• Title/Summary/Keyword: 경사창호

Search Result 22, Processing Time 0.024 seconds

The Calculation on the Optimum Angle of Tilt Type Window by Length of Transmitted Solar Radiation (투과일사의 유입길이에 따른 Tilt 창호의 적정 기울기 산정)

  • Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.635-640
    • /
    • 2010
  • This study is suggested tilt window type to be restrained solar radiation through vertical window type in buildings. The shading and aesthetical effect of buildings would be solved by installation of tilt window type. For investigate optimum an angle of tilt window and building azimuth in reference region, the distance of transmitted solar radiation is calculated. The results of calculation showed optimum an angle of tilt window is obtained $7^{\circ}$ that the distance of transmitted solar radiation is 20% of 1.5m of balcony width. In case of an tilt window angle of $7^{\circ}$, the optimum building azimuth is showed $SW15^{\circ}{\sim}SE15$.

The Heat Transfer Characteristics on Impinging Surface by Oblique Jet (경사 제트에 의한 충돌면에서의 열전달 특성)

  • 이창호;조형희;정학재
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.28-28
    • /
    • 1998
  • 단일 충돌제트의 경우 충돌면에서의 열전달 효과는 제트 출구와 충돌면 사이의 간격, 노즐 형상에 따른 제트출구의 초기조건, Re$_{D}$수 변화와 충돌면의 형상이나 표면거칠기 등에 따라 변화하게 된다. 그러나 수직 충돌제트의 경우 정체영역에서의 국소적인 열전달 향상은 용이하나 반경 방향으로 열전달이 점차 감소하게 된다. 따라서 충돌면의 전반적인 열전달 향상을 위해서는 열전달이 정체점보다 상대적으로 낮은 영역에서 열전달 향상이 필요하다. 또한, 실제 적용시 충돌면의 형상이나 협소한 공간에서 노즐위치의 제약으로 인하여 충돌제트가 수직으로 분사되는 경우보다 경사진 제트가 더욱 많이 응용된다. 더욱이, 수직충돌제트가 사용되는 많은 상황에서도 주위의 다른 공기 흐름의 영향으로 인하여 실제 제트가 경사각을 갖고 분사되어진다 이러한 경사충돌제트의 중요성에도 불구하고 경사충돌제트에 대한 연구는 수직충돌제트에 대한 연구보다 상대적으로 적게 이루어져 왔다.

  • PDF

Flow and Heat Transfer Characteristics on Oblique Impingement Surface by Single Axisymmetric Jet (단일 축대칭제트에 의한 경사충돌면에서 유동 및 열전달 특성)

  • 이창호;황상동;조형희;정학재
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.1
    • /
    • pp.34-40
    • /
    • 1999
  • An experimental study has been conducted to determine the effects of inclined impinging jet on the local heat transfer coefficients. A single jet with nozzle diameter of 24.6 mm was tested for Reynolds numbers from 10,000 to 70,000 and nozzle-to-plate spacings of 2~6 jet diameters. The angle of inclination of the impingement surface relative to the horizontal surface was varied from $0^{\cire}$ (normal impingement) to $60^{\cire}$. The results indicate that the point of maximum heat transfer is moved up from the geometrical stagnation point of inclined surface by Coanda effect. The local heat transfer coefficients on the minor jet region decrease more rapidly than on the major jet region, thus creating an imbalance in the cooling capabilities on the two sides.

  • PDF

A Study on the Architectural Basic Planning of University Hospital in Sloped Suburb - Focused on the Design Competition of K University Hospital - (교외의 경사지형을 이용한 대학병원의 건축기본계획에 대한 연구 - K대학병원 설계경기를 중심으로 -)

  • Moon, Chang-Ho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.1 no.2
    • /
    • pp.91-101
    • /
    • 1996
  • This study is intended to summarize the contents and process of an architectural basic planning for the design competition of K University Hospital. Especially a design of low-rise and compact type hospital in sloped suburb is suggested. The major contents consists of proposed premise of planning, goal of planning, site analysis, site plan, and architectural basic plan To realize the concept of low-rise and compact type hospital which reconciles to the natural environment of the site, 4 nursing units per typical floor and hospital street system are introduced. And to design a "hospital unlike hospital", streamline form of hospital building is proposed.

  • PDF

Unsteady Flow in a Roof Drain (지붕 배수의 부정류)

  • 황창호;윤태훈
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1989.07a
    • /
    • pp.163-172
    • /
    • 1989
  • 강우로 인한 급경사면의 흐름 해석은 지배방정식인 연속방정식과 운동량 방정식에 의해 수치적으로 해석된다. 이에대한 해석 방법에는 수문학적인 방법과 수리학적인 방법이 있는데, 본 연구에서는 세인트 베난트 방정식을 초기 및 경계조건에 맞게 푸는 수리학적인 방법을 이용하였고, 일반적인 완경사면에서 그 영향이 작아 무시되었던 경사의 영향을 고려한다. 수치해석 과정은 지배방정식에 무차원 매개변수를 도입하여 6점 음해법을 이용하여 해석하였다. 수치실험은 마닝(Manning)의 조도계수 n을 변화시키면서, 각각 검사에서 강우에 의한 평형상태에 도달한 이후의 수심과 유량, kinematic flow 수, 후르드 수, 평형상태 도달시간등 변수 상호간의 관계를 고찰하였다.

  • PDF

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load (냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구)

  • An, Hyung-Jun;Kim, Young-Tag;Choi, Chang-Ho;Lee, Hyn-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.77-87
    • /
    • 2004
  • BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.

Assessment of Extreme Wind Risk for Window Systems in Apartment Buildings Based on Probabilistic Model (확률 모형 기반의 아파트 창호 시스템 강풍 위험도 평가)

  • Ham, Hee Jung;Yun, Woo-Seok;Choi, Seung Hun;Lee, Sungsu;Kim, Ho-Jeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.625-633
    • /
    • 2015
  • In this study, a coupled probabilistic framework is developed to assess wind risk on apartment buildings by using the convolution of wind hazard and fragility functions. In this framework, typhoon induced extreme wind is estimated by applying the developed Monte Carlo simulation model to the climatological data of typhoons affecting Korean peninsular from 1951 to 2013. The Monte Carlo simulation technique is also used to assess wind fragility function for 4 different damage states by comparing the probability distributions of the window system's resistance performance and wind load. Wind hazard and fragility functions are modeled by the Weibull and lognormal probability distributions based on simulated wind speeds and failure probabilities. The modeled functions are convoluted to obtain the wind risk for the different damage levels. The developed probabilistic framework clearly shows that wind risk are influenced by various important characteristics of terrain and apartment building such as location of building, exposure category, topographic condition, roof angle, height of building, etc. The risk model presented in this paper can be used as tools to predict economic loss estimation and to establish wind risk mitigation plan for the existing building inventory.

A Numerical Analysis on the Rotordynamic Characteristics of A Hybrid Journal Bearing with Pair-Type Angled Injection Orifices (짝(Pair)형태의 경사 공급구를 갖는 하이브리드 저널 베어링의 로터 동특성에 관한 수치해석)

  • 김창호;이용복
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.111-121
    • /
    • 1997
  • The stability of a rotor-bearing system supported by swirl-controlled hybrid journal bearing with pair-type angled injection orifices is investigated for improvement of the whirl frequency ratio by allowing effective control of the tangential flow inside the bearing clearance, i.e., by achieving more freedom in controlling strength and direction of the supply tangential flow inside the bearing clearance. It is suggested that the system instability can be improved through the change of bearing dynamic characteristic parameters with the swirl control. The orifice diameter d$_0$ and recess injection angle $\alpha$ along with combinations of swirl/anti-swirl supply pressures and directions (3.0-3.0MPa, 4.0-2.0MPa, 2.0-4.0MPa) are selected for design parameters for swirl-controlled effective factors dependent on journal speeds (3000, 9000, 15000, 21000 rpm). It has been found that the orifice diameter do shows strong effects on effective maneuverability of direct-stiffness and direct damping values, while recess injection angle $\alpha$ results in substantial magnitude and direction of cross-stiffness. Specifically, recess injection parameters which are functions of angle of orifice feeding flow and recess dimensions showed very feasible effect on the stability of swirl-controlled rotor-bearing system.

  • PDF