• Title/Summary/Keyword: 건축물 에너지효율등급

Search Result 46, Processing Time 0.021 seconds

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

A Study on the Issues and Trends of Zero Energy Policy (제로에너지 정책·제도 변화에 따른 이슈 및 트랜드 분석 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2020
  • In order to reduce greenhouse gas by 30% compared to BAU in 2020, research and development of zero-energy building construction technology for reducing greenhouse gas emissions in the construction industry is being conducted. With the recent implementation of the policy as mandatory through the establishment and commercialization of the zero energy building base, the government should devise measures to support and expand technology through the identification of the current status of the zero-energy building incentive system and the erasure of the erasure. In order to implement zero-energy buildings, excessive construction costs are presented as a major issue in revitalizing the supply of new and renewable energy to enhance Passive (energy efficiency grade of 1++) and achieve self sufficiency of energy (20% or higher). In this paper, the major problems and solutions for zero-energy building identification were presented in order to activate the dissemination of zero-energy buildings, and the recent policy changes resulting from the mandatory use of zero-energy buildings were analyzed.

The Effect of a Geothermal Heat Pump and Photovoltaics Application on the Building Energy Efficiency and ZEB Certification Rating for a Non-Residential Building (지열 열펌프 및 태양광 발전 적용이 비주거용 건물의 에너지효율등급과 ZEB 인증 등급에 미치는 영향)

  • Geon Ho Moon;Chang Yong Park
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.1
    • /
    • pp.1-13
    • /
    • 2023
  • Many government in the world have conducted building energy performance certification program to reduce building energy consumption. In this study, a reference building and its HVAC system was modeled, and the energy load and consumption were estimated by the ECO2 program. The software is a simple building energy simulation program based on monthly calculated method. The building energy efficiency rating the the reference building was 1+ under baseline condition. The simulation results showed that the insulation performance slightly affected building energy load and consumption, but light density had a significant effect on them. The application of geothermal heat pumps gave improvement of building energy efficiency rating but it could not make it possible to get zero energy building(ZEB) certification. The ZEB 5 certification could be achieved by using photovoltaics, however getting better grade was difficult. The simulation results showed that the ZEB 4 certification, one grade higher than ZEB 5, could be attained by using more than one renewable energy source such as geothermal and solar energy in this study.

A Study on the Building Energy Efficiency Rating Changes by Enhanced Thermal Insulation Performance of Building Envelope Standards in Apartment Houses (공동주택에서 외피단열성능기준 강화에 따른 건축물에너지 효율등급 변화에 관한 연구)

  • Cho, Yeong Uk;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • This study aimed to compare the primary heating energy consumption of regional apartment houses based on the enhanced thermal insulation performance of building envelope standards. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the southern region, the largest regional difference in primary heating energy consumption, is $10.3kWh/(m^2{\cdot}year)$. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the central region is $8.0{\sim}8.5kWh/(m^2{\cdot}year)$ and that of the Jeju region is $0.5kWh/(m^2{\cdot}year)$. These energy consumption differences do not result in building energy efficiency ratings changing. The building energy efficiency ratings have the possibility to be changed.

Study of the Assessment Baseline of Carbon Dioxide Emissions based on the Analysis of Building Energy Efficiency Rating System (건축물 에너지효율등급 인증현황분석을 통한 CO2 배출량 평가 베이스라인 연구)

  • Jung, Ho Gun;Shin, Sung Woo;Lee, Byeongho
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.11-19
    • /
    • 2013
  • The purpose of this study is to establish the assessment baseline of $CO_2$ emissions from building operations in the view of GHG reduction policy in Korea. The assessment baseline of $CO_2$ emissions shall be used in GHG policy and Carbon Credits in building sectors, but the assessment baseline has not been studied enough or established yet. Also, $CO_2$ emissions from building operations will be variable according to the building occupancy. Therefore the baseline will be different and this study aimed at the establishment of the assessment baseline for residential apartments and office buildings firstly. After reviews of BEER and international standards for building $CO_2$ emissions such as ISO and UNEP-SBCI documents, the analysis of BEER certification data has been pursued for 292 residential apartment complexes and 65 office buildings in South Korea during 2004~2012. As analysis results, the assessment baseline was set to 23.03 $kg{\cdot}CO_2/m^2{\cdot}yr$ or 1.95 $t{\cdot}CO_2/unit{\cdot}yr$ for residential apartment complexes, and 95.91 $kg{\cdot}CO_2/m^2{\cdot}yr$ for office buildings according to the BEER certification basis. Additional assessment baselines were calculated according to year basis, region basis, public and private basis, and GHG policy basis. Finally, the established baseline for residential apartment complexes has been applied for the pilot project in M district, Seoul, and showed 24.97% reduction rate according to the BEER certification basis.

A Study on the Performance Increase in Building Energy Technology according to the Korea's Zero Energy Building Policy (한국의 제로에너지건축 정책 추진에 따른 건축물 에너지기술 성능 연구)

  • Shim, Hong-Souk;Lee, Sungjoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.543-553
    • /
    • 2021
  • As a key policy for achieving the goal of reducing GHG in the building sector, Korea has enforced the mandatory certification of zero-energy buildings for new buildings in the public sector from 2020. This study evaluated a policy to achieve Net Zero by identifying the trend of changes in building energy performance according to policy and presenting a methodology to analyze the current performance state of energy technology applied to buildings. The final goal was to help stakeholders apply appropriate energy technologies for new buildings. For this study, data collected on building energy efficiency certification over the last four years have shown a gradual increase in energy performance. In addition, K-means cluster analysis was used to analyze the performance status of energy technologies applied to buildings. The high and low clusters of education and office facilities were used to analyze the comparative group (2016-2020, 2020). As a result, the solar module area in both high and low clusters of education facilities increased by 261.1% and 283.5%. In contrast, the solar module area decreased by both high and low clusters of office facilities. The most passive and active technologies showed an increase in energy performance.

Comparing the actual heating energy with calculated energy by the amended standard building energy rating system for apartment buildings (건축물에너지효율등급 평가프로그램에 의한 공동주택 난방에너지 소요량과 실제 사용량 비교)

  • Lee, A-Ram;Kim, Jeong-Gook;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.103-107
    • /
    • 2015
  • Purpose: Since September 1st, 2013, subjects of the evaluation have been expanded, and the evaluation standard has been detailed to enable Building energy rating system for all buildings. Accordingly, the new evaluation program (ECO2) has been developed, and therefore, apartment applied after September 1st, 2013 were evaluated with the new evaluation program. Therefore, this research suggests the improvement plan to figure out reasons for the evaluation result calculation and to calculate the evaluation results close to the actual energy usage by analyzing and comparing primary energy consumption as a result of the new evaluation program (ECO2) and actual heating energy usage on the same building. Method: When comparing evaluation results of the new evaluation program (ECO2) and actual heating energy usage, the tendency was similar but different. Also when comparing seasonally, the tendency was similar, but the different between actual heating energy usage and primary energy consumption during winter is greater than during spring or fall, and when comparing seasonal electric usage, heating alternatives were used through increased electrical usage during winter compared to during spring or fall. Result: Therefore, when evaluating apartment with the new program (ECO2) in the future, evaluation items relevant to the use of heating alternatives should be added, and the modification factor should be added according to the region. Based on the evaluation results of the research and actual energy usage, the Modification factors of the central part and the southern part were calculated respectively as 0.5 and 0.8.

An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old (20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.539-547
    • /
    • 2019
  • Recently, the international community signed a climate change agreement to prevent global warming. Yet currently, the fossil fuels have been widely used in to supply building energy for cooling and heating. The Green Building certification (G-SEED), an energy efficiency rating for new or existing buildings requires that buildings meet certain conditions. Insulation is used as a building material to reduce the energy supply to buildings and to improve the thermal insulation, and it accounts for more than 90% of the total heat resistance provided by the building surface components that meet the energy-saving design standards of new buildings. In this investigation, a performance evaluation study was conducted through an experimental study by directly extracting the foam polystyrene insulation on-site during the remodeling of a building that was in the range of 22~38 years old. Through tests, it was found that the thermal conductivity of the extrusion method insulation (XPS) was reduced by 48% and the compressive strength of XPS decreased by 36% compared to KS M 3808, which is the initial quality standard. For bead method insulation (EPS) with a thickness of 50mm, the thermal conductivity, the compressive strength, and flexural failure load were similar to the initial quality standard. Therefore, in the calculation of the primary energy requirement per unit area per year, the performance of bead method insulation can be estimated simply by considering the thickness of the insulation, while a correction factor that considers its performance deterioration should be applied when extrusion method insulation is used.

A Study on the Estimation of Additional Cost for the Certification of Zero Energy Apartment Buildings (공동주택 제로에너지빌딩 인증을 위한 적정가산비 산정에 관한 연구)

  • Sa, Yong-gi;Haan, Chan Hoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.5
    • /
    • pp.21-30
    • /
    • 2019
  • Environmental and energy issues such as abnormal climate and depletion of fossil fuel due to global warming have emerged as a critical task to threaten human survival. As a result, interest in the Zero Energy Building is increasing as it is an innovative building that can significantly contribute to building energy reduction and greenhouse gas reduction. In the market, however, the added cost of construction is a major stumbling block to the revitalization of the Zero Energy certification. In this study, general private apartment complexes were selected for research, detailed elements for Zero Energy certification were presented based on the construction criteria for eco-friendly houses from the initial design stage, and the cost efficiency analysis of the components for certification were presented. It has been analyzed that only Grade 3 certification can be implemented in apartments due to technical level and physical limitations. Also, after reviewing the cost trend during the lifecycle cost, all expenses can be recovered within 13 years after completion only in the case of grade 5 of the Zero Energy Building. The additional costs proposed in the present study are reflected appropriately in the review of projects for apartments scheduled for order in the future to contribute to the revitalization of the Zero Energy Building certification.

A Survey about Installation Trend for Exterior in Domestic (국내 외장재 설치동향 조사 및 화재위험성 분석)

  • Min, Se-Hong;Jang, Young-Jin;Sa, Jae-Chun;Lee, Jae-Moon;Yun, Jung-Eun;Kim, Mi-Suk;Kim, Yeon-Hwang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.11-14
    • /
    • 2012
  • 최근 고도성장에 발맞추어 건축물의 에너지 효율등급 인증제를 실시하면서 외단열시스템(EIFS) 외장재 사용이 늘어나고 있으며, 건물의 외관상의 디자인을 중시하게 됨으로써 다양한 소재의 외장재를 적용하고 있다. 그러나 건축물의 내부 또는 외부에서 발생된 화재가 외장재를 통해 건물 전체로 확산되는 이른바 동시다발성 화재가 많이 발생하고 있다. 2010년 부산해운대의 고층건물에서 외장재를 통해 연소 확산된 화재가 발생하면서 건축물의 외장재의 관한 규제가 절실해졌다. 현재 국내 건축법과 소방법에는 내화구조 및 내장재에 관한 기준은 있지만 외장재에 관한 기준은 마련되어 있지 않다. 이에 현재 건축물 외장재의 법제화를 하기 위해서 많은 연구와 실험이 진행 중에 있다. 이런 노력에 앞서 현재 상용되는 외장재의 종류를 살펴보고 국내 건축물에 적용된 외장재에 대해서 알아보는 것이 이번 연구의 목적이다.

  • PDF