• Title/Summary/Keyword: 건축면적

Search Result 517, Processing Time 0.022 seconds

A Study on the Architectural Planning of Spatial Organization Elements & Aerial Composition of Public Health Center within Governments Complexes Town - Focused on case studies in Seoul Metropolis - (복합행정타운 내 보건소의 공간구성요소와 면적구성에 관한 건축계획적 연구 - 서울특별시 사례를 중심으로 -)

  • Byun, Yong-Jin;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.224-233
    • /
    • 2010
  • As urban function has become diversified and complicated, multifunctional complex facilities to satisfy new functional desires are necessary. Since local autonomy started, many facilities previously run and managed by central administrative agencies are now under management of localities, and functionally, the necessity for governments complexes town to satisfy diverse taste of populace such as creating local community becomes imminent. Analyzing characteristics by space composition factor of the public health center, newly built as part of such governments complexes town and understanding required area of each part, this project is to be used as basic material for construction plan of public health center that is equipped with local characters while devising construction of the public health center in the governments complexes town. Research method is to analyze four public health center facilities located in governments complexes town sites built after 2007, among twenty five public health centers in Seoul, by spatial functions. Also, based on statistical documents of usage of public health center facilities, research over spatial compositional factors and area composition has been conducted. As a result, connectivity between local government building located inside the governments complexes town and public health center and that of spatial composition factor by part, area ratio by part and floor type of public health center are comprehended. Connectivity type of public health centers are divided into horizontal and vertical connectivity and it is found that spatial composition of public health center is compartmentalized into low level, mid level and high level, to make access by users easier. Level type is decided as radial, rotational and combined by hallway connecting facilities.

A Case Study on Explosive Demolition of Gunsan Steam Power Station in Republic of Korea (군산화력발전소 발파해체 실용화 시험시공 사례)

  • Min, Hyung-Dong;Song, Young-Suk;Kim, Hyo-Jin;Seo, Young-Soo
    • Explosives and Blasting
    • /
    • v.25 no.2
    • /
    • pp.11-21
    • /
    • 2007
  • The main structure of Gunsan steam power station was demolished by the toppling method using high explosives. Height of a main building is 58m and a total floor area is $292,000m^2$. It is Rahmen(rigid-frame) structure consisted of almost columns and beams and slabs exist only in one part of the building for the electricity generators equipments. To improve the efficiency of blasting work, it is separated into 4 sectors. Blasting floors were 1, 2, 3, & 4 stories from first sector to third sector, while 1, 2, 5, & 7 of fourth sector were blasted because it had not slabs. About 102.675 kg of the MegaMITE were used with 225 electric detonator and 638 non-electric detonators to check detonator connection and confidence of detonation. The blasting noise and vibration were monitored to evaluate the environment effect and the damage of the nearby structures.

A Study on the Escape Measures and Fire Protection System Improvement in Discount Stores (대형할인점의 피난대책 및 소방시설 개선방안에 관한 연구)

  • 홍성우;이영재
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.20-27
    • /
    • 2002
  • This study in focused on proposing the improvement plans for refuge and fire-fighting facilities in large shopping malls that are radically spreading. The main subjects are as follows. - The refuge measure for large shopping malls - Problems of installing the refuge facilities in stores and the solutions - Problems of installing the incendiary facilities in stores and the solutions - Problems of installing the indoor fire plug in stores and the solutions As result of the study, it has turned out that escape stairs which are set up according to the standard of size in the process of design plan, have to be decided for their amount, position, specification, etc, in consideration of the number of residents. It is also required to tighten a standard of installing a sprinkler instead of lightening the fire-fighting section in stores, considering obstacles due to facilities installed and procurement of the escape path. In addition, it needs to lighten a standard of installing the indoor fire plug, which is voluntarily set up at the store section incase of installing a sprinkler to make a practical fire-fighting facility available.

A study on composite precedence indices focusing on Jeju (제주지역 경기선행종합지수에 관한 연구)

  • Kim, Kye Chul;Kim, Myung Joon;Kim, Yeong-Hwa
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.1
    • /
    • pp.243-255
    • /
    • 2016
  • The developed composite index has limits to estimate and predict economic status due to economic pattern change and the response change of explanatory variables. A higher precedence individual indicators should be selected to predict the future accurately. In this study, effectiveness of Jeju Island precedence indicators consists of constituents in the area, the consumer price index, services production index, mining and manufacturing production index. The average temperature of Seogwipo and credit card purchase amount is reviewed as an economic turning point consideration and time lag correlation analysis with real data. In addition, we suggest the proper reference cycle in Jeju composite precedence index and evaluate the configuration in leading indicators for Jeju by comparing national economic indicators. Based on the derived results, the current problems of Jeju Island precedence indicators will be illustrated and the improvement methods to estimate a regional composite index will be suggested.

Experimental Study on Shear Capacity of I-slab System Using Slim Precast Slab Deck (슬림 프리캐스트 슬래브 데크를 사용한 I-슬래브 시스템의 전단 성능에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.126-133
    • /
    • 2017
  • This paper presents the shear capacities of hollow slab with plate and octagonal pillar type hollow sphere. Recently, the interest in precast hollow slab system for buildings is growing up according to the demand for high quality control and the increase in slab thickness. A hollow slab system is widely known as one of the effective slab system which can reduce self-weight of slab. However, hollow slabs are vulnerable to the deterioration in the shear strength due to the decrease of concrete at slab web which resists shear. Especially, in case of precast hollow slabs, it has joint surface between precast concrete slab modules along transverse axis of slab, and shear failure, that is caused by cracks at joints, has to be prevented. Therefore, in this study, shear capacity of the I-slab system is evaluated by 3-points-supported shear test along the longitudinal and transverse axis of slab specimen. Test results showed that I-slab had enough shear strength compared to theoretical shear strength even if it included the joint surfaces.

The Analysis of Current Situation of the Building Precision Safety Inspection and Precision Safety Diagnosis Cost from Practitioners Viewpoint (실무자 관점에서의 건축물 정밀안전점검 및 정밀안전진단 실행대가 현황분석)

  • Lee, Jong-Phil;Lim, Nam-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.37-41
    • /
    • 2018
  • Recently, interest in the safety and maintenance of the structures is growing. However, due to the low-cost order placed by the ordering organization, the safety diagnosis specialized institution becomes insolvent and many problems have arisen due to insufficient inspection and diagnosis. Therefore, in this study, the current status of bid cost was examined through the survey of the practitioners and case analysis. As a result, Precision safety inspection is deemed that it is necessary to increase the efficiency of the criteria cost and to strengthen the rigidity of the criteria cost rather than adjusting the criteria cost. Precision safety diagnosis, the criteria cost for structures with a floor area of less than $10,000m^2$ is lowered to 80 % from the current standard. For structures larger than that, the current criteria cost are applied, but it is deemed necessary to strengthen the rigidity of the criteria cost.

The Study for Fire Prevention of Main Wooden Cultural Properties of Korea (국가지정 목조문화재의 소방대책에 관한 실태조사)

  • Back, Min-Ho;Lee, Ji-Hyang
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2010
  • This study is searched in the on actual condition and analysis about the fire fighting measure of 123 main wooden cultural properties designated by the Cultural Heritage Administration. First, the management of wooden cultural properties and the present condition of fire occurrence are arranged. Second, The field research and the information research of related government agencies are done from August. 2008 to October. 2008 about 123 main wooden cultural properties: Cultural properties designation classification, location classification, building area, number of possession cultural properties, present condition of fire fighting, a fire engine drive direction for fire suppression, number of self-defense fire brigade, fire administrator nomination, and the distance and time from a fire station are arranged in this study. Third, the inside and outside present conditions are classified and analyzed by average index for the fire occurrence risk of 123 main wooden cultural properties. And the basic data is arranged for the fire fighting measure of main wooden cultural properties.

A Study on the Presumption of Construction Cost of Public Apartment by Analyzing Actual Construction Cost (실적공사비 분석을 통한 공공주택 공사비 추정에 관한 연구)

  • Yoon, Woo-Sung;Lee, Hyun-Chul;Lee, Han-Min;Go, Seong-Seok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.2
    • /
    • pp.132-144
    • /
    • 2009
  • In this study, the basic data for calculating the proper construction cost as minimizing the uncertainty at the stage of forecasting construction cost with the basis of the analysis on the actual construction cost within completed domestic public apartment house. In this regard, 23 public apartment houses by each region which were ordered by the Korea National Housing Corporation and completed from 2004 to 2007 were selected as the objects of study. Four works such as common temporary installation, construction work, civil work and machine/equipment work which are the important direct cost items based on the actually inputted and settled construction costs were classified by completion year, region, architectural area, and the distribution type considering inflation rate. The sequent actual construction costs per 3.3m2 were compared and analyzed by each work, the proper construction costs were analogized and the calculating formula were presumed with the basis of average actual construction costs to be analyzed and presented.

A Correlation Analysis between the Airtightness and Sound Insulation Performance on the Opening Spaces of Han-style Windows (한식 창호의 개구 면적에 따른 기밀 및 차음 성능간 상관성 연구)

  • Lee, Ju-Yeob;Jang, Hyeon-Chung;Lee, Tai-Gang;Song, Min-Jeong;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.87-95
    • /
    • 2014
  • The purpose of this study is to evaluate the correlation coefficients between the airtightness and sound insulation performance of Han-style windows in New Han-ok. To achieve these goals, field measurements were accomplished in 18 bedrooms of 16 Han-oks in which actual residents were living, and then lab measurements were proceeded in the reverberation lab for evaluating the sound insulation performance. Followings are results. The results of the correlation analysis between the airtightness(Air change per hour at 50 Pa, ACH50) and sound insulation performance(Sound reduction index, Rw) in bedrooms of actual Han-oks, it was found that there were no significant correlation between two evaluating values. On the other hand, it was analyzed that the correlation coefficients of total 24 structures(double casement windows, single casement window, casement and sliding windows, single sliding window, 6 types per each structure) were located on 0.6757 exponentially and 0.4154 lineary in the lab evaluating conditions. But, The results of evaluating 4 structure classificatorily, it was found that there were high correlation coefficients(0.8665~0.9273 at ACH50, 0.8414~0.9346 at Rw). These results were signified that the correlation coefficients were changed according to the each structure and case by case analysis were necessary at the same time.

A Comparative Study on Domestic and Foreign Standards for Air Supply for the Improvement of a Smoke Control System for High-Rise Buildings (국내 고층건축물의 제연설비 성능 개선을 위한 국내·외 급기량 관련 기준 비교연구)

  • Kim, Hye-Won;Lee, Byeong-Heun;Jin, Seung-Hyeon;Lee, Su-Gak;Kim, Jung-Yup;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.105-111
    • /
    • 2019
  • In South Korea, smoke control systems are designed according to the fire safety standards NFSC501 and NFSC 501A. However, there is a problem in that the design values are incompatible when measuring the performance of the system after the design construction for calculating the leakage crack area described in the standards. Therefore, we compared the standards for smoke control systems from South Korea, Japan, and the United Kingdom. In South Korea, designs are conducted uniformly according to the NFSC 501A Manual, but in Japan and the United Kingdom, designs consider smoke temperature, duct loss, and fire floor air supply. Furthermore, they use larger values than in South Korea.