• Title/Summary/Keyword: 개폐시간

Search Result 154, Processing Time 0.021 seconds

The Floor Layout Plan of Classrooms for Securing Evacuation Stability in School (학교의 피난 안전성 확보를 위한 층별 학급 배치방안)

  • Lee, Soon Beom;Lee, Jai Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.509-515
    • /
    • 2021
  • This study analyzes the efficient floor layout plan of classrooms for securing evacuation stability in school in case of fire by using the Pathfinder simulation program. Efficient evacuation methods and safety were evaluated by analyzing REST (Required Safe Egress Time) according to the allocation of personnel by floor targeting a high school 5-story building equipped with a ramp and stairs. The current status of personnel assignments exceeded the Required Safe Egress Time(RSET), resulting in a problem with evacuation safety. When students were placed on the 3rd, 4th, and 5th floors, the result was that the time exceeded RSET the most. When students were placed on the 1st, 2nd, and 3rd floors, the result was that they completed evacuation in the shortest time, less than RSET. In the current state, when evacuation was guided by designating an evacuation exit depending on the location, the result of shortening RSET was obtained. As a result, it is effective to put the students on the lower floors when placing students in high-rise school buildings in terms of evacuation safety, and in the preliminary training, it is required to designate evacuation exits so that they can use the nearest exit for each location in case of a fire. As a future research project, additional research is needed on the RSET when a fire occurs in a specific location according to whether the automatic fire door at that location is opened or closed.

Analysis of the Evacuation Safety with the Structure and Opening/Closing of Exits in a Fire at a Highway Service Area (고속도로 휴게소 화재 시 출입문의 구조와 개폐에 따른 피난안전성 분석)

  • Lee, Jai Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.419-425
    • /
    • 2021
  • This study analyzed the safety of evacuation according to the number of exits and the direction of evacuation routes with evacuation simulations of the Pathfinder in case of a fire at a highway service area. It was also analyzed of the difference in RSET by comparing the single or double types of the exit of a facility. The results were as follows. When only one direction exit was opened, all of the RSET were exceeded. When two or more different directions were opened according to the general principle of evacuation, all results met the RSET. The simulations showed that two or more different directions were more shortened in RSET than the one same direction. The result of the types of doors showed that the single type door was shortened in RSET rather than the double type doors. For the evacuation safety in a fire at the highway service areas, firstly, it is necessary to secure two or more exits in a fire at all times. Secondly, the exits should not be same directions. Finally, it is suggested that the exit should be installed with a single type of door.

Applicability Test of a Wetting and Drying Scheme for KU-RLMS Model (KU-RLMS 모형의 잠김-드러남 기법 적용성 평가)

  • Lee, Nam-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.448-457
    • /
    • 2011
  • A wetting and drying(WAD) scheme was introduced in KU-RLMS which is a two-dimensional depth-averaged unsteady model, and applicability tests for wetting and drying were performed in this study. WAD scheme in the model uses a mathematically less elegant but numerically easier method to test for dry or wet cells at each time step, then to apply blocking conditions for fluxes at cells' interfaces. WAD scheme introduced in the model was verified against an analytical solution in a frictionless parabolic basin. It was found that there occurs a little phase difference between analytical and numerical solution and little decrease of amplitude of numerical result. I used three test channels having a linear sloping bottom topography, a stepwise bottom topography, and a stepwise, a bumpy and bowl-shaped bottom topography. It could be found that numerical simulation results in test channels have similar shapes of Balzano[4] and Oey[15].

The Development of Remote Monitoring System for Storm Overflow Chamber Device (우수토실 일체형 하수유량조절장치 원격관리시스템 개발)

  • Jeon, In-Jae;Kim, Ki-Bong
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.61-68
    • /
    • 2018
  • This paper propose the remote monitoring system using LoRa networks about storm overflow chamber, which is a device designed to discharge rainwater directly to a sewage treatment plant when it reaches a certain amount of rainfall during precipitation. In this system, when the information produced by the sensor is transmitted to the LoRa network server and updated, the application server can automatically receive data through the implemented communication interface. The application server carries out management functions of storm overflow chamber devices and subscription information, collects measured flow rate and opening-closing information, and provides statistical information using the collected data. The android app performs a firebase-based notification function to prompt the user of malfunctioning of the storm overflow chamber device.

Development of electro hydraulic ballast remote valve control system with diagnostic function using redundant modbus communication (이중화 모드버스 통신을 이용한 퍼지기반 고장진단기능을 가진 선박 밸러스트 전기유압식 원격밸브제어시스템 개발)

  • Kim, Jong Hyun;Yu, Yung Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.292-301
    • /
    • 2014
  • This paper describes development of distributed type independent electro-hydraulic ballast valve remote control system with diagnostic function based on fuzzy inference using redundant Modbus communication and ethernet Modbus TCP/IP. Diagnostic function estimate degradation of system components and diagnose system faults, which results in shortage of fault maintenance time and improvement of system safety. Slave devices which control each valve and master device which command, monitor and diagnose slave system are developed. Slave devices are connected to master device with redundant Modbus networks and master device is connected to ship's integrated control system with Modbus TCP/IP. Also this paper describes development of simulator to test and confirm whether developed system can be integrated with ship's integrated control and monitoring system.

Analysis of operating characteristics and design review of oxidizer fill-drain valve (산화제 충전/배출 밸브의 설계 검토 및 작동 특성 분석)

  • Jang, Je-Sun;Kwon, Oh-Sung;Lee, Kyung-Won;Cho, In-Hyun
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.79-88
    • /
    • 2011
  • A fill-drain valve is operated by provided control gas at the ground for liquid propellant feeding system of space launch vehicle, which fills or drains on-board propellant tanks with a cryogenic oxidizer. We have analyzed and modified the data of fill-drain valve designed by Yuzhnoye. The simulation model of fill-drain valve is designed by using the AMESim code to predict and evaluate the dynamic characteristics and pneumatic behavior of valve. In this study, we performed a dynamic characteristic simulation on design parameter. And we could predict opening/closing time and pressures, operating performances on design parameters. This study will serve as one of reference guides to enhance the developmental efficiency of fill-drain valves with the various operating requirements, which shall be used in the Koreanized Space Launch Vehicle.

A Study on the Effect of Open and Closed Room Doors on Apartment Ventilation Characteristics (공동주택에서 각 실 문의 개폐에 따른 환기 특성 연구)

  • Choi, Im-Kyoo;Kim, Young-Il;Chung, Kwang-Seop
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.469-474
    • /
    • 2008
  • The objective of this study is to propose basic design guidelines for more effective air ventilation system in apartments. It is well known that ventilation depends on whether the room doors are open or closed as well as people's living patterns. This study considers 84 ㎡-sized apartment which has extended living room without balcony. Ventilation of bathroom and kitchen is not considered. The height of the building, external air pressure and air infiltration through the windows are also neglected. The regulation on indoor air quality made it mandatory that the air change per hour be more than 0.7. Four models are suggested to study the effect of open and closed doors. Models 1 and 3 are open door types and models 2 and 4 are closed door types. The open types have 50 mm hole near the top of the door to substitute exhaust outlet. The ventilation effectiveness was evaluated by 3-dimensional numerical simulation using finite volume method by a commercial software. This work compares air flow, temperature of air, age of air and the efficiency of ventilation of apartments with wooden doors of bedroom 1 and 2, which are open or closed.

  • PDF

Preparation and Characterization of Multilayer Microcapsules using Biocompatible Polymers (생체적합성 고분자를 사용한 다층 조립 구조 캡슐의 제조와 특성)

  • Jeon, Woohong;Kim, Gwang Yeon;Kim, Gue-Hyun;Ha, Chang-Sik
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.178-184
    • /
    • 2010
  • The aim of this work is the fabrication of polyelectrolyte microcapsules composed of biocompatible polymers such as chitosan, heparin and alginate, to encapsulate the fluorescein isothiocyanate(FITC)-albumin, and to investigate the protein release behavior therefrom. Polyelectrolyte capsules with 4-layer structures could be prepared with biocompatible materials by oppositely charged adsorption using melamin-foramide as a template. Transmission electron microscope(TEM), scanning electron microscope(SEM) and optical microscope confirmed hollow capsule structures. Protein release before and after encapsulation was monitored with a UV-Vis spectrometer. Microcapsules have different behaviors depending on the kind of polyelectrolyte polymers, chitosan-heparin capsules or chitosan-alginate capsules. In conclusion, the polyelectrolyte multilayer shells can be switched between an open and closed state by means of tuning the pH value.

A Study on Temperature Characteristics of Automatic Valve for High Pressure Cylinder of FCV (수소연료전지 자동차 압력 용기용 전자밸브의 온도 특성에 관한 연구)

  • Lee, Hyo-Ryeol;Ahn, Jung-Hwan;Kim, Hwa-Young;Kim, Young-Gu
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • FCV is installed with a automatic valve attached in an high pressure cylinder to control the hydrogen flow. The supply of hydrogen from the cylinder into the fuel cell stack is controlled via the on/off operation of a solenoid attached to the automatic valve. The solenoid needs to provide the necessary attraction force even at any saturation temperature caused by drive of the vehicle. In this study, the simplified prediction equations for the saturation temperature are suggested. The finite element analysis was performed by steady state technique, according to the boundary condition in order to predict the saturation temperature and attraction force. Finally, the saturation temperature was validated through comparison between the analysis results and measurement results. From the results, the measured saturation temperature $5.9^{\circ}C$ lower with respect to the analysis results. And the error of attraction force ranged from 1.0 to 2.1 N at testing conditions.

A Study on the Improvement of Voltage Measuring Method of 22.9 kV-y Distribution Lines (22.9 kV-y 배전선로의 전압계측방법 개선에 관한 연구)

  • Kil, Gyung-Suk;Song, Jae-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.293-299
    • /
    • 1998
  • An objective of this study is to develop a voltage measuring device that uses a gas-filled switch (GS) on 22.9 kV-y extra-high voltage distribution lines. The voltage measuring device proposed in this paper is a kind of capacitive divider which consists of a detecting electrode attached outside of the bushing of GS, an impedance matching circuit, and a voltage buffer. It can be easily installed in an established GS without changing the structure. For the calibration and application investigations, the voltage measuring device was set up in the 25.8 kV 400 A GS, and a step pulse generator having 5 ns rise time is used. As a result, it was found that the frequency bandwidth of the voltage measuring device ranges from 1.35 Hz to about 13 MHz. The error of voltage dividing ratio which is evaluated by the commercial frequency voltage of 60 Hz was less than 0.2%. In addition, voltage dividing ratio in the commercial frequency voltage and in a non-oscillating impulse voltage were compared, and their deviation were less than 0.7%.

  • PDF