• Title/Summary/Keyword: 거리 공간

Search Result 2,400, Processing Time 0.038 seconds

The Applicability of Conditional Generative Model Generating Groundwater Level Fluctuation Corresponding to Precipitation Pattern (조건부 생성모델을 이용한 강수 패턴에 따른 지하수위 생성 및 이의 활용에 관한 연구)

  • Jeong, Jiho;Jeong, Jina;Lee, Byung Sun;Song, Sung-Ho
    • Economic and Environmental Geology
    • /
    • v.54 no.1
    • /
    • pp.77-89
    • /
    • 2021
  • In this study, a method has been proposed to improve the performance of hydraulic property estimation model developed by Jeong et al. (2020). In their study, low-dimensional features of the annual groundwater level (GWL) fluctuation patterns extracted based on a Denoising autoencoder (DAE) was used to develop a regression model for predicting hydraulic properties of an aquifer. However, low-dimensional features of the DAE are highly dependent on the precipitation pattern even if the GWL is monitored at the same location, causing uncertainty in hydraulic property estimation of the regression model. To solve the above problem, a process for generating the GWL fluctuation pattern for conditioning the precipitation is proposed based on a conditional variational autoencoder (CVAE). The CVAE trains a statistical relationship between GWL fluctuation and precipitation pattern. The actual GWL and precipitation data monitored on a total of 71 monitoring stations over 10 years in South Korea was applied to validate the effect of using CVAE. As a result, the trained CVAE model reasonably generated GWL fluctuation pattern with the conditioning of various precipitation patterns for all the monitoring locations. Based on the trained CVAE model, the low-dimensional features of the GWL fluctuation pattern without interference of different precipitation patterns were extracted for all monitoring stations, and they were compared to the features extracted based on the DAE. Consequently, it can be confirmed that the statistical consistency of the features extracted using CVAE is improved compared to DAE. Thus, we conclude that the proposed method may be useful in extracting a more accurate feature of GWL fluctuation pattern affected solely by hydraulic characteristics of the aquifer, which would be followed by the improved performance of the previously developed regression model.

Study on Spatial Change of Urban Forest Considering Definition of Urban Area in South Korea (도시지역 정의에 따른 도시숲의 공간적 변화에 관한 연구)

  • Doo-Ahn, KWAK;So-Hee, PARK
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.4
    • /
    • pp.19-31
    • /
    • 2022
  • The definition of urban forest is described as all forest and trees except the Natural Parks throughout whole territory in Urban Forest Act. But the concept of urban forest in the law differs from general awareness by Korean citizen and from definitions of other countries. For discussing such differences of urban forest definition, it was tested how much urban forest area would be changed according to the various definition of urban area. The urban area was defined to be four scenarios in this study in consideration of "urban area" by National Land Planning and Utilization Act (NLPUA), 300m buffered boundary from the "urban area" proposed by World Health Organization (WHO) and forest watershed area. In the scenario 1, including forest watershed intersected with "urban area" by NLPUA, urban forest area was estimated at 1.83 million ha in which urban forest area per person was 386㎡. In the scenario 2, including forest watershed intersected with 300m buffered boundary from the "urban area" by NLPUA, urban forest area was estimated at 1.92 million ha in which urban forest area per person was 405㎡. In the scenario 3, including forest watershed intersected with "urban area" placed within administration boundary (Eup·Dong districts), urban forest area was estimated at 1.08 million ha in which urban forest area per person was 230㎡. In the scenario 4, including forest watershed intersected with 300m buffered boundary from "urban area" placed within administration boundary, urban forest area was estimated at 1.20 million ha in which urban forest area per person was 256㎡. Therefore, the boundary of urban area should be agreed clearly prior to defining the urban forest area for avoiding unclear area calculated according to different definitions.

Calculation of Soil Moisture and Evapotranspiration for KLDAS(Korea Land Data Assimilation System) using Hydrometeorological Data Set (수문기상 데이터 세트를 이용한 KLDAS(Korea Land Data Assimilation System)의 토양수분·증발산량 산출)

  • PARK, Gwang-Ha;LEE, Kyung-Tae;KYE, Chang-Woo;YU, Wan-Sik;HWANG, Eui-Ho;KANG, Do-Hyuk
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.4
    • /
    • pp.65-81
    • /
    • 2021
  • In this study, soil moisture and evapotranspiration were calculated throughout South Korea using the Korea Land Data Assimilation System(KLDAS) of the Korea-Land Surface Information System(K-LIS) built on the basis of the Land Information System (LIS). The hydrometeorological data sets used to drive K-LIS and build KLDAS are MERRA-2(Modern-Era Retrospective analysis for Research and Applications, version 2) GDAS(Global Data Assimilation System) and ASOS(Automated Synoptic Observing System) data. Since ASOS is a point-based observation, it was converted into grid data with a spatial resolution of 0.125° for the application of KLDAS(ASOS-S, ASOS-Spatial). After comparing the hydrometeorological data sets applied to KLDAS against the ground-based observation, the mean of R2 ASOS-S, MERRA-2, and GDAS were analyzed as temperature(0.994, 0.967, 0.975), pressure(0.995, 0.940, 0.942), humidity (0.993, 0.895, 0.915), and rainfall(0.897, 0.682, 0.695), respectively. For the hydrologic output comparisons, the mean of R2 was ASOS-S(0.493), MERRA-2(0.56) and GDAS (0.488) in soil moisture, and the mean of R2 was analyzed as ASOS-S(0.473), MERRA-2(0.43) and GDAS(0.615) in evapotranspiration. MERRA-2 and GDAS are quality-controlled data sets using multiple satellite and ground observation data, whereas ASOS-S is grid data using observation data from 103 points. Therefore, it is concluded that the accuracy is lowered due to the error from the distance difference between the observation data. If the more ASOS observation are secured and applied in the future, the less error due to the gridding will be expected with the increased accuracy.

Steel Plate Faults Diagnosis with S-MTS (S-MTS를 이용한 강판의 표면 결함 진단)

  • Kim, Joon-Young;Cha, Jae-Min;Shin, Junguk;Yeom, Choongsub
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.1
    • /
    • pp.47-67
    • /
    • 2017
  • Steel plate faults is one of important factors to affect the quality and price of the steel plates. So far many steelmakers generally have used visual inspection method that could be based on an inspector's intuition or experience. Specifically, the inspector checks the steel plate faults by looking the surface of the steel plates. However, the accuracy of this method is critically low that it can cause errors above 30% in judgment. Therefore, accurate steel plate faults diagnosis system has been continuously required in the industry. In order to meet the needs, this study proposed a new steel plate faults diagnosis system using Simultaneous MTS (S-MTS), which is an advanced Mahalanobis Taguchi System (MTS) algorithm, to classify various surface defects of the steel plates. MTS has generally been used to solve binary classification problems in various fields, but MTS was not used for multiclass classification due to its low accuracy. The reason is that only one mahalanobis space is established in the MTS. In contrast, S-MTS is suitable for multi-class classification. That is, S-MTS establishes individual mahalanobis space for each class. 'Simultaneous' implies comparing mahalanobis distances at the same time. The proposed steel plate faults diagnosis system was developed in four main stages. In the first stage, after various reference groups and related variables are defined, data of the steel plate faults is collected and used to establish the individual mahalanobis space per the reference groups and construct the full measurement scale. In the second stage, the mahalanobis distances of test groups is calculated based on the established mahalanobis spaces of the reference groups. Then, appropriateness of the spaces is verified by examining the separability of the mahalanobis diatances. In the third stage, orthogonal arrays and Signal-to-Noise (SN) ratio of dynamic type are applied for variable optimization. Also, Overall SN ratio gain is derived from the SN ratio and SN ratio gain. If the derived overall SN ratio gain is negative, it means that the variable should be removed. However, the variable with the positive gain may be considered as worth keeping. Finally, in the fourth stage, the measurement scale that is composed of selected useful variables is reconstructed. Next, an experimental test should be implemented to verify the ability of multi-class classification and thus the accuracy of the classification is acquired. If the accuracy is acceptable, this diagnosis system can be used for future applications. Also, this study compared the accuracy of the proposed steel plate faults diagnosis system with that of other popular classification algorithms including Decision Tree, Multi Perception Neural Network (MLPNN), Logistic Regression (LR), Support Vector Machine (SVM), Tree Bagger Random Forest, Grid Search (GS), Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The steel plates faults dataset used in the study is taken from the University of California at Irvine (UCI) machine learning repository. As a result, the proposed steel plate faults diagnosis system based on S-MTS shows 90.79% of classification accuracy. The accuracy of the proposed diagnosis system is 6-27% higher than MLPNN, LR, GS, GA and PSO. Based on the fact that the accuracy of commercial systems is only about 75-80%, it means that the proposed system has enough classification performance to be applied in the industry. In addition, the proposed system can reduce the number of measurement sensors that are installed in the fields because of variable optimization process. These results show that the proposed system not only can have a good ability on the steel plate faults diagnosis but also reduce operation and maintenance cost. For our future work, it will be applied in the fields to validate actual effectiveness of the proposed system and plan to improve the accuracy based on the results.

Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique (다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구)

  • Kim, Dong-Wook;Choi, Yu-Sung;Jo, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.343-358
    • /
    • 2011
  • As implant treatment has become popular, lots of different shapes and materials of the implant upper component have been supplied. And there are also diverse reports about failures including loosening of the abutment screw which is one of the most common reason. Purpose : The purpose of this study is to find out how different screw tightening orders and methods influence on screw loosening according to the different connection systems. The upper component was fabricated by casting method. After fabricating master models that are precisely attached to the upper component, 5 experimental models each for the external connection system and internal connection system were fabricated using splinting impression technique. First, to find out the influence of the screw tightening order, screws were tightened in 3 orders; 1-2-3-4, 2-3-1-4, 2-4-3-1. After tightening, removal torque values (RTV) of each group was measured. And also to find out the influence of screw tightening method, a model with 2-3-1-4 screw tightening order was tightened with 30 Ncm at one time(1-step method) and the RTV was compared with the same order group (2-3-1-4) in the 2 step method. In the external connection system, RTV appeared significantly lower in group 2-3-1-4 than group 2-4-3-1 (p<0.05). And also in the internal connection system, the RTV of group 2-3-1-4 appeared significantly lower than that of group 2-4-3-1 and 1-2-3-4 (p<0.05). When comparing the tightening number of the screw without considering the screw tightening order, the first tightened screw appeared significantly higher RTV than the second one in the external connection system (p<0.05), however there was no significant difference from the first tightened screw to the last tightened screw in the internal connection system. And there was no statistically significant difference between the two screw tightening methods in both internal and external connection system. In the comparison of external and internal connection system, each RTV appeared 16.27 Ncm and 14.25 Ncm and appeared as a statistically significant difference (p<0.05). There was a significant difference in RTV measured according to the screw tightening order. The lowest RTV appeared in the groups started tightening from the middle. There was also a significant difference in RTV between the two connection system groups. A further study is needed to find out the influence factors in RTV and also a study is required related to the load condition.

The Outbreak of Red Tides in the Coastal Waters off Kohung, Chonnam, Korea 3. The Temporal and Spatial Variations in the Heterotrophic Dinoflagellates and Ciliates in 1997 (전남 고흥 해역의 유해성 적조의 발생연구 3. 1997년도 종속영향성 와편모류와 섬모류의 시공간적 변화)

  • Jeong, Hae-Jin;Park, Jong-Kyu;Kim, Jae-Seong;Kim, Seong-Taek;Yoon, Joo-Eh;Kim, Su-Kyeong;Park, Yong-Min
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.1
    • /
    • pp.37-46
    • /
    • 2000
  • We investigated the temporal and spatial variations in heterotrophic dinoflagellates (hereafter HTD) and ciliates from June to September 1997 in the waters off Kohung, Korea where red tides dominated by harmful dinoflagellates had occurred from August to October since 1995. We took water samples five times from 5-7 depths at 3 stations in this study period. A total of 17 HTD species were present and of these species in the genus Protoperidinium were 11. The species number of tintinnids (hereafter TIN) present totalled 15 and several naked ciliate (hereafter NC) species were observed. The species numbers of HTD and TIN rapidly increased between August 1st and 21st and then reached to the maximum numbers of 13 and 10, respectively, on August 27 when red tides dominated by Gyrodinium impudicum were first observed in the study area. However the species numbers drastically decreased on September 22. The maximum densities of HTD, TIN, and NC were 45, 39, 57 cells $ml^{-1}$, respectively. ADAS, calculated by averaging the densities of a certain species in the all samples collected from all depths and stations at a sampling period, most increased between August 1st and 21st and then reached to the maximum density of f cells $ml^{-1}$ on August 27 for HTD, while did between August 21st and 27th and up to 7 cells $ml^{-1}$ for TIN. Unlike ADAS of HTD and TIN, that of NC did not change much with the maximum of 8 cells $ml^{-1}$ on August 27th. The pattern of the temperal variation in the species number and ADAS of HTD was similar to that of diatoms and the distributions of Protoperidinium spp. and diatoms had a strong positive correlation. This evidence suggests that HTD, in particular Protoperidinium spp. be a grazer on diatom. In general, the densities of HTD, TIN, and NC decreased with going to stations located in the outer bay. Therefore, the availability of suitable prey and distance from the coastal line might be responsible for the distribution of HTD, TIN, and NC. The results of the present study provide a basis for further experiments for the feeding by dominant HTD, TIN, and NC on dominant phytoplankton including red tide species and for understanding food webs in the planktonic community before, during, and after the red tide outbreak.

  • PDF

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF

Spatio-temporal Fluctuations with Influences of Inflowing Tributary Streams on Water Quality in Daecheong Reservoir (대청호의 시공간적 수질 변화 특성 및 호수내 유입지천의 영향)

  • Kim, Gyung-Hyun;Lee, Jae-Hoon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.2
    • /
    • pp.158-173
    • /
    • 2012
  • The objectives of this study were to analyze the longitudinal gradient and temporal variations of water quality in Daecheong Reservoir in relation to the major inflowing streams from the watershed, during 2001~2010. For the study, we selected 7 main-stream sites of the reservoir along the main axis of the reservoir, from the headwater to the dam and 8 tributary streams. In-reservoir nutrients of TN and TP showed longitudinal declines from the headwater to the dam, which results in a distinct zonation of the riverine ($R_z$, M1~M3), transition ($T_z$, M4~M6), and lacustrine zone ($L_z$, M7) in water quality, as shown in other foreign reservoirs. Chlorophyll-a (CHL) and BOD as an indicator of organic matter, were maximum in the $T_z$. Concentration of total phosphorus (TP) was the highest (8.52 $mg\;L^{-1}$) on March in the $R_z$, and was the highest (165 ${\mu}g\;L^{-1}$) in the $L_z$ on July. Values of TN was the maximum (377 ${\mu}g\;L^{-1}$) on August in the $R_z$, and was the highest (3.76 $mg\;L^{-1}$) in the $L_z$ on August. Ionic dilution was evident during September~October, after the monsoon rain. The mean ratios of TN : TP, as an indicator of limiting factor, were 88, which indicates that nitrogen is a surplus for phytoplankton growth in this system. Nutrient analysis of inflowing streams showed that major nutrient sources were headwater streams of T1~T2 and Ockcheon-Stream of T5, and the most influential inflowing stream to the reservoir was T5, which is located in the mid-reservoir, and is directly influenced by the waste-water treatment plants. The key parameters, influenced by the monsoon rain, were TP and suspended solids (SS). Empirical models of trophic variables indicated that variations of CHL in the $R_z$ ($R^2$=0.044, p=0.264) and $T_z$ ($R^2$=0.126, p=0.054) were not accounted by TN, but were significant (p=0.032) in the $L_z$. The variation of the log-transformed $I_r$-CHL was not accounted ($R^2$=0.258, p=0.110) by $I_w$-TN of inflowing streams, but was determined ($R^2$=0.567, p=0.005) by $I_w$-TP of inflowing streams. In other words, TP inputs from the inflowing streams were the major determinants on the in-reservoir phytoplankton growth. Regression analysis of TN : TP suggested that the ratio was determined by P, rather than N. Overall, our data suggest that TP and suspended solids, during the summer flood period, should be reduced from the eutrophication control and P-input from Ockcheon-Stream should be controlled for water quality improvement.

A study on the strategies to lower technologist occupational exposure according to the performance form in PET scan procedure (PET 검사실 종사자의 업무 행위 별 방사선피폭 조사에 따른 피폭선량 저감화를 위한 연구)

  • Ko, Hyun Soo;Kim, Ho Sung;Nam-Kung, Chang Kyeoung;Yoon, Soon Sang;Song, Jae Hyuk;Ryu, Jae Kwang;Jung, Woo Young;Chang, Jung Chan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.17-29
    • /
    • 2015
  • Purpose For nuclear medicine technologists, it is difficult to stay away from or to separate from radiation sources comparing with workers who are using radiation generating devices. Nuclear medicine technologists work is recognized as an optimized way when they are familiar with work practices. The aims of this study are to measure radiation exposure of technologists working in PET and to evaluate the occupational radiation dose after implementation of strategies to lower exposure. Materials and Methods We divided into four working types by QC for PET, injection, scan and etc. in PET scan procedure. In QC of PET, we compared the radiation exposure controlling next to $^{68}Ge$ cylinder phantom directly to controlling the table in console room remotely. In injection, we compared the radiation exposure guiding patient in waiting room before injection to after injection. In scan procedure of PET, we compared the radiation exposure moving the table using the control button located next to the patient to moving the table using the control button located in the far distance. PERSONAL ELECTRONIC DOSEMETER (PED), Tracerco$^{TM}$ was used for measuring exposed radiation doses. Results The average doses of exposed radiation were $0.27{\pm}0.04{\mu}Sv$ when controlling the table directly and $0.13{\pm}0.14{\mu}Sv$ when controlling the table remotely while performing QC. The average doses of exposed radiation were $0.97{\pm}0.36{\mu}Sv$ when guiding patient after injection and $0.62{\pm}0.17{\mu}Sv$ when guiding patient before injection. The average doses of exposed radiation were $1.33{\pm}0.54{\mu}Sv$ when using the control button located next to the patient and $0.94{\pm}0.50{\mu}Sv$ when using the control button located in far distance while acquiring image. As a result, there were statistically significant differences(P<0.05). Conclusion: From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine. Conclusion From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine.

  • PDF

The Location and Landscape Composition of Yowol-pavilion Garden Interpreted from Tablet & Poetry (편액과 시문으로 본 요월정원림(邀月亭園林)의 입지 및 조영 해석)

  • Lee, Hyun-Woo;Kim, Sang-Wook;Ren, Qin-Hong
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.32-45
    • /
    • 2014
  • The study attempts to interpret original location and landscape composition of Yowol-pavilion Garden under the premise that tablet and poetry are important criteria for inference of unique location and landscape composition of a pavilion garden. The study raises the meaning, status, and value of Yowol Pavilion Garden as a cultural asset. The results of the study are as follows. First, Yowol-pavilion Garden was a place where famous Confucius scholars in Joseon Dynasty in 16th Century, including Kim, Kyung-Woo, the owner of the garden, used to share the taste for the arts and poetries with their colleagues. Along with a main characteristic of Yowol Pavilion Garden as a hideout for the Confucius scholars who stayed away from a political turmoil, the new place characteristic of the garden, a bridgehead for the formation of regional identity, was discovered in the record of "Joseon-Hwanyeo-Seungram Honam-Eupji JangSeong-Eupji", As described in "The first creative poetry of Yowol-pavilion", the intention for the creation of Yowol-pavilion Garden and the motive for its landscape composition is interpreted as a space of rivalry where the world, reality and ideals are mixed up. Second, related to outstanding scenic factors and natural phenomena when taking a view from the pavilion, the name of the house 'Yowol', which means 'Greeting the moon rising on the Mt. Wolbong' is the provision of nature and taste for the arts, and is directly connected to the image of leaving the worldly. In other words, the name was identified to be the one that reflected the intention for landscape composition to follow the provision of nature separating from joy and sorrow of the mundane world. Third, as for the location, it was confirmed through "YeongGwang-Soksu-Yeoji-Seungram" that Yowol-pavilion Garden was a place where the person who made the pavilion prepared for relaxation after stepping down from a government post, and literature and various poetry show that it was also a place of outstanding scenic where Yellow-dragon River meandered facing Mt. Wolbong. Especially, according to an interview with a keeper, the visual perception frequency of the nightscape of Yowol-pavilion Garden is the highest when viewing by considering the east, the direction of Yellow-dragon River, as Suksigak[normal angle's view], towards Yowel-pavilion from the keeper's house. In addition, he said that the most beautiful landscape with high perception strength is when the moon came up from the left side of Yowol-pavilion, cuts across the Lagerstroemia india heal in front of Yowol-pavilion, and crosses the meridian between Mt. Wolbong peaks facing Yowol-pavilion. Currently, the exposure of Yowol-pavilion Garden is $SE\;141.2^{\circ}$, which is almost facing southeast. It is assumed that the exposure of Yowol-pavilion Garden was determined considering the optimized direction for appreciating the trace of the moon and the intention of securing the visibility as well as topographic conditions. Furthermore, it is presumed that the exposure of Yowol-pavilion Garden was determined so that the moon is reflected on the water of Yellow-dragon River and the moon and its reflection form a symmetry. Fourth, currently, Yowol-pavilion Garden is divided into 'inner garden sphere' composed of Yowol-pavilion, meeting place of the clan and administration building, and 'outer garden sphere' which is inclusive of entrance space, Crape Myrtle Community Garden and Pine Tree Forest in the back. Further, Yowol-pavilion Garden has been deteriorated as the edge was expanded to 'Small lake[Yong-so] and Gardens of aquatic plants sphere' and recently-created 'Yellow-dragon Pavilion and park sphere'. Fifth, at the time it was first made, Yowol-pavilion Garden was borderless gardens consisting of mountains and water taking a method of occupying a specific space of nearby nature centering around pavilion by embracing landscape viewed from the pavilion, but interpreted current complex landscapes are identified to be entirely different from landscapes of the original due to 'Different Changes', 'Fragmentation' and 'Apart piece' in many parts. Lastly, considering that Yowol-pavilion Garden belongs to the Cultural Properties Protection Zone, though not the restoration to the landscapes of the original described in tablet and literature record, at least taking a measure from the aspect of land use for minimizing adverse effect on landscape and visual damage is required.