• Title/Summary/Keyword: 거친 표면 임플란트

Search Result 7, Processing Time 0.031 seconds

The effects of local factors on the survival of dental implants: A 19 year retrospective study (임플란트의 생존율에 영향을 미치는 국소적 인자에 대한 19년간의 후향적 연구)

  • Kim, Sung-Hoi;Kim, Sun-Jai;Lee, Keun-Woo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.28-40
    • /
    • 2010
  • Purpose: The aim of this retrospective study was to provide long-term data about the correlation between multifactorial local factors and the survival of implants. Material and methods: During 19 years (1991 to 2009), 2796 implants were placed in 879 patients. From dental charts and radiographs, the following data were collected: patient's age at implant placement, gender, implant system, surface, length, diameter, location of implant placement, bone quality, primary stability, type of prosthesis. The correlations between these data and implant survival were analyzed. Statistical analysis was performed using Kaplan-Meier survival analysis, Chi-square test, odds ratio. Results: 1. Among the 2796 implants, 150 implants failed that resulted in a cumulative survival rate of 94.64%. The cumulative survival rate of smooth surface implants (91.76%) was lower than rough surface implants (96.02%). 2. Anatomic location, implant surface, diameter of smooth surface implant, primary stability, type of prosthesis, patient's age and gender were significantly associated with implant survival (P < .05). 3. No significant difference in implant survival was found in relation to the following factors: implant length, bone quality, diameter of rough surface implants and type of rough surface according to implant manufacturer (P < .05). Conclusions: Local factors such as anatomic location, implant surface, diameter of smooth surface implant, primary stability and type of prosthesis have a significant effect on implant survival.

On the osseointegration of zirconia and titanium implants installed at defect site filled with xenograft material (이종골 이식을 동반한 지르코니아와 타이타늄 임플란트의 골유착에 관한 연구)

  • Kim, Sung-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose: The purpose of this study was to compare zirconia implants with titanium implants from the view point of biomechanical stability and histologic response on osseointegration when those were placed with xenograft materials. Materials and methods: Specimens were divided into two groups; the control group was experimented with eighteen titanium implants which had anodized surface and the experimental group was experimented with eighteen sandblasted zirconia (Y-TZP) implants. At the tibias of six pigs, implants were installed into bone defect sites prepared surgically and treated with resorbable membranes and bovine bone. Two pigs were sacrificed after 1, 4 and 12 weeks respectively. Each implant site was sampled and processed for histologic and histomorphometric analysis. The stability of implants was evaluated with a $Periotest^{(R)}$. And the interfaces between bone and the implant were observed with a scanning electron microscope. Results: In stability analysis there was no significant difference between Periotest values of the control group and the experimental group. In histologic analysis with a light microscope after 4 weeks, there was new bone formation with the resorption of bovine bone and the active synthesis of osteoblasts in both groups. In bone-implant contact percentage there was significant difference between both groups (P<.05). In bone area percentage there was no significant difference between both groups. In analysis of both groups with a scanning electron microscope there was a gap between bone and a surface at 4 weeks and it was filled up with bone formed newly at 12 weeks. Conclusion: When accompanied by xenograft using membrane, bone to implant contact percentage of zirconia implants used in this experiment was significantly less than that of the titanium implants by surface treatment of anodic oxidation. So, it is considered that the improvement of zirconia implant is needed through ongoing research on surface treatment methods for its practical use.

Surface characteristics and stability of implants treated with alkali and heat (알칼리와 열처리에 의한 임플란트의 표면 특성 및 골유착 안정성에 관한 연구)

  • Song, Yun-Seok;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.490-499
    • /
    • 2008
  • Statement of problem: Bioactive materials must have the ability to spontaneously form a bone like apatite layer on their surface and induce direct biochemical bonding to bone. A simple chemical treatment via alkali and heat has been revealed to induce bioactivity in titanium. Purpose: The purpose of this study was to evaluate the surface characteristics and stability of alkali and heat treated implants. Material and methods: Specimens were divided into three groups; group 1 was the control group with machined surface implants, groups 2 and 3 were treated with alkali solutions and heat treated in the atmosphere and vacuum conditions respectively. The surface characteristics were observed with FESEM, XPS, TF-XRD and AFM. Stability was evaluated with the resonance frequency analysis, periotest and removal torque values. One-way ANOVA and Duncan test were used for statistical analysis. Results: 1. Groups treated with alkali and heat showed similar characteristics. Groups 2 and 3 showed high compositions of Na ions on the surface with sub-micron sized pores compared to group 1. Group 2 showed mixed compositions of anatase and rutile with superior contents of rutile. 2. Resonance frequency analysis : The ISQ of group 2 showed significantly higher values than that of groups 1 and 3 at 12 weeks. The ISQ of groups 1 and 2 showed significant increase after 4 weeks, and the ISQ of group 3 increased significantly after 2 and 4 weeks respectively (P < .05). 3. Periotest: The PTV of groups 1 and 2 showed significant decrease after 4 weeks, and the PTV of group 3 showed significant decrease after 2 and 4 weeks respectively (P < .05). 4. Removal torque analysis: The removal torque value of group 2 was significantly higher than those of groups 1 and 3 at 2, 4 and 8 weeks. The removal torque values of groups 1 and 3 showed increase at 4 and 12 weeks, but the removal torque value of group 2 showed increase after 4 weeks (P < .05). Conclusion: An oxide layer with appropriate crystal structure and amorphous sodium titanate layer can be obtained on titanium implants through alkali and heat treatment in the atmosphere, and even alkali and heat treatment in vacuum conditions, provided a bioactive surface containing sodium. These surface layers can be considered to be effective for enhancement of osseointegration and reduction of healing period for implant treatment.

Improvement of Calcium Phosphate Forming Ability of Titanium Implant by Thermal Oxidation Method (열산화법에 의한 티타늄 임플란트의 인산칼슘 결정의 형성 능력 증진)

  • Hwang, Kyu-Seog;An, Jun-Hyung;Lee, Seon-Ok;Yun, Yeon-Hum;Kang, Bo-An;Oh, Jeong-Sun;Kim, Sang-Bok
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.5
    • /
    • pp.460-466
    • /
    • 2002
  • Titanium oxide film was deposited on the commercially pure titanium (cp-Ti) by thermal oxidation method for its medical application. The cp-Ti disks were cleaned and then heat-treated at the temperatures of 500, 550, 600, 650, and 700${\circ}C$, respectively, for 10 min in air or Ar. To test the ability of calcium phosphate formation, the specimens were immersed in the Eagle's minimum essential medium solution at 36.5${\circ}C$ for 15 days. The morphology and chemical composition of the surfaces before and after soaking were analyzed by using FE-SEM and EDS. The in-vitro formation of carbonated calcium phosphate on the thin films containing nano-sized $TiO_2$ crystals was identified.

An Evaluation of Antibacterial Titanium Surface For Dental Implant (치과용 임플란트 적용을 위한 항균력을 가진 티타늄 표면의 평가)

  • Kang, Min-Kyung;Moon, Seung-Kyun;Kim, Kyoung-Nam
    • Journal of dental hygiene science
    • /
    • v.11 no.5
    • /
    • pp.405-410
    • /
    • 2011
  • The aim of this study was to evaluate antibacterial effect of Cl coated titanium. To coat the Cl on the titanium, first, the titanium was modified by blasting treatment with hydroxyapatite and alumina powder. Anodization process was completed using electrolyte solution of 0.04 M ${\beta}$-glycerol phosphate disodium salt n-hydrate, 0.4 M calcium acetate n-hydrate and 1 M NaCl on the condition of 250 voltages for 3 min. Surface morphology and elements' observation were performed with scanning electron microscopy and energy dispersive spectroscopy and surface profiler was used to analyze the surface roughness. Antibacterial effect was evaluated by film adhesion method. The anodized titanium after blasting showed dimpled surface contained the Cl. Surface average roughness of these surfaces had significantly higher compared to polished titanium. Result of antibacterial test showed that anodized titanium after blasting had an enhanced antibacterial effect compared to the polished titanium. Therefore, these results suggested that titanium contained Cl by anodization after blasting had a rough surface as well as antibacterial effect.

HISTOMORPHOMETRIC EVALUATION OF OSTEOGENESIS WITH BRUSHITE IMPLANT SURFACES IN DOGS (성견에서 거친 표면을 가지는 임플란트에서 골형성에 관한 조직형태계측학적인 평가)

  • Moon, Chul-Woong;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong;Lim, Sung-Chul;Oh, Ji-Su;Baik, Sung-Mun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.2
    • /
    • pp.150-157
    • /
    • 2008
  • This study evaluated the influence of smooth and brushite-coated implant surfaces in dogs. The first through fourth mandibular premolars were extracted from eight young adult dogs. Twelve weeks after extraction. implantation was performed at the extraction sites. In total, 40 implant fixtures were implanted in the dog mandibles. Twenty machined implants served as controls and twenty brushite-coated surfaces served as tests. Dogs were sacrificed 2 and 4 weeks after implantation. The hemi-mandibles were obtained and processed histologically to obtain non-decalcified sections. Longitudinal sections of each implant were made and analyzed using light microscopy. The overall implant success rate was 83.3%. Histomorphometrically. the experimental group had a better percentage of bone-implant contact than the control group (p<0.05) and there was a significant difference between the 2- and 4-week groups after implantation (p<0.05) Our results suggest that the implant surface morphology influences the increase in peri-implant osteogenesis in the early period of peri-implant healing.

Analysis of attachment, proliferation and differentiation response of human mesenchymal stem cell to various implant surfaces coated with rhBMP-2 (다양한 rhBMP-2 코팅 임플란트 표면에서의 인간 간엽 줄기세포의 부착, 증식, 분화반응 분석)

  • Lee, In-Ku;Han, In-Ho;Hwang, Sun-Wook;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.44-52
    • /
    • 2012
  • Purpose: In this paper we tried to evaluate the most appropriate surface for rhBMP-2 coating among 4 rough titanium surfaces. Materials and methods: We used machined surface as a control group and anodized, RBM and SLA surfaces as test groups. We coated rhBMP-2 on the 4 surfaces and with uncoated surfaces for each case, we cultured human mesenchymal stem cells on all 8 surfaces. 24 hours after we measured the stem cell' attachment with SEM, and on 3rd, 7th, and 14th days, we checked the cell proliferation and differentiation by using MTT and ALP activity assay. And on the 7th day after the culture, we performed RT-PCR assay to determine whether the expression levels of Type I collagen, osteocalcin, osteopontin were changed. Results: We observed with SEM that 4 rhBMP-2 coated surfaces exhibited wider and tighter cell attachment and more cell process spreading than uncoated surfaces. The anodized rhBMP-2 surface caused robustest effects. In MTT assay we could not find any meaningful difference. In ALP assay there was a significant increase (P<.05) in the ALP activity of anodized rhBMP-2 coated surface compared with that of the control (3rd and 14th days) and with that of the RBM rhBMP-2 coated surface (14th day). In RT-PCR assay there was increased expressions in the anodized rhBMP-2 coated surface for osteocalcin, and osteopontin. Conclusion: We found that the anodized rhBMP-2 coated surface were most prominent stem cell attachment and differentiation in compared to control and Machined rhBMP-2 coated, RBM rhBMP-2 coated surface.