• Title/Summary/Keyword: 검사 결과

Search Result 16,660, Processing Time 0.048 seconds

Qualitative and Quantitative Analysis of Paper-Pencil Test Items for Exploring its Appropriateness as a Selection Tool of the Gifted in Science (과학 영재 선발 도구로서 지필 검사의 적합성 탐색을 위한 질적 및 양적 문항 분석)

  • Lee, Ki-Young;Dong, Hyo-Kwan;Hong, Jun-Eui;Kim, Hyun-Kyung;Jo, Bong-Jae
    • Journal of The Korean Association For Science Education
    • /
    • v.28 no.1
    • /
    • pp.32-46
    • /
    • 2008
  • The purpose of this study was to analyse the qualitative and quantitative characteristics of paper-pencil tests for exploring its appropriateness as a selection tool of the gifted in science. For this purpose, we developed two (internal and external) item analysis frameworks, and applied these frameworks to analyse qualitative characteristics. Also, we analysed the relationship between two characteristics. The results of analysing qualitative characteristics revealed that the portion of items with acceleration context exceeding middle school curriculum level was relatively large, which caused low content validity. Furthermore, there was considerable deviation in content and context by subject matter and year, which caused test unstability. Items measuring knowledge domain was the most prevalent, and too much weight on data interpretation & analysis domain in inquiry process skills. In case of creativity test, the portion of items measuring convergent thinking was much larger than that of divergent or associative thinking. Most of these items were represented by using pictures and tables rather than using graphs. Item types of multiple-choice and short answers were superior to essay types. Discrimination index, on the whole, was appropriate (above 0.3), but item difficulty showed a vast deviation ($0.01{\sim}0.90$). Correlation coefficients among subject matters and test tools were very low, and test reliabilities were also low. Low item difficulty & high discrimination index item types were distinguishable. Items with acceleration context were more discriminating than enrichment context. Implications of developing quality paper-pencil test items in the selection of gifted students are discussed.

Statistical Analysis of the IAEA-WHO Liver Phantom Images for the Asian Countries (아시아국가에서 IAEA-WHO 간모형 영상처리에 관한 통계학적 고찰)

  • Hong, Seong-Woon;Kang, Tae-Woong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.11-17
    • /
    • 1986
  • 핵의학기기중 scintillation gamma camera의 임상적 유용도는 이미 잘 알려져 왔으며 80년대에 들어와서는 Computer의 도입으로 그이용도가 더욱 확대되어 보유댓수가 급격한 증가를 이루게 되었다. 따라서 이에 대한 정도관리가 필요하게 되었다. 정도관리의 목적은 장비기능의 정상여부를 조기에 발견하여 항상 균등한 질의 영상을 재현하여 보다 정확한 진단을 하는데 있다. 따라서 r-camera의 사용자는 기계의 기능과 성능을 항상 정화하게 파악하여 빠르고 적절한 대책을 세워 양질의 영상을 얻도록 해야한다. 또한 스캔의 결과도 판독자 환자대상군, 검사방법에 따라 천의 예민도 및 특이도가 달라지며 정확도 또한 공간점유병소의 위치, 원인, 병소수의 크기에 따라 달라진다고 하였다. 저자는 이점을 감안하여 대상군, 검사방법 병소위치에 의한 변화를 배제하고 판독자의 검출정확도를 알아보고자 IAEA-RCA 협조를 얻어 IAEA-WHO 제공 간모형 (SALP: simulatied anatomic liver phantom)을 사용하여 국내 16개 병원 핵의학과 staff 20명에게 의뢰하여 얻은 결과와 아시아 8개국의 276명의 결과를 함께 분석하여 다음과 같은 결론을 얻었다. 1) 각개인의 간모형영상의 판독 정확도는 $60%\sim100%$ 사이었고 대부분 90% 내외였다. 2) 아시아 태평양지역의 정확도는 유럽 및 라틴아메리카의 결과와 비슷하였다. 3) 각 나라별의 정확도 결과는 91.1%에서 76.4%를 나타내었다. 4) 스캔너를 사용한 영상의 판독결과와 감마 카메라의 영상판독결과는 차이가 없었다. 5) 정도관리빈도와 정도관리검사방법은 영상판독 정확도의 결과와는 무관 하였다.

  • PDF

Irritant Contact Dermatitis in a Dog (개에서 발생한 자극성 접촉성 피부염 1례)

  • Kang, Jong-Il;Park, Jeong-Ho;Lee, Wang-Hee;Oh, Tae-Ho;Cho, Sung-Whan;Park, Seong-Jun
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.607-609
    • /
    • 2011
  • A 6-year-old, neutered female, Cocker spaniel presented with severe abdominal erythema and crusts. These conditions developed 1 month ago. This patient had a history of using humectant spray for several months. Irritant contact dermatitis was diagnosed by history, clinical signs, laboratory and histopathologic examinations (H-E stain). Complete blood count and serum chemistry showed no remarkable findings. Histopathologic examination of skin samples revealed parakeratosis accompanied by acanthosis of the dermis and mild perivascular inflammations of the superficial dermis. Clinical signs were improved after avoidance of suspected offending substance.

Analysis on Characteristics of Defects before Inspection for Apartment Use (공동주택 사용검사 전 하자 특성 분석)

  • Lee, Sang-Hyo;Han, Man-Cheon;Kim, Jae-Jun;Lee, Jeong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.167-178
    • /
    • 2020
  • The purpose of this paper is to establish a defect classification system for defects before inspection and to derive the pattern and characteristics of defects before inspection by examining about 3,110 defect items for 133 apartment buildings. The study analysis revealed a relatively high rate of defects before inspection that occurred in finishing work. Second, defects occurred such as cracking of external wall, which is a very important defect. However, defects before inspection were relatively rare on the external wall. Finally, defects before inspection occurred during waterproofing in the common area or garage. It is necessary to establish a reasonable basis or countermeasure to resolve differences between stakeholders as various issues may arise in the course of a dispute, as a result of identifying the details of defects within the top 20 of the defectives.

Development of Urine Strip for Detection of Leukocytes in Urine using Peroxidase (과산화효소를 이용한 백혈구 측정용 뇨 검사지 제조에 관한 연구)

  • 송은영;이홍수;김희정;김종완;최인성;변시명;정태화
    • Biomedical Science Letters
    • /
    • v.2 no.2
    • /
    • pp.199-209
    • /
    • 1996
  • A new test strip to detect leukocytes using the myeloperoxidase in urine was developed. The reagent strip contains tetramethylbenzine, glucose and glucose oxidase. The detection limit was between 10 cells per 1$\mu$l urine(5 cells/hpf), showing greenish yellow color in the range of 10-25 cells/$\mu$l, green color in the range of 75-250 cells/$\mu$l, greenish blue color in the range of 500 cells/$\mu$l. The result can be obtained within two minute. The performance of the new method was evaluated by comparing the results of microscopic examination and other commercial products. Good correlations were shown between the values obtained by our urine strip and those by other commercial products with 172 urine samples. The results were proven that new methods were useful as primary screening reagents to detect leukocytes in urine.

  • PDF

Acoustic Masking Effect That Can Be Occurred by Speech Contrast Enhancement in Hearing Aids (보청기에서 음성 대비 강조에 의해 발생할 수 있는 마스킹 현상)

  • Jeon, Y.Y.;Yang, D.G.;Bang, D.H.;Kil, S.K.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.1 no.1
    • /
    • pp.21-28
    • /
    • 2007
  • In most of hearing aids, amplification algorithms are used to compensate hearing loss, noise and feedback reduction algorithms are used and to increase the perception of speeches contrast enhancement algorithms are used. However, acoustic masking effect is occurred between formants if contrast is enhanced excessively. To confirm the masking effect in speeches, the experiment are composed of 6 tests; test pure tone test, speech reception test, word recognition test, pure tone masking test, formant pure tone masking test and speech masking test, and for objective evaluation, LLR is introduced. As a result of normal hearing subjects and hearing impaired subjects, more making is occurred in hearing impaired subjects than normal hearing subjects when using pure tone, and in the speech masking test, speech reception is also lower in hearing impaired subjects than in normal hearing subjects. This means that acoustic masking effect rather than distortion influences speech perception. So it is required to check the characteristics of masking effect before wearing a hearing aid and to apply this characteristics to fitting curve.

  • PDF

Structure and Fatigue Analyses of the Inspection Equipment Frame of a Semiconductor Test Handler Picker (반도체 테스트 핸들러 픽커 검사장비 프레임에 대한 구조 및 피로해석)

  • Kim, Young-Choon;Kim, Young-Jin;Kook, Jeong-Han;Cho, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.5906-5911
    • /
    • 2014
  • Currently, there are many processes of package assembly and inspections of real fields that examine whether a manufactured semiconductor can be operated regularly and can endure low humidity or high temperatures. As the inspection equipment of a semiconductor test handler picker has been used at the inspection process, these inspection equipment frames were modelled in 3D and these models were analyzed using 3 kinds of fatigue loadings. As the analysis result, maximum deformation occurred at the midparts of the frames at cases 1 and 2. Among the cases of nonuniform fatigue loads, the 'SAE bracket history' with the severest change in load became the most unstable but the 'Sample history' became the most stable. Fatigue analysis result can be used effectively with the design of an inspecting equipment frame of a semiconductor test handler picker to examine the prevention and durability against damage.

Comparative Study of Target Genes and Protocols by Country for Detection of SARS-CoV-2 based on Polymerase Chain Reaction (PCR) (중합효소 연쇄반응 기반의 코로나-19 바이러스 검출법에 대한 국가별 목표 유전자 및 프로토콜 비교 연구)

  • Kim, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.1
    • /
    • pp.465-474
    • /
    • 2021
  • Corona-19, a disease caused by 'Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)', was declared a global pandemic by the World Health Organization (WHO) in March 2020, and a real-time polymerase chain reaction test is performed as a diagnostic test for screening and confirmation in most countries. However, not only the target genes and protocols differ by countries, but also the procedures for reading the diagnosis results are diverse, so the criteria for confirmed patients differ by country. Therefore, in this review, we discussed the target genes, test techniques, and diagnostic criteria for each country notified by WHO. And the specificity and sensitivity, limits of detection, positive and negative controls, false positive bacteria candidates, and specimens, and the specifics of the control setting were also described. In addition, the characteristics of Korea's test were compared to each country's one. Finally, in order to obtain the same diagnosis result for SARS-CoV-2 in the future, standardized diagnosis methods and result interpretations for Corona-19 diagnosis were proposed.

Cervical Vascular Diseases Rarely Observed by Duplex Sonography: 3 Cases (이중초음파에서 드물게 관찰되는 목 부위의 혈관질환: 3례)

  • Han, Minho;Seo, Kangsik;Choi, Junghye
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.131-136
    • /
    • 2021
  • Duplex sonography is used widely in various medical fields because of its repeatability and low cost. In particular, the carotid duplex sonography is a useful non-invasive test for diagnosing cerebrovascular disease and predicting the prognosis. In clinical practice, it is very important to reduce the test time and improve accuracy. The patient's clinical information must be known in advance to perform carotid duplex sonography quickly and accurately. Despite this, there are often difficulties finding new cervical vascular diseases that are not mentioned in the clinical information. Therefore, knowing a variety of cases can lead to fast and accurate results. In this context, this paper reports three cases of cervical vascular disease discovered unexpectedly during carotid duplex sonography: CASE 1, internal carotid artery occlusion and cerebral arteries branched from the external carotid artery; CASE 2, internal jugular vein thrombosis; CASE 3, microembolism observed in the vertebral artery.

Factors Affecting the Intention of Acceptance of the COVID-19 Antibody Test (코로나19 항체검사 수용의도에 영향을 미치는 요인)

  • Yeojoo Chae
    • Journal of Industrial Convergence
    • /
    • v.21 no.6
    • /
    • pp.53-60
    • /
    • 2023
  • The purpose of this study is to identify the subjective health status, COVID-19 risk perception, antibody knowledge, social influence, intention of acceptance of the COVID-19 antibody test for general adults and the factors affecting the acceptance of the COVID-19 antibody test. The subjects of the study were 147 adults, and the collected data were analyzed using the SPSS 27.0 program using the frequency, percentage, average and standard deviation, independent t-test, ANOVA, pearson's correlation coefficients, and multiple regression analysis. The results, the acceptance of the COVID-19 antibody test has a significant static correlation with the social influence, the COVID-19 risk perception, and the negative correlation with the subjective health. The factor affecting the acceptance of the COVID-19 antibody test of the general adult was a social influence, and their explanatory power was 50.2%. As a result of this study, COVID-19 antibody tests may be used by preparing effective measures to prevent the spread of the COVID-19 infection.