• Title/Summary/Keyword: 건 이식술

Search Result 108, Processing Time 0.027 seconds

Stress Patterns in the Reconstructed Double Bundles of the Anterior Cruciate Ligament in Response to an Anterior Tibial Load and Rotatory Load: an Analysis using a 3-Dimensional Finite Element Model (삼차원 유한 요소 모델을 이용한 전방십자인대 이중다발 재건술 후 전방 전위 및 회전 부하에 따른 이식건 응력 양상 분석)

  • Seo, Young-Jin;Song, Si Young;Ahn, Jung Tae;Kim, Yoon-Sang;Ko, Jun Ho;Jang, Seong-Wook;Yoo, Yon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.160-166
    • /
    • 2012
  • Purpose: The aim of this study was to determine the patterns of the stress distribution within the reconstructed anterior cruciate ligament (ACL) double bundles in response to an anterior tibial load and rotatory load at $45^{\circ}$ flexed knee model by use of a 3-dimensional finite element analysis (FEM). Materials and Methods: The $0^{\circ}$ and $45^{\circ}$ flexed 3-D knee model were reconstructed based on the high resolution computed tomography (CT) images from the right knee of a healthy male subject. To simulate double bundle ACL reconstruction, in $0^{\circ}$ analytic model, four 7 mm diameter tunnels were created at the center of each anteromedial (AM) and posterolateral (PL) footprints on the femur and tibia. The grafts were inserted into the corresponding bone tunnels and then reconstructed knee model was flexed to $45^{\circ}$. As a next step, the 5 mm anterior tibial load and internal rotational load of $10^{\circ}$ were applied on the final Computer aided design (CAD) model. And then stress patterns of each bundle were assessed using a finite element analysis. Results: In response to the 5 mm of anterior tibial load, the AM bundle showed increased stresses around the tibial and femoral attachment sites; especially in the anterior aspect of the bundle. In the PL bundle, the highest stress concentration was also noticed on the anterior aspect of the bundle. Under $10^{\circ}$ internal rotational load, the stress concentration was predominant around the anterior aspect of the tibial attachment site within the AM bundle. The PL bundle also showed highest stress concentration on the anterior aspect of the bundle. Conclusion: Although the stress patterns were not identical among the AM and PL bundle, there were common trends in the stress distribution. The stress concentration was predominant on the anterior aspect of both bundles in response to the anterior tibial load and rotatory load.

  • PDF

Two to Four Year Follow-Up Results after Anterior Cruciate Ligament Reconstruction Using Transtibial Femoral Tunnel at 10 or 2 O'clock Position (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 후 2~4년 추시 결과)

  • Cho, Sung-Do;Youm, Yoon-Seok;Jeong, Ji-Young;Park, Han-Chang
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: To evaluate the 2 to 4-year follow-up results after arthroscopic anterior cruciate ligament (ACL) reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position. Materials and Methods: Eighty-six ACL reconstructions could be evaluated. Evaluations included 2000 International Knee Documentation Committee (IKDC) subjective knee score, Lachman test, Pivot-shift test, KT-1000 arthrometer measurement, 2000 IKDC knee examination and second-look arthroscopy. Results: Seventy-five patients (87.2%) had over 80 in 2000 IKDC subjective knee score. Eighty-three patients (96.5%) had 1+firm end or negative Lachmann test. Seventy-eight patients (90.7%) had a negative Pivot-shift test. Eighty-three patients (96.5%) had less than 5 mm difference by KT-1000 arthrometer. Eighty patients (93.0%) were normal or nearly normal by 2000 IKDC knee examination. Second-look arthroscopy was done in fifteen cases. Nine cases showed good synovialization, four cases showed partial synovialization, two cases showed poor synovialization and graft failure was noted in one case. Conclusion: ACL reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position resulted in a good outcome in terms of rotatory stability as well as antero-posterior stability.

  • PDF

Arthroscopic Posterior Cruciate Ligament Reconstruction with Preservation of the Remnant Posterior Cruciate Ligament (남아 있는 후방 십자 인대 다발을 보존한 관절경하 후방 십자 인대 재건술)

  • Ahn Jin Hwan;Ha Kwon Ik;Chung Yoon Sung;Yang Il Soon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.97-104
    • /
    • 2000
  • Purpose : The majority of PCL deficient knees have some intact remnant PCL bundles. In these cases, the remnant PCL bundles were removed fur easy passage of graft(especially in bone-patellar tendon-bone graft). The purpose of study is to report the results of PCL reconstruction by posterior transseptal portal technique and by preserving the remnant posterior cruciate ligament bundles. Materials & Methods : From November 1993 to June 1999, 44 arthroscopic posterior cruciate ligament reconstructions have been performed by one surgeon. We studied 37 knees those were followed up over 1 year among them. The mean age($14\~56$ years) was 31.8 years. The average follow-up period was 17.8 months($12\~61$ months). The graft materials were 29 double-loop hamstring autografts, 4 double-loop hamstring allografts and 4 Achilles tendon-bone allograft. Results : There are significant improvement of the preoperative subjective symptoms. The last follow-up shows that the average Lysholm knee score was markedly improved from 59.8 pre-operation to 89.2 post-operation and the average KT 2000 side difference was decreased from 11.1mm pre-operation to 2.3 mm post-operation. Follow-up MRI showed that the graft was healed with remnant posterior cruciate ligament bundles as one ligament. Conclusion : The posterior trans-septal portal makes it possible to locate the exact tibial tunnel. The arthroscopic PCL reconstruction preserving the remnant of original PCL bundles seems to provide the good result.

  • PDF

When do we use the Recycling Autograft in Limb Salvage Surgery? (사지구제술에서 언제 재활용 자가골 이식술이 유용한가?)

  • Kim, Jae-Do;Jang, Jae-Ho;Cho, Yool;Kim, Ji-Youn;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.2
    • /
    • pp.95-105
    • /
    • 2008
  • Purpose: To identify which is the best procedure in recycling autograft according to the resection & reconstruction type and recycling methods, and so when the recycling autograft is used in limb salvage surgery. Materials and Methods: We have treated fifty-eight patients (34 male, 24 female; age range 5 to 74 years, mean age 36.5 years), who had the malignant musculoskeletal tumors, with recycling autograft (47 patients with extracoporeal irradiation, 11 patients with pasteurization) from December 1995 to February 2006. The resection and reconstruction type was 3 cases with fragmentary, 8 intercalary, 23 rAPC (recycling-Autograft-Prosthesis composite), 18 osteoarticular, 5 total joint and 1 soft tissue (achilles tendon). The result was evaluated by the radiologic union at junctional site, the functional score by musculoskeletal tumor society score and complications according to the resection & reconstruction type and recycling methods. Results: The junctional union was obtained at 15.0 months in extracoporeal irradiation and 12.6 months in pasteurization. Also the mean radiologic union was shown at 6.0 months in fragmentary, 12.8 months in intercalary, 10 months in rAPC, 23.3 months in osteoarticular and 15.6 months in total joint. The functional score was 65.5% in fragmentary, 60.8% in intercalary, 62.8% in APC (except pelvis), 66.0% in osteoarticular and 66.6% in total joint. We have experienced 1 infection, 1 prutrusio acetabuli in pasteurization (18.1%) and other 22 complications (3 deep infections, 8 nonunions, 2 fractures, 2 epiphyseal problems, 5 joint instabilities, 2 local recurrence) in extracoporeal irradiation (46.8%). Also we have experienced 3 complications (3 nonunions) in intercalary (37.5%), 9 complications (4 nonunions, 1 deep infection, 1 periprosthetic fracture, 1 epiphyseal problem, 1 local recurrence, 1 protrusio acetabuli) in rAPC (50.0%), 6 complications (2 deep infections, 2 nonunions, 1 epiphyseal problem, 1 pathologic fracture) in osteoarticular (33.3%), 5 complications (5 joint instabilities) in total joint (100%) and 1 complication(1 local recurrence) in soft tissue (100%). Conclusion: In our experience, according to the resection & reconstruction type fragmentary and intercalary may have several advantages such as good radiologic and functional result and low rate of complication. And it seems that rAPC was available in case which have no sufficient residual bone stock. Also the pasteurization may have more advantages than that of the extracorporeal irradiation.

  • PDF

Clinical Results of ACL Reconstruction -Bone-Patellar Tendon-Bone vs Hamstring Tendon Autograft- (자가 골-슬개건-골 및 슬괵건을 이용한 전십자인대 재건술후 결과 비교)

  • Song, Eun Kyoo;Lee, Keun Bae;Seo, Hyoung Yeon;Seol, Jong Yoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.91-96
    • /
    • 1999
  • Purpose : The purpose of this study is to compare the clinical and radiologic results of the anterior cruciate ligament(ACL) reconstruction using bone-patellar tendon-bone unit with doubled semitendinosus and gracilis tendons. Materias and Methods : Clinical results of ACL reconstructions which were performed in 47 patients using doubled semitendinosus and gracilis were compared with those performed in 45 patients using bone-patellar tendon-bone autograft. There were no differences in preoperative parameters(age, sex, instability). Average follow-up period were 17 months and 19 months each. Results : There were no significant differences between two groups in functional results (Lysholm knee score), degree of laxity and range of motion at final follow-up. However, the parapatellar complication, especially anterior knee pain after long distance walking or exercise and quadriceps weakness less occurred in hamstring tendon group than in bone-patellar tendon-bone group. Conclusion : Although there were no significant differences in clinical results of ACL reconstruction using bone-patellar tendon-bone autograft and doubled semitendinosus and gacilis, parapateller complications occurred more in the bone-patellar tendon-bone autograft group than in the doubled semitendinosus and gracilis group. It is thought that the careful selection of patient, achivement of skillful technique and active rehabilitation are important to prevent the parapatellar complications.

  • PDF

Clinical Outcomes of Minimum 12-Month Follow-Up of Anatomical Double Bundle ACL Reconstruction with a Longitudinally Split Tibialis Anterior Allograft (종분할된 전경골 동종건을 이용한 해부학적 전방 십자 인대 이중다발 재건술의 최소 12개월 임상 결과)

  • Seo, Young-Jin;Song, Si Young;Kim, In Sung;Ahn, Jung Tae;Yoo, Yon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.2
    • /
    • pp.99-107
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the clinical results after a anatomical double bundle ACL reconstruction using a longitudinally split tibialis anterior allograft. Materials and Methods: We evaluated 24 patients with a minimum follow-up of 12 months who had undergone anatomical double bundle ACL reconstructions. The grafts utilized in all cases were tibialis anterior allografts which were longitudinally split into two strands. A standard rehabilitation protocol was applied in all patients. The pre- and post-operative data including Lysholm scores, International Knee Documentation Committee (IKDC) scores, Lachman test, pivot shift test and the side-to-side differences of anterior laxity measured by KT-2000 arthrometer were analyzed by use of a statistical method Results: The mean side-to-side instrumented laxity measured by the KT-2000 arthrometer significantly improved to a mean of $1.04{\pm}0.80\;mm$ (P < 0.001). The Lysholm knee scores also improved from $58.34{\pm}15.32$ to $86.25{\pm}6.48$ after surgery (P < 0.001). The patients exhibited improved IKDC scores (A: 15 cases, B; 9 cases) at the final follow-up, compared to preoperative scores (B: 5, C: 10, D: 9). Conclusion: Our data demonstrated that clinical results of anatomical double bundle ACL reconstruction with a split tibialis anterior allograft are encouraging with excellent side-to side laxity, significantly improved Lysholm knee score, IKDC score, Lachman and pivot shift data.

  • PDF

Comparison of Single-Incision, Single-Bundle Posterior Cruciate Ligament Reconstruction Using Allograft Tendon (동종건을 이용한 단일 절개, 단일 다발 후방십자인대 재건술의 비교)

  • Kyung, Hee-Soo;Cheon, Sang-Ho;Park, Kyung-Hyun;Jung, Jae-Wook
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.107-113
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the posterior cruciate ligament (PCL) reconstruction with single bundle, single-incision technique using Achilles tendon and tibialis anterior allograft with ligament remnant preservation. Materials and Methods: Twenty six patients underwent PCL reconstruction was included. There were 21 males and 5 females. Mean age was 32 years. Used graft was a fresh frozen Achilles tendon allograft (group I, 14 cases) and tibialis anterior allograft (group II, 12 cases). Arthroscopic PCL reconstruction was performed using transtibial, single-incision and single bundle technique with remnant preserving as possible. For clinical evaluation, range of motion, posterior drawer test, Lysholm score, Tegner activity scale, International Knee Documentation Committee (IKDC) grade and posterior stress radiograph were used. The mean follow-up period was 21.6 months (12-40 months). Associated injuries were 5 medial collateral ligament injuries, which were treated by conservative method. Results: Range of motion (ROM) was returned to normal range in 24 cases, but ROM deficit under $10^{\circ}$ flexion was 2 cases at final follow-up period. Preoperative posterior drawer test was 17 cases in grade II and 9 cases in grade III. At final follow-up 13 cases returned within normal grade, 7 cases grade I and 6 cases grade II posterior instability. Lysholm mean score was improved from preoperatively 62 to 90 at final follow-up period. Tegner activity mean scale improved from preoperatively 3.5 to 5.6 at final follow-up period. IDKC grade was grade A was 3 cases, grade B 17 cases, grade C 6 cases. In posterior stress radiograph, posterior displacement was improved from mean 12 mm preoperative to 4.5 mm at final follow-up. There were no statistical differences between two groups in clinical evaluations. There were two cases of re-rupture of graft at the bone-tendon junction in group I. Conclusion: We had successful results of PCL reconstruction with single-incision, single bundle technique using Achilles and tibialis anterior allograft without difference between two groups in patients with PCL injury. There were more re-rupture of graft in Achilles tendon group.

  • PDF

The Analysis of Present Status and Its Implications on the Patents of 'Bearing Aids' for the Industry Promotion of Medical Devices Based on IT Engineering - From 316 Patents Registered in Korean Intellectual Property Office - (정보통신 의료기기 산업 육성을 위한 '보청기' 관련 특허의 현황 분석 및 이의 시사점 - 국내에 특허 등록된 316건을 중심으로 -)

  • Shim, Jae-Ruen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.294-302
    • /
    • 2009
  • In this paper, the trend of technology and the business strategy on 'Hearing Aids' are investigated for the industry promotion of medical devices based on IT engineering from the 316 patents of 'Hearing Aids' registered in Korean Intellectual Property Office(KIPO). The classification of technology on 'Hearing Aids' is performed according to the IPC(International Patent Classification) code to and the core technology of 'Hearing Aids' As the results of classification of IPC code, the number of patents with IPC code 'H04R', 'H04B', 'H01M', and 'A61F' are 160, 46, 40, and 19 respectively. We found that the Digital technology and the Medical Transplants technology are come to the front of 'Hearing Aids' and the foreign 'Hearing Aids' companies are filed an application with the Korean Intellectual Property Office(KIPO) before their business.

Combined Reconstruction of Posterior Cruciate Ligament and Posterolateral Corner with a Fresh Frozen Achilles Tendon Allograft (한 개의 신선동결 동종아킬레스건을 이용한 후방십자인대 및 후외방구조의 동시 재건술)

  • Kyung, Hee-Soo;Oh, Chang-Wug;Lee, Hyun-Joo;Ihn, Joo-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • Purpose: The purpose of this study is to report a result of the technique that reconstruct posterior cruciate ligament (PCL) and posterolateral corner (PLC) simultaneously using a fresh-frozen Achilles tendon allograft. Materials and Methods: Forty two patients (45 legs) underwent PCL and PLC reconstruction were included. There were 38 males and 4 females. Mean age was 39 years. Used graft was a fresh frozen Achilles tendon allograft, which was divided by two size, larger one (${\emptyset}$ 10 mm) for PCL reconstruction and smaller one (${\emptyset}$ 8 mm) for PLC reconstruction. Arthroscopic reconstruction of the PCL was performed using transtibial, single incision, and single bundle technique with 10mm fresh frozen Achilles allograft tendon first. After PCL reconstruction, reconstruction procedure for posterolateral instability was performed using modified figure of "8" technique using smaller gtaft. For clinical evaluation, range of motion, posterior drawer test, varus stress test, prone external rotation (dial) test, Lysholm score, Tegner activity scale and posterior stress radiograph were used. Mean follow up period was 25 months. Results: Preoperatively posterior drawer test was 5 cases in grade II and 40 cases in grade III posterior instability. At final follow-up 22 cases returned within normal condition, 18 cases grade I and 5 cases grade II posterior instability. Though all patients showed positive result over 10 degrees in dial and varus stress test preoperatively, but only 9 cases showed positive both test at final follow-up. The range of motion deficit over $10^{\circ}$ flexion was 3 cases. Lysholm score was improved from mean 50 preoperatively to mean 83(p<0.05) and Tegner activity scale improved from mean 2.1 preoperatively to mean 4.6(p<0.05). In posterior stress radiographs, posterior displacement was improve from mean 16mm preoperatively to 4.1mm after treatment(p<0.05). All patients had improved compared to their pre-operative status as measured by physical examination such as posterior drawer test, varus stress test, dial test. Conclusion: We had successful results by combined reconstruction of the PCL & PLC with a fresh frozen Achilles tendon allograft in patients with PCL and posterolateral rotatory instability at a time.

  • PDF

Measurement of the Grafts for the Anterior Cruciate Ligament Reconstruction with Tension Load Technique and Achilles Tendon Autograft using Postoperative Magnetic Resonance Imaging (자가 아킬레스 건과 장력 부하 기법을 이용한 전방십자인대 재건술 후 자기 공명 영상을 이용한 이식건의 평가)

  • Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.

  • PDF