• Title/Summary/Keyword: 건축마감재료

Search Result 96, Processing Time 0.028 seconds

An Analytic Study on the Image of the long-span Structural Types (대형공간 구조형식별 이미지 분석에 관한 연구)

  • 양재혁
    • Archives of design research
    • /
    • v.15 no.4
    • /
    • pp.263-274
    • /
    • 2002
  • This study aims to analyze the image of long-span structures. For the intention, it analyzes the relationship between images and physical attributions of elements such as materials, stresses, configurations, compositions and shapes of structures. The image of structures can represent following 5 factors; friendly-unfriendly, strong-weak, dynamic-calm, superior-inferior, and regular-irregular. The friendly-unfriendly in the image of structure mostly determines on a finished material and partly with a structural shape. The strong-weak in the image of structure determines on configuration of the structural members. The dynamic-calm in the image of structure determines on the structural shape. Hence the structure has dynamic forms when it seems to be open and sharp, namely when it receives the flow of forces in the structural shape, and it has a (-) gauss curved rate or an diagonal appearance. The superior-inferior in the image of structure determines on composition of structural elements. The structure seems to be superior is contributed not simply to support load but positively to create design as a tectonic element. From now on, this study can provide the useful information on the long-span structure design through the more appropriate analysis of the image.

  • PDF

Effects of the Complexity of 3D Modeling on the Acoustic Simulations and Auralized Sounds (3D 모델의 구체성이 건축음향 시뮬레이션 및 가청화시재에 미치는 영향)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.22-32
    • /
    • 2011
  • The present study examined the effects of the complexity of the 3D models on the results of acoustic simulation which is the predominant tool of the acoustical design of buildings. Also, the effects of the 3D model on the auralized sounds were investigated. In order to carry out the study, four 3D models with different levels of complexity were introduced for a real auditorium which have different numbers of surfaces in the persuit of the guidance of odeon room acoustic software. The set-up of models was also based on the level of transition order of the program. And the acoustic experiments were performed measuring room acoustic parameters including SPL, RT, C80, D50. Acoustic computer simulations were performed using four different models. Then, the results of the computer modeling were compared with the measured acoustical parameters. In addition, sound sources were recorded in the field and auralized sounds were made in convolution with the impulse source made from acoustic modeling. Then, subjective tests were undertaken using auralized sounds. As the results, it was found that the result of the acoustic simulation were closer to the real room acoustic properties when 3D model was more particularly made. For the subjective test, the listening materials were acknowledged as similar with the real sound source when more complex 3D model was used. Then, it could be concluded that the complexity of the 3D model affects the results of the acoustic modeling as well as subjective tests.

Analysis of Hygrothermal Performance for Standard Wood-frame Structures in Korea (국내 농어촌 표준 목조주택의 hygrothermal 성능 분석)

  • Chang, Seong Jin;Kang, Yujin;Wi, Seunghwan;Jeong, Su-Gwang;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.440-448
    • /
    • 2016
  • As recent buildings become more air tight, the natural ventilation rate is significantly reduced and it leads to difficulty in removing accumulated moisture in buildings. Hot and humid weather in summer and the large amount of moisture caused by indoor activity are the major factors of moisture problem in Korea. The hygrothermal behavior of building environment has to be considered carefully to reduce condensation risk and mold growth potential, and comfortable indoor environment. In this study, we evaluated hygrothermal behavior of Standard Wood-frame Structure published in the Korea Rural Community Corporation Using WUFI simulation program. The results indicated that the total water contents of wood wall measured in 2014 was lower than wood wall in 2010. As a result of evaluation by separating the farming and fishing areas, Moisture problems in fishing area became larger. The walls had a significant impact on the relative humidity than the temperature each areas. Furthermore, excessive water content problem of the wood-based material was reduced in the wall that could be applied in the fishing villages by changing the outdoor finishing materials. And Mold growth risk on the interior materials could be removed through the different setting of the indoor temperature during summertime.

Effect of the Inter-aural Level Differences on the Speech Intelligibility Depending on the Room Absorption in Classrooms (실내 흡음에 따른 양이간 음량차가 강의실의 음성명료도에 미치는 영향)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.335-345
    • /
    • 2013
  • The present study investigates the effect of the inter-aural level difference(ILD) on the syllable articulation test in classrooms which can be occurred by the absorption of interior surfaces. In order to do this, the sound absorbing materials were installed in the classroom and sound pressure level(SPL) at each ear was measured using binaural recording systems. Also, syllable articulation tests were carried out at a classroom with and without sound absorption materials by 20 students who have normal hearing condition, in order to investigates the effect of the ILD on the speech intelligibility. As a result, it was found that the larger inter-aural level differences was occurred at the nearer positions to lateral walls after sound absorptions were applied to lateral walls in the classroom. At some places, the measured ILD was lager than JND of sound level (3dB). Also, it was shown that the correlation coefficient of inter-aural level difference with the score of syllable test has the significant result(-0.441). Thus, It is concluded that ILD can affect the subjective speech intelligibility in classrooms.

Quality Management Platform of Ocher Concrete Using Nondestructive Tests Based on the Stress Waves (응력파기반 비파괴검사법을 이용한 황토콘크리트 품질관리 플랫폼)

  • Hong, Seong-Uk;Kim, Seung-Hun;Kim, Seong-Yeob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.120-127
    • /
    • 2016
  • Several problems including respiratory and skin disorders due to the problems for sick house syndrome have occurred, there appears echo friendly materials to solve the problems. The research is lacking in quality management techniques ocher concrete using nondestructive tests. In this research, the experimental works were conducted to study the initial quality control for the compressive strength of Ocher concrete(21 MPa). The purpose of this study is the implementation platform for quality management of ocher concrete using nondestructive tests. It uses the relationship between the compressive strength and ultrasonic pulse velocity of the ocher concrete to estimate the compressive strength of the ocher concrete. And using the impact echo method to estimate the thickness of the ocher concrete. The platform is based on a Java script, so that the user can obtain the data through the platform.

A Study on Evaluating the Fire Safety of the Regulation of Escape and Fire-Prevention from Enacting to Now - Focusing on the Hotel Building - (우리나라 피난방화규정의 제.개정시기별 화재안전성능 평가 - 호텔건물을 중심으로 -)

  • Lee, Se-Myong;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.28-41
    • /
    • 2011
  • Regulation of Escape and fire-prevention of Building of South Korea were enacted as a part of building codes in 1962. Since it was enacted, the law has gone through many changes. In this study, evaluated the fire safety of the law about the case of a hotel that the fire risk are expected to be higher whenever it was changed. As a result, the current law has gotten better in tire safety since it was enacted. However, especially it could be confirmed that the evacuation safety is insufficient in the lower level of hotel building. In the case of accommodation, because the occupants become aware of fire lately, they have not enough time to escape. Therefore, this study suggests that it is needed to come up with an effective counterplan about the interior finish materials, fire door and fire compartments that the smoke layer descending time is longer.

A Study on Toxicity Bio-markers of a Mouse using Combustion Gas SO2 generated from Fire (마우스(mouse)를 이용한 건축물 마감재료 연소가스 SO2의 독성생체지표 연구)

  • Rie, Dong-Ho;Cho, Nam-Wook;Choi, Soon-Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.43-51
    • /
    • 2012
  • This study was carried out to observe the impacts of a mouse's inhalation of toxic gas SO2 generated from combustion on its organs by different concentrations. As for research methods: First, after concentrations of SO2 generation from combustion had been set to three: low (10.4 ppm), middle (24.9 ppm) and high (122 ppm) through Gas Toxicity Testing Method (KS F 2271) and SO2 combustion gas was exposed to eight mice in each concentration. Five mice that were able to move based on LD50, a criterion, which sets the down time of a mouse's average behaviors to over 9 minutes, were randomly selected in each concentration, and they were set up as the subjects of the study on toxicity bio-markers. Second, tissues were taken from heart, liver, lungs, spleen and the thymus gland of the mice selected in each concentration and a pathological examination of them was carried out. As a result, microvascular congestion appeared in the heart, and cell necrosis, cortex congestion and tubule medulla congestion, etc. in each concentration were observed in addition to vascular congestion in liver, lungs, spleen and the thymus gland. Also, it was found that the higher the concentrations of SO2 exposure is, the greater, the changes in the organs get. Through this study, SO2 of various toxic gases generated from fire turned out to affect the tissues of each organ of a mouse, it is expected that the toxic gases may greatly affect human body in case of actual fire, and this study is evaluated as having a significance as a basic data on inhalation toxicity assessment of toxic substances generated in combustion.

Analysis of Radon Reduction Effect Using Coffee Waste Mixture (커피 찌꺼기 혼합물을 활용한 라돈 저감 효과 분석)

  • Je, Jae-Yong;Kim, Gyeong-Min;Kim, Yul-Min;Lee, Hyun-Woo;Park, Ji-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.855-860
    • /
    • 2021
  • Coffee is a popular beverage not only in Korea but also around the world, and its consumption is on the rise. As coffee consumption increases, coffee waste are also increasing, and recycling is attempted in various fields. However, these recycling methods require complex recycling processes and specialized skills. However, in this study coffee waste, agar powder, and powdered glue were mixed in an appropriate ratio and used as a cement building finishing material. This recycling method has a simple manufacturing method and was shown to improve indoor air quality by delaying radon emitted from cement walls for 2.5 hours with one application and 3.9 hours with two applications. In addition, it was shown that after applying the coffee waste mixture, it was applied twice to close the cracks that occurred during the drying process, thereby prevent the coffee waste from falling off the wall for aesthetic perfection.

Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus (EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가)

  • Seo, Jungki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.655-663
    • /
    • 2016
  • Increasing green house gas and it consequent climate change problems are discussed as a global issue. Accordingly, future local green house gas emission will increase up to 40% of the entire local green house gas emission and therefore, efforts to reduce the emission in construction industry is urgently required. Therefore, in this study, heating energy demand was analyzed by using the EnergyPlus simulation according to wood material finishes configuration. EnergyPlus has the entry for a variety of buildings and heating, ventilation, air conditioning (HAVC) system components, in particular buildings, air conditioning systems, and performs simultaneous integrated calculated through the feedback between the heat source unit, a verification program according to the ASHRAE Standard 140-2007 to be. The climate data for the simulation we used the data IWEC in Incheon and Gwangju provided by EnergyPlus. The analysis of simulation model was farm and fishing house standard design drawings: 2012, presented at the Korea Rural Community Corporation. The results of simulation of central region and southern region were effected by wood products of simulation model into the interior finish, exterior finish, windows, wooden structure. Also, it was confirmed that the reduced heating energy demand.

Behavior of C-Shaped Beam to Square Hollow Section Column Connection in Modular Frame (모듈러 골조의 각형강관 기둥과 C형강 보 접합부의 거동 평가)

  • Lee, Sang Sup;Park, Keum Sung;Hong, Sung Yub;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.471-481
    • /
    • 2015
  • Modular building is a prefabricated construction system for building where factory-produced pre-engineered modular units are delivered to site and assembled as substantial elements of a building. There are two basic kinds of modular structures. One is a load-bearing wall structure designed to transfer the load through longitudinal walls. The other is a frame structure composed of columns and beams. For frame structure, square hollow section is often used as a column member and channel as a beam member in modular unit. Lower and upper modules are fasten with bolts via a pre-installed access hole in the SHS column. However, the access holes can weaken the panel zone that would affect the behavior of beam to column connection. The 5 specimens of beam to column connections with parameters of access hole, column thickness and diaphragm were made and this paper describes the test results.