• Title/Summary/Keyword: 건축구조기준

Search Result 523, Processing Time 0.027 seconds

Self-Optimizing Structural Design of a Pre-engineered Building System with Nonprismatic Members based on AISC2005 (AISC2005에 기준한 변단면 선설계 건축물시스템의 자동화 최적구조설계)

  • Kim, Yong Seok;Oh, Myoung Ho;Song, Byung Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.2
    • /
    • pp.193-201
    • /
    • 2009
  • Structural design of most nonprismatic Pre-Engineered Building Systems (PEBS) is performed using optimizing software developed in foreign countries. In this study, a structural optimizing software for the design of 3-D structures of nonprismatic PEBS is developed according to the allowable stress design method of AISC2005 and KBC. Optimizing structural design with nonprismatic members is carried out by repeating the process of structural analysis and member design to minimize the weight of a structure. According to the optimizing design results of 2-D and 3-D structures with nonprismatic members, there are considerable steel savings in designing structures with nonprismatic H-shaped built-up sections rather than with H-shaped rolled sections. When H-shaped built-up sections were used, the weight of the structural steel was reduced when AISC2005 specification rather than AISC1898 was used in the design. It is therefore concluded that utilizing the new AISC2005 specification is safer in preventingweb buckling because the height of a member is designed to be small despite some differences depending on the structural type.

A Study on the Vibration Characteristics of Sungnyemun (숭례문의 진동특성에 관한 연구)

  • Kim, Hye-Won;Lee, Jung-Han;Park, Min-Kyu;Park, Byung-Cheol;Yi, Waon-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.540-543
    • /
    • 2009
  • 본 연구는 숭례문의 진동측정을 통한 고유진동수와 감쇠, 진동모드 등의 파악을 목적으로 한다. 목조 건축물의 진동측정방법은 건축물에 손상을 주지 않으며 공학적인 데이터의 획득으로 숭례문의 시간, 환경에 따른 구조특성의 변화를 수치적으로 파악할 수 있게 해준다. 숭례문에 대하여 상시미동측정과 인력가진측정을 실시하였다. 그 결과, 숭례문의 진동특성은 장변방향으로 2.12Hz, 단변방향으로 1.56Hz로 비슷한 규모와 형식이라고 할 수 있는 흥인지문, 수원 팔달문보다 높은 고유진동수값을 얻었고 감쇠값은 장변방향으로 1.7%, 단변방향으로 1.8%의 값을 가진다. 2008년 화재로 전소된 숭례문의 진동특성이지만 앞으로 비슷한 구조 건축물에 대한 측정 데이터의 축적을 통하여 목조 건축물의 진동특성에 대한 주기식 및 성능파악에 대한 기준 및 평가자료의 근거로 쓸 수가 있다.

  • PDF

Evaluation on the Fire Resistance Performance for High-Rise Modular Walls (중·고층형 모듈러 벽체의 내화성능 평가)

  • Yang, Seung-Cho;Lee, Jae-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.15-22
    • /
    • 2019
  • The use of modular buildings is increasing because of various advantages of modular buildings. But there are limits to apply modular buildings to medium-rise buildings because the building law provides only the specification criteria of the modular building with respect to the 1 hour fire resistance performance. This study was conducted to investigate 2 hours fire resistance performance of load bearing walls with steel studs in modular buildings by KS F 2257-1 and KS F 2257-4. After full scale tests, load bearing walls ensuring two hours fire resistance performance consist of at least 2 layers of fire resistance plaster boards of 19mm thickness or 3 layer of fire resistance plaster boards of thickness.

Analysis of Characteristics of Seismic Source and Response Spectrum of Ground Motions from Recent Earthquake near the Backryoung Island (최근 백령도해역 발생지진의 지진원 및 응답스펙트럼 특성 분석)

  • Kim, Jun-Kyoung
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.274-281
    • /
    • 2011
  • We analysed ground motions form Mw 4.3 earthquake around Backryoung Island for the seismic source focal mechanism and horizontal response spectrum. Focal mechanism of the Backryoung Islands area was compared to existing principal stress orientation of the Korean Peninsula and horizontal response spectrum was also compared to those of the US NRC Regulatory Guide (1.60) and the Korean National Building Code. The ground motions of 3 stations, including vertical, radial, and tangential components for each station, were used for grid search method of moment tensor seismic source. The principal stress orientation from this study, ENE-WSW, is consistent fairly well with that of the Korean Peninsula. The horizontal response spectrum using 30 observed ground motions analysed and then were compared to both the seismic design response spectra (Reg Guide 1.60), applied to the domestic nuclear power plants, and the Korean Standard Design Response Spectrum for general structures and buildings (1997). Response spectrum of 30 horizontal ground motions were used for normalization with respect to the peak acceleration value of each ground motion. The results showed that the horizontal response spectrum revealed higher values for frequency bands above 3 Hz than Reg. Guide (1.60). The results were also compared to the Korean Standard Response Spectrum for the 3 different soil types and showed that the vertical response spectra revealed higher values for the frequency bands below 0.8 second than the Korean Standard Response Spectrum (SD soil condition). However, through the qualitative improvements and quantitative enhancement of the observed ground motions, the conservation of horizontal seismic design response spectrum should be considered more significantly for the higher frequency bands.

Performance Criteria and Improving Method of Firestop Systems in Fire Compartmentation - Focused on Through-Penetration Sealing System - (방화구획 내화충전구조의 성능기준 현황 및 개선방안 - 설비관통부 충전시스템을 중심으로 -)

  • Yeo, In-Hwan;Yoon, Myung-O
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.354-359
    • /
    • 2010
  • 최근 성능기준에 의한 평가규정이 시행된 건축물 내화충전구조에 대해 관련 제도운영체계와 국내외 성능평가방법 및 성능기준을 살펴본 후 현재 기준의 보완점과 향후 개선방안에 대해 고찰하였다. 내화충전구조는 방화구획의 기능을 완성시키는 중요한 부분으로서 연구개발 및 시장활성화가 필요하며, 현장 품질을 확보 유지할 수 있는 관리체계가 필요하다. 한편 내화성능 뿐만 아니라 구조거동에 대한 대응 및 내구성에 대한 기술기준의 보완 마련이 필요하다.

  • PDF

Understanding The MEP Design Level Through BIM (BIM을 통한 건축기계설비 설계 수준의 이해)

  • Hong, Seng-Soo;Hong, Won-Hyuk;Lee, Hyuk-Jin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.247-251
    • /
    • 2011
  • 국내에도 BIM이 도입되어 다수의 프로젝트가 수행되고 있으며 정부에서는 정책적으로 BIM 확산을 도모하고 있다. 하지만 기술적 한계와 이해의 부족으로 인한 여러 가지 부작용이 발생하고 있으며 특히 현재 도입이 가장 활성화 되어 있는 설계 엔지니어링 업무 영역에서 보완이 필요한 부분도 가장 많이 발생하고 있는 실정이다. 이에 본 연구에서는 기존의 설계사례의 분석을 통해 협업 관점에서 MEP 작업요소의 주요 이슈를 도출하고 건축기계설비의 관점을 좀 더 정확하게 이해할 수 있도록 타 공종 기준의 MEP 작업요소 이해를 위한 기준을 제시하였으며 이러한 내용이 앞으로의 국내의 BIM 프로젝트의 수행과 지침의 작성에 활용될 수 있는 기초자료로 활용되기를 기대한다.

  • PDF

A Study on the Appropriate Response Modification Factor(R) for the Complex Building Based on the Number of Stories of Lower Frame-Upper Wall (하부골조의 층수에 따른 주상복합건물의 정정 반응수정계수에 관한 연구)

  • 최문성;김희철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.13-24
    • /
    • 2000
  • 최근 국내에서 많이 건설되어지고 있는 주상복합 건축물은 하부의 골조형식과 상부의 벽식 구조가 결합된 구조형식을 가지고 있다 따라서 지진 발생시 동일한 형식을 가진 건축물과는 상이하고 복잡한 반응을 보이게 된다 이러한 건축물의 등가정적 해석시 국내 규준에서는 기타구조물로 분류하여 3.5 의 반응수정계수를 적용하고 있다 그러나 이 계수는 검증되어지지 않는 상태로 사용되어지고 있으므로 상당한 위험성을 내포하고 있다 본 연구에서는 단순화한 주상복합 건물의 해석 및 실제의 건물에 대한 3차원 비선형 해석을 통하여 반응수정계수를 유도하였다 유도된 반응수정계수는 ATC 기준과 우리나라 기준의 차이를 고려한 보정을 수행하였다.

  • PDF