• Title/Summary/Keyword: 경화층깊이

Search Result 30, Processing Time 0.023 seconds

Nondestructive Measurement of Case Hardening Depth with Eddy Current Method (와전류법을 이용한 강의 표면경화층 깊이의 비파괴적 측정)

  • Lee, K.W.;Han, S.Y.;Park, U.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.1
    • /
    • pp.38-43
    • /
    • 1991
  • The relationship between eddy current response and case hardening depth has been studied on SM40C(KS D-3752) and SCM440(KS D-3711) steels which were surface hardened by high frequency induction hardening. The results obtained in this study were as follows ; 1) Case hardening depth was successfully measured by observing the eddy current impedance changes of each steel. The impedance decreased linearly with increasing case hardening depth. 2) For large impedance gradient between the hardened surface and core metal, the eddy current response was more sensitive to case hardening depth than for low impedance gradient.

  • PDF

Water Transport Characteristics of Paddy Plow Pan Soils as Estimated by Particle Size Distribution Fractal Dimension (토양입자분포 프랙탈차원을 활용한 논토양 쟁기바닥층 물이동 추정)

  • Han, Kyung-Hwa;Cho, Hyun-Jun;Hur, Seung-Oh;Ha, Sang-Geun;Cho, Hee-Rae;Jeon, Sang-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • This study was carried out to investigate plow pan characteristics and to grasp the relationship between its particle size distribution fractal dimension ($D_m$) and water transport in paddy plow pan. Twenty four soil sampling sites with different management groups, ordinary and sandy-textured, were selected and investigated for physical properties of soils such as Yamanaka hardness in April, non-submerged condition, before rice seedling transplanting. The plow pan appearing depth and thickness was determined by penetration resistance profile. Undisturbed core samples with five replicates were sampled at plow pan layerwith 2 inch cores for measuring soil bulk density and saturated hydraulic conductivity. The particle size distribution fractal dimension ($D_m$) was calculated by the method following the procedure Tylerand Wheacraft (1992), using the USDA-based particle size analysis datawith fractions of 0-0.002, 0.002-0.053, 0.053-0.1, 0.1-0.25, 0.25-0.5, 0.5-1.0, and 1.0-2.0 mm. The plow pan of investigated fields appeared at a range from 5 to 30 cm depth, showing minimum value in sandy-textured management group and maximum value in ordinary management group. The thickness of plow pan were distributed from 5 to 17 cm, showing both minimum and maximum values in sandy-textured management group. Averagely, the plow appearing depth were deeper in ordinary management group than in sandy-textured management group, whereas the reverse in the thickness of plow pan. The particle size distribution fractal dimension ($D_m$) had higher value with finer textures, with higher fractality in coarser texture. Saturated hydraulic conductivities, $K_s$, of plow pan soils distributed from 0.5 to 1420 mm $day^{-1}$, having the highest value in sandy skeletal soils. The $K_s$ decreased with decreasing clay content and $D_m$, showing power function relationships. The coefficient of determination, $R^2$, of the fitted power functions were higher in $D_m$ as x-axis than in clay content. This means that $D_m$ could give us more effective estimation than clay content. Especially, sandy-textured paddy soils had higher $R^2$, compared to ordinary paddy soils. $K_s$ of relatively coarse-textured soils with less than 18%of clay content, therefore, was more dependent on particle size distribution than that of relatively fine-textured soils. From these results, it could be concluded that the fractal scaling gives us a unique quantity describing particle size distribution and then can be applied to estimate saturated hydraulic conductivity, especially more effective in coarse-textured soils.

The Effect of Alloy Elements on the Damping Capacity and Plasma Ion Nitriding Characteristic of Fe-Cr-Mn-X Alloys. [II Plasma Ion Nitriding Characteristic] (Fe-Cr-Mn-X계 합금의 감쇠능 및 플라즈마 이온 질화특성에 미치는 합금원소의 영향 [II플라즈마 이온 질화특성])

  • Son, D.U.;Lee, H.H.;Seong, J.H.;Park, K.S.;Kim, C.K.;Kang, C.Y.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.76-81
    • /
    • 2005
  • The effect of micro-pulse plasma nitriding temperature and time on the case thickness, hardness and nitride formation in the surface of Fe-12Cr-22Mn-X alloy with 3% Co and 1% Ti alloys elements investigated. External compound layer and internal diffusion layer was constituted in plasma nitride case of Fe-12Cr-22Mn-X alloys and formed nitride phase such as ${\gamma}'-Fe4N\;and\;{\varepsilon}-Fe2-3N$. Case depth increased with increasing the plasma nitriding temperature and time. Surface hardness of nitrided Fe-12Cr-22Mn-X alloys obtained the above value of Hv 1,600 and case depth obtained the above value of $45{\mu}m$ in Fe-12Cr-22Mn-3Co alloy and $60{\mu}m$ in Fe-12Cr-22Mn-1Ti alloy. Wear-resistance increased with increasing plasma nitriding time and showing the higher value in Fe-12Cr-22Mn-1Ti alloy than Fe-12Cr-22Mn-3Co alloy.

  • PDF

Analysis and Improvement Practise of Drainage Problem on Soil Profile at the Golf Course Fairway (골프코스 페어웨이 지반 토양의 배수불량 원인과 개선방안)

  • Lee, Jung-Ho;Jung, Gi-Rai;Lee, Jong-Min;Joo, Young-Kyoo
    • Asian Journal of Turfgrass Science
    • /
    • v.26 no.2
    • /
    • pp.129-134
    • /
    • 2012
  • Research was focused on the improvement of poor drainage problems on golf course fairway which had not been performed soil test or properly amended during the course construction. The analysis of the drainage problem basically was caused by a deterioration of soil physical properties by the top layer compaction. The soil hardness reached about 3,000 Kpa around 5~6 cm of soil profile. The slow infiltration speed to subsoil by the compaction was caused directly a poor drainage capacity. However, the properly amended sand soil showed an apparent value of 1,500 Kpa through the subsoil. The water content test showed a similar result that higher rate of 20~30% and ideal rate of 8~12% at poor drainage area and successfully amended area, respectively. However, an imported topsoil media which had higher content of silt and clay from a trans-planted sod had made a heterogeneous soil profile and that caused a poor drain capacity by a low infiltration rate. Those drainage problems triggered to buildup a reduced soil layer by poor soil gas exchange. The soil environment of deoxidation enhanced anaerobic microbial population and induced methane gas build-up to 55 ppm, and that resulted an adverse effect on turf growth by root growth retardation, consequently.

Characterization of Residual Stress in Shot Peened Al 7075 Alloy Using Surface Acoustic Wave (표면파를 이용한 쇼트피닝된 Al 7075 합금의 잔류응력 평가)

  • Kim, Chung-Seok;Kim, Yong-Kwon;Park, Ik-Keun;Kwun, Sook-In
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.291-296
    • /
    • 2006
  • The residual stress in shot-peened Al 7075 alloy was evaluated using surface acoustic wave (SAW). Shot peening was conducted to produce a variation in the residual stress with the depth below the surface under a shot velocity of 30 m/s. The SAW velocity was measured from the V(z) curve using a scanning acoustic microscopy (SAM). The Vickers hardness profile from the surface showed a significant work hardening near the surface layer with a thickness of about 0.25 mm. As the residual stress became more compressive, the SAW velocity increased, whereas as the residual stress became more tensile, the SAW velocity decreased. The variation in the SAW velocity through the shot peened surface layer was in good agreement with the distribution of the residual stress measured by X-ray diffraction technique.

Classification of Hydrologic Soil Groups of Korean Soils Using Estimated Saturated Hydraulic Conductivity and Depth of Impermeable Layer (포화 수리전도도와 불투수층 깊이에 따른 우리나라 토양의 수문학적 토양군 분류)

  • Han, Kyunghwa;Jung, Kangho;Cho, Heerae;Lee, Hyubsung;Ok, Junghun;Seo, Mijin;Zhang, Yongseon;Seo, Youngho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.5
    • /
    • pp.25-30
    • /
    • 2017
  • Hydrologic soil group is one of the important factors to determine runoff potential and curve number. This study was conducted to classify the hydrologic soil groups of Korean soils by considering saturated hydraulic conductivity and depth of impermeable layer. Saturated hydraulic conductivity of Korean soils was estimated by pedotransfer functions developed in the previous studies. Most of paddy soils were classified as D type due to shallow impermeable layer and low saturated hydraulic conductivity in B soil horizon. For upland and forest, soils classified to A and D types increased compared with former classification method because underestimated permeabilities and overestimated drainages were corrected and rock horizon in shallow depth was regarded as impermeable layer. Soils in mountainous land showed the highest distribution in A type, followed by D type. More than 60 % of soils in mountain foot-slope, fan and valley, alluvial plains, and fluvio-marine deposits were classified to D type because of land use such as paddy and upland.

The Fundamental Properties of Foamed Concrete as the Eco-friendly Ground Repair System for Cast in Site Using the CSA (CSA를 사용한 친환경 지반보수용 현장 기포콘크리트의 기초 특성 검토)

  • Woo, Yang-Yi;Park, Keun-Bae;Ma, Young;Song, Hun-Young
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.53-61
    • /
    • 2020
  • This study aimed to develop a foam concrete material for a ground repair system that has low strength and low fluidity by using an eco-friendly binder, which substitutes industrial by-products for more than 90% of cement. Basic properties were evaluated after substituting a small amount of calcium sulfo aluminate (CSA) for the binder to improve the sinking depth rate and volume change, commonly found when it had a large amount of industrial by-products. The substitution rates of CSA for the eco-friendly binder used for the foam concrete were 2.5, 5, and 10%. Fresh properties, hardened properties, pore structure, and hydrates were analyzed. Experimental results showed that using only 2.5% of CSA could improve the deep sinking depth which occurred when using an eco-friendly binder. As a result, the weight difference between the upper, middle, and lower parts of cast specimens was improved even after being hardened. The addition of CSA also contributed to the formation of small, uniformly sized closed pores and improved initial strength. However, when the proportion of CSA increased, the long-term strength decreased. However, it satisfied the target strength when 5% or less of CSA was used. The results of this study revealed that it was possible to manufacture foam concrete with low strength and high fluidity for repairing ground satisfying target qualities by adding 2.5% of CSA to the eco-friendly binder containing a large amount of industrial by-products.

GEOMETRIC NINLINEAR ANALYSIS OF UNERGROUND LAMINATED COMPISITE PIPES (기하학적 비선형을 고려한 지하매설 복합재료 파이프의 해석)

  • 김덕현;이인원;변문주
    • Computational Structural Engineering
    • /
    • v.2 no.1
    • /
    • pp.65-70
    • /
    • 1989
  • An analytical study was conducted using the Galerkin technique to determine behaviour of thin fibrereinforced and laminated composite pipes under soil pressure. Geometric nonlinearity and material linearity have been assumed. It is assumed that vertical and lateral soil pressure are proportional to the depth and lateral displacement of the pipe respectively. It is also assumed that radial shear stress is negligible because the ratio of thickness to the radius of pipe is very small. The above results are verified by the finite element analysis.

  • PDF

Mechanical Properties of The CO2 Free Vacuum Carburized in SCM415H (CO2 무 배출 침탄 열처리된 SCM415H 소재의 기계적 성질)

  • Byun, Jae-Hyuk;Ro, Seung-Hoon;Lee, Jong-Hyung;Lee, Chang-Hun;Yang, Seong-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.971-978
    • /
    • 2012
  • Vacuum carburizing is supposed to be the superior process to the gas carburizing. However, the vacuum carburizing has the stage in which hydrocarbon gas is supplied into the furnace to be pyrolysis, and consequently the stable heat treatment is hard to achieve due to the soot from the hydrocarbon pyrolysis. Recently, many studies have been made which utilize acetylene gas to overcome this defects. In this paper, the carburizing and the diffusion periods have been selected based on the Harris experimental formula, and the mechanical properties of the vacuum carburized specimen have been compared with those of the gas carburized SCM415H specimen to identify the feasibility of the $CO_2$ free vacuum carburizing process. The result showed that the vacuum carburized materials used have no oxidization of the grain boundaries, and show the 29.8% higher effective hardness depth and the acceptable tensile strength.

Limitation of Nitrogen ion Implantation and Ionplating Techniques Applied for Improvement of Wear Resistance of Metallic Implant Materials (금속 임플란트 소재의 내마모성 향상을 위하여 적용되는 질소 이온주입 및 이온도금법의 한계)

  • 김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Nitrogen ion implantation and ion plating techniques were applied for improvement of the wear resistance of metallic implant materials. In this work, the wear dissolution behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The amounts of Cr and Ni ions worn-out from the specimens were Investigated using an electrothermal atomic absorption spectrometry. Furthermore, the Ti(Grade 2) disks were coated with TiN, ZrN and TiCN by use of low temperature arc vapor deposition and the wear resistance of the coating layers was compared with that of titanium. The chemical compositions of the nitrogen ion implanted and nitride coated layers were examined with a scanting auger electron spectroscopy. It wat observed that the metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. From the results obtained, it was shown that the nitrogen ion implanted zone obtained with 100 KeV ion energy was easily removed within 200,000 revolutions from a wear dissolution testing under a similar load condition when applied to artificial hip joint. The remarkable improvement in wear resistance weir confirmed by the nitrides coated Ti materials and the wear properties differ greatly according to the chemical composition of the coating layers. for specimens with the same coating thickness of about 3$\mu\textrm{m}$, TiCN coated Ti showed the highest wear resistance. However, after removing the coating layers, the wear rates of all nitrides coated Ti reverted to their normal rates of below 10,000 revolutions from Ti-disk-on-disk wear testing under the same load condition. From the results obtained, it is suggested that the insufficient depth of the 100 Kel N$\^$+/ ion implanted zone and of the nitrides coated layers of 3$\mu\textrm{m}$ are subject to restriction when used as frictional parts of load bearing implants.