• Title/Summary/Keyword: 검지관

Search Result 24, Processing Time 0.027 seconds

Freeway Bus-Only Lane Enforcement System Using Infrared Image Processing Technique (적외선 영상검지 기술을 활용한 고속도로 버스전용차로 단속시스템 개발)

  • Jang, Jinhwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.5
    • /
    • pp.67-77
    • /
    • 2022
  • An automatic freeway bus-only lane enforcement system was developed and assessed in a real-world environment. Observation of a bus-only lane on the Youngdong freeway, South Korea, revealed that approximately 99% of the vehicles violated the high-occupancy vehicle (HOV) lane regulation. However, the current enforcement by the police not only exhibits a low enforcement rate, but also induces unnecessary safety and delay concerns. Since vehicles with six passengers or higher are permitted to enter freeway bus-only lanes, identifying the number of passengers in a vehicle is a core technology required for a freeway bus-only lane enforcement system. To that end, infrared cameras and the You Only Look Once (YOLOv5) deep learning algorithm were utilized. For assessment of the performance of the developed system, two environments, including a controlled test-bed and a real-world freeway, were used. As a result, the performances under the test-bed and the real-world environments exhibited 7% and 8% errors, respectively, indicating satisfactory outcomes. The developed system would contribute to an efficient freeway bus-only lane operations as well as eliminate safety and delay concerns caused by the current manual enforcement procedures.

The Combustion Gases Toxicity Evaluation of Plastics Material by Colorimetric Gas Detector Tubes (가스검지관법에 의한 플라스틱재료의 연소가스 독성평가)

  • 박영근;김동일;현성호
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.77-84
    • /
    • 2002
  • In this paper, we had analyzed comsbustion gases using a GASTEC colorimetric gas detector tube according to the method of NES 713 in order to combustion gases toxicity evaluation for beads polystyrene foam, extruded polystyrene foam, rigid polyurethane foam, flexible polyurethane foam, flexible polyvinyl chloride pipe, vinyl floor cover, polyethyelene foam(flame retardant untreated) and polyethyelene foam (flame retardant treated) of plastics material. As results of gas analyses by using this method, comsbustion gases producted from small specimens of plastics material had reached fatal to man at 30 minutes exposure time that had possesed toxicity index of more than 1. Toxicity indexes of each specimen were estimated range of 4.3∼179.2, flexible polyvinyl chloride showed the hightest toxicity index at 179.2, and beads polystyrene foams showed the lowest toxicity index at 4.3.

Cryocoolers for cooling of HTS RF Filter and IR detector (초전도필터 및 적외선검지기 냉각용 극저온냉동기)

  • 홍용주
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.11
    • /
    • pp.18-23
    • /
    • 2002
  • 고품질의 극저온 환경의 생성 및 유지는 고품질 대용량 정보통신, 의료진단, 초전도 및 고집적반도체 제조공정 등의 차세대 유망 산업 분야에서 필수적인 요소로 자리 잡고 있으며, cryopump, 민수용 및 군수용의 적외선 검지기 및 초전도 RF 필터의 효과적 냉각을 위해 보다 높은 신뢰성과 수명, 고효율의 극저온 냉동기에 대한 수요는 점차 증대될 것으로 기대된다. 스터링 냉동기 및 맥동관 냉동기는 짧은 역사에도 불구하고, 다양한 분야에서 기존의 한제 및 극저온 냉동기를 대치하여 활용될 수 있을 것으로 전망된다.

A Study on Combustion Patterns of Flammable Liquids by Contained Oil Test (담유 실험에 의한 인화성 액체의 연소 패턴 해석에 관한 연구)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.14-20
    • /
    • 2014
  • The purpose of this study is to analyze combustion patterns by filling a specific container with a flammable liquid and performing combustion tests in a divided space. The container used for the test is made of plastic, 20 mm in depth and 150 mm in width. After the liquid was ignited, its combustion process was photographed using a digital camera and video camera. It was found that in the case of benzene, the flame reached its peak at the fastest speed about 60 s while in the case of alcohol, the flame reached its peak at the lowest speed about 360 s, which is approximately six times slower than the benzene. In most cases, when the flame reached its peak, smoke generated was dark as the plastic container and flammable liquid were combusted simultaneously. After completion of the combustion, it was possible to sample oil vapor from all flammable liquids excluding soybean oil as a result of the examination of oil vapor using a crime investigation tube. That is, it can be seen that there is significant difference in flame propagation speed, pattern, etc., depending on the combustible substances.

Characteristics of Ammonia in Alkaline Stabilization Facility of Sludge from Sewage Treatment Plant (하수처리오니 알칼리 안정화 처리시설에서의 암모니아 발생특성)

  • Kim, Yong-Jun;Chung, David;Jeong, Mi-Jeong;Yoo, Hye-Young;Yoon, Cheol-Woo;Shin, Sun-Kyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.23-33
    • /
    • 2016
  • The characteristics of ammonia generated from alkaline stabilization facilities was investigated which are for organic sewage sludge from wastewater treatment plants. The highest concentration of ammonia was found in mixing and curing process in alkaline stabilization facility and ammonia mainly showed a range of 87.78 ppm($66.62mg/m^3$) to 1,933 ppm($1,467.01mg/m^3$) by detection tube. This is presumed to occur because nitrogen oxides are converted into ammonia as the sewage sludge is mixed with lime. In some facilities, hydrogen sulfide and methyl mercaptan were detected in relatively high concentrations, but odor materials except ammonia were not detected in most of the facilities. The concentration of ammonia caused by process was generally high in the order of "mixing > curing > output > storage > drying > input." It was found that odor compounds are removed by wet absorption using sulfuric acid and sodium hypochlorite in the 5 alkaline stabilization facilities currently in operation. Each facility was designed to meet the concentration of after-treatment emission in 1 ppm($0.76mg/m^3$), 50 ppm($37.95mg/m^3$) or 100 ppm($75.89mg/m^3$), but no facility satisfied the design standard for their emssion limit. In case of ammonia, some workplaces in alkaline stabilization facilities exceeded the exposure limits established by the Ministry of Labor. It appears that proper ventilation should be provided for the safety of workers in future. No odor compound including ammonia was found by detection tubes in the border of the facilities, but trace amounts of odor compounds are expected to exist, given the current operational status of facilities.

Reaction Characteristics of Kaolinite-based Additives and Alkali Salts (Kaolinite 계열의 첨가제와 알칼리염의 반응 특성)

  • Jun, HyunJi;Choi, Yujin;Shun, Dowon;Han, Keun-Hee;Bae, Dal-Hee;Rhee, Young-Woo
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.221-227
    • /
    • 2020
  • When the waste solid fuel (SRF, Bio-SRF) is burnt in a boiler, a problem occurs in the combustion process involving the alkali components (Na, K) contained in large amounts in the fuel. The alkaline component has a low melting point, which usually forms low melting point salt in the temperature of the furnace, with the resulting low melting point salts attaching to the heat pipe to form a clinker. Various additives are used to suppress clinker generation, and the additive based on the kaolinite has alkali-aluminum-silica to inhibit the clinker. In this study, the reactivity of the additives based on the kaolinite was compared. The additives utilized were R-kaolinite, B-kaolinite, and A-kaolinite. Also silica and MgO were sourced as the comparison group. The experimental group was employed as a laboratory-scale batch horizontal reactor. The additive and alkaline salts were reacted at a weight ratio of 1 : 1, and the reaction temperature was performed at 900 ℃ for 10 hours. The first measurement of HCl occurring during the experiment was performed 30 minutes after the detection tube was used, and the process was repeated every hour after the experiment. After the reaction, solid residues were photographed for characterization analysis by means of an optical microscope. The reaction characteristics of the kaolinite were confirmed based on the analysis results.

A Study on the Emission of VOCs in Parking Lot Floor Coating (주차장 바닥 코팅제의 휘발성유기화합물 배출에 관한 연구)

  • Lee, Seung-Chan;Yoon, Gil-Ho;Park, Yong-Soon;Kil, Bae-Su;Yoon, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.152-158
    • /
    • 2019
  • Measure the type and content of VOCs for A-company epoxy coating and B-company floor coating(Type A, B), which are used as flooring materials for parking lots. Than the VOCs used gas detectors to measure gas emissions, assuming the worst environment to reduce errors in external environments in the formaldehyde, toluene and xylene harmful to workers and tenants. As a result, A-company epoxy coating has the largest amount of VOCs, and compared to A-company epoxy coating, B-company floor coating of A type represented about 79% less and B type about 96% less. In addition, A-company epoxy coating was also the highest in gas emission measurement for formaldehyde, toluene and xylene using gas detector after 1 hour and 8 hours in closed environment conditions. B-company floor coating A type was less than A-company epoxy coating, which was about 42.3% less measured. And type B satisfied all TWA even in closed environment conditions.

하계 전기, 전자연합학술회의 및 산학협동 심포지엄 초록

  • 대한전기학회
    • 전기의세계
    • /
    • v.27 no.5
    • /
    • pp.33-54
    • /
    • 1978
  • (차례) 1.산학협동심포지업 (1)우리나라에서의 연구개발과 산학협동 (2)산학협동과 산업계의 역할 (3)산학협동의 현황과 진로 2.학술회의A (1)전력게통의 계층구조와 협조원리에 관한 연구 (2)2중층괴상회전자 유도전동기의 이론해석 (3)초고주파가열장치에 사용하는 철공진변압기의 해석적 설계 (4)한국전기기시험연구소 대전력단락 시험설비설계 (5)직류전동기제어를 위한 Thyristor Chopper정류회로에 관한 연구 (6)선로의 개폐정보를 포함하는 전력계통의 상태추정 (7)단일신경세포에 대한 ITEM 신호 특성 3.학술회의B (1)MMM-1 Computer System의 설계 및 제작 (2)Adaptive Delta Modulation System의 성능비교 연구 (3)6GHZ FMD마이크로파 무선전송장치의 개발 (4)적선도에 의한 회로망함수의 결정 (5)동맥혈압의 해석과 그의 전기적 유사모델 (6)피부감각의 정보전달 특성에 관하여 (7)선형직접회로의 공정설계 및 그 특성 조성 (8)DH L.D의 전기적포화현상에 관한 이론적 해석 (9)Potocoupler를 이용한 Isolator 4.학술회의C (1)Al-Al$_{2}$O$_{3}$ -Al박막구조의 전기적 특성 (2)이종금속에 샌드위치된 고분자물질의 단락전조 (3)유전체가 일부체워진 직 6면체의 캐비티의 다중모오드 해석 (4)반도체 가스 검지소자의 제조 및 그의 전기적 특성 (5)실리콘 산화공정에 대한 실험적 고찰 (6)진공증착법에 의한 InSb 박막제도에서 열처리효과 (7)(Ba$_{1}$-xBix) Tio$_{3}$ PTC thermistor의 첨가량의 최적건안 (8)금속박막증착시 두께조절 5.특별강연회 (1)일본에 있어서의 절력계통공학연구 (2)Linear Motor의 최근개발동향량도 높았다. valine과 leucine 및 aspartic acid, glycine과 glutamic acid, leucine과 aspartic acid 간에는 고도의 정상관, glycine과 serine, valine과 phenylalanine, threonine과 proline, phenylalanine과 arginine, methionine과 glutamic acid, histidine과 lysine 간에는 유의 정상관, 그리고 isoleucine과 lysine 간에는 유의한 부상관이 있었다. 4. lysine 함량은 단백질 함량과 정산곤, isoleucine 함량은 단빅질 함량과 부상관을 보였으며, alanine, valine, leucine 함량은 지방함량과 각각 유의한 정산관을 보였다. 5. 대두 단백질은 7.5% acrylamide gel 전기영동에 의해 품종에 따라 12~16개의 구성분으로 분리되었으며, 이들중 주구성분들은 상대이동도가 0.06(a), 0.14(b). 0.24(d) 이었고, 구성분 b의 함량이 품종간에 가장 변이가 컸으며, 구성분 b는 그밖의 주요 구성분들의 함량과 부의 상관이 있었고, 구성분 a는 단백질 함량과 정상관이 있었다. 6. 종실단백질 구성분들의 조합 특성 면에서 공시 86품종은 11개 유형군으로 분류되었으며, 우리나라와 일본품종은 미국품종에 비해 단백질구성분 조성이 훨씬 다양하였다. 7. 이동도가 매우 빠른 단백질 구성분 o(Rm 0.77) p(Rm 0.81)를 모두 갖고 있는 품종은 3품종, 모두 갖고 있지 않은 품종은 1품종이었고, 나머지 82품종은 o나 p중 한 구성분을 갖고 있었으며 그 분포율은 30 : 65 이었는데 미국계 품종은 우리나라 품종에 비해 구성분 o를 간고 있는 비율이 현저히 적었다. 8. 대두 종실은 개화후 22일까지 완만히, 그 이후 20~30일간 급속히

  • PDF

Effect of Reducing the Odor of Food Wastes Using Effective Microorganism (EM) (유용미생물을 활용한 음식물쓰레기의 악취저감 효과)

  • Kim, Ha-Na;Yim, Bongbeen;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.4
    • /
    • pp.162-168
    • /
    • 2016
  • The aim was to investigate the effect of reducing the odorous and complex odor released during the decomposition of food wastes using effective microorganism (EM) as a function of time at $20^{\circ}C$ and $35^{\circ}C$. The variation of total microbial counts and dominant species counts in EM and leachate produced during food wastes decomposition was also observed. In general, the cumulative concentration of sulfur compounds ($H_2S$, $CH_3SH$) and complex odor released during food wastes decomposition increased with increasing elapsed time. The nitrogen compounds ($NH_3$, trimethyl amine), however, was not observed in all samples. The addition of EM in food wastes resulted in the reduction of concentration of sulfur compounds and complex odor, in spite of the increase of $CH_3CHO$ concentration. The dominant microbial species detected in EM were Lactobacillus species(Lactobacillus rhamnosus and Lactobacillus casei). In the leachate produced during food wastes decomposition, however, the various microbial community alternative to that detected in EM was observed. The EM could be potentially useful as a tools for reducing odor induced from the food waste decomposition process.

A Study on Experimental Characteristics in Fire Investigation Techniques of Flammable Liquids (유류화재의 감식기법의 실험적 특성에 관한 연구)

  • Hwang, Taeyeon;Choi, Donmook
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.7-14
    • /
    • 2012
  • This paper is to develop analytical techniques of flammable liquids which have been used for accelerating fire in accidental fires and arsons. We tested the temperature distribution of ceiling, fire patterns on the floor, and existence of flammable liquids and a check with GC/MS about flammable liquids comparing with papers, newspapers, and clothing. Research findings are as follows. The temperature of ceiling is influenced by flame. So gasoline and thinner was observed that combustible materials would be burned by flame. The fire patten on the floor was observed that flammable liquids had specialized pattern comparing combustible materials. When combustible materials on the PVC (Polyvinyl chloride) floor was burned, they didn't react to the gas detector. But flammable liquids had opposite results. After 7 days, we identified components of fire residues with the GC/MS (Gas Chromatography/Mass Spectrometry) about existence of flammable liquids and got components of flammable liquids. Fire investigation is a complicated processes. But we understand characteristics of materials, need detail investigations, and use the GC/MS to analyse flammable materials.