• Title/Summary/Keyword: 견관절 골절

Search Result 107, Processing Time 0.023 seconds

Percutaneous Mini-open Reduction for Mason II or III Radial Head and Neck Fracture (요골 두 및 경부 골절의 경피적 도수 정복술)

  • Lee, Jeong-Gil;Koh, Il-Hyun;Kim, Hyung-Sik;Choi, Yun-Rak;Kim, Sung-Jae;Kang, Ho-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.230-236
    • /
    • 2010
  • Purpose: We wanted to evaluate the result of percutaneous, mini-open reduction for the treatment of Mason II or III radial head and neck fractures. Materials and Methods: 13 patients (8 male, 5 female) with Mason II or III radial head and neck fractures were treated by 1 cm percutaneous mini-open reduction under fluoroscopy. The average age of our subjects was 29 years. Follow up duration was 18 months. Results: Union was noted in all cases. Mean radial neck angulation was decreased from 33.2 degrees to 7.8 degrees. The mean change in angulation between the immediate post-operative and last follow-up was 0.7 degrees. The mean range of motion at the elbow joint was at last follow up, 133.1 degrees in flexion, 7.3 degrees in extension, 80 degrees in pronation and 84.3 degrees in supination. Postoperatively, mean Mayo Elbow Performance Index, American Shoulder and Elbow Surgeons elbow score, and Disabilities of the Arm, Shoulder and Hand score were 96.2, 97 and 1.2. Temporary posterior interosseous nerve palsy (1 case) and minimal cubitus valgus deformity (1 case) were noted. Conclusion: Selected Mason II or III radial head and neck fractures can be treated satisfactorily with percutaneous mini-open reduction.

Total Elbow Arthroplasty after Failed Surgical Treatment for Elbow Fracture or Dislocation (주관절 골절 혹은 탈구의 실패한 수술적 치료 후 시행한 주관절 전 치환술의 결과)

  • Yi, Jin-Woong;Roh, Jun-Ha;Song, Jong-Hoon;Rhee, Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.190-198
    • /
    • 2007
  • Purpose: The current study reports the clinical results of total elbow arthroplasties (TEA) which were Performed on patients with poor clinical and radiological results after initial surgeries for elbow fractures or dislocations. Materials and Methods: The clinical outcomes of twelve consecutive patients who underwent TEA after failed surgeries for elbow fractures or dislocations from january, 1995 to December, 2005 were evaluated. The initial diagnoses were distal humeral fractures in 8 cases and fracture-dislocations in 4 cases. The Mean period from the initial operations to the TEAs was 12 months. The mean folloow up period after TEA was 43 months. Results: The mean range of motion, in terms of active extension, activeflexion, supination, and pronation, improved from $14.2^{\circ}$, $96.7^{\circ}$, $50.8^{\circ}$ and $53.3^{\circ}$ to $5.4^{\circ}$, $122.1^{\circ}$, $63.3^{\circ}$ and $67.5^{\circ}$, respectively (p<0.05). RAdiolucent lines were found in 3 cases, which were 1 case of type 3, and 2 cases of type 4. All three loosening cases underwent revision TEAs. The mean postoperative Mayo elvow performance score was 79 point. There were 6 cases of excellent, 2 cases of good, and 4 cases in poor. Conclusion: Good clinical results were obtained after TEA performed in failed surgeries for elbow fractures of dislocations.

Analysis of Anatomical Conformity of Straight Antegrade Humeral Intramedullary Nail in Korean (한국인에서의 직선형 전향적 상완골 골수 내 금속정의 해부학적 적합성 분석)

  • Choi, Sung;Jee, Seungmin;Hwang, Seongmun;Shin, Dongju
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.498-503
    • /
    • 2021
  • Purpose: The aim of this study were to find ideal entry point of straight antegrade humeral intramedullary nail (SAHN) for the treatment of proximal humerus fracture in Korean and to analyze anatomical conformity using computed tomography. Materials and Methods: From May 2014 to October 2016, the study was conducted retrospectively on 74 Korean patients who had taken computed tomography on both normal and affected shoulder joint as result of shoulder injury. The mean age of the patients was 64.5 years (range, 22-95 years). Radiologic evaluation was done using multiplanar reconstruction technique of the computer tomography on normal proximal humerus. We located ideal entry point of SAHN as the point where humerus intramedullary center axis and humeral head meet. Distance between the entry point and local anatomical landmark was measured. We defined the critical distance as the distance between entry point and the most medial point of the supraspinatus attachment site. For adequate fixation and avoidance of injury to rotator cuff, critical distance should be over 8 mm according to Euler, and we defined the critical type when it is less than 8 mm. Critical distance, sex, age, height, body weight, body mass index was evaluated for the statistical significance. Results: The ideal entry point was as follows: the mean anteroposterior distance, the sagittal distance to the lateral margin of bicipital groove, was 11.5 mm and the mean mediolateral distance, the coronal distance to the lateral margin of grater tuberosity, was 20.5 mm. The mean critical distance, distance from the entry point to the just medial to insertion of the supraspinatus tendon, was 8.0 mm. Critical type with critical distance less than 8 mm was found in 41 in 74 patients (55.4%). Conclusion: The ideal entry point of SAHN in Korean was located on 11.5 mm posteriorly from the lateral margin of bicipital groove and 20.5 mm medially from lateral margin of greater tuberosity. More than half of the cases were critical type. Since critical type can possibly cause rotate cuff injury during nail insertion on entry point, surgeon should consider anatomical variance before choosing surgical option.

The Clinical Outcomes of Arthroscopic Repair of Isolated type II SLAP Lesion in Non-athletes (비 운동선수에 있어 단독 제 2형 SLAP 병변의 관절경적 봉합수술의 임상적 결과)

  • Yoo, Jae-Chul;Ahn, Jin-Hwan;Koh, Kyoung-Hwan;Kim, Seung-Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.185-190
    • /
    • 2008
  • Purpose: The purpose of this study is to provide the clinical outcomes of arthroscopic type II SLAP repair in non-athletes, and to compare the clinical outcomes between those who had isolated type II SLAP lesion and those who had combined partial thickness supraspinatus tear that did not required a combined repair. Materials and Methods: From July 2005 to January 2007, 142 consecutive type II SLAP lesions were treated with arthroscopic surgery. The inclusion criteria for the study were; (1) younger than 50 years old; and (2) non-athletes. Exclusion criteria were; (1) prior surgery, fracture or combined recurrent dislocation history on the affected shoulder; (2) combined full thickness rotator cuff tear or PTST (>50% thickness) patient that needed repair; and (3) combined infection, arthritis or inflammatory disease. Remaining 19 patients meet the criteria. Among them, 13 had combined PTRCT that did not require repair (Group I), and 6 had isolated type II SLAP lesion without combined supraspinatus tear (Group II). The mean age was 36.7 years (29~49 years), mean symptom duration was 39.1 months (3~216 months) and mean follow-up was 19.0 months (12~27 months). In all patients, the range of motion of affected shoulder, pain and function visual analogue scale (PVAS, FVAS), the Constant score and UCLA score were evaluated preoperatively and postoperatively. Results: In group I, external rotation at side was decreased significantly (p=0.003),but there were no statistical significant change at the remains(p>0.05). And there were no differences between groups (p>0.05). At the final follow-up, all clinical outcome measurements improved after surgery with statistical significance (p<0.05): UCLA score, $22.8{\pm}5.2$ to $32.8{\pm}2.1$; Constant score, $79.4{\pm}8.6$ to $94.9{\pm}4.3$; PVAS $5.4{\pm}2.7$ to $1.1{\pm}1.4$; FVAS $63.2{\pm}15.3$ to $93.4{\pm}7.3$. But, in group comparison of the mean UCLA score and Constant score, there were no statistical significant differences between two groups. Conclusion: Arthroscopic repair of type II SLAP lesion provided good clinical outcomes in nonathletic population. Combined partial thickness supraspinatus tear does not seem to hamper the final outcome at minimal 1 year follow-up.

  • PDF

Polarus Intramedullary Nail for Nonunion of Humerus neck (Polarus 골수정을 이용한 상완골 경부 불유합의 수술적 치료)

  • Kang, Ho-Jung;Kim, Sul-Gee;Yoon, Hong-Kee;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.112-123
    • /
    • 2007
  • Purpose: Evaluate the clinical results of humerus neck nonunion treated with Polarus intramedullary nail. Materials and Methods: 8 patients who underwent surgery for nonunion of humerus surgical neck fracture were included. All patients were female, the average age was 65 years. 5 out the total 8 cases initially received surgery, open reduction and internal fixation with metal plate in 1 case, Ender nail insertion in 2 cases, external fixator in 1 case and closed reduction and percutaneous pinning in 1 case. The other 3 non union cases initial received conservative managemnent. The average period of nonunion was 9 months in the operated group and 6.2 months in the conservative group. All 8 cases received closed reduction with intrameedullary Polarus nail and auto iliac bone graft. Union was confirmed radiologically, and functional evaluation was done with the UCLA functional criteria. Results: All 8 cases showed union on radiologic evaluation. Average time to union was 3.5 months, average follow up period was 27 months. Average UCLA shoulder evaluation score was 7.6 points preoperatively which improved to 26.3 points after surgery. Active shoulder flexion was 40.7 degrees preoperatiely which increased to 104 degrees after surgery. Shoulder abduction improved from 32.9 degrees preoperatively to 96.3 degrees after surgery. UCLA functional criteria was good in 5 cases and fair in 3 cases, which no poor cases. Conclusion: Polarus IM nailing and AIBG is a useful method for treating nonunion of humerus neck fracture with improvement in union and function.

Shoulder Function after antegrade intramedullary interlocking nailing for humeral shaft fracture (상완골 간부 골절에 대한 선행성 교합 골수강내 금속정 고정술 후 견관절 기능)

  • Park, Jin-Young;Chun, Ji-Yong;Kim, Myung-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.27-36
    • /
    • 2003
  • Antegrade interlocking intramedullary nailing (AIIN) for the humeral shaft fracture can induce shoulder pain and decrease of shoulder function postoperatively. The purpose of this study was to estimate the outcome of the shoulder functions after AIIN through the rotator interval between the subscapularis and the supraspinatus to decrease the shoulder pain. Out of consecutive 43 cases that underwent AIIN 42 had been followed for two years or more. Among them we analysized 40 cases of 39 Patients excluding two cases of Pathologic fractures. The average was 47 years. There were 17 men and 23 women. The average follow-up was 34 months. Open nailing was performed in 26 fractures and closed nailing in 14. Bone graft was done in 7 fractures with open nailing. With a single operation, all but two patients achieved osseous union. Average pain score with visual analog scale was one (range; 0∼4) postoperatively By the Neer's score 37 patients received a excellent or satisfactory results while 3 patients' unsatisfactory or failed results. By the functional score of ASES (American Shoulder and Elbow Society) 6 cases received the fair or poor results. Except three cases with persistent nerve palsy and one case of technique failure with protruded nail over humeral head, all patients could achieved satisfactory results with Neer's score and 35 cases (94%) satisfactory results with functional score of ASES. An insertion of antegrade nail to the rotator interval was recommended for better shoulder functions and less pain postoperatively.

Operative Treatment with Locking Compression Plate (LCP) in Proximal Humerus Fracture (잠김 압박 금속판을 이용한 상완골 근위부 골절의 치료)

  • Ha, Sung-Sik;Kim, Jae-Young;Hong, Ki-Do;Sim, Jae-Chun;Kang, Jung-Ho;Park, Kwang-Hee
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.137-142
    • /
    • 2008
  • Purpose: To evaluate the clinical and radiographic results of the treatment of a proximal humerus fracture with a locking compression plate(LCP). Materials and Methods: This study reviewed the results of 24 cases of a proximal humerus fracture treated with a LCP from January 2005 to April 2007, after a follow up of more than 12 months. There were 8 males and 16 females with a mean age of 68.9(33-90) years. The clinical results were evaluated using the Neer's evaluation criteria, and the radiographic results were evaluated using the bone union time and Paavoleinen method. Results: The mean time for bone union was 11.9 weeks. Using the Neer's functional evaluation, 21 cases of the 24 patients (87%) showed excellent or satisfactory results. Twenty two cases (91%) showed good results according to the Paavoleinen method. The complications encountered were metal failure (1 patient), AVN of the humeral head (1 patient) and joint stiffness (1 patient). Conclusion: The LCP demonstrated good results in the treatment of a proximal humerus fracture and has relatively fewer complications than other internal fixators.

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

The Volar Plating of Fracture of the Coronoid Process - Report of Two Cases - (구상돌기 골절에서 내측 접근법을 통한 전방 금속판 고정술 - 2예 보고 -)

  • Jung, Gu-Hee;Cho, Chul-Hyun;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.260-265
    • /
    • 2010
  • Purpose: To report the clinical results of two cases of coronoid process fractures that were treated with volar plating through a medial approach. Materials and Methods: Two fractures of the coronoid process that needed to be fixed were managed with open reduction and internal fixation through a medial approach using 2.4 mm locking compression plates (Compact Hand set$^{(R)}$, Synthes, Switzerland). The patients were followed up for 14 months and 17 months and were evaluated using the Mayo Elbow Performance Score (MEPS). Results: The MEPS was 95 for Case 1 and 100 for Case 2. Active elbow joint motions were $5^{\circ}-120^{\circ}$ (Case 1) and $0^{\circ}-130^{\circ}$ (Case 2). Supination and pronation fully recovered. Conclusion: Satisfactory results can be obtained in cases of coronoid process fractures because volar plating through a medial approach allows sound fixation and early mobilization of the elbow joint.

Hook Plate Fixation for Unstable Distal Clavicle Fractures: A Prospective Study (불안정 원위 쇄골 골절의 치료에서 Hook 금속판을 이용한 전향적 연구)

  • Kim, Kyung-Cheon;Shin, Hyun-Dae;Cha, Soo-Min;Jeon, Yoo-Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.6-12
    • /
    • 2011
  • Purpose: We wanted to analyze and report on the radiologic and clinical results of prospective Hook plate fixation for unstable distal clavicle fractures after a minimum of 2 years follow up. Materials and Methods: We followed up 17 out of 20 cases that underwent prospective Hook plate fixation from 2008 to 2009. We performed radiologic follow up at 2 weeks, 6 weeks, 3 months, 6 months, 18 months and 24 months postoperatively. The clinical results were evaluated at 12 months and 24 months postoperatively. Results: The mean period for bony fusion was 14.5 weeks and the plate was removed after an average of 20.2 weeks. The VAS pain scores were 0.7 and 0.8, the UCLA scores were 33.5 and 33.3, the ASES scores were 92.8 and 92.5, the Constant-Murley scores were 81.5 and 77.0, the KSS scores were 92.5 and 94.3 and the ranges of motion were $173.3^{\circ}$ and $173.7^{\circ}$ of flexion, $56.0^{\circ}$ and $54.5^{\circ}$ of external rotation, $62.3^{\circ}$ and $63.5^{\circ}$ of the internal rotation, $172.0^{\circ}$ and $172.6^{\circ}$ of abduction and $43.3^{\circ}$, and $42.9^{\circ}$ of extension at 1 and 2 years follow-up, respectively. There was no statistically significant difference of clinical outcomes and the range of motion at 1 year and 2 year postoperatively (p>0.05). There was no other complication except 1 case of delayed union. Conclusion: For Hook plate fixation at 2 years postoperatively, the complications will be decreased and excellent clinical results should occur.