• Title/Summary/Keyword: 건설사업 관리

Search Result 1,844, Processing Time 0.029 seconds

Reduced Loads Characteristics Comparison Between Permeable Pavement and Non-point Pollutants Treatment Facility (투수성 포장재와 비점오염저감시설의 삭감부하량 특징 비교)

  • Gil, Kyung-Ik;Jeon, Hye-Sun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.193-198
    • /
    • 2011
  • This study aimed to provide basic data for permeable pavement application upon design and installation stages by analyzing the effect of permeable pavement used on the facility area rather than using non-point pollutants treatment facility upon development business in accordance with recent trend. To perform this study, the area of development target was separately applied as impermeable and permeable developments so as to compare and analyze the economics of cut pollution load and installation construction cost. Consequently, the processing amount and cut load of non-point pollutant sources are influenced much by permeable and impermeable developments, and it was turned out to be better to develop target river area as permeable area rather than installing non-point pollutants treatment facility of equipment type or natural type upon development to yield smaller discharge load. If we can prepare a countermeasure regulating impermeable area ratio to certain level to manage non-point pollutants upon development based on this result, we can minimize the source of pollution caused by the development.

A Study on the Guidelines for Creating Wildlife Crossing through Environmental Impact Assessment (환경영향평가 협의 시 생태통로 조성을 위한 가이드라인 마련)

  • Park, Yong-Su;Shim, Yun-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.287-298
    • /
    • 2019
  • This study found that wildlife crossing created through environmental impact assessments didn't reduce the number of wildlife accidents on the road by review of "A Study on the Legal and Institutional Review for Reproving Bio-Mobile in Environmental Impact Assessment(2018)". Specific considerations to be reviewed at each stage of the environmental impact assessment consultation were presented for practical site application. Therefore, in this study, the consultation steps for environmental impact assessment were presented in five stages, including planning, design, construction, monitoring, maintenance and management, and detail of the items to be reviewed by public officer. It will be able to prevent loss of habitats and improve biodiversity by improving the practice and institutional problems that were planned and designed at the time of construction.

A review on status of organic micropollutants from sewage effluent and their management strategies (하수 유래 미량오염물질 현황과 관리 방안 고찰)

  • Choi, Sangki;Lee, Woongbae;Kim, Young-Mo;Hong, Seok-Won;Son, Heejong;Lee, Yunho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.205-225
    • /
    • 2021
  • Due to the large-scale production and use of synthetic chemicals in industralized countries, various chemicals are found in the aquatic environment, which are often termed as micropollutants. Effluents of municipal wastewater treatment plants (WWTPs) have been identified as one of the major sources of these micropollutants. In this article, the current status of occurrence and removal of micropollutants in WWTPs and their management policies and options in domestic and foregin countries were critically reviewed. A large number of pharmaceuticals, personal care products, and industrial chemicals are found in WWTPs' influent, and are only partially removed by current biological wastewater treatment processes. As a result, some micropollutants are present in WWTPs' effluents, which can negatively affect receiving water quality or drinking water source. To better understand and assess the potential risk of micropollutants, a systematic monitoring framework including advanced analytical tools such as high resolution mass spectrometry and bioanalytical methods is needed. Some Western European countries are taking proactive approach to controlling the micropollutants by upgrading WWTP with enahnced effluent treatment processes. While this enahnced WWTP effluent treatment appears to be a viable option for controlling micropollutant, its implementation requires careful consideration of the technical, economical, political, and cultural issues of all stakeholders.

Case Studies of Indirect Coupled Behavior of Rock for Deep Geological Disposal of Spent Nuclear Fuel (사용후핵연료 심층처분을 위한 암석의 간접복합거동 연구사례)

  • Hoyoung, Jeong;Juhyi, Yim;Ki-Bok, Min;Sangki, Kwon;Seungbeom, Choi;Young Jin, Shin
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.411-434
    • /
    • 2022
  • In deep geological disposal concept for spent nuclear fuel, it is well-known that rock mass at near-field experiences the thermal-hydraulic-mechanical (THM) coupled behavior. The mechanical properties of rock changes during the coupled process, and it is important to consider the changes into the analysis of numerical simulation and in-situ tests for long-term stability evaluation of nuclear waste disposal repository. This report collected the previous studies on indirect coupled behaviors of rock. The effects of water saturation and temperature on some mechanical properties of rock was considered, while the change in hydraulic conductivity of rock due to stress was included in the indirect coupled behavior.

BIM-based Efficiency Review of Barrier Free Certification Items (장애물 없는 생활환경(BF)인증 항목의 BIM기반 효율성 검토)

  • Kang, Kyung-Ha;Son, Byeung-Hun;So, Seung-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.2
    • /
    • pp.183-194
    • /
    • 2022
  • This study conducted a survey for BIM experts as a basic study to improve the efficiency of a BIM-based review of the BF certification evaluation method. By limiting the buildings to elementary schools, the first survey was conducted to extract the mandatory facilities from the BF certification evaluation items according to the evaluation criteria, and 63 out of a total of 94 evaluation items were extracted. The extracted facilities were intermediary facilities, internal facilities, and sanitary facilities. The second survey provided detailed calculation criteria for BF certification evaluation items, and through investigating the possibility of BIM-based review, 31 items were derived. In the 3rd and final survey, when asked about the effectiveness of the current CAD-based and BIM-based evaluation methods, the BIM-based evaluation method showed 96.8% effectiveness and the CAD-based evaluation method showed 3.2% effectiveness.

Enhanced sewage effluent treatment with oxidation and adsorption technologies for micropollutant control: current status and implications (미량오염물질 관리를 위한 산화 및 흡착 기반 하수 방류수 강화처리 기술의 연구 동향 및 시사점)

  • Choi, Sangki;Lee, Woongbae;Kim, Young Mo;Hong, Seok Won;Son, Heejong;Lee, Yunho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.2
    • /
    • pp.59-79
    • /
    • 2022
  • Conventional wastewater treatment plants (WWTPs) do not fully remove micropollutants. Enhanced treatment of sewage effluents is being considered or implemented in some countries to minimize the discharge of problematic micropollutants from WWTPs. Representative enhanced sewage treatment technologies for micropollutant removal were reviewed, including their current status of research and development. Advanced oxidation processes (AOPs) such as ozonation and UV/H2O2 and adsorption processes using powdered (PAC) and granular activated carbon (GAC) were mainly discussed with focusing on process principles for the micropollutant removal, effect of process operation and water matrix factors, and technical and economic feasibility. Pilot- and full-scale studies have shown that ozonation, PAC, and GAC can achieve significant elimination of various micropollutants at economically feasible costs(0.16-0.29 €/m3). Considering the current status of domestic WWTPs, ozonation and PAC were found to be the most feasible options for the enhanced sewage effluent treatment. Although ozonation and PAC are all mature technologies, a range of technical aspects should be considered for their successful application, such as energy consumption, CO2 emission, byproduct or waste generation, and ease of system construction/operation/maintenance. More feasibility studies considering domestic wastewater characteristics and WWTP conditions are required to apply ozonation or PAC/GAC adsorption process to enhance sewage effluent treatment in Korea.

A Study on Slope Reinforcing Effects Using Soil Stabilizer (토사안정제를 이용한 비탈면보강 효과에 관한 연구)

  • Kim, Ki-Hwan;Kim, Yu-Tae;Lee, Seung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.10
    • /
    • pp.5-14
    • /
    • 2010
  • The slope stability method using the soil stabilizer is a way to ensure that the slope stability from reinforcing method is environmentally friendly. However, the reinforcing method does not ensure slope stability for lack of research on the reinforcement effect of the mixture with soil. So the application of this method implies difficult technical issues. In this research, reinforcement effect is investigated according to the different ratio of mixture. And the optimum reinforcement depth is proposed according to the height of slope from numerical analysis. The results show that approximately the soil strength increases from two to three times. From numerical analysis, it is possible to estimate the optimum height according to the height of slope. It is anticipated that the use of soil stabilizer will increase the slope stability.

Analysis of Electrical Resistivity Change in Piping Simulation of a Fill Dam (필댐의 파이핑 재현시험시 전기비저항 변화 분석)

  • Ahn, Hee-Bok;Lim, Heui-Dae
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.4
    • /
    • pp.59-68
    • /
    • 2010
  • Piping, a common form of internal embankment erosion, is caused by progressive movement of soil particles through an embankment. The phenomenon commonly occurs with precursory signs of development of fractures in dam structures, but also occurs without any noticeable signs in dams that showed satisfactory dam performance for several years, due to dissolution of soluble material in an embankment. While piping accounts for nearly 50% of the causes for dam failure, few studies have been made for systematic evaluation of the phenomenon. In this study, we attempted to monitor the changes in electrical resistivities of fill-dam material while a saddle dam is dismantled for the construction of emergency spillways of Daechung dam. Two artificial subhorizontal boreholes were drilled into the embankment structure to simulate piping along the two artificial flow channels. Monitoring of changes in electrical resistivity showed an increase in resistivity values during piping. Thus, the investigation of resistivity over time could be an effective method for piping prediction.

A study on the indirect measurement method of bedload discharge using hydrophone (하이드로폰을 이용한 소류사량 간접계측방안 분석 연구)

  • Kim, Sung Uk;Jun, Kye Won;Yoon, Young Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.249-249
    • /
    • 2022
  • 국외에서 산지재해를 예방하기 위해 하천 유사량을 계측하는 기존의 재래식 채집기의 문제점을 보완한 간접계측장치인 하이드로폰의 개발 및 실용화를 위한 연구를 수행하고 있다. 하지만 국내의 경우 유사량을 계측하는 기술 수준은 선진국에 비해 기초단계에 머물러 있다. 이러한 문제를 해결하기 위해 국내에서 사용하기 적합한 간접계측장치를 개발하고자 한다. 간접계측장치인 하이드로폰은 횡단구조물의 끝단에 부착하여 설치하는 형태로 개발하였다. 충돌음향 계측을 위한 센서부는 파이프와 마이크로폰으로 구성하였으며, 구조물에 부착하기 위한 고정프레임과 연결장치로 제작되었다. 설치된 계측장치는 하상에서 이동중인 토사가 파이프에 충돌할 때 발생하는 소음을 계측하며 충돌음은 데이터로거로 취득된다. 계측된 음향 데이터는 정확한 소류사량 추정을 위해 충돌 횟수에 착안한 펄스 분석 방법과 진폭의 시간 적분치에 착안한 음압적분치 방법으로 비교·검토를 수행하였다. 소류사량 추정 관계식의 유의성 분석을 수행한 후 펄스 수 기반 추정 관계식과 음압적분치 기반 추정 관계식을 공급 소류사량과 비교시 각각 29%와 33%의 오차율을 나타내는 것을 확인할 수 있었다. 앞서 선정된 소류사량 추정 관계식의 신뢰성을 확보하기 위해 관계식으로 추정할 수 있는 예측구간 및 95% 신뢰구간을 분석하였으며, 분석 결과 펄스 수 기반 추정 관계식은 92.5%, 음압적분치 기반 추정 관계식은 90.9%로 두 관계식 모두 소류사량을 추정하기에 양호한 수준으로 일치하는 것을 확인할 수 있었다. 향후 추가적인 연구를 수행한다면 수문조사 시 부족했던 유사량 측정분야의 확대에 기여할 수 있을 것으로 예상되며, 이와 관련된 사업 및 기술발전에도 기여할 것으로 기대된다.

  • PDF

The deployment Advanced Technology of Water supply line breakage detection system in Songsan Green City (송산그린시티(동측)내 선진 상수관로파손감시시스템 구축기술)

  • Kwag, Jun keun;Park, Ji Young;Yoon, Sang Jo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.291-295
    • /
    • 2022
  • This paper deal with the advanced thchnology of water supply line breakege detection system in singsan green city. the technology apply for construction eco oriented high-tech city to merge residant, industial, tour reasure parts for songsan green city furture direction achivement and response for a life style change of people in the city. Breakege detection system consist of smart prevention seat, pipeline breakege detection sensor, analysis software, server. etc.. Central control unit sent the data to hwa sung city water supply office by WCDMA in SKY. the data are states about water supply pipeline, Location.etc. This system maintain the long term life cycle of water supply plpeline by the prevention the leakege event through ackonwledge information of evnet occurrence locaion. and used to realtime sense method about demage information of the pipeline and prevent to brekege facilities during excavation work.

  • PDF