• Title/Summary/Keyword: 격자이론

Search Result 297, Processing Time 0.027 seconds

A Computational Mineralogy Study of the Crystal Structure and Stability of Aluminum Silicate (Al2SiO5) Minerals (알루미늄 규산염(Al2SiO5) 광물의 결정구조와 안정성에 대한 계산광물학 연구)

  • Kim, Juhyeok;Son, Sangbo;Kwon, Kideok D.
    • Journal of the Mineralogical Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.13-22
    • /
    • 2018
  • Aluminum silicates ($Al_2SiO_5$) undergo phase transitions among kyanite, andalusite, and sillimanite depending on temperature and pressure conditions. The minerals are often used as an important indicator of the degree of metamorphism for certain metamorphic rocks. In this study, we have applied classical molecular dynamics (MD) simulations and density functional theory (DFT) to the aluminum silicates. We examined the crystal structures as a function of applied pressure and the corresponding stabilities based on calculated enthalpies at each pressure. In terms of the lattice parameters, both methods showed that the volume decreases as the pressure increases as observed in the experiment. In particular, DFT results differed from experimental results by much less than 1%. As to the relative stability, however, both methods showed different levels of accuracy. In the MD simulations, a transition pressure at which the relative stability between two minerals reverse could not be determined because the enthalpies were insensitive to the applied pressure. On the other hand, in DFT calculations, the relative stability relation among the three minerals was consistent with experiment, although the transition pressure was strongly dependent on the choice of the electronic exchange-correlation functional.

Development of High Strength Lattice Girder and Evaluation of Its Performance (고강도 격자지보재의 개발 및 그 성능 평가)

  • Lee, Jae-Won;Min, Kyong-Nam;Jeong, Ji-Wook;Roh, Byoung-Kuk;Lee, Sang-Jin;Ahn, Tae-Bong;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.43-57
    • /
    • 2020
  • The objective of this study was to evaluate the performance of high-strength lattice girders as a possible superior alternative to conventional steel arch ribs. For this purpose, the structural characteristics of supports were analyzed using numerical analysis, and their performance was evaluated using maximum bending load tests and tensile tests of the welded joint. According to the results of structural analysis, the optimum size of the upper and lower members and plates is 50 mm × 31.8 mm × 25.4 mm, demonstrating excellent functionality and economic efficiency. High-strength lattice girders of dimensions 55 mm × 30 mm × 20 mm and 85 mm × 30 mm × 20 mm, determined from bending load tests, are found to meet both the reference values and the target values of H-profiles 100 and 125. A review of the ratio of theoretical deflection to actual deflection shows that the high-strength lattice girder developed during this study meets fewer than five of the evaluation criteria for lattice girder deflections proposed by the Federal Railway Department of Germany. Finally, tensile test results reveal that the welded joint of the high-strength lattice girder at the main steel bar-auxiliary steel bar-plate junction exceeds the target value, indicating that the welded joint has sufficient stability.

Stabilization Characteristics of the Diffusion Flame Formed in the Wake of Bluff Body with Fuel Injection (연료분출을 수반하는 보염기 후류에 형성되는 확산화염의 보염특성)

  • 안진근
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.223-232
    • /
    • 2001
  • To study the stabilization characteristics of diffusion flame formed in the wake of a cylindrical bluff body with fuel injection, the flame stability limits, length and temperature of recirculation zone of flame, turbulence intensity distribution near the recirculation zone of flame were measured and analyzed. The length of recirculation zone is independent on main fuel injection quantity, but it is dependent on fuel injection angles, air stream velocity, and auxiliary fuel injection into recirculation zone. For diffusion flame, in general, the flame stabilization is deteriorated with increase of he length of recirculation zone, but if the turbulence generator is installed, the flame stabilization is improved with increase of the length of recirculation zone. The temperature of recirculation zone is dependent on fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators, and it dependent on fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators, and it has a maximum value at the condition of each theoretical mixture. In general, the more temperature of recirculation zone is low, the more flame is stable. But when the turbulence generator is installed, the more temperature of recirculation zone is low, the more flame is unstable. The turbulence intensity in the wake of bluff body is increased with increase of diameter or blockage ratio of grid. The more turbulence intensity is increased by installation of turbulence generator, the more flame is unstable. Finally, It is clear that the stabilization characteristics of diffuser flame can be controlled by some parameters such as fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators.

  • PDF

Characteristics of Thermal Coefficient of Fiber Bragg Grating for Temperature Measurement (온도 측정을 위한 광섬유 브래그 격자 센서의 온도 계수 특성 평가)

  • Kim, Heon-Young;Kang, Donghoon;Lee, Jin-Hyuk;Kim, Dae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.999-1005
    • /
    • 2013
  • A fiber Bragg grating sensor is considered a smart sensor that shows outstanding performance in the field of structural health monitoring (SHM). It has a powerful advantage, especially that of multiplexing, which enables several parameters to be sensed at multiple points by using a single optical fiber line. Among several parameters, the thermal expansion coefficient and thermo-optic coefficient are required to measure temperature. In previous studies, these were considered constant variables. This study shows that two parameters vary with temperature and newly proposes a temperature function for these two parameters. Specifically, these two parameters were defined as a single variable, and then, it was experimentally verified that this variable is a function of temperature. Finally, it was shown that temperature from RT to $100^{\circ}C$ was precisely measured by using the temperature function that was defined through the experiment.

Analysis on performance of grid-free compressive beamforming based on experiment (실험 기반 무격자 압축 빔형성 성능 분석)

  • Shin, Myoungin;Cho, Youngbin;Choo, Youngmin;Lee, Keunhwa;Hong, Jungpyo;Kim, Seongil;Hong, Wooyoung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.179-190
    • /
    • 2020
  • In this paper, we estimated the Direction of Arrival (DOA) using Conventional BeamForming (CBF), adaptive beamforming and compressive beamforming. Minimum Variance Distortionless Response (MVDR) and Multiple Signal Classification (MUSIC) are used as the adaptive beamforming, and grid-free compressive sensing is applied for the compressive sensing beamforming. Theoretical background and limitations of each technique are introduced, and the performance of each technique is compared through simulation and real experiments. The real experiments are conducted in the presence of reflected signal, transmitting a sound using two speakers and receiving acoustic data through a linear array consisting of eight microphones. Simulation and experimental results show that the adaptive beamforming and the grid-free compressive beamforming have a higher resolution than conventional beamforming when there are uncorrelated signals. On the other hand, the performance of the adaptive beamforming is degraded by the reflected signals whereas the grid-free compressive beamforming still improves the conventional beamforming resolution regardless of reflected signal presence.

Diffraction Analysis of Multi-layered Grating Structures using Rigorous Equivalent Transmission-Line Theory (정확한 등가 전송선로 이론을 사용한 다층 격자 구조의 회절특성 분석)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.261-267
    • /
    • 2015
  • The eigenvalue problems involving the diffraction of waves by multi-layered grating configurations can be explained by rigorous modal expansion terms. Such a modal solution can be represented by equivalent transmission-line networks, which are generalized forms of simple conventional circuits. This approach brings considerable physical insight into the grating diffraction process of the fields everywhere. In particular, the transmission-line representation can serve as a template for computational algorithms that systematically evaluate dispersion properties, radiation effects and other optical characteristics that are not readily obtained by other methods. To illustrate the validity of the present rigorous approach, the previous research works are numerically confirmed and the results agree well each other.

Hydrological Assessment of Multifractal Space-Time Rainfall Downscaling Model: Focusing on Application to the Upstream Watershed of Chungju Dam (멀티프랙탈 시·공간 격자강우량 생산기법의 수문학적 적용성 평가 : 충주댐상류유역 중심으로)

  • Song, Ho Yong;Kim, Dong-Kyun;Kim, Byung-Sik;Hwang, Seok-Hwan;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.959-972
    • /
    • 2014
  • In this study, a space-time rainfall grid field generation model based on multifractal theory was verified using nine flood events in the upstream watershed of Chungju dam in South Korea. For this purpose, KMA radar rainfall data sets were analyzed for the space-time multifractal characteristics. Simulated rainfall fields that represent the multifractal characteristics of observed rainfall field were reproduced using the space-time rainfall grid field generation model with log-Poisson distribution and three-dimension wavelet function. Simulated rainfall fields were applied to the S-RAT model as input data and compared with both observed rainfall fields and low-resolution rainfall field runoff. Error analyses using RMSE, RRMSE, MAE, SS, NPE and PTE indicated that the peak discharge increases about 20.03% and the time to peak decreases about 0.81%.

Implementation of Highly Efficient GMR Color Filter using Asymmetric Si3N4 Gratings (비대칭 Si3N4 격자를 사용한 고효율 GMR 컬러 필터의 구현)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.225-230
    • /
    • 2017
  • In this paper, a highly efficient GMR(guided-mode resonant) color filter is proposed and implemented. The GMR color filter consists of $Si_3N_4/air$ layers containing complementary fixed and mobile gratings. The device is designed using RETT(rigorous equivalent transmission-line theory) and a grating structure operating in subwavelength. The numerical result reveals that the color filter has a tuning capability of about 35 nm over the $0.45{\mu}m{\sim}0.55{\mu}m$ range for blue-green color and across $0.6{\mu}m{\sim}0.7{\mu}m$ range for red color. Furthermore, The color filters have a spectral bandwidth of about 8 nm with efficiencies of 99%, 98%, and 99% at the center wavelength of blue, green, and red color, respectively, and these are higher efficiencies than reported in the literature previously.

GaAs로 덮인 InAs/InGaAs 양자고리의 비정상 응력 분포 및 이방 응력에 의한 light-hole 분율 증가

  • Mun, Pil-Gyeong;Park, Gwang-Min;Yun, Ui-Jun;Choe, Won-Jun;Leburton, Jean-Pierre
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.89-90
    • /
    • 2010
  • 최근 우리는 InGaAs 위에 성장한 InAs 양자점에 GaAs를 얇게 덮음으로써 양자고리를 성장하고, 그 광학적 특성을 분석하였다. [1] 이번 연구에서는 이 양자고리 구조의 전자 구조 및 광학적 특성을 전산모사를 통해 계산하였고, GaAs가 구조의 응력, 압전 포텐셜 및 light-hole 분율에 미치는 영향을 분석하였다. 이론적인 분석을 위해, valence force field 방법을 이용하여 이종 물질간의 격자상수 차이에 의한 격자 변형 및 압전 포텐셜의 변화를 계산하였고, 양자고리 내 전자의 양자화 에너지 및 파동함수를 k p 방법을 통해 얻을 수 있었다. 또한 광학적인 특성 등의 다체 효과를 예측하기 위해 configuration interaction 방법을 사용하였다. 이 연구에서 우리는, GaAs가 InAs에 강한 압축 응력을 가할 것이라는 일반적인 예측과 달리, InGaAs 매트릭스 안에서는 격자상수가 작은 GaAs가 InAs 양자고리에 효과적인 압축 응력을 가할 수 없음을 보였다. 특히 GaAs 층의 두께가 얇을 경우, InGaAs 매트릭스에 의해 인장 응력을 받는 GaAs가 InAs의 응력을 해소하기 충분한 공간을 제공하여, 오히려 InAs의 압축 응력을 약화시키는 것을 알 수 있었다. 이 연구 결과는 응력 분포가 단순한 양자우물 등의 2차원 구조와 달리, 응력 분포가 복잡한 3차원 나노 구조에서는 단순히 격자상수만으로 파장 변화 경향을 예측할 수 없음을 나타낸다. 또한 우리는, GaAs의 큰 negative 이방 응력과 InAs의 작은 positive 이방 응력에 의해 전자와 heavy-hole은 InAs에, light-hole은 GaAs에 구속됨을 보였다. 즉, InAs보다 밴드갭이 큰 GaAs가 전자와 heavy-hole에 대해서는 강한 포텐셜 배리어로 작용하지만 light-hole에 대해서는 포텐셜 우물로 작용하는, 반 우물-반 배리어 특성을 가짐을 알 수 있었다. 이로 인해 GaAs가 있는 양자고리의 light-hole 분율이 GaAs가 없을 경우에 비해 2배에서 8배가량 증가함을 보일 수 있었다. 비슷한 특성이 hole에 대해서는 InP나 InGaAsP 위에 성장한 GaAs 층에서 보고된 바가 있으나, 전자는 InAs로, hole은 GaAs로 분리할 수 있는 3차원 나노 구조에 대한 연구는 이 연구가 처음이다. [2]

  • PDF

A Study on the Heat Transfer Analysis of High-Temperature Single Bubble in Water (수중 고온 단일 기포의 열전달 해석 연구)

  • SeokTae Yoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.29 no.1
    • /
    • pp.117-123
    • /
    • 2024
  • Bubbles generated in water receive an upward buoyant force due to the density and pressure difference of the surrounding fluid. Additionally, the behavior, shape, and heat exchange process of bubbles vary depending on the viscosity, surface tension, rising speed, and size difference with the surrounding fluid. In this study, we modeled speed, and heat transfer of a high-temperature single bubble rising in a cylindrical water tank. For this purpose, velocity, and temperature of the bubbles were calculated using theoretical equations, to be compared with numerical simulation results. The numerical analysis was performed using a commercial software, and the stability of the numerical analysis with mesh size was confirmed through calculation of the grid convergence index. The numerical analysis of the rising speed and temperature of a single bubble showed the values to converge when the minimum cell size was 1/160 of the bubble diameter, and the temperature decrease was confirmed to be the same as that of the surrounding fluid within 0.05 seconds.