• Title/Summary/Keyword: 개인건강기기

Search Result 107, Processing Time 0.037 seconds

Present Status and Analysis for IEEE 11073 Personal Health Device Specializations (IEEE 11073 개인건강기기별 표준 현황 및 분석)

  • Park, Han-Na;Kim, Seung-Hwan;Yoo, Done-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.469-475
    • /
    • 2012
  • Increasing interest of life expectancy and health has made the u-health industry activating and the several international standard developing organizations(SDO) are dealing with u-health services and technologies. Among them, IEEE 11073 PHD(Personal Health Devices) Work Group is developing standards of personal health device communication for interoperability. There are many studies for introducing SDOs and analyzing the IEEE 11073-20601 standard. However, due to the rare study of PHD standards analysis, there are a lot of difficulties to utilize the standards. In this paper, present status of national and international SDOs including IEEE 11073 standards for PHD will be introduced. Moreover, device specialization standards such as thermometer, weighing scale, glucose meter, blood pressure monitor, electrocardiograph (ECG) etc.. will be analyzed based on the IEEE 11073-20601.

Design of an Mobile Healthcare Manager for Interoperability (상호 운용성을 위한 모바일 헬스케어 매니저 설계)

  • Lee, Ku-Yeon;Park, Ju-Young;Lee, Chul-Ju;Kang, Kyung-Tae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.313-314
    • /
    • 2014
  • 인구의 고령화로 만성질환자가 증가함에 따라 개인건강관리를 위한 U 헬스 서비스에 관심이 증대되고 있다. U 헬스 서비스를 활용하기 위해서는 다양한 생체정보를 간편하게 측정하는 개인건강기기(PHD, Personal Health Device)가 필요하다. 하지만 혈압, 심전도, 혈당, 산소포화도 등을 측정하는 개인건강기기는 제작 회사마다 서로 다른 프로토콜과 포맷으로 개발되어 기기간의 상호 운용성(Interoperability)이 보장되지 않는다. 또한 각기 다른 포맷으로 측정된 데이터를 병원정보시스템(HIS, Hospital Information System)간 공유하고 관리하는데 어려움이 존재한다. 이에 따라, 본 논문에서는 개인건강기기 국제 표준인 IEEE 11073 PHD 를 기반으로 다양한 개인건강기기와 실시간으로 통신하며, 측정된 생체정보를 관리하고 전송하는 모바일 헬스케어 매니저 설계를 제시한다. 제시한 매니저는 다양한 모바일 기기 중 스마트폰 기반으로 설계하였고, 각기 다른 포맷으로 측정된 데이터를 국제표준 메시지 교환방식인 HL7 (Health Level Seven)메시지로 변환하여 전달하는 게이트웨이 역할을 담당한다.

Design of Smart TV-based Integrated Gateway Solution for Wellness Service (웰니스 서비스를 위한 스마트 TV 기반 통합 게이트웨이 솔루션 설계)

  • Kim, Jong-Pan;Heo, Sung-uk;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.950-953
    • /
    • 2013
  • 본 논문은 헬스케어 서비스에 대한 소비자 인식의 변화에 따라 최근 대두되고 있는 웰니스 서비스에 관한 연구이다. 현재 많은 소비자들이 여러 가지의 홈 헬스케어 개인건강기기를 통해 자신의 건강을 관리하고 있지만 제조사 별 고유의 소프트웨어와 통신 프로토콜을 내장되어있어 개인건강기기마다 각기 다른 방식의 서비스가 제공되고 있다. 이처럼 현재 제공되고 있는 헬스케어 서비스를 보다 효율적으로 제공하기 위해서는 다양한 개인건강기기와 서비스 제공 시스템간의 표준화된 인터페이스를 지원하기 위해서는 통합 게이트웨이 솔루션이 필요하다. 특히, 각 시스템 구성요소 간에 IEEE11073 PHD(Pelsonal Health Devices), HL7(Health Level Seven) 등의 표준을 통하여 건강정보 데이터 센싱, 취합 및 전송, 분석 및 피드백이 표준적인 방법으로 운용되어야한다. 이에 본 논문에서는 스마트 TV 환경에서 ISO/IEEE11073 표준을 준용하여 다양한 통신 인터페이스를 통한 개인건강기기의 연결성을 지원하는 통합 게이트웨이 솔루션 및 헬스케어, 건강관리와 관련된 서비스를 위한 건강정보 모니터링 앱을 설계하였다.

  • PDF

Development of an Ubiquitous Healthcare System based on Health Information Exchange Standards (건강정보 교환 표준에 기반한 유비쿼터스 헬스케어 시스템 개발)

  • Lee, In-Keun;Kim, Hwa-Sun;Cho, Hune
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.273-280
    • /
    • 2012
  • As changed the clinical environment, the interest on u-Healthcare service and systems has been increased. The ubiquitous healthcare(u-Healthcare) systems are constructed at the integrated environment that consists of various devices and systems basically such as personal health devices(PHDs) measuring body signals, information aggregators gathering the data transmitted from PHDs through wireless technology, and health information systems storing and managing personal health information transmitted from the information aggregators. International standards such as IEEE 11073 and HL7 have been specified for the interoperability of PHDs and health information systems, but the research on u-Healthcare systems that were developed and applied in the real clinical environment by adopting the standards was rarely conducted. Therefore, we developed an u-Healthcare system which can manage personal health information, such as blood glucose, blood pressure, and body composition, based on health information exchange standards. Moreover, we verified the stability of the developed system through clinical trial in patients with endocrine disease at the Kyungpook National University Hospital, and listed problems occurred during clinical trial and found their solutions.

Complexity Analysis for Implementation of the ISO/IEEE 11073 PHD Standards (ISO/IEEE 11073 PHD 표준 구현을 통한 복잡도 분석)

  • Kim, Sang-Kon;Yoo, Done-Sik;Kim, Tae-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.307-312
    • /
    • 2012
  • In this paper, we perform a complexity analysis for implementation of the ISO/IEEE 11073 Personal Health Device (PHD) standards in order to check the required system resources when ISO/IEEE 11073 PHD standards are implemented on the embedded system. Base on the implemented programs complying the PHD standards for a weighing scale, a blood pressure monitor, and a glucose meter among the various personal health devices, we make a pseudo-code. And then from the two different points of view such as program memory space and data memory space, we make a complexity analysis model. Because system resources or capability are strongly restricted in the personal health devices, our research work is very useful to estimate the required system resources.

A Study on the Interoperability of Home Healthcare System Based on Smart TV (스마트 TV 기반 홈 헬스케어 시스템의 상호운용성에 관한 연구)

  • Lim, Ji-yong;Heo, Sung-Uk;Oh, Am-Suk;Jeon, Jae-Hwan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.01a
    • /
    • pp.313-314
    • /
    • 2015
  • 홈 헬스케어 서비스를 위해서는 다양한 개인건강기기를 기반으로 사용자의 신체 상태를 측정하고 측정된 값을 적절하게 전송하는 시스템간의 통신과 인터페이스가 매우 중요한 요소이다. 그리고 개인 건강기기의 데이터를 이용한 상호운용성 확보를 위해서는 홈 헬스케어 의료기기와 홈 헬스케어 서버/게이트웨이 간의 ISO/IEEE 11073 표준을 만족해야 한다. 따라서, 본 논문에서는 스마트 TV환경 기반의 헬스케어 서비스를 제공하기 위해, 홈 헬스케어 시스템에서 Bluetooth HDP를 통해 개인 건강기기와의 IEEE 11073 표준 연결성에 대해 연구하였다.

  • PDF

ICT 융합 의료기기

  • Nam, Gi-Chang;Kim, Ho-Cheol;Gwon, Beom-Seon
    • Information and Communications Magazine
    • /
    • v.31 no.12
    • /
    • pp.44-50
    • /
    • 2014
  • 지난 수십년간 의료기기는 비약적인 발전을 거듭하며 의료서비스에 이바지하여 왔다. 최근의 기술동향으로는ICT(Information and Communication Technology) 기술의 발전이 전통적인 진단과 치료 방법에서 새로운 의료서비스의 형태로 진화를 유도하고 있다. ICT 기술과 의료기기의 융합을 통하여 진단, 치료, 의료정보화 및 개인건강관리 분야에 이르기 까지 신속하고 정확하고 효율적인 의료서비스 개선을 추구하고 있다. 인구의 고령화, 만성질환자 증가, 의료비상승, 의료진의 부족이 예상되는 미래환경에서 ICT 기술의 기여도는 점점 더 커질 것이다. 전세계적인 정보통신망 인프라의 활성화와 개인용 스마트 디바이스의 보급으로 정보와 기기에 대한 접근성이 훨씬 용이해지고 웰빙에 대한 관심이 높아지면서 개인 건강관리에 대한 서비스 요구가 높아지고 있다. ICT 종주국으로서 의료기기 산업에서도 국내기업의 활약을 기대하며 ICT 융합 의료기기의 현황을 소개하고자 한다.

Complexity Analysis for Implementation of the PM-store of ISO/IEEE 11073 PHD Standards (ISO/IEEE 11073 개인건강기기 표준의 PM-store 구현을 위한 복잡도 분석)

  • Kim, Sang-kon;Lee, Chang-ki;Kim, Tae-kon;Hwang, Hee-joung
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.447-454
    • /
    • 2015
  • In this paper, the complexity analysis for implementation of the PM-store is performed in terms of the number of instruction cycles which is executed by CPU in a personal health device(PHD) in order to transfer the large amount of the periodically generated measurement data using the PM-store concept defined in ISO/IEEE 11073 PHD standards. We propose an analytic model that is focused on the number of instruction cycles executed by CPU depending on the PM-store hierarchy.

Design of Smart TV-based Wellness Solution for Individual Health-care Service (개인건강관리를 위한 스마트TV 기반 웰니스 솔루션 설계)

  • Heo, Sung-Uk;Kang, Sung-In;Kim, Gwan-Hyung;Choi, Sung-Wook;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.865-866
    • /
    • 2013
  • 의학기술의 발전과 소득수준의 증가에 따라 사라들은 단순히 전염병을 예방하거나 질병을 치료하는 수준이 아닌 '건강하게 오래 사는 것'을 원하면서 치료에서 예방으로, 의료 공급자 중심에서 의료 소비자 중심으로 의료산업의 패러다임이 변화하고 있다. 이에 건강을 미리 지키는 예방적 개념의 웰니스 산업의 빠르게 성장하고 있다. 이에 본 논문에서는 Continua Health Alliance(CHA) 에서 개인건강기기에 반드시 포함해야 하는 표준인 ISO/IEEE 11073을 활용하고 Bluetooth HDP를 통해 의료기기와 스마트TV간 연결을 확보하고 지속적으로 개인의 건강을 체크할 수 있는 건강관리 모니터링 앱을 통한 일상생활 속에서의 건강관리를 위한 스마트TV를 기반의 웰니스 솔루션을 설계하였다.

  • PDF

Implementation of Integration Gateway Based on Smart TV Using IEEE 11073 (IEEE 11073을 활용한 스마트TV 기반의 통합 게이트웨이 구현)

  • Lim, Ji-yong;Heo, Sung-uk;Oh, Am-suk;Kim, Gwan-Hyung;Shin, Dong-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.645-647
    • /
    • 2014
  • 스마트 헬스케어는 최근 급속히 보급되고 있는 스마트기기를 바탕으로 복합적인 헬스케어 서비스를 제공하는 것으로 스마트 워크, 스마트 홈, 스마트 헬스와 같은 스마트 IT 패러다임을 스마트TV가 주도할 것으로 예상되면서 스마트 TV를 기반으로 하는 헬스케어 서비스가 주목받고 있으며 신뢰성 높은 서비스를 위한 스마트 TV와 개인건강기기 간의 상호 호환성이 중요한 요소로 작용되고 있다. 이에 본 논문에서는 스마트 TV의 환경에서 개인건강기기와의 신뢰성 있는 연결을 보장하기 위한 통합 게이트웨이를 구현하고자 한다.

  • PDF