• Title/Summary/Keyword: 검사 시간

Search Result 3,829, Processing Time 0.047 seconds

Validation of Neurobehavioral Tests for Occupational Screening(NTOS) : results of patients of Parkinson's disease (Neurobehavioral Tests for Occupational Screening의 타당도 평가 : 파킨슨병 환자들의 검사 성적)

  • Lee, Chae-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.577-584
    • /
    • 1997
  • Validation and Standardization of neurobehavioral instrument in Korean occupational setting has not been studied ever. This study tried to validate the newly developed computerized psychomotor tests, Neurobehavioral Tests for Occupational Screening (NTOS). Male patients with Parkinson's disease(n=12) and male workers who never exposed to occupational neurotoxic materials and didn't have neurologic disease(n=21), performed some tests from NTOS; simple reaction time, choice reaction time(2 choice), and finger tapping(both hands). In simple analysis, difference between patient group and worker group was significantly great. Adjusted for age and education years, simple reaction time and finger tapping(both hand) were statistically significantly different between two groups(p<.05). Choice reaction time was also different(p<.1) but error frequency of choice reaction time test was not. Generally, this results showed NTOS could detect impairment of psychomotor function. But insensitive results of choice reaction time was partly due to small sample size and confounding variables and so required future study and refinement at improvement of NTOS.

  • PDF

Memory Profiling Checkpoint (메모리 프로파일 검사점)

  • 허준영;김상수;홍지만;조유근
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04a
    • /
    • pp.196-198
    • /
    • 2003
  • 검사점(checkpoint) 오버헤드를 최소화하는 검사점 주기(interval)를 결정하는 것은 결함 허용 시스템(fault tolerant system)에서 검사점 알고리즘과 관련된 많은 연구들의 중요한 목표 중의 하나이다. 검사점을 드물게 하게 되면 실패 후에 재수행 하는데 너무 많은 시간이 필요하게 된다. 반면에, 너무 자주하게 되면 검사점 오버헤드가 커지고 프로그램의 총 실행시간에 영향을 주게 된다. 이 논문에서는 적응성 있는(adaptive) 시계열 (time series) 분석을 사용하여 검사점 간격을 동적으로 조절할 수 있는 메모리 프로파일 검사점 간격 알고리즘을 제안한다. 트레이스에 기반한 시뮬레이션 실험 결과에서. 제안한 동적인 검사점 주기 알고리즘이 고정적인 검사점 주기 알고리즘보다 전체 검사점 오버헤드가 더 작고, 최적의 검사점 간격에 훨씬 근접했음을 알 수 있었다.

  • PDF

A Study On Temperature Changes In Thigh According To Diagnostic Ultrasonography Scan Time (진단용 초음파 검사시간에 따른 허벅지의 온도 변화에 관한 고찰)

  • Kim, Ji-Won;Lim, Hyun-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.201-206
    • /
    • 2012
  • Effect of prenatal ultrasound diagnosis have serious damage for the possibility has been reported very low. Long time ultrasound scan can rise the temperature in body tissues and affect the physical. Changes in body temperature have been studied with ultrasound scan time. Fetal ultrasonography were evaluated without the influence of time. The findings, ultrasound scan time in 40 minutes the temperature was reduced. 50 minute tissue temperature rose more than $1^{\circ}C$. If within 40 minutes of ultrasound to be safe guess

Deep Learning-based Automated Detection of Radio-Opaque Markers in X-Ray Images (딥러닝 기반 방사선 비투과성 표지자 자동 검출 기법)

  • Song, Youngmin;Lee, Byoung-Dai
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.06a
    • /
    • pp.40-43
    • /
    • 2017
  • 본 논문은 딥러닝을 이용하여 대장통과시간(Colon Transit Time, CTT) 검사를 위한 단순복부 X-Ray 영상에서 방사선 비투과성 표지자(Radio-opaque Marker)를 자동으로 검출하는 기법을 제시한다. 대장통과시간 검사는 대장의 운동질환을 평가하는데 있어 가장 기본적인 방법으로 특히 만성 변비증 환자의 병태생리에 따른 유형 분류와 치료 계획을 설정하는데 큰 도움을 주고 있으며, 내과적 또는 외과적 치료 후 평가에도 유용한 검사이다. 대장통과시간 검사는 방사선 비투과성 표지자가 내재되어 있는 캡슐을 복용한 뒤 주기적으로 단순복부 X-Ray 촬영을 통해 구간별로 남아있는 표지자의 수를 세고, 이를 통해 구역별 통과시간을 측정한다. 이 과정에서 판독의가 직접 표지자의 위치 및 개수를 세기 때문에 많은 시간이 필요하게 된다. 따라선 본 논문에서는 이러한 단점을 보완하기 위해 딥러닝 기법을 사용하여 X-Ray 영상 내에서 표지자의 위치를 자동 파악하는 기법을 제시한다.

  • PDF

A Study on measurement blood velocity according to variable changing in magnetic resonance phase contrast image (자기공명 위상대조도 기법에서 병렬영상기법 변화에 따른 혈류정량 측정에 관한 연구)

  • Cho, yong-bum;Yang, seon-wook;Son, soon-yong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.107-108
    • /
    • 2017
  • 3차원 위상대조도 기법의 단점인 긴 검사시간으로 인해 임상적 유용성이 떨어진다. 본 논문은 시간매개변수인 병렬영상기법(Grappa) 변경에 따른 혈류정보의 정량적 평가를 통해 차이점을 알아보고 임상적 활용정도를 평가하였다. 자체 제작한 혈류팬텀을 통해 실험하였으며, Grappa을 5번 변경하여 실험하였다. 연구결과, Grappa를 적용하지 않았을 경우 혈류속도는 평균 9.42로 총 4단계를 적용한 혈류속도 차이율은 각각(1.4, 1.5, 0.4, 1.5%)이었으며 flow와 WSS도 각각(1.4, 1.6, 0.8, 25%), (2.1, 1.4, 1.1, 0.8%)이었다. 통계적으로도 유의하지 않아 Grappa를 적용하지 않은 검사법과 혈류정보가 동일하였다.(P>0.05) 긴 검사 시간으로 인해 임상적 활용이 떨어지는 짧은 검사시간을 요하는 소아환자나 중등도 환자 또는 폐쇄공포증 환자에게 시간을 단축한 3차원 위상대조도 기법을 사용하여 단점을 보완한다면 임상적 활용가치가 높아질 것이라 사료된다.

  • PDF

Diffusion Weighted Imaging in Musculoskeletal MRI: Analysis on Optimal Number of Excitations Providing better Differentiation of Maglignant Tumor (악성종양의 감별진단을 위한 근골격의 확산강조영상 검사 시 최적의 여기횟수)

  • Choi, Kwan-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.338-344
    • /
    • 2018
  • The purpose of this study was to determine the optimal number of excitations(NEX) of diffusion weighted imaging(DWI) which is clinically useful in patients with musculoskeletal diseases while the scan time is relatively long. In this study, 30 patients underwent knee MRI using diffusion weighted image sequence using b values targeted on the bone and muscle. The NEX were varied from 1 to 5 and the ADC values were measured and analyzed. As a result of the study, 4 NEX and 2 NEX showed an statistically identical effect with the existing NEX on the bone and muscle diffusion weighted images, respectively. Also, it proved that the scan time could be significantly reduced by 21.2 % and 59.6 % compared to the established NEX which meant the optimal NEX could replace the existing NEX. In conclusion, applying the optimal NEX on the musculoskeletal bone and soft tissue DWI could improve the problems caused by the long scan time.

RTL Design Scan Rule Checker Based On Symbolic Simulation (심볼릭 시뮬레이션 기법을 이용한 RTL 스캔 설계 법칙 검사기)

  • 이종훈;민형복
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10c
    • /
    • pp.31-33
    • /
    • 2001
  • 전통적으로 스캔 설계 법칙 검사는 게이트 레벨에서 수행되었다. 그러나 RTL 설계와 합성 도구의 사용이 일반화되면서 게이트 레벨 회로의 검사는 합성 단계에서의 최적화와 스캔 설계 법칙 위배를 정정한 후의 최적화가 필요하여 많은 시간이 소요된다. RTL에서의 스캔 설계 법칙 검사는 이러한 문제를 해결할 수 있으며, 이것이 본 논문의 주제이다. 본 논문에서는 스캔 설계 법칙의 위배를 RTL 설계에서 검사할 수 있는 기법을 제안한다. 이 기법은 효과적인 설계 과정에 의해 설계 시간 을 단축할 수 있을 것이다.

  • PDF

Improvement of Ray-Tacing Performance by Using Object Pre-Proessing (오브젝트 전처리에 의한 광선추적법 속도 개선)

  • 김범수;황선태
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.565-567
    • /
    • 1999
  • 3D 그래픽의 실사 이미지를 표현하기 위해 사용되는 광선추적법은 알고리즘상 빛과 물체의 충돌을 검사하는데 대부분의 시간이 소모된다. 보다 빠른 광선추적법을 수행하기 위해 빛과 물체의 충돌 검사시간을 줄이는 것이 요구된다. 이를 위해 본 논문에서는 디자인 시 설정된 오브젝트를 바로 랜더링 하는 방법보다 오브젝트와 카메라의 거리, 오브젝트와 월드의 상대적 크기를 고려한 바운딩 볼륨을 설정하도록 전처리해 빛과 물체의 충돌 검사 시간을 줄임으로서 광선추적법 알고리즘을 빨리 수행하는 방법을 제시한다.

  • PDF

Studies on the Observation of Sperm Morphology and Sperm Concentration Using Unopette in Cattle and Dog (소 및 개에 있어서 Unopette를 사용한 정자형태 및 정자농도의 검사)

  • 김명철
    • Journal of Embryo Transfer
    • /
    • v.6 no.1
    • /
    • pp.41-45
    • /
    • 1991
  • 소와 견에 있어서 Unopette가 정자의 형태학적 검사 및 정자농도의 검사를 위하여 사용될 수 있는가를 알아 보기 위하여본 연구를 수행하였다. 소정액 및 견정액을 Unopette에 희석한 후 3-5$^{\circ}C$에 보존하면서 시간경과에 따라서 위상차현미경하에서 관찰하여 다음과 같은 결과를 얻었다. 1. Unopette를 사용하여 관찰한 정자는 48시간까지는 hematoxylin-eosin을 사용하여 정자보다는 높은 정상정자율을 나타내넜다. 2. Unopette를 사용한 정자는 정자농도에 있어서 대조군 정자에 비하여 24시간까지는 큰 차이를 나타내지 않았다. 3. 따라서 Unopette는 정자의 형태학적 검사 및 정자농도의 검사를 위하여 유용하게 사용될 수 있다는 사실을 알 수 있었다.

  • PDF

Comparison between 24 hr pH Monitoring and Esophageal Scintigrapy in Children Presenting with Gastroesophageal Reflux Symptoms (식도 동위 원소 검사와 24시간 식도 pH 검사와의 비교 연구)

  • Wi, Ho Sung;Kim, Yong Joo;Seol, In Joon;Choi, Yun Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.2
    • /
    • pp.163-169
    • /
    • 2004
  • Purpose: Many diagnostic modalities have been used for diagnosis of gastroesophageal reflux disease (GERD). Feeding materials during esophageal pH monitoring may interfere the result of examination and esophageal pH monitoring can not diagnose GER in case of alkaline reflux. The purpose of our study is to evaluate whether scintigraphy can substitiute 24 hr pH monitoring in children with GERD. Methods: From March 2002 to June 2003, 23 patients (12 boys and 11 girls, mean age 27 months) who have been admitted to Hanyang University Hospital presented with GER symptoms (recurrent vomiting, cough, chest pain, irritability) were included in the study. Scintigraphy and 24 hr pH monitoring were performed in all patients. Results: Six out of the 23 patients (26.1%) had evidence of GER on 24 hr pH monitoring, whereas nine of 23 patients (39.2%) exhibited GER by scintigraphy. Two out of the 23 patients could not be tested because of irritability. Three (14.3%) patients had evidence of GER on both 24 hr pH monitoring and scintigraphy, three (14.3%) patients on only 24 hr pH monitoring, six (28.6%) patients on only scintigraphy, and nine (42.9%) patients had no evidence of GER on both methods. No correlation was observed between 24 hr pH monitoring and scintigraphic results by Fisher's exact test (p=0.523) or Kendal's tau (t=0.678). Conclusion: The results of this study demonstrated that there was no correlation between 24 hr pH monitoring and scintigraphy. Therefore these modalities could be used as complementary tests to diagnose GERD.

  • PDF