• Title/Summary/Keyword: 계산기관

Search Result 477, Processing Time 0.025 seconds

Automatic Segmentation of Pulmonary Structures using Gray-level Information of Chest CT Images (흉부 CT 영상의 밝기값 정보를 사용한 폐구조물 자동 분할)

  • Yim, Ye-Ny;Hong, Helen
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.11
    • /
    • pp.942-952
    • /
    • 2006
  • We propose an automatic segmentation method for identifying pulmonary structures using gray-level information of chest CT images. Our method consists of following five steps. First, to segment pulmonary structures based on the difference of gray-level value, we select the threshold using optimal thresholding. Second, we separate the thorax from the background air and then the lungs and airways from the thorax by applying the inverse operation of 2D region growing in chest CT images. To eliminate non-pulmonary structures which has similar intensities with the lungs, we use 3D connected component labeling. Third, we segment the trachea and left and right mainstem bronchi using 3D branch-based region growing in chest CT images. Fourth, we can obtain accurate lung boundaries by subtracting the result of third step from the result of second step. Finally, we select the threshold in accordance with histogram analysis and then segment radio-dense pulmonary vessels by applying gray-level thresholding to the result of the second step. To evaluate the accuracy of proposed method, we make a visual inspection of segmentation result of lungs, airways and pulmonary vessels. We compare the result of the conventional region growing with the result of proposed 3D branch-based region growing. Experimental results show that our proposed method extracts lung boundaries, airways, and pulmonary vessels automatically and accurately.

Comparison of Farm Based Fertilizer Usage in 1992 and 1999 (1992년과 1999년의 농가 비료이용 실태 변화 비교)

  • Kim, Seok-Cheol;Park, Yang-Ho;Lee, Youn;Lee, Ju-Young;Kim, Chung-Su;Kim, Pil-Joo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.5
    • /
    • pp.344-355
    • /
    • 2003
  • Korea is one of those countries that have very high usage rates of chemical fertilizers per unit area of cropland. To reduce the fertilizer application rate, a variety of agricultural polices has been introduced since the 1990s. In this study, fertilizer usage was surveyed on the farm base throughout the country in 1999, and the data were compared with those of 1992. Organic fertilizer application rates were decreased in most cereal crops with time pass, but maintained similar levels in vegetables grown in plastic-film houses and in upland soils. Chemical fertilizer application rates were decreased in most of the cereal crops and vegetables surveyed; however, this reduction was concentrated in phosphate and potassium usage, but not in nitrogen. In spite of this decrease, the fertilizer application levels to most crops were maintained at levels much higher than recommended. In the nutrient balance, which was calculated from the difference between input (chemical and organic fertilizers) and output (agricultural products), the nitrogen nutrient surplus did not decrease; however, phosphate and potassium decreased by 21% and 13%, respectively, in 1999 compared with 1992. To reduce fertilizer utilization and to conserve environment, further reduction of fertilizer application is essential.

Analysis of Change Transitions in Regional Types in Emergency Department Patient Flows of in Jeonlado (2014-2018) (전라지역 응급실 환자의 유출입 분석 및 지역유형 변화 추이)

  • Lee, Jae-Hyeon;Lee, Sung-Min;Kim, Seongjung;Oh, Mi-Ra
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.12
    • /
    • pp.126-131
    • /
    • 2020
  • This study analyzed the inflow and outflow patterns of emergency department patients, to identify changes in regional types in cities, counties, and districts in Jeonlado, Korea. Data of areas in Jeonlado for 2014 to 2018 were extracted from the National Emergency Department Information System. The extracted data includes the patients' and emergency medical institution addresses, which were used to calculate the relevance index (RI) and commitment index (CI). The calculated indices were classified into regional types by applying cluster analysis. A non-parametric method, Kruskal-Wallis test, was employed to examine the differences between years for RI and CI by regional types. The results of cluster analysis using the relevance and commitment indices revealed three regional types. Regions in cluster 1 were classified as outflow type, in cluster 2 as inflow type, and in cluster 3 as self-sufficient. RI and CI were calculated for each cluster or regional type. There were no significant differences between years in cluster 2 (inflow type) and cluster 3 (self-sufficient type). In cluster 1 (outflow type), there were no significant differences in CI between the years; however, there were significant differences in RI between 2014 and 2017, and 2014 and 2018. It is difficult to see that the emergency medical environment has improved due to the increased concentration of emergency medical care.

Effects of Dry Matter Content of Liquid Swine Manure on Dry Matter Yield and Nutritive Value of Italian Ryegrass, Rye and Oat, and the Chemical Characteristics of Soil in Jeju (제주지역에서 건물 함량이 다른 돈분 액비 시용이 이탈리안 라이그라스, 호밀 및 귀리의 수량, 사료가치 및 토양 특성에 미치는 영향)

  • Song, Sang-Taek;Kim, Moon-Chul;Hwang, Kyoung-Jun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.26 no.3
    • /
    • pp.159-170
    • /
    • 2006
  • This study was conducted to investigate the effects of two dry matter levels of liquid swine manure on dry matter yield and nutritive value of Italian ryegrass, rye and oats, and the chemical characteristics of soil in Jeju. This experiment tested in split plot design. Three forage crops (Italian ryegrass, rye and oats) were the main plot and four fertilizers (no fertilizer=T0, chemical fertilizer=T1, liquid swine manure with DM 2.7%=T2 and liquid swine manure with DM 5.9 %=T3) were the sub plots. Yield and nutrient contents of forage crops and soil properties were determined. Application of liquid swine manure containing 5.9% dry matter resulted in highest DM yield in all three forage crops species compared with the other treatments (p<0.01). Crude protein content(%) and crude protein yield(kg/ha) of forage crops were highest in rye compared with the other forage crops species(p<0.01). K and Mg contents of soil were higher(p<0.01) in rye than in the other species while Na contents was higher(p<0.01) in Italian ryegrass than others. Mg content of soil appeared higher in rye than in the others and higher(p<0.05) in forage crops applied with liquid manure containing 2.7% DM compared with the other species. $NO_3-N$ contents in soil was lower in rye than the other species and higher in species with chemical fertilizer. These findings indicate that most of liquid swine manure produced on local pig farms containing low levels of dry matter and other nutrients suggest a low efficiency of its use as a fertilizer. The liquid swine manure is recommended as a fertilizer for rye production in winter, compared with Italian ryegrass or oat.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Preparation of Polystyrene Beads by Suspension Polymerization with Hydrophobic Silica as a Stabilizer in Aqueous Solution (소수성 실리카를 안정제로 이용하는 수용액 상에서의 현탁중합법에 의한 폴리스티렌 입자 합성)

  • Park, Moon-Soo
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.498-504
    • /
    • 2006
  • A suspension polymerization of styrene In aqueous phase was employed to study if polystyrene particles ranging from 1 to $20{\mu}m$ can be produced. Hydrophobic silica was selected as a stabilizer and azo-bisisobutyronitrile (AIBN) as an initiator. Polymerization reaction was carried out at a selected temperature in the range of $65{\sim}95^{\circ}C$. Stabilizer concentration was varied from 0.17 to 3.33 wt% compared to the water while the concentration of the initiator was raised from 0.13 to 6.0 wt% compared to the monomer. Dispersion of hydrophobic silica into the water phase was achieved by precise control of pH. Optimum dispersion of silica was obtained at pH 10. Average particle diameter decreased with increasing amounts of stabilizer concentration initially, exhibiting the minimum average diameter at 1.67 wt% of stabilizer concentration, after which it started to Increase. It is speculated that an excessive presence of stabilizer encouraged a secondary reaction in the reaction medium, which led to particle agglomeration, and as a result an increase in average particle diameter. Molecular weight was found to be independent of stabilizer concentration between 0.13 and 1.00 wt% whereas, it increased when stabilizer concentration exceeded 1.67 wt%. Variation of molecular weight was probably caused by the reduced activity and efficiency of initiator due to the high concentration of silica, and the secondary reaction in the reaction medium, as well. An increase in the Initiator concentration and/or reaction temperature resulted in an increase in both reaction rate and particle diameter. Consequently, we have confirmed that spherical polystyrene particles with $1{\sim}20{\mu}m$ in diameter can be prepared by careful selection of the concentration of stabilizer, initiator, pH and reaction temperature.

Calculating the Audit Fee Based on the Estimated Cost (예정원가계산에 의한 감사보수 산정)

  • Mun, Tae-Hyoung
    • Management & Information Systems Review
    • /
    • v.35 no.1
    • /
    • pp.189-206
    • /
    • 2016
  • It was required to attach the documents on the details of external audit including the number of the participants in external audit, audited parts and audit times under the Article 7-2 on the audit report to the accounting audit report from 2014 in accordance with the amendment to the Act on External Audit of Stock Companies. This study aim to calculate the audit fee based on the estimated cost of service calculation of the government contribution agencies by reflecting the implementation of the revised external audit. This study calculated the audit fee for the target company (a listed company assumed to have no internal control risks and relevant audit risks for unqualified opinion in the previous year, 100 billion won of total amount of asset, manufacturing company in the previous year and preliminary client request) by putting together four items of expenditure including employment costs, expenditure, general management expenses and profit in accordance with the calculation system of cost of service under the State Contract Act. Then, it used the data collected from the documents on the details of the revised external audit after requesting estimation on the target company with the estimated cost to Big-4 accounting firms to identify the participants and times of the accounting audit. The employment costs applied 150% of participation rate of the base price of employment costs for the academic research service cost in 2014, the expenditure used the average value of accounting firms of corporate business management analysis of the Bank of Korea (2013), the general management expenses applied 5% of the general management rate of service business under Article 7-1 of the Enforcement Rule of the Act on Contracts to which the State is a Party and the profit applied 10% of profit rate of service business under Article 7-2 of the Enforcement Rule of the Act on Contracts to which the State is a Party. Based on the calculation of the estimated costs by applying the above, the audit fee was estimated at 50,617,769won. Although the result is not the optimal audit fee, it may be used as a basic scale to compare the audit fees of companies without criteria. Also, such amendment to the Act on External Audit of Stock Companies may improve independence of auditors and transparency of the accounting system rather than previous announcing only the total audit times.

  • PDF

A Case Study on the Hospital Information Systems Usability (병원정보시스템 사용성에 대한 실증연구)

  • Park, Chan-Seok;Lee, Hyen-Uoo;Koh, Seok-Ha
    • Information Systems Review
    • /
    • v.10 no.3
    • /
    • pp.289-311
    • /
    • 2008
  • This study is a development of quality scale and a measurement of quality levels for the Hospital Information System(HIS) used in the hospital industry. This study is to provide decision-making guidelines for hospital managers, system analysts, and software designers, and to provide feedback for the users' information needs. The target people of the study were medical doctors, nurses, pharmacists, and clerical staff. The service contexts of usability were diagnosis/treatment, nursing, medicine preparation, and treatment fee receipt/claim. The quality factors were the efficiency, effectiveness, and satisfaction of IS09241-11. This study shows that the current domestic HISs are mostly based on patient diagnosis/treatment and treatment fee accounting, and that other quality scales are necessary according to different job categories, specializations, positions, and service domains. Especially, the low quality of HIS was found in the abnormal service processing, information sharing by outside institutions, and standardization. It may be added that the HIS should be improved and developed in these respects.

The Development of Low Cost Power Components Measurement and Record System for Monitoring Electrical Equipment Operation Status (전력설비 동작 상태 감시를 위한 저가형 전력 성분 측정 및 기록 시스템의 개발)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4855-4862
    • /
    • 2015
  • This paper proposes low price power component measurement and record system for preventing electrical safety accident and supporting accident cause analysis by periodically monitoring and recording the operation status of electrical equipments. The proposed system was designed by mainly using parts to measure accurate power component but reduce cost. Especially, low cost and high effectiveness system implementation was possible by using MAXIM 78M6631 to calculate power components in the definition of IEEE Standard 1459-2010 related power quality. The measurement performance of the developed system is tested by using standard devices such as YOKOGAWA power analyzer WT1600. The test results showed that accuracy of the developed system is less than 0.5 % and the developed system is tested in a real area to verify the operation reliability and remote monitoring performance of the system over 6 months.

Optimal Network Design for Enhancing the Precision of National Geodetic Network (국가 측지망의 정밀도 향상을 위한 최적 측지망 설계에 관한 연구)

  • Cho, Jae-Myoung;Yun, Hong-Sik;Wie, Gwang-Jae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.6
    • /
    • pp.587-594
    • /
    • 2010
  • This paper describe the optimal design of geodetic network by analytical technique based on the quality criteria of network. We described an example of geodetic network design taking into account the precision, reliability and robustness that are the main criteria of network design. The main goal of this paper is to evaluate the criteria to design the geodetic network coinciding with the criteria of high precision(error ellipse, 2DRMS, CEP), reliability(internal and external reliability) and robustness(maximum shear strain, principal strain, dilatation). The network design parameters computed in this study show that precision and reliability has not much improved by about 2% and 3%, respectively, than the observed network, while robustness has much improved by about 3, 100%. It also shown that maximum errors of precision, reliability and robustness were reduced by 5%, 7% and 16,957%, respectively.