• Title/Summary/Keyword: 건물외벽

Search Result 121, Processing Time 0.025 seconds

Development for Improvement Methodology of Radiation Shielding Evaluation Efficiency about PWR SNF Interim Storage Facility (PWR 사용후핵연료 중간저장시설의 몬테칼로 차폐해석 방법에 대한 계산효율성 개선방안 연구)

  • Kim, Taeman;Seo, Myungwhan;Cho, Chunhyung;Cha, Gilyong;Kim, Soonyoung
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.92-100
    • /
    • 2015
  • For the purpose of improving the efficiency of the radiation impact assessment of dry interim storage facilities for the spent nuclear fuel of pressurized water reactors (PWRs), radiation impact assessment was performed after the application of sensitivity assessment according to the radiation source term designation method, development of a 2-step calculation technique, and cooling time credit. The present study successively designated radiation source terms in accordance with the cask arrangement order in the shielding building, assessed sensitivity, which affects direct dose, and confirmed that the radiation dosage of the external walls of the shielding building was dominantly affected by the two columns closest to the internal walls. In addition, in the case in which shielding buildings were introduced into storage facilities, the present study established and assessed the 2-step calculation technique, which can reduce the immense computational analysis time. Consequently, results similar to those from existing calculations were derived in approximately half the analysis time. Finally, when radiation source terms were established by adding the storage period of the storage casks successively stored in the storage facilities and the cooling period of the spent nuclear fuel, the radiation dose of the external walls of the buildings was confirmed to be approximately 40% lower than the calculated values; the cooling period was established as being identical. The present study was conducted to improve the efficiency of the Monte Carlo shielding analysis method for radiation impact assessment of interim storage facilities. If reliability is improved through the assessment of more diverse cases, the results of the present study can be used for the design of storage facilities and the establishment of site boundary standards.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.

A Methodology of Seismic Damage Assessment Using Capacity Spectrum Method (능력 스펙트럼법을 이용한 건물 지진 손실 평가 방법)

  • Byeon, Ji-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.1-8
    • /
    • 2005
  • This paper describes a new objective methodology of seismic building damage assessment which is called Advanced Component Method(ACM). ACM is a major attempt to replace the conventional loss estimation procedure, which is based on subjective measures and the opinions of experts, with one that objectively measures both earthquake intensity and the response ol buildings. First, response of typical buildings is obtained analytically by nonlinear seismic static analysis, push-over analyses. The spectral displacement Is used as a measure of earthquake intensity in order to use Capacity Spectrum Method and the damage functions for each building component, both structural and non-structural, are developed as a function of component deformation. Examples of components Include columns, beams, floors, partitions, glazing, etc. A repair/replacement cost model is developed that maps the physical damage to monetary damage for each component. Finally, building response, component damage functions, and cost model were combined probabilistically, using Wonte Carlo simulation techniques, to develop the final damage functions for each building type. Uncertainties in building response resulting from variability in material properties and load assumptions were incorporated in the Latin Hypercube sampling technique. The paper also presents and compares ACM and conventional building loss estimation based on historical damage data and reported loss data.

Numerical Simulation for Prediction of Existing Cavity Location on Earthquake-Induced Building Collapse (지진에 의한 건축물 붕괴 시 매몰공동 위치 예측에 관한 수치해석 사례 연구)

  • Jung, Jahe;Park, Hoon;Kim, Kwang Yeom;Shin, Hyu-Soung
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.613-621
    • /
    • 2015
  • The most urgent measure to be taken for a rapid rescue when a building collapse happens is to designate or predict a possible location where human beings are alive. It is, however, very difficult to find and correctly designate such cavities by conventional geophysical survey due to a pile of debris of building members. In this study, the simulation of building collapse induced by an earthquake was conducted to predict forming pattern of a existing cavities. The simulation cases included the influence of structure wall existence and height of building. Three types of building structure: five-story, ten-story and fifteen-story were prepared as a simulation case. In the case of high building, a collapse range on the inside of the building increased consequently lowering the possibility of lifeguard cavern forming. In addition, when a wall exists in the basement floor, the possibility that existing cavities could be formed increased compared to the cases without wall.

Development of PV/T for Performance Improvement of Photovoltaic System (태양광 발전의 성능향상을 위한 PV/T 시스템 개발)

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.173-181
    • /
    • 2011
  • This paper proposes photovoltaic thermal hybrid module to get the electrical and thermal performance of building integrated photovoltaic(BIPV) system. BIPV system is decreased the system efficiency because output of PV is decreased by the thermal rising on generating. In order to improve the efficiency of BIPV module, water cooling system is applied and generated thermal is used the warm water system. Water cooling system uses the flux control algorithm considering water temperature and power loss. Electrical and thermal performance of proposed photovoltaic thermal hybrid module is confirmed through the actual experiment and herby proved the valid of this paper.

A Numerical Analysis on the Outside Pressure Distribution by Outdoor Wind Effect in a High-rise Residential Building (수치해석을 이용한 초고층 주거건물에서 외풍영향에 의한 외벽 압력 분포 분석)

  • Kim, Chi-Wan;Yang, Soon-Chang;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.639-645
    • /
    • 2011
  • The object of this study is to analyze and evaluate outdoor wind pressure effect in a high-rise residential building when seasonal wind blow on coast area. The target building consists of 3 tower buildings over 250m in height. For the evaluation of the outdoor wind effect, CFD simulation was performed. The results of the simulations are as follows : 1) In that case of high-rise building, horizontal stream is more affected than vertical stream. 2) In case of summer season northeasterly wind, building pressure distributions are unstable and surface pressures of outside are effected respectively. 3) In case of winter season westerly wind, building preassure differentiations are not so much because of screening effects of the B, and the C buildings. 4) In case of winter season northwesterly wind, front wind affects on the A building directly because of no obstacles.

A Study on NLOS Error Solution Method in Indoor Location Estimate (실내 위치 추정에서의 비가시선(NLOS) 문제 해결 방안에 관한 연구)

  • Woo Sung-Hyun;Jeon Hyun-Sik;Park Hyun-Ju
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.06d
    • /
    • pp.178-180
    • /
    • 2006
  • 실내 위치 환경에서 많이 사용되고 있는 삼각 측량 기법은 TOA(Time of Arrival) 신호를 사용하기 때문에 건물의 외벽이나 창의 메탈 성분 같은 장애물로 인한 전파의 반사와 회절, 분산 등의 NLOS(Non-Line-Of-Sight) 환경으로 인하여 정확한 위치추적이 어렵다는 문제점이 있다. 따라서 본 논문은 이러한 문제점을 줄이기 위해서 Anchor로부터 수신되는 TOA의 range measurement의 표준 편차를 측정하여 LOS와 NLOS를 구분하고, 발견된 NLOS를 보정하는 방법에 대하여 연구한다. 또한 위치 정확도를 높이기 위하여 칼만 필터를 수행하여 이동객체의 위치를 생성하는 실내 환경에서의 위치 추적 시스템을 설계한다.

  • PDF

Comparative Evaluation of Albedo Distribution among Administrative Districts (행정구역별 알베도 분포 비교 평가)

  • Kim, Ki-Youl;Um, Jung-Sup
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2010.09a
    • /
    • pp.384-386
    • /
    • 2010
  • 본 연구의 목적은 도시고온화와 도시열섬 현황을 파악하는데 있어 중요한 역할을 하는 도시 지역의 알베도와 지표면의 토지이용 자료를 이용하여 한반도 행정구역의 알베도 분포를 비교 평가하고자 하는 것이다. 도시 지역의 알베도와 토지이용을 현장조사 할 경우 많은 시간과 비용이 소요되기 때문에, 시간적 경제적인 비용절감효과를 위해 전 지구적으로 변화를 감지할 수 있도록 NASA에서 제공하는 MODIS 위성영상 자료를 사용하여 분석하였으며, 그 결과 서울, 부산, 대구 등 주요 도시를 중심으로 대체적인 알에도 값이 낮게 나타났다. 이는 도시 지역의 인공 환경의 영향으로 인하여 주요 도시 지역이 주변 지역보다 알베도 수치가 낮게 나타났음을 알 수 있고 이러한 알베도 수치는 도시 열환경에 직접적인 영향을 주고 있으며 따라서 도시고온화와 도시열섬 현상을 감소시키기 위하여 도시 내 빌딩 및 도로의 재질개선, 지붕 및 도로 포장, 건물의 외벽을 밝은 색으로 교체 등의 방법으로 지표면 알베도를 높이기 위한 방안 마련이 시급 할 것이다.

  • PDF

3층 규모 건물이 있는 콘크리트 플로팅 함체의 설계 연구

  • Lee, Yeong-Uk;Park, Jeong-A;Choe, Ji-Hun;Park, Tae-Jun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.419-421
    • /
    • 2012
  • 높이 2.5m의 콘크리트 플로팅 함체에 3층 규모의 상부골조가 있는 예제에 대해 동적 유체 해석과 정적 구조 해석을 수행하고 그 결과에 따라 종방향설계, 함체의 상부 및 하부 슬래브, 외벽 및 격벽에 대한 설계를 수행하였다. 환경 하중은 새만금 방파제 내부 정수역을 기준으로 파도주기 3.7초, 유의파고 1.0m와 풍속 40m/s를 적용하였으며, 하중조합은 ASCE/SEI 7-10을 기준으로 설계 하였다. 예제 구조물에 대한 설계 결과 고정하중에 의한 영향이 활하중 및 파랑하중에 비해 크게 나타났으며, 이로 인해 중앙부의 철근비가 높아지므로 고정하중을 감소시키는 방안을 검토하여야 함을 확인하였다. 또한 보의 지속하중에 의한 장기처짐과 추가적인 활하중에 의한 순간 처짐의 값이 허용 처짐값보다 크므로 보에서의 프리스트레싱을 고려해야 할 것으로 판단된다.

  • PDF

A Experimental Study on Finished Envelope Performance of BIPV Module (Mock-up실험을 통한 BIPV Module의 외벽 성능평가)

  • Yi, So-Mi;Yoon, Chul;Lee, Yong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.251-256
    • /
    • 2008
  • Nowaday, The Sustainable Development about global environment is the most important subject. In urban environment, a variety of the nature energy utilization such as the solar energy are the most efficient solution to solve this issue. One of these efficient solutions, a photovoltaic system using sunlight has been introduced to the building with an advantage such as cost-effective, safe for using and good for environment friendly in light with energy utilization. The BIPV is one of the most interesting and promisingly possibilities of an active use of solar energy at the building. Therefore the goal of this study is to get securing the application information of BIPV as finished envelope. The purpose of this study is to investigate the current performance measurement methods of BIPV module and to measure the performance of BIPV module by mock-up tests.

  • PDF