• Title/Summary/Keyword: 게이트 SPECT

Search Result 59, Processing Time 0.024 seconds

The Effects of Discrepancy in Reconstruction Algorithm between Patient Data and Normal Database in AutoQuant Evaluation: Focusing on Half-Time Scan Algorithm in Myocardial SPECT (심근 관류 스펙트에서 Half-Time Scan과 새로운 재구성법이 적용된 정상군 데이터를 기반으로 한 정량적 분석 결과의 차이 비교)

  • Lee, Hyung-Jin;Do, Yong-Ho;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.122-126
    • /
    • 2014
  • Purpose: The new reconstruction algorithms (NRA) provided by vendor aim to shorten the acquisition scan time. Whereas depending on the installed version AutoQuant program used for myocardial SPECT quantitative analysis did not contain the normal data that NRA is applied. Thus, the purpose of this paper is to compare the results according to AutoQuant versions in myocardial SPECT applied NRA and half-time scan (HT). Materials and Methods: Rest Tl and stress MIBI data of total 80 (40 men, 40 women) patients were gathered. Data were applied HT acquisition and ASTONISH (Philips) software which is NRA. Modified autoquant of SNUH and old version of AutoQuant (full-time scan) provided by company were compared. Comparison groups were classified as coronary artery disease (CAD), 24 hrs delay and almost normal patients who have a simple pain patient. Perfusion distribution aspect, summed stress score (SSS), summed rest score (SRS), extent and total perfusion deficit (TPD) of each 25 patient who have above diseases were compared and evaluated. Results: The case of CAD, when using re-edited AutoQuant (HT) SSS and SRS showed about 30% reduction (P<0.0001), Extent showed about 38% reduction and TPD showed about 30% reduction in the tendency (P<0.0001). In the score of the perfusion, especially on the part of infero-medium, infero-apical, lateral-medium and lateral-apical regions were the biggest change. The case of the 24 hrs delay patient SRS (P=0.042), Extent (P=0.018) and TPD (P=0.0024) showed about 13-18% reduction. And the case of simple pain patient, comparison of 4 results showed about 5-7% reduction. Conclusion: This study was started based on expectation that results could be affected by normal patient data. Normal patient data is possible to change by race and gender. It was proved that combination of new reconstruction algorithm for reducing scan time and analysis program according to scan protocol with NRA could also be affected to results. Clinical usefulness of gated myocardial SPECT is possibly increased if each hospital properly collects normal patient data for their scan acquisition protocol.

  • PDF

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

Effects of Scatter Correction on the Assessment of Myocardial Perfusion and Left Ventricular Function by gated Tc-99m Myocardial SPECT (게이트 Tc-99m 심근관류 SPECT에서 산란보정이 심근관류 및 좌심실기능평가에 미치는 영향)

  • Jeong, Hwan-Jeong;Son, Hye-Kyung;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • Purpose: The purpose of this study was to evaluate the effect of scatter correction on the assessment of myocardial perfusion and left ventricular function by gated Tc-99m myocardial SPECT. Materials and Methods: Subjects were 11 normal volunteers, 20 patients with non-cardiac chest pain and 13 patients with coronary artery diseases. We classified above 3 groups into normal and diseased groups. Scatter correction was done using dual-energy-window scatter correction method (DEW-SC). We compared acquired counts, image contrast, corrected maximum relative counts, indices of left ventricular function, extent and severity of perfusion defects calculated by 'CEqual program' between scatter non-corrected and corrected images. Results: Scatter corrected studios was lower in counts by $18{\pm}3%$ than uncorrected studies, but image contrast were improved in all cases. Scatter correction using DEW-SC took 3 minutes to complete, and 512 kB memory to store. There were no significant differences among indices of left ventricular function between scatter non-corrected and corrected images. Although extents of perfusion defects were not significantly different, severity was severer in scatter corrected images. Conclusion: Scatter correction using DEW-SC is simple to do, and improves image contrast without changing other indices of myocardial perfusion and function.

  • PDF

Improvement in Regional Contractility of Myocardium after CABG (관상동맥 우회로 수술 환자에서 심근의 탄성도 변화)

  • Lee, Byeong-Il;Paeng, Jin-Chul;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.224-230
    • /
    • 2005
  • Purpose: The maximal elastance ($E_{max}$) of myocardium has been established as a reliable load-independent contractility index. Recently, we developed a noninvasive method to measure the regional contractility using gated myocardial SPECT and arterial tonometry data. In this study, we measured regional $E_{max}(rE_{max}$ in the patients who underwent coronary artery bypass graft surgery (CABG), and assessed its relationship with other variables. Materials and Methods: 21 patients (M:F=17:4, $58{\pm}12$ y) who underwent CABG were enrolled. $^{201}TI$ rest/dipyridamole stress $^{99m}Tc$-sestamibi gated SPECT were performed before and 3 months after CABG. For 15 myocardial regions, regional time-elastance curve was obtained using the pressure data of tonometry and the volume data of gated SPECT. To investigate the coupling with myocardial function, preoperative regional $E_{max}$ was compared with regional perfusion and systolic thickening. In addition, the correlation between $E_{max}$ and viability was assessed in dysfunctional segments (thickening <20% before CABG). The viability was defined as improvement of postoperative systolic thickening more than 10%. Results: Regional $E_{max}$ was slightly increased after CABG from $2.41{\pm}1.64 (pre)\;to\;2.78{\pm}1.83 (post)$ mmHg/ml. $E_{max}$ had weak correlation with perfusion and thickening (r=0.35, p<0.001). In the regions of preserved perfusion (${\geq}60%$), $E_{max}$ was $2.65{\pm}1.67$, while it was $1.30{\pm}1.24$ in the segments of decreased perfusion. With regard to thickening, $E_{max}$ was $3.01{\pm}1.92$ mmHg/ml for normal regions (thickening ${geq}40%$), $2.40{\pm}1.19$ mmHg/ml for mildly dysfunctional regions (<40% and ${\geq}20%$), and $1.13{\pm}0.89$ mmHg/ml for severely dysfunctional regions (<20%). $E_{max}$ was improved after CABG in both the viable (from $1.27{\pm}1.07\;to\;1.79{\pm}1.48$ mmHg/ml) and non-viable segments (from $0.97 {\pm}0.59\;to\;1.22{\pm}0.71$ mmHg/ml), but there was no correlation between $E_{max}$ and thickening improvements (r=0.007). Conclusions: Preoperative regional $E_{max}$ was relatively concordant with regional perfusion and systolic thickening on gated myocardial SPECT. In dysfunctional but viable segments, $E_{max}$ was improved after CABG, but showed no correlation with thickening improvement. As a load-independent contractility index of dysfunctional myocardial segments, we suggest that the regional $E_{max}$ could be an independent parameter in the assessment of myocardial function.

Therapeutic Angiogenesis by Intramyocardial Injection of pCK-VEGF165 in Pigs (돼지에서 pCK-VEGF165의 심근내 주입에 의한 치료적 혈관조성)

  • Choi Jae-Sung;Han Woong;Kim Dong Sik;Park Jin Sik;Lee Jong Jin;Lee Dong Soo;Kim Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.323-334
    • /
    • 2005
  • Background: Gene therapy is a new and promising option for the treatment of severe myocardial ischemia by therapeutic angiogenesis. The goal of this study was to elucidate the efficacy of therapeutic angiogenesis by using VEGF165 in large animals. Material and Method: Twenty-one pigs that underwent ligation of the distal left anterior descending coronary artery were randomly allocated to one of two treatments: intramyocardial injection of pCK-VEGF (VEGF) or intramyocardial injection of pCK-Null (Control). Injections were administered 30 days after ligation. Seven pigs died during the trial, but eight pigs from VEGF and six from Control survived. Echo-cardiography was performed on day 0 (preoperative) and on days 30 and 60 following coronary ligation. Gated myocardial single photon emission computed tomography imaging (SPECT) with $^{99m}Tc-labeled$ sestamibi was performed on days 30 and 60. Myocardial perfusion was assessed from the uptake of $^{99m}Tc-labeled$ sestamibi at rest. Global and regional myocardial function as well as post-infarction left ventricular remodeling were assessed from segmental wall thickening; left ventricular ejection fraction (EF); end systolic volume (ESV); and end diastolic volume (EDV) using gated SPECT and echocardiography. Myocardium of the ischemic border zone into which pCK plasmid vector had been injected was also sampled to assess micro-capillary density. Result: Micro-capillary density was significantly higher in the VEGF than in Control ($386\pm110/mm^{2}\;vs.\;291\pm127/mm^{2};\;p<0.001$). Segmental perfusion increased significantly from day 30 to day 60 after intramyocardial injection of plasmid vector in VEGF ($48.4\pm15.2\%\;vs.\;53.8\pm19.6\%;\;p<0.001$), while no significant change was observed in the Control ($45.1\pm17.0\%\;vs.\;43.4\pm17.7\%;\;p=0.186$). This resulted in a significant difference in the percentage changes between the two groups ($11.4\pm27.0\%\;increase\;vs.\;2.7\pm19.0\%\;decrease;\;p=0.003$). Segmental wall thickening increased significantly from day 30 to day 60 in both groups; the increments did not differ between groups. ESV measured using echocardiography increased significantly from day 0 to day 30 in VEGF ($22.9\pm9.9\;mL\;vs.\;32.3\pm9.1\;mL;\; p=0.006$) and in Control ($26.3\pm12.0\;mL\;vs.\;36.8\pm9.7\;mL;\;p=0.046$). EF decreased significantly in VEGF ($52.0\pm7.7\%\;vs.\;46.5\pm7.4\%;\;p=0.004$) and in Control ($48.2\pm9.2\%\;vs.\;41.6\pm10.0\%;\;p=0.028$). There was no significant change in EDV. The interval changes (days $30\~60$) of EF, ESV, and EDV did not differ significantly between groups both by gated SPECT and by echocardiography. Conclusion: Intramyocardial injection of pCK-VEGF165 induced therapeutic angiogenesis and improved myocardial perfusion. However, post-infarction remodeling and global myocardial function were not improved.

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

Lung Uptake of $^{99m}Tc-sestamibi$ during Routine Gated Exercise SPECT Imaging : Comparison with Left Ventricular Ejection Fraction and Severity of Perfusion Defect (일상적인 운동 부하 게이트 심근 관류 SPECT에서 $^{99m}Tc-sestamibi$ 폐섭취 : 좌심실 구혈률과 관류 결손 정도와의 비교)

  • Jeong, Shin-Young;Lee, Jae-Tae;Bae, Jin-Ho;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.83-93
    • /
    • 2003
  • Background: Lung-to-heart uptake ratio (LHR) in $^{201}Tl-chloride$ myocardial perfusion scan is believed to be a reliable marker for left ventricular (LV) dysfunction, but the clinical value of LHR is controversial for $^{99m}Tc-MIBI$ imaging. Furthermore, most of results suggesting lung uptake of $^{99m}Tc-MIBI$ as a potential marker for LV dysfunction used immediate post-stress images, instead of routine images acquired 1 hour after tracer injection. The goal of our study was to investigate whether LHR evaluated with routine gated $^{99m}Tc-MIBI$ imaging can reflect the degree of perfusion defect or left ventricular performance. Subjects and Methods: 241 patients underwent exercise $^{99m}Tc-MIBI$ myocardial SPECT were classified into normal myocardial perfusion (NP, n=135) and abnormal myocardial perfusion (AP, n=106) group according to the presence of perfusion defect. LHR was calculated from anterior projection image taken at 1-hour after injection. Two legions of interest (ROIs) were placed on left lung above LV and on myocardium showing the highest radioactivity. Subjects were classified by left ventricular ejection fraction (LVEF), as Gr-I: >50%, Gr-II: 36-50%, Gr-III: <36% and by summed stress score (SSS), as Gr-A: <4, Gr-B: 4-8, Gr-C: 9-13, Gr-D: >13, LHR was compared among these groups. Results: In NP group(n=135), LHR, were higher in men than women ($men:\;0.311{\pm}0.03,\;women:\;0.296{\pm}0.03,\;p<0.05$). Significant difference, in LHR were found between NP and AP groups both for men and women ($men:\;0.311{\pm}0.03\;vs\;.\;0.331{\pm}0.06,\;women:\;0.296{\pm}0.03\;vs.\;0.321{\pm}0.07.\;p<0.05$). There were weak negative correlation between LHR and LVEF (r=-0.342, p<0.05) and weak positive correlation between LHR and SSS (r=0.478, p<0.05) in men, but not in women (LVEF: r=-0.279, p=0.100, SSS: r=0.276, p=0.103). Increased LHR was defined when for more than mean + 2SD value ($men{\geq}0.38,\;women{\geq}0.37$) of the LHR of the subject with normal perfusion. Increased LHR were observed more frequently in subjects with lower LVEF (Gr-I: 11.1%, Gr-II: 27.0%, Gr-III: 35.4%, p<0.05) and higher SSS(Gr-A: 14.0%, Gr-B: 5.7%, Gr-C: 18.2%, Gr-D: 40.7%, p<0.05). Conclusions: LHRs obtained from routine $^{99m}Tc-MIBI$ gated SPECT images were weakly correlated with LVEF and perfusion defect. Although significant overlaps were observed between normal and abnormal perfusion group, LHRs could be used as an indirect marker of severe perfusion defect or reduced left ventricular function.

Usefulness of Posture Change to Prevent Overlapping of Heart and Other Organs in Myocardial Perfusion SPECT using $^{99m}Tc$ Labeled Compound ($^{99m}Tc$ 표지화합물을 사용한 심근 관류 SPECT 검사에서 심장과 타 장기와의 중첩 방지를 위한 자세 변화의 유용성)

  • Lee, Dong-Hyuk;Oh, Shin-Hyun;Jeong, Seok;Jo, Seok-Won;NamKoong, Hyuk;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • Purpose: The present study has an objective of effectively separating and making observations on a portion of radiopharmaceutical excreted via digestive organ to remain in the organ and invade a heart shadow. Materials and methods: When heart shadow is blocked by the organ in tests during a resting phase and a loaded phase, additional images were obtained using immobilization device. The immobilization devices were used to tilt the upper body forward from supine position. Results: In the reconstructed image for the separated case, as compared with the case where a part of organ is overlapped with heart, in terms of an overall mean value for each parameter, the end-diastolic volume increased by 2.75 mL, the end-systolic volume decreased by 3.16 mL, the left ventricle cardiac coefficient increased by 3.58%, and the area of defect region decreased by 3.58 and 3.92 cm for loading and resting phase, respectively. Conclusions: In the present study with myocardial perfusion SPECT, overlapped areas of heart and other organs could be effectively separated and visualization by the use of an immobilization device.

  • PDF

Difference of Time Course of Functional Recovery after Revascularization According to Preoperative Reversibility of Perfusion Impairment in Ischemic Myocardial Dysfunction (허혈성 심근 기능장애에서 술전 관류결손의 가역성에 따른 재관류 시술 이후 심근 기능회복 양상의 시간적 차이)

  • Paeng, Jin-Chul;Lee, Dong-Soo;Kim, Ki-Bong;Kim, Yu-Kyeong;Yeo, Jeong-Seok;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.364-370
    • /
    • 2001
  • Purpose: In the revascuarization of ischemic dysfunctional myocardium, stunned myocardium was reported to recover function earlier than hibernating myocardium. It was also suggested that stunning and hibernation could be discriminated by reversibility of perfusion impairment on myocardial SPECT. In this study, we investigated the time course of functional recover after CABG according to reversibility of perfusion impairment. Materials and Methods: In 92 patients with coronary artery disease, Tl-201 rest/dipyridamole stress Tc-99m-MIBI gated SPECT was performed before, 3 months after, and 17 months after CABG. Using a 20-segment model, segmental perfusion and systolic thickening were automatically quantified. Perfusion-impaired segments with abnormal thickening were classified by reversibility into reversible (REV) and irreversible (IRREV) groups. The proportions of function-recovered segments were compared between groups and also between 3 months and 17 months in each group. Results: A total of 129 segments were Included In the analysis, and 76 were REV and 53 were IRREV. At 3 months after CABG, 61 segments (80%) in REV group showed functional recovery while 28 segments (53%) in IRREV group did (p<0.001). However, at 17 months after CABG, 60 segments (79%) in REV group and 37 segments (70%) un IRREV group showed functional recovery (p=n.s.). When comparing 3 months and 17 months in each group, REV group showed no difference, while IRREV group showed significant further improvement (p<0.05). Conclusion: In viable myocardium with ischemic myocardial dysfunction, the segments with reversible perfusion impairment recover function earlier after revascularization than irreversible segments.

  • PDF