의 공학적 특성)

  • 천병식;양형칠
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.1
    • /
    • pp.163-172
    • /
    • 2003
  • The engineering properties of composite silicate grout materials that were developed recently were analyzed. In this laboratory tests, OPC (Ordinary Portland Cement) was mainly used as grout materials. Moreover, the properties of composite silica, silica sol and sodium silicate (No.3) acting as coagulating agent were analyzed and compared with each other. For the purpose of finding the engineering properties of composite silicate grout materials, various physical and chemical tests were performed : naked eye measurement, photographing by using SEM, uniaxial compression test and in-situ application test. A series of test results showed that the strength of composite silicate grout materials was about 3~6 times that of ordinary sodium silicate grout materials in 6~24hr. Especially, based on the evaluation of the application of JS-CGM grout to the construction fields, composite silicate grout would be very effective in reducing the coefficient of permeability.

Anti-washout Grouts for Underwater Sealing of Karst Cavities and Construction Research Tendencies (수중 불분리성 그라우트 개발 기술 동향)

  • Baluch, Khaqan;Kim, Jung-Gyu;Kim, Jong-Gwan;Yu, Ji-Yun;Yang, Hyung-Sik
    • Explosives and Blasting
    • /
    • v.38 no.4
    • /
    • pp.46-52
    • /
    • 2020
  • Although anti-washout grouts are used extensively in underwater targets, major constraints continue to be associated with their use. These include poor bonding strength, poor pumpability, and loss of high strength in everyday engineering applications. In this study, based on the literature pertaining to self-compacted, non-dispersive, anti-washout grouts, a review of research trends in anti-washout grouts for underwater construction and sealing of karst cavities was carried out in order to determine the problems faced in this field. Grouts used under water suffer a loss of strength and bonding strength in comparison to grouts cast in air. Researchers are designing high-viscosity grouts to overcome the inrush of water and seal karst cavities; however, in doing so, they have inadvertently caused serious problems pertaining to the pumpability of these grouts and concretes in deep target locations. Thus, the majority of the anti-washout grouts and concretes that have been developed are not applicable to deep target environments, instead being suitable for only near-surface targets.

Monitoring of calcium aluminate grout exposed to sea water environment (해수에 노출된 칼슘 알루미나계 그라우트의 기계적 특성 모니터링)

  • Son, Dasom;Jiyoon, Park;Chongku Yi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.183-184
    • /
    • 2023
  • Considering the actual marine environment construction, this paper monitors the mechanical properties (Flexural, Compressive strength) by exposing alumina cement to seawater. As a result of the experiment, it was confirmed that the strength decreases by about -25% when curing in seawater, but the target strength of the product is met, so it is believed that exposure to the actual marine environment will not be significantly affected.

  • PDF

An Experimental Study on the Bonding Characteristic of Steel Tubular Joint Connection filled with Fiber Reinforced High Performance Cementeous Grout (섬유보강 고성능시멘트계 그라우트가 적용된 강관 연결부의 부착특성에 대한 실험적 연구)

  • Oh, Hong-Seob;Seo, Gyo;Kim, Sang-Hyeon;Ko, Sang-Jin;Lee, Hyeon-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.21-29
    • /
    • 2014
  • This paper deals with the bonding characteristic of grouted joint connections of monopile support structures for offshore wind power facilities. For the integration of pile connection of wind power supporting structure, fiber reinforced high performance cementeous grout was developed and the ultimate compressive strength of it is 125MPa and the direct tensile strength is 7.5 MPa at 7 days. To assess the bond strength of grout filled in pile connection, small scaled direct bond tests under axially loaded was performed and analyzed according the existing guidelines. The fiber volume fraction (0%, 0.5% and 0.9%), aspect ratio of fiber (60 and 80) and the ratio of height to spacing of shear key (0.013 and 0.056) were adopted as the experimental variables. From the test results, the maximum bond strength among the all specimens was 30.8MPa and the bond strength of grouted connection was affected by the ratio of height to spacing of shear key than the fiber volume fraction.

The Effect of PC-Based SP on Rheology and Strength of High Strength Grout (PC계 유동화제가 고강도 그라우트에 유동성 및 강도에 미치는 영향)

  • Kim, Beomhwi;Yi, Chongku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.148-149
    • /
    • 2022
  • The use of high-strength grout applied for facility foundations and bridges has recently been expanding in offshore wind farm. Wind farm in offshore require bearing capacity for horizontal loads such as wind, waves, and earthquakes. In order to improve the bearing force of the base part, sufficient fluidity and a certain strength should be ensured so that the high-strength grout is densely charged in the narrow space of the connection part. Therefore, in this study, changes in fluidity and strength according to the ratio of PC-based superplasticizer mixed in high-strength grout were measured. As a result, as the ratio of the superplasticizer increased, fluidity increased and strength decreased. However, the strength did not decrease when the ratio of superplasticizer was above a 0.005. Therefore, it was confirmed that the fluidity change was remarkable when a 0.005 ratio of PC-based superplasticizer were added.

  • PDF

Effect of Underwater Pumping on the Strength of High-Strength Grout (수중펌프압송이 고강도 그라우트의 강도에 미치는 영향)

  • Kim, Beom-Hwi;Yi, Chong-Ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.193-194
    • /
    • 2022
  • The use of high-strength grout for facility foundations and bridges has recently been expanding in offshore wind farms. Offshore wind farms require a bearing capacity for horizontal loads such as wind, waves. Therefore, in this study, the strength of the high-strength grout discharged through pump pressure was measured and compared with the existing strength to secure the strength after the underwater pump pressure of the high-strength grout used in the offshore wind connection. The compressive strength measurement showed that the strength difference at each position of the core specimen was 1% higher than that of the other specimens, and there was almost no change in the strength according to the height. The strength of the core specimen decreased by 23% compared to the existing strength, which is similar to the result of this study because the strength of the core specimen decreased by approximately 25% compared to the general specimen according to related research. Therefore, it is believed that there is no decrease in strength due to underwater pumping.

  • PDF

Characteristics of High-viscosity Grouting Materials for Rock Joint Reinforcement of Deep Tunnel (대심도 터널 암반 절리 보강을 위한 고점도 그라우팅 재료의 특성)

  • Yoon, Inkook;Moon, Junho;Lee, Junsu;Kim, Younguk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.59-63
    • /
    • 2021
  • This study presented the characteristics and additive effects of the grout with mixing ratio for developing of high-efficiency grouting technology under high depth conditions. The laboratory investigation were conducted with Portland cement (OPC) and micro cement (S8000-E) including viscosity experiments, particle size analysis experiments, Gel-Time experiments and uniaxial compressive strength experiments. As a result of the viscosity experiment, it was shown that OPC is advantageous in terms of viscosity, but S8000-E is suitable when considering the passage of rock joint intervals through particle size analysis. The Gel-Time experiment shows that it is not that difficult with injection as a grout material even when silica fume (SF) was applied. The strength of the cured material is improved as increase in the content of silica fium (SF). Within the range of the study, the optimal mixing ratio obtained through various experiments is S8000-E, w/c=70%, silica fium (SF)=6%, and 7 days.