• Title/Summary/Keyword: 결합강도

Search Result 1,844, Processing Time 0.03 seconds

Bond Strength between Co-Cr Alloy Metal and Ceramic (Co-Cr 합금의 금속-도재 결합 강도)

  • Kim, Min-Jeong;Park, Gwang-Sig
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.3
    • /
    • pp.602-608
    • /
    • 2021
  • For the comparison of bond strength between the Co-Cr alloy and ceramic, which are clinically used, test samples made with a traditional casting method as a control group), and Milling and SLM(3d printing group) samples were made as an experimental group. The metal-ceramic bond strength was measured with a universal testing machine. For the measurement, a three-point bending test was conducted. After the bond strength was measured, metal-ceramic interface was observed. According to the test result, casting group had 53.59 MPa, milling group had 45.90 MPa, and 3d printing group had 58.34 MPa. There was no statistical significance. With regard to failure pattern, most of the samples in two groups, showed mixed failure. This study showed a clinically applicable value when measuring the bond strength of alloy-ceramic material with an alloy produced by 3D printing.

Shear bond strength and adhesive failure pattern in bracket bonding with plasma arc light (Plasma arc light를 이용한 bracket 부착시의 전단결합강도와 파절양상의 유형)

  • Yoo, Hyung-Seok;Oh, Young-Geun;Lee, Seung-Yeon;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.261-270
    • /
    • 2001
  • The purpose of this study was to evaluate the clinical usefulness of plasma arc light which can reduce the curing time dramatically compared by shear bond strengths and failure patterns of the brackets bonded with visible light in direct bracket bonding. Some kinds of brackets were bonded with the Transbond$^{\circledR}$ to the human premolars which were embedded in the resin blocks according to the various conditions. After bonding, the shear bond strength was tested by Instron universal testing machine and in addition , the amount of residual adhesive remaining on the tooth after debonding was measured by the stereoscope and assessed with adhesive remnant index(ARI). The results were as follows : 1. When plasma arc light was used for bonding the brackets, the shear bond strength was clinically sufficient in both metal and ceramic brackets, but resin brackets showed significantly lower bond strength but which was clinically useful. 2. When metal brackets were bonded using visible light, there was no significant difference in shear bond strength due to the light-curing time and the bond strength was clinically sufficient. 3. When the adhesive failure patterns of brackets bonded with plasma arc light were observed by using the adhesive remnant index, the bond failure of the metal and resin bracket occurred more frequently at bracket-adhesive interface but the failure of the ceramic bracket occurred more frequently at enamel-adhesive interface. 4. There was no statistically significant difference of the shear bond strength and adhesive failure pattern between metal bracket bonded for 2 seconds by curing with plasma arc light and 10 seconds by curing with visible light. 6. When metal brackets were bonded using plasma arc light, the shear bond strength decreased as the distance from the light source increased. The above results suggest that plasma arc light can be clinically useful for bonding the brackets without fear of the decrease of the shear bond strength.

  • PDF

A study on the shear bond strength between Co-Cr denture base and relining materials (금속의치상과 의치이장재료 간의 결합력에 관한 연구)

  • Lee, Na-Young;Kim, Doo-Yong;Lee, Young-Soo;Park, Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.8-15
    • /
    • 2011
  • Purpose: This study evaluated the bonding strength of direct relining resin to Co-Cr denture base material according to surface treatment and immersion time. Materials and methods: In this study, Co-Cr alloy was used in hexagon shape. Each specimen was cut in flat surface, and sandblasted with $110\;{\mu}m$ $Al_2O_3$ for 1 minute. 54 specimens were divided into 3 groups; group A-control group, group B-applied with surface primer A, group C-applied with surface primer B. Self curing direct resin was used for this study. Each group was subdivided into another 3 groups according to the immersion time. After the wetting storage, shear bond strength of the specimens were measured with universal testing machine. The data were analyzed using two-way analysis of variance and Tukey post hoc method. Results: In experiment of sandblasting specimens, surface roughness of the alloy was the highest after 1 minute sandblasting. In experiment of testing shear bond strength, bonding strength was lowered on group B, C, A. There were significant differences between 3 groups. According to period, Bonding strength was the highest on 0 week storage group, and the weakest on 2 week storage group. But there were no significant differences between 3 periods. According to group and period, bonding strength of all group were lowered according to immersion time but there were no significant differences on group B and group C, but there was significant difference according to immersion time on group A. Conclusion: It is useful to sandblast and adopt metal primers when relining Co-Cr metal base dentures in chair-side.

Measurement of Contact Angle and Bond Strength Using 3 Different Self-Etching Primer (3종의 자가부식 프라이머의 상아질계면 접촉각 및 미세인장결합강도에 관한 연구)

  • Chang, Seok-Woo;Kwon, Ho-Beom;Yoo, Hyun-Mi;Park, Dong-Sung;Oh, Tae-Seok;Bae, Kwang-Shik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • The purpose of this study was to evaluate the contact angle made by 3 kinds of self etching primers (Clearfil SE Bond, AdheSE, and Tyrian) on dentin and to measure the microtensile bond strength of resin composite to dentin using these self-etching primers. Contact angle between each of 3 self etching primers and polished dentin surface was measured (n=30) by contact angle analyzer and the result was analyzed by One-way ANOVA. For the measurement of microtensile bond strength, polished dentin surface was treated with each of 3 self etching primers and dentin adhesives. Z-250 composite resin was built-up with a height of 5 mm on the adhesive-treated surface and light cured for 40s with a halogen light curing unit. Thereafter, each tooth was sectioned into slabs perpendicular to the bonded interface and trimmed (n=45). The microtensile bond strength was measured with universal testing machine and the result was analyzed with Kruskal-Wallis test. AdheSE group showed the highest contact angle followed by Clearfil SE group and Tyrian group (p<0.05). AdheSE group and Clearfil SE group showed significantly higher microtensile bond strength than Tyrian group (P<0.05).

A STUDY ON THE SHEAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER CEMENT (광중합형 글래스아이오노머 시멘트의 전단결합강도에 대한 연구)

  • Kim, Hyun-Yang;Tae, Ki-Chul;Kook, Yoon-Ah;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.689-698
    • /
    • 1998
  • The purpose of this study was to evaluate the shear bond strength of light cured glass ionomer cement to enamel surface which treated with $37\%$ phosphoric acid, $10\%$ polyacrylic acid, $1.23\%$ acidulated phosphate fluoride gel and no etching agent. To compare the shear bond strength of glass ionomer cement, light-cured composite resin and chemically-cured composite resin were empoloyed as controls. Eight experiments groups were composed. 10 specimens of each group were bonded by metal bracket by tested in universal testing machine for shear bond strength, in stereoscope for adhesive remnants index. The data were evaluated statistically by SPSS/PC+. The results were as follows. 1. Among the groups of $37\%$ phosphoric acid treated and dry and bonded with light cured glass ionomer, light cured composite resin, and chemically cured composite resin, the shear bond strength of glass ionomer group showed no significant difference to the others, but the shear bond strength of chemically cured resin showed statistically lower than that of light cured resin (p<0.05). 2. The shear bond strengths of glass ionomer cement to enamel treated group with $1.23\%$ acidulated phosphate fluoride gel and $10\%$ polyacrylic acid and $37\%$ phosphoric acid showed statistically higher than that of no etched enamel group(p<0.U). 3. In the groups of glass ionomer cement, the presence of moisture was not significantly effect to the shear bond strength (p<0.05). 4. After debonding, no etched enamel group showed less residual materials on the enamel surface than the group of enamel etched with $37\%$ Phosphoric acid.

  • PDF

The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods (브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교)

  • Shin, Jai-Ho;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.333-342
    • /
    • 2004
  • The purpose of this study was to evaluate the clinical effectiveness of a plasma arc light and light emitting diode (LED), compared with shear bond strength and the failure pattern of brackets bonded with visible light in direct bonding. Brackets were bonded with Transbond XT to 60 human premolars embedded in the resin blocks according to different light-curing methods. Then, the shear bond strength of each group was measured using a universal testing machine (Instron) and the adhesive failure pattern after debonding was visually examined by light microscope. The results were as follows: 1. The shear bond strength showed no significant difference between the visible light and light emitting diode, but the plasma arc light exhibited a significantly lower shear bond strength compared with the visible light and light emitting diode. 2. In the visible light and light emitting diode, adhesive failure patterns were similar. Bond failure occurred more frequently at the enamel-adhesive interface. 3. The bonding failure of brackets bonded with plasma arc light occurred more frequently at the bracket-adhesive interface. The results of this study suggest that plasma arc light, light emitting diode and visible light are all clinically useful in the direct bonding of orthodontic brackets.

Comparative study of surface modification on bond strength of polyetherketoneketone adhesively bonded to resins for temporary restoration (Polyetherketoneketone의 표면처리 방법에 따른 임시 보철물 제작용 레진과의 결합 강도 비교 연구)

  • Hong, Mun Gi;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • Purpose: The purpose was to compare shear bond strength (SBS) of three types of resin for temporary restoration to polyetherketoneketone (PEKK) depending on surface modification. Materials and Methods: Sixty disks made from PEKK were air-abraded with 110 ㎛ alumina particles (Cobra, Renfert GmbH, Hilzinge, Germany) and thirty specimens were divided into two groups each: PEKK without Visio.link (Bredent, Senden, Germany)(U) and with Visio.link (P). Resins for temporary restoration (polymethylmethacrylate; PMMA, polyethylmethacrylate; PEMA, bis-acryl composite resin) in the shape of a square with one side 3.2 mm were bonded to PEKK twenty respectively and classified into six groups (UM, UE, UC, PM, PE and PC). All specimens were stored in distilled water at 37℃ for 24 hours. SBS of each group was measured at a crosshead speed of 2 mm/min in universal testing machine. SBS was compared using one-way ANOVA and a Tukey HSD test (P = 0.05). Results: Group UM and group UE showed a significant difference in SBS with group UC (P < 0.05). Group PC showed a significant increase in SBS than group UC (P < 0.05). Conclusion: It is recommended to apply Visio.link to PEKK for adhering bis-acrylic composite resin, but not for PMMA and PEMA in clinical practice.

The Effect of Bonding Resin on Bond Strength of Dual-Cure Resin Cements (접착레진의 부가도포가 레진 시멘트의 결합강도에 미치는 영향에 대한 연구)

  • Kim, Duck-Su;Park, Sang-Hyuk;Choi, Gi-Woon;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.426-436
    • /
    • 2007
  • The objective of this study is to evaluate the effect of an additional application of bonding resin on the bond strength of resin luting cements in both the light-cure (LC) and self-cure (SC) modes by means of the ${\mu}TBS$ tests. Three combinations of One-Step Plus with Choice, Single Bond with Rely X ARC, and One-Up Bond F with Bistite II were used. D/E resin and Pre-Bond resin were used for the additional application. Twelve experimental groups were made. Three mandibular $3^{rd}$ molars were used in each group. Indirect composite blocks were cemented on the tooth surface. $1\;{\times}\;1\;mm^2$ dentin-composite beam for ${\mu}TBS$ testing were made and tested. When total-etching dentin adhesives were used, an additional application of the bonding resin increased the bond strength (P < 0.05). However, this additional application didn't influence the bond strength of self-etching dentin adhesives (P > 0.05). In conclusion, the results suggest that an additional application of the bonding resin increases bond strength and enhances quality of bonding when using total-etching dentin adhesives.

Shear bond strength of ceramic brackets bonded with antimicrobial monomer-containing self-etching primer (항미생물제제를 포함한 self-etching primer로 접착한 세라믹 브라켓의 전단 결합 강도)

  • Kwon, Tae-Hun;Kang, Jang-Mi;Chang, Na-Young;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.16-24
    • /
    • 2011
  • Objective: The purpose of this study was to determine (1) the shear bond strength (SBS) of an antimicrobial monomer-containing self-etching primer according to ceramic bracket types and (2) the bracket-adhesive failure mode using an adhesive remnant index (ARI). Methods: A total of 90 extracted human teeth were randomly divided into 6 groups. Each group consisted of one of two ceramic brackets (monocrystalline, polycrystalline) and one of three primers (Transbond XT primer, Transbond Plus SEP, Clearfil Protect Bond) with each group containing 15 specimens. The SBS was measured, and adhesive residues left on the tooth surface were assessed. Results: The SBS of polycrystalline ceramic bracket groups was Significantly higher than that of the monocrystalline ceramic bracket groups (p < 0.001). The SBS of Transbond XT primer groups was significantly higher than those of Transbond Plus SEP groups and Clearfil Protect Bond groups (p < 0.001). All the groups showed bonding failures between the bracket base and adhesive. Conclusions: The combination of a self-etching primer with a monocrystalline bracket is recommended for clinical use, considering its acceptable SBS and mode of failure.

EFFECTS OF PHOSPHORIC ACID CONCENTRATION ON DEPTH OF ETCH AND SHEAR BOND STRENGTH OF ORTHODONTIC BRACKETS TO BOVINE ENAMEL (인산농도가 소의 법랑질에서 부식깊이와 브라켓 전단결합강도에 미치는 영향)

  • Kim, Soo-Cheol;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.341-353
    • /
    • 1995
  • Previous study had shown the diversities in the propriety for optimal bond strength on the concentration of the etchant. The aim of present study in vitro was to evaluate and compare the shear bond strength of orthodontic brackets to enamel and to measure the depth of etch on the phosphoric acid concentrations. A hundred and seventy six extracted bovine lower centrals were ground to yield flat surfaces and etched by the concentration $0%,\;5%,\;10%,\;20%,\;30%,\;40%,\;50%,\;60%,\;70%,\;80%\;and\;85\%$ of phosphoric acid respectively during 60 seconds. The shear bond strength of orthodontic brackets, the depth of etch and surface roughness of the enamel were measured, and scanning electron microscopic observations on the etched enamel surfaces were carried out. The data obtained from the very experiments were processed and statistically analyzed and evaluated. The gradual increase in the depth of etch to enamel as the accretion of the concentration of the phosphoric acid upto $40-50\%$ and decline henceforth were manifested. The surface roughness showed no correlation with the depth of etch, yet moderate correlation with the shear bond strength of brackets. Scanning electron microscopic investigation revealed that morphological patterns of the etched enamel surfaces for $5\%\;to\;40\%$ of concentrations were even and homogenous, and those for $50\%$ as well as $60\%$ exhibited the overetched and unhomogenous. The shear bond strengths kom $10\%\;to\;60\%$ of concentration showed no statistically significant differences. It was suggested that the shear bond strengths at $5\%\;and\;70\%$ were sufficient to tolerate the force levels of the ordinary orthodontic treatment notwithstanding to be significantly lower than those from $10\%\;to\;60\%$ phosphoric acid solution.

  • PDF