• Title/Summary/Keyword: 건물화재

Search Result 708, Processing Time 0.02 seconds

Experimental validations of fire-resistant materials for protecting LPG small storage tank from building fires (건물 화재 시 LPG소형저장탱크 보호용 화재 저항 재료 성능 실증)

  • Kim, Seung-Hwan;Kim, Kyung-Sik;Heo, Seung-Geon;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.18-24
    • /
    • 2020
  • The purpose of this study is to validate thermal hinderance effects, i.e., feasibilities, of fire-proof structure for LPG tank exposed to fire from adjacent burning building. The panel materials suggested for the fire-proof structure are (1) 10 mm-thick wood, (2) wood with fireproof coating, (3) 75 mm-thick Expanded Polystyrene, (4) 75 mm-thick glass wool filled sandwich panel, and (5) 75 mm-thick autoclaved lightweight concrete. The square planar fire source of 1 ㎡, a matrix of nozzles releasing 120-140 g/s of LPG, is used to heat up the wall and the tank beyond, mimicking heat transfer from burning exterior wall finishes. The feasibility is tested by inspecting structural integrity after test, and then by examining temperatures at both sides of panels and tank's front surface as well as heat fluxes. As a result, it can be concluded that, among the suggested sample materials, fire-proof wall with ALC panel only showed the feasibility for explosion prevention with the proven evidences of structural integrity and least increase in temperature of tank.

A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy (다중이용업소의 내장재 규정의 적용에 관한 연구)

  • 이주헌;윤명오;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.100-107
    • /
    • 2001
  • A Interior material, a main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Nonetheless, it has been used recklessly with undue attention to its contribution to fire in particular in entertainment occupancy and causes many victims in fire. Therefore, this study attempts to examine the current use of interior material in Korea and find out what to be improved and enhanced in terms of related regulations. Based on the comparison and analysis of the Korea regulation with those of advanced nations, suggestions are made for an effective and efficient improvement and complement to the current system. What can be suggested from this study are as follows. The use of interior material should be controlled under the unified regulation of fire-safety codes. Code should be set up so that the current construction enforcement should be applied in retroactive to those entertainment buildings that obtained a license prior to the implementation of the system certifying that the building is fire-resistant and fire-protective. The legislation should be made to control the fire-protection facilities of small-sized, underground entertainments. It should be obliged to present the blueprint displaying the use of interior material at the time of changing occupancy. Or, it should be compelled to report changes that go way without permit to the administrative office. A compulsory provision should be set up to have a fire-resistant performance to movable furniture. The classification index designating the fire hazard of interior material by flame spread rate and smoke toxicity and its test method should be established.

  • PDF

An Indoor Pedestrian Simulation Model Incorporating the Visibility (가시성을 고려한 3차원 실내 보행자 시뮬레이션 모델)

  • Kwak, Su-Yeong;Nam, Hyun-Woo;Jun, Chul-Min
    • Spatial Information Research
    • /
    • v.18 no.5
    • /
    • pp.133-142
    • /
    • 2010
  • Many pedestrian or fire evacuation models have been studied last decades for modeling evacuation behaviors or analysing building structures under emergency situations. However, currently developed models do not consider the differences of visibility of pedestrians by obstacles such as furniture, wall, etc. The visibility of pedestrians is considered one of the important factors that affect the evacuation behavior, leading to making simulation results more realistic. In order to incorporate pedestrian's visibility into evacuation simulation, we should be able to give different walking speeds according to differences of visibility. We improved the existing floor field model based on cellular automata in order to implement the visibility. Using the space syntax theory, we showed how we split the indoor spaces depending on the different visibilities created by different levels of structural depths. Then, we improved the algorithm such that pedestrians have different speeds instead of simultaneous movement to other cells. Also, in order for developing a real time simulation system integrated w ith indoor sensors later, we present a process to build a 3D simulator using a spatial DBMS. The proposed algorithm is tested using a campus building.

A Study on Development of Disaster Prevention Automation System on IT using One-chip Type PLC (원칩형 PLC를 이용한 IT 기반 방재용 자동화시스템 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.97-104
    • /
    • 2011
  • This paper deals with the quick and precise disaster prevention automation system (DPAS) based on information communication technology (IT) that detects fire and disasters in the building automatically and quickly and then activates the facilities to extinguish fire and disasters, monitoring such situation in a real time through wire-wireless communication network. The proposed DPAS is applied a programmable logic controller (PLC) of one-chip type which is smallsize and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLC analyzes detected signals from sensors in a case of fire and disasters, then activates fire extinguishing facilities for rapid suppression. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication. The transferred data sounds an emergency alarm signal, and operates a monitoring program. The proposed DPAS based on IT will minimize the life and wealth loss from rapid measures while prevents fire and disasters.

Characteristics of Air Egress Velocity in Vestibule Pressurization System Using the Fire Dynamics Simulator (FDS를 이용한 특별피난계단 부속실 제연설비의 방연풍속 기류특성)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Choi, Keum-Ran
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.153-159
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system installed at vestibule of smokeproof stairway in domestic high-rise building becomes back-flow to stair-lobby at upper vestibule. Rather it do not back-flow to the livingroom. when fire occur and the door opens to escape from fire zone. so we carry out actual and computational fluid dynamics measurement. In the case upward 45 gradient of supply damper's blade, The simulation results that air flow of upper vestible is steady but back-flow phenomenon occurred at the bottom. However, in the case of $4m^2$, direction of the flow was ideal to living room. If a vestibule’s area is smaller, it must be designed and built according to performance-based design.

Comparison of Egress Modeling and Experiments for Flow Rate in the Bottleneck (병목현상 시 유동률에 대한 피난실험 및 모델링 비교)

  • Hwang, Eun-Kyoung;Woo, Sujin;Kim, Jong-Hoon;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.35-40
    • /
    • 2014
  • Bottleneck occurs as many people crowd into narrow doorway or corridor. Delaying egress time is occurred by bottleneck effect, and it is very important phenomenon on the egress analysis for building fire. An analysis of egress time should includes flow rate for considering bottleneck. Flow rate is numbers of people who pass the narrow gate as door or start point of corridor per unit length and unit time. The flow rate resulted from egress modeling should be approached to the result of experiments. In this study, flow rates from modeling by 'Pathfinder' and experiments was compared. The difference between the result from egress modeling and the one from experiments was verified. The average value of experiments is $4.25N/m{\cdot}s$, and the maximum average value of modeling is $1.55N/m{\cdot}s$.

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Damper Locationfor Uniform Air Egress Velocity in the case of Two Fire Doors (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 2개 출입문이 존재할 경우 균일한 방연풍속을 얻기 위한 댐퍼 위치 선정방법)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.1-7
    • /
    • 2014
  • Vestibule pressurization system should produce uniform air egress velocity to prevent the intrusion of smoke into escape route when fire accidents occur inside a building and fire doors are open for evacuation of people. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where two doors are installed varying the location of a damper and louver angle. From simulations, we found that when the damper in the vestibule is located at the center of the wall opposite to two fire doors, the uniform air egress velocity can be obtained.

The Research of the Analysis of Movement from a Fire using RTLS System (RTLS 시스템을 활용한 화재시 행동분석 연구)

  • Lim, Kyung-Bum;Kim, Ha-Young;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.98-103
    • /
    • 2010
  • The design disaster prevention of first consideration is security for the people in the buildings. However, it is difficult to make a project for considering variable cases, declined visibility of smoke, distance from another person, mentality, knowledge of clearway etc. This study purpose is, analysis variable cases and modularization of pattern movement to practice basic information for evacuation of simulation which is used RTLS (Real Time Location System) system. It is useful to sense the electric waves from the Tag and grasp the real-time position. The pattern movement of evacuation were analyzed prescription eyeglasses which is used RTLS system to consider following 3 actions; analysis of relations that declined visibility effect the decline of movement velocity, analysis rate of flow with the size of door to estimate the optimum size of door in building and analysis the pattern movement that a bottleneck situation with abundant of people passed together to these exit. The confirmed of propriety of the interpretation about the actual people to evacuate is expected applying the numerical formula in various situation.

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Characteristics of Air Flow in the Vestibule with Multiple Fire Doors in an Apartment Building (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 공동주택 부속실내에 다수 출입문의 존재시 기류특성)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.30-36
    • /
    • 2014
  • The pressurized smoke control system in the vestibule is important for fire safety in buildings because it is concerned with egress time of people and the safety of fire fighters. The vestibule pressurization system can prevent smoke from entering the vestibule using differential pressure when fire doors are closed and using the egress velocity when fire doors are open. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule in order to assure the uniform air egress velocity through a fire door when it is open. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where multiple doors are installed and it was found that the reverse flow occurs when the damper position in vestibule is not appropriate.

A Study on the Improvement Direction of the Building Escape Regulation Considering Inconvenient Movers (이동약자를 고려한 건축물 피난규정 개선 방안에 관한 연구)

  • Hwang, Eun-Kyoung
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.32-38
    • /
    • 2009
  • Owing to increase of the large-scaled, high-raised and complexed building construction, the escape design of the building became very important issue to insure the safety of occupant. Specially, it is demanded to have building escape regulation considering for inconvenient movers such as disables elders pregnant women. However, building regulations for inconvenient movers are divided into "Regulation of Escape and Fire-prevention of Building" and "Act on the Promotion and Guarantee of Access for the Disabled, the Aged and Pregnant Women to Facilities and Information". But, for the escape security of inconvenient movers, the connection of each regulation are necessary. So this study suggested the improvement direction of the building escape regulation considering inconvenient movers through the compared analysis on the "Regulation of Escape and Fire-prevention of Building" and "Act on the Promotion and Guarantee of Access for the Disabled, the Aged and Pregnant Women to Facilities and Information".