• Title/Summary/Keyword: 건축표면

Search Result 459, Processing Time 0.025 seconds

An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter (차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구)

  • Kim, Jin-Hee;Kim, Young-Tag;Lee, Soo-Yeol;Choi, Won-Ki
    • Land and Housing Review
    • /
    • v.12 no.1
    • /
    • pp.129-137
    • /
    • 2021
  • External shading devices are well known solar control devices that can help reduce the cooling load of commercial buildings. For this study, experiments were conducted to examine the feasibility of shading devices in reducing both the cooling and heating loads. The influence of sky radiant cooling during winter was verified for the external shading device, internal roller blind, and window. Results can be summarized as follows. The temperature difference between the inner and outer surfaces of the window with the external shading device was 11.8℃ compared to 14.6℃ for one without the external shading device. This 2.8℃ difference was due to heat exchange by sky radiation when the surface temperature of the shading device was lower than the ambient outdoor air temperature. The roller blind resulted in a lower temperature of 0.8℃ compared to the average temperature of the window's air cavity. This was due to heat exchange by sky radiation of the roller blind surfaces. Without shading devices, the outside surface temperature of the window is about 3℃ higher. The study also found that when external shading devices were installed on both the southwest and southeast sides, the outside surface temperature of the windows were lower on the southwest side than the southeast side.

Cracking Behavior of Concrete Bridge Deck Due to Differential Drying Shrinkage (교량 바닥판 콘크리트의 부등건조수축 균열특성에 관한 연구)

  • Yang, Joo Kyoung;Lee, Yun;Yang, Eun Ik;Park, Hae Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.329-335
    • /
    • 2009
  • The purpose of this study is to provide the efficient method and guideline of controlling the cracking in bridge deck concrete due to differential drying shrinkage. Drying shrinkage cracking is mainly influenced by the moisture diffusion coefficient that determines moisture diffusion rate inside concrete structures. In addition to the diffusion coefficient, surface coefficient of concrete surface and relative humidity of ambient air simultaneously affect the moisture evaporation from concrete inside to external air outside. Within the framework of cracking shrinkage cracking mechanism, it is necessary to conceive the numerical analysis, which involves these three influencing factors to predict and control the shrinkage cracking of concrete. In this study, moisture diffusion and stress analysis corresponding to drying shrinkage on bridge deck are performed with consideration of diffusion coefficient, surface coefficient, and relative humidity of ambient air. From the numerical results, it is found that cracking behavior due to differential drying shrinkage of bridge deck concrete shows different feature according to three influencing factors and the methodology of controlling of drying shrinkage cracks can be suggested from this study.

A Study on the Effect of Fire Heat on the Durability of Concrete Structures Repaired and Reinforced with Epoxy Resin (화열(火熱)이 에폭시수지로 보수·보강된 콘크리트 구조체의 내구성에 미치는 영향에 관한 연구)

  • Tai Kwan Cho
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.138-145
    • /
    • 2023
  • Purpose: In accordance with the increase in the number of buildings repaired and reinforced following deterioration from when a fire occurs in a previously reinforced building, the impact on the structure after the fire is analyzed to establish standards for repair and reinforcement measures. Method: After curing for 28 days, the process was to measure the compressive strength and induce destruction through a compressor, repair and reinforce it with epoxy, and conduct a re-compressive strength test on some specimens after curing for 3 days to understand the degree of strength restoration. The rest of the repaired and reinforced specimens as well as the unrepaired and unreinforced specimens were then put into an oven and heated according to the temporal and temperate conditions listed below, and then the compressive strength was tested to estimate the impact of fire. Result: After reinforcing the yielded specimen with epoxy, the process was to then put it in an oven and heat it at different temperatures over time. It was found that there was a decrease in the strength of the reinforcement more than that of the actual specimen. Conclusion: Based on this, it was found that a building repaired and reinforced with epoxy resin is actually more dangerous than a general unrepaired building when it is damaged by fire, and thus, that it must be prepared for fire vulnerabilities.

A Study on the Meaning and Role of Columes in Mies's Works (Mies van der Rohe 건축에서 기둥의 역할과 의미에 관한 연구)

  • Lee, Byung-Wook;Kim, Yong-Seung;Park, Yong-Hwan
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.2 s.61
    • /
    • pp.123-130
    • /
    • 2007
  • This paper Is to reconsider his architectural significance by understanding the role and moaning of the columns shown in the works of Mies. The reason of such an approach is to reflect the tendency to overlook the various significances of Mies's works as we interpret his architecture simply as a simplified work by abstraction. The process of simplification often neglects open interpretation so that it offers partial and unified cognition frame and causes remaking of closed meanings. It removes some possibilities of new interpretation for Mies's works. The study suggests that his columns are a medium to show the solid body transferring architectural significance in contrast to the immaterialization of body as transparency of modem architecture. It can be said that all the human cognition is usually made within the material limit of visibility and tangibility.

비래염분 추정기법에 대한 해석적 연구

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.11a
    • /
    • pp.116-118
    • /
    • 2011
  • 해안가에 건설되는 구조물 표면은 해풍에 의해 직접적인 영향을 받는다. 해풍에 섞여 날아오는 염분이 건축물 외부에 흡착하여 시간이 경과함에 따라 내부로 확산 이동하게 되어, 콘크리트 내부의 철근이 부식하게 된다. 따라서, 해안가 구조물의 비래염분에 대한 열화 예측을 보다 정확하게 조사하기 위해서는 실환경하에 작용하는 기상요인, 지형, 구조물의 형태 등 대상지역의 다양한 조건을 정밀하게 반영하여 정해야 할 필요가 있다. 풍향, 풍속, 온도, 습도등의 다양하게 변화하는 기상요인에서 각 요인에 따라 발생되는 비래염분량과의 상관성을 분석하기 위해서는 고정된 실험인자에 따른 지속적인 실험이 필요하다. 따라서 본 연구는 비래염분 포집기 개발 및 인공비래염분 발생장치(이하, 인공장치) 개발과 장치 성능의 정확성 향상을 위한 기초 실험 실시에 목표를 하였고, 또한 개발된 비래염분 포집기를 실 환경에 설치하여 각 실험인자에 따른 실환경에서의 비래염분 포집량을 분석하고자 한다.

  • PDF

Application of Modeling of Electromagnetic Wave Propagation for Thickness Determination Using Finite Difference-Time Domain (유한차분 시간영역법을 이용한 콘크리트 두께측정 전자파 모델링의 적용)

  • 임홍철;남국광
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.341-349
    • /
    • 2002
  • The radar method is becoming one of the major nondestructive testing(NDT) techniques lot concrete structures. Numerical modeling of electromagnetic wane is needed to analyze radar measurement results. Finite difference-time domain(FD-TD) method can be used to simulate electromagnetic wave propagation through concrete specimens. Five concrete specimens with different thickness are modeled in 3-dimension. Radar modeling results compare measurement results to find backface of the concrete specimens and measure thickness of the concrete specimens.

Fire Resistance of High Strength Concrete Canonical Analysis Standard for Optimal Response Condition (고강도 콘크리트 내화성능 보강인자의 최적반응조건 도출을 위한 정준분석 모델 기준)

  • Kim, Young-Hun;Lee, Mun-Hwan;Lee, Sea-Hyun;Yu, Jong-Su;Jeong, Jun-Young;Ryu, Deug-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.227-228
    • /
    • 2009
  • This study proceeded to find the optimum mixing rate of a high strength concrete with 80MPa of the contribution and composite effect on the resistance to fire of the fibers were analyzed and the corresponding results were exploited to derive practical mix proportions. Also proceeded to propriety examination of limit value for optimum operating condition.

  • PDF

Forced Ventilation Method for Preventing Surface Condensation of Magazine of Igloo type in Summer (강제환기를 이용한 하절기 군 저장시설의 표면결로 방지에 관한 연구)

  • Park, Sun-Hyo;Yoon, Sung-Do;Sohn, Jang-Yeul
    • KIEAE Journal
    • /
    • v.10 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • In case of earth-covered storage, the condensation occurs on surface of wall and stores in summer with high humidity because of low temperature of constructional mass. Therefore, the preventive plans should be considered to protect stores from the damage by corrosion in earth-covered storages. This study aims to suggest the methods of forced ventilation by the air, to solve the problems of construction's surface condensation at the Magazine of igloo type which is similar to earth-covered storages. A fan was installed at the air outlet for exhaust gas to conduct forced ventilation. The surface and indoor temperature were measured, and then the influence of those on condensation was analyzed. The results of this research are follows; 1) Forced ventilation by a fan affects the rise in surface temperature of walls and stores. 2) The condensation on surface of walls and stores was reduced after operating a fan.

나노입자와 표면증강라만분광학 (Surface Enhanced Raman Scattering: SIRS)을 활용한 탄소재료, 고분자 자기조립박막 및 생체분자 연구

  • 주상우
    • Polymer Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.228-233
    • /
    • 2004
  • 본 기고부분에서는 레이저 라만 분광법을 이용하여 나노입자에 흡착된 자기조립박막의 구조를 밝히고 응용성을 모색하는 일을 소개하고자 한다 Au 나노입자는 최근 재료과학과 의학 및 생물학에서 그 쓰임의 폭이 넓어지고 있다. 나노입자가 처음 사용된 예들 중에 가장 잘 알려진 것은 고대 로마 시대의 Lycurgus 컵에 기인한다고 한다. 컵 안에 함유된 미량의 은이나 금 나노입자에 의해서 반사했을 때와 투과할 때의 빛깔이 다르게 보이며 이러한 성질은 중세건축물의 스탠드 글라스에 이용되어 왔다. 근대적인 의미에서 Au 콜로이드의 수용액이 작은 미세입자가 분산되어 있다고 생각한 사람은 전기화학의 창시자라 할 수 있는 영국의 Faraday라 할 수 있다.(중략)

  • PDF

Good Design in 2013 (2013년 우수디자인(GD))

  • (사)한국포장협회
    • The monthly packaging world
    • /
    • s.246
    • /
    • pp.44-57
    • /
    • 2013
  • 우수디자인이라 불리는 굿디자인(GOOD DESIGN)은 산업디자인진흥법에 의거하여 상품의 외관, 기능, 재료, 경제성 등을 종합적으로 심사하여 디자인의 우수성이 인정된 상품에 마크를 부여하는 제도로 1985년부터 매년 시행하고 있다. GD마크 선정제란 우수한 디자인 상품을 선정, 장려함으로써 환경친화적 디자인개발을 유도하고 지속 가능한 녹색성장에 기여하고 상품의 디자인개발을 촉진하고 독창적이고 우수한 상품디자인을 개발, 상품의 경쟁력 강화를 통한 수출증대와 국민경제 발전에 기여하는데 목적이 있다. 또한 상품의 디자인 수준향상으로 국민의 다양한 욕구충족 및 국민생활의 질적 수준을 높이고 디자인에 대한 일반인의 인식 및 관심을 고취시킴으로써 산업디자인 발전을 촉진하는데 주력하고 있다. 굿디자인은 제품디자인, 환경디자인, 소재표면처리디자인, 패션디자인, 포장디자인, 커뮤니케이션디자인, 건축디자인, 패션디자인 부문으로 나누어 선정된다. 본 고에서는 2013년도 우수디자인(GD) 가운데 포장디자인 부문을 살펴보도록 한다.

  • PDF