• Title/Summary/Keyword: 경계층 온도장

Search Result 22, Processing Time 0.032 seconds

Analysis on the Modification of Near-wall Turbulent Characteristics of Temperature Field in a Channel imposed with Linearly Increasing Wall Disturbance (선형적으로 증가하는 벽면교란이 벽 근처 난류 온도장의 특성 변화에 미치는 영향 해석)

  • Park, Soo Hyung;Byun, Yung-Hwan;Na, Yang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.101-112
    • /
    • 2013
  • Large eddy simulation was performed to investigate the effect of linearly increasing wall disturbance on the modification of turbulent characteristics of temperature field in the vicinity of the wall. It was noted that temperature variance increased monotonically whereas temperature dissipation decreased significantly, resulting in a noticeable reduction in both time and length-scales. A sudden drop in turbulent Prandtl number down to around 0.25 in the near-wall region indicated that the similarity between velocity and temperature fields decreases near the wall as a result of linear wall disturbance.

The Daytime PBL Heating Process and Heating Rate by Meso-Scale Circulation (중규모 순환에 의한 대기경계층 가열과정과 주간 가열율 산정에 관한 연구)

  • 이화운;정우식;김동혁
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.441-442
    • /
    • 2003
  • 복잡한 지형에서 국지적인 순환에 의한 에너지 교환은 기상변화에 중요한 역할을 담당한다. 종관장이 영향이 약하고 양호한 기상조건 하에서 대기 경계층내에서의 온도와 바람장은 국지적인 순환에 영향을 받는다(Kawamura,1979; Kuwagata et al.,1990; Winston et al.,1992). 즉 이러한 기상 조건 하에서는 중규모 순환에 의해 에너지의 수송효과가 크고 각기 수송된 에너지에 의해서 지역별로 대기 경계층내의 가열율에도 차이가 나타난다. (중략)

  • PDF

Sensitivity Experiments of Vertical Resolution and Planetary Boundary Layer Parameterization Schemes on the Seoul Metropolitan Area using WRF Model (수도권 지역의 고해상도 WRF 모델 기반 연직 해상도 및 경계층 모수화 방안 민감도 실험)

  • Lim, A-Young;Roh, Joon-Woo;Jee, Joon-Bum;Choi, Young-Jean
    • Journal of the Korean earth science society
    • /
    • v.36 no.6
    • /
    • pp.553-566
    • /
    • 2015
  • The effects of vertical resolutions and planetary boundary layer (PBL) physics schemes in a numerical simulation with a very high resolution over the metropolitan area were investigated. The numerical experiments using the Weather Research and Forecast model were conducted from 0000 UTC 25 October to 0000 UTC 26 October 2013. We verified the numerical results against with six hourly observation data from the radiosonde at Seolleung, which was located in southern part of Seoul, and forty three auto weather systems in Seoul. In the experiments of vertical resolutions in low level atmosphere with 44, 50, and 60 layers, which are set to be subdivided particularly under 2 km height. The experiment in 60 layers, which has the highest vertical resolution in this study, showed relatively a clear diurnal variation of PBL heights. Especially, the difference of PBL heights and 10-meter wind fields were mainly seen in the area of high altitude lands for the experiments of vertical resolution. In the sensitivity experiment of PBL schemes such as asymmetric convective model-version 2 (ACM2), Yonsei University (YSU), and Mellow-Yamada-Janjic (MYJ) to the temperature, all three PBL schemes revealed lower temperature than observed profile from the radiosonde in the entire period. The experiments with YSU PBL and ACM2 PBL schemes show relatively less biased in comparison with the experiment of the MYJ PBL scheme.

Numerical Analysis of Natural Convection in Room Fire (화재실내 자연대류의 수치해석)

  • Jung Gil-Soon;Lee Seung-Man;Lee Byung-Kon
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.18-25
    • /
    • 2005
  • In this study, numerical analysis of two-dimensional unsteady natural convection of air in a square enclosure heated from below, was performed as a basic research of fire science. SIMPLE algorithm was used to the pressure term of momentum equations in the numerical analysis. The numerical analysis were studied for the two model cases and two heat conditions, respectively, which are different with insulation of enclosures and position of heat applied. Also, the ceiling temperatures of enclosure were measured to compare the accuracy of numerical analysis, and it is found that the temperature predicted by numerical analysis were agreed well with the measurements. Streamline and isotherm of the each model case were acquired for each time step.

Numerical Simulation of Changes on Mixed Layer Depth with Climate Variability : SCHISM model (기후변동성을 고려한 연안해역의 혼합층 두께 변화양상 검토: SCHISM 적용)

  • Yoo, Hyung Ju;Lee, Joon-Soo;Kim, Dong Hyun;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.273-273
    • /
    • 2022
  • 혼합층(Mixed layer)은 온도가 일정한 수심층으로, 해수표면에 작용하는 바람의 영향으로 인하여 해수가 위아래로 섞여 형성된다. 이러한 혼합층은 영양염의 순환과 산소의 공급 등과 함께 일차생산량을 결정하는 중요한 요인이 될 수 있으며 혼합층 두께의 변동은 양식 산업에 영향을 미칠 수 있다. 최근에는 기후변화로 인한 해수면 상승 및 해수온 상승 등이 지속되고 있으며, 이러한 현상은 해양생태계의 변화를 초래하여 수산업의 피해를 유발할 수 있다(강원연구원, 2017). 이에 국립수산과학원, 기상청, 국립해양조사원 등 유관기관에서는 정선해양 수온 관측 및 해수순환모델을 이용하여 혼합층의 분석을 수행하고 있으나 격자 구축 및 초기·경계장 설정의 한계가 존재하여 정밀하고 정확한 혼합층 분석에는 어려움이 있다. 이에 본 연구에서는 비정형격자를 사용하여 격자 구축에 제약이 없는 SCHISM (Semi-implicit Cross-scale Hydroscience Integrated System Model)을 이용하여 우리나라 연안해역의 계절변화 및 기후변동성에 따른 혼합층 두께의 변화를 검토하고자 한다. 연구대상지는 서해·동해·남해를 포함한 우리나라 전체 연안 해역(위도: 32°N ~ 39°N, 경도: 124°E ~ 132°E)으로 선정하였으며, 격자크기 100 ~ 3,000 m인 삼각격자로 격자를 구축하였다. 혼합층을 분석하기 위하여 수직격자 층은 50층으로 SZ(Sigma Z coordinate system)좌표계를 사용하였다. 초기·경계장은 FES(Finite Element Solution)2014, HYCOM(Hybrid Coordinate Ocean Model) 및 대기모델 결과를 이용하여 설정하였다. 수치모형 검증을 위하여 수온관측소에서 수심별 측정한 수온 값과 SCHISM 결과 값을 비교하였고, 상대오차가 약 10% 이내로 나타나 모형의 정확도를 확인하였다. 최종적으로 해수면 상승 및 해수온 상승 시나리오를 고려하여 계절별 연안해역의 혼합층 두께의 변화 양상에 대하여 검토하였다. 향후에는 보다 정밀한 대기모델과의 혼합모형 구축 및 다양한 수심 별 관측자료를 활용한다면 실무에서 적용 가능한 혼합층 분석 및 수산업 피해 발생 지역에 대한 피해저감 대책 수립이 가능할 것으로 판단된다.

  • PDF

The Throughflow Effects on Natural Convection in Horizontal Porous Layer (수평 다공층에서 수직 관통류가 자연대류 열전달에 미치는 영향에 관한 연구)

  • 서석진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.209-215
    • /
    • 1998
  • This paper investigated the vertical throughflow effects on natural convection due to heating from below in horizontal porous layer. The motion of the fluid in the porous layer is governed by Brinkman-Darcy equation. And compared Critical Rayleigh number in case of throughflow with no throughflow. Investigated Nusslet number, isothermalline and flow with the variation of the strength of throughflow in a constant Rayleigh number. In the numerical analysis, flow is assumed to be two-dimensional and unsteady. The numerical scheme used is a finite-difference method. In the experimental study, Temperature distribution was measured by use of Liquid Crystal film. As a results, indicated that throughflow influences largely on the temperature field and as the strength of throughflow increased, unstability of natural convection decreased. Also it could predict the strength of natural convection with the measured Nusselt number.

  • PDF

A Study on the Thermal Boundary Layer Flow of a Micropolar Fluid in the Vicinity of a Wedge (미세극성 유체 유동장에 놓여진 쐐기형 물체주위의 열경계층에 관한 연구)

  • 김윤제
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.122-127
    • /
    • 1999
  • The characteristics of thermal boundary layer flow of a micropolar fluid in the vicinity of a wedge has been studied with constant surface temperature. The similarity variables found by Falkner and Skan are employed to reduce the streamwise-dependence in the coupled nonlinear boundary layer equations. Numerical solutions are presented for the heat transfer characteristics with Pr=1 using the fourth-order Runge-Kutta method and their dependence on the material parameters is discussed. The distributions of dimensionless temperature and Nusselt number across the boundary layer are compared with the corresponding flow problems for a Newtonian fluid over wedges. Numerical results show that for a constant wedge angle with a given Prandtl number, Pr=1, the effect of increasing values of K results in an increasing thermal boundary thickness for a micropolar fluid, as compared with a Newtonian fluid. For the case of the constant material parameter K, however, the heat transfer rate for a micropolar fluid is lower than that of a Newtonian fluid.

  • PDF

Study on Thermal Insulation Design and Heat Flow Analysis of Spacecraft Shipping Container (위성 운송용 컨테이너의 단열 설계와 열 유동 해석에 관한 연구)

  • Park, Sang-Rae;Lee, Choon-Woo;Kim, Jin-Taek
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.1
    • /
    • pp.8-15
    • /
    • 2020
  • In this paper, we propose a container wall and its boundary layer insulation design method that can maintain the temperature inside the spacecraft shipping container constantly under the condition that the heat or the external temperature changes severely to safely transport the satellite to the launch site. We will examine if the temperature inside the satellite shipping container is kept constant through the heat flow analysis and the satellite heat transfer analysis for the external environment of the satellite shipping container. Through the flow analysis inside the container, the flow distribution around the satellite in the container is analyzed, and the auxiliary fan, air conditioning system and special grill guide structure design for improving and optimizing heat flow performance are proposed.

Aerodynamic Heating Analysis of Supersonic Missile Body and Fin (초음속 유도탄 동체와 날개의 공력가열 해석)

  • Kang, Kyoung-Tai
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.20-28
    • /
    • 2008
  • Missile operating at supersonic conditions experiences considerable high temperature environments that is caused by aerodynamic heating as a result of the temperature gradient through boundary layer that surrounds it. This is one of important problems to the designer due to temperature limitation of structural materials. Because prediction of aerodynamic heating on missile needs unsteady calculation according to a flight trajectory, approximate method approach is efficient at design stage. In this paper, improved aerodynamic heating analysis scheme is introduced, which calculates heat flow and temperature by simple pressure field prediction on a missile body and fin. The prediction results are compared with measured data and MINIVER codes results.

Film Cooling from Two Rows of Holes with Opposite Orientation Angles(I) -Configuration Effect- (반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성(I) -배열의 영향-)

  • Ahn, Joon;Jung, In-Sung;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1122-1130
    • /
    • 2001
  • Film cooling performance from two rows of holes with opposite orientation angles is evaluated in terms of heat flux ratio. The film cooling hole has a fixed inclination angle of 35°and orientation angle of 45°for the downstream row and -45°for the upstream row. Four film cooling hole arrangements including inline and staggered configurations are investigated. The blowing ratio studied was 1.0. Boundary layer temperature distributions are measured to investigate injectant behaviors and mixing characteristics. Detailed distributions of the adiabatic film cooling effectiveness and the heat transfer coefficient are measured using TLC(Thermochromic Liquid Crystal). For the inline configuration, there forms a downwash flow at the downstream hole exit to make the injectant well attach to the wall, which gives high adiabatic film cooling effectiveness and heat transfer coefficient. The evaluation of heat flux ratio shows that the inline configuration gives better film cooling performance with the help of the downwash flow at the downstream hole exits.