• Title/Summary/Keyword: 개방 전압

Search Result 280, Processing Time 0.034 seconds

A Solar Energy Harvesting Circuit with Low-Cost MPPT Control for Low Duty-Cycled Sensor Nodes. (낮은 듀티 동작의 센서 노드를 위한 저비용 MPPT 제어기능을 갖는 빛에너지 하베스팅 회로)

  • Yoon, Eun-Jung;Yang, Min-Jae;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.397-400
    • /
    • 2015
  • In this paper a solar energy harvesting system with low-cost MPPT control for low duty-cycled sensor nodes is proposed. The targeted applications are environment, structure monitoring sensor nodes that are not required successively to operate, and MPPT(Maximum Power point Tracking) control using simple circuits is low-cost differently than existing MPPT control. The proposed MPPT control is implemented using linear relationship between the open-circuit voltage of a solar cell. The designed MPPT circuit traces the maximum power point by sampling periodically the open circuit voltage of the solar cell and delivers the maximum available power to the load. The proposed circuit is designed in 0.35um CMOS process. The designed chip area is $975um{\times}1025um$ including pads. Measured results show that the designed system can track the MPP voltage by sampling periodically the open circuit voltage of solar cell.

  • PDF

Time-Variant Characteristics of Organic Thin Film Solar Cell Devices on Plastic Substrates (플라스틱 기판에 제작된 유기박막태양전지의 출력특성 경시변화)

  • No, Im-Jun;Lee, Sunwoo;Shin, Paik-Kyun
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.4
    • /
    • pp.211-217
    • /
    • 2013
  • Two types of organic thin film solar cell devices with bulk hetero-junction (BHJ) structure were fabricated on plastic substrates using conjugated polymers of $PCDTBT:PC_{71}BM$ and $PTB7:PC_{71}BM$ blended as active channel layer. Time-variant characteristics of the organic thin film solar cell devices were investigated: short circuit current density ($J_{SC}$); open circuit voltage ($V_{OC}$); ; fill factor (FF); power conversion efficiency (PCE, ŋ). All the performance parameters were degraded by progress of the measurement time, while $V_{OC}$ showed the most drastic decrease with time. Possible factors to cause the time-variant alteration of performance parameters were discussed to be clarified.

Low Phase Noise VCO Using Microstrip Square Open Loop Resonator and Tunable Negative Resistance (Microstrip Square Open Loop와 Tunable Negative Resistance를 이용한 저위상 잡음 전압 제어 발진기)

  • Choi, Jae-Won;Lee, Chong-Min;Seo, Chul-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1143-1149
    • /
    • 2006
  • The microstrip square open loop resonator has been employed to reduce the phase noise in VCO. The microstrip square open loop resonator has the large coupling coefficient value, which makes a high Q value, and has reduced the phase noise of VCO. To increase the tuning range of VCO, varactor diode has been connected at the tunable negative resistance in VCO. The output power and harmonic characteristics of VCO has been obtained 4.83 dBm and -28.83 dBc, respectively. The phase noise of VCO has been $-112.33{\sim}-116.16dBc/Hz$ @ 100 kHz in the tuning range, $5.735{\sim}5.845GHz$.

A Study on the selection and noise test of elelctronic sensor for Vacuum Circuit Breaker (진공차단기용 전자식 센서의 선정 및 노이즈 시험에 관한 연구)

  • Lee, Ki Seon;Park, Jung Cheul;Chu, Soon Nam
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2503-2508
    • /
    • 2014
  • This study is about the selection and noise test of electronic sensor which is preceded by electric Operating Cell(EOC) development using electronic sensor technology to solve the structural weakness of Mechanism Operated Cell(MOC) in VCB, and has a final target in product development minimizing contact malfunction of the chattering or rebounce states caused by existing MOC. In this test results, when opening and closing VCB, rising velocity of surge voltage in opening time was measured 4.2 times faster than closing time and noise decibel value was measured respectively 120dB and 110dB. When supplying 60kV power frequency overvoltage, we found that sensor output graph in VCB opening and closing times operated stably without distortion. When supplying 150kV $1.2{\times}50{\mu}s$ impulse frequency voltage, we found that voltage graph of output contact in sensor opening and closing sides maintained a normal condition without distortion, and when supplying 2500A current, we found that tested result of electric field noise operated stably without distortion.

RECENT PROGRESS IN LARGE AREA AMORPHOUS SILICON SOLAR CELL MEDULES (대면적 비정질 실리콘 태양전지 모듈 개발연구)

  • 정현종;윤경식;김대원;배상순
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.161-166
    • /
    • 1996
  • 화학적 증착장치를 이용하여 크기 305mm$\times$915mm인 대면적 투명전도 유리기판 위에 비정질 실리콘 태양전지를 제작하였다. p층 제조 후 SiH4 세척과 수소 플라즈마 처리를 하여 I층에 도핑가스가 침투하는 것을 억제했으며 p-i 계면에 buffer층을 적용함으로써 소면적 단접합 태양전지에서 개발전압 0.825V, 충실도 0.73, 변환효율 9.5%인 셀을 제작하였다. 또한 a-Si/a-Si 이중접합 태양전지에서는 개방전압 1.50V, 충실도 0.77인 셀을 제작하였다.

  • PDF

Development of Automatic Fault Detection System for Chip-On-Film (칩 온 필름을 위한 자동 결함 검출 시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.2
    • /
    • pp.313-318
    • /
    • 2012
  • This paper presents an automatic system to detect variety of faults from fine pitch COF(chip-on-film) which is less than $30{\mu}m$. Developed system contains circuits and technique to detect fast various faults such as hard open, hard short, soft open and soft short from fine pattern. Basic principle for fault detection is to monitor fine differential voltage from pattern resistance differences between fault-free and faulty cases. The technique uses also radio frequency resonator arrays for easy detection to amplify fine differential voltage. We anticipate that proposed system is to be an alternative for conventional COF test systems since it can fast and accurately detect variety of faults from fine pattern COF test process.

Temporary Over Voltage Test System for Surge Protective Device in Low Distribution system (배전계통의 순간전압 상승에 따른 SPD 고압 TOV 시험설비 구축)

  • Kim, Young-Sung;Kim, Oun-Seok;Ahn, Gun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1391_1392
    • /
    • 2009
  • 본 논문에서는 저압 서지보호기의 안전성평가를 위한 고압 계통 고장에 의한 순간 과전압시험 설비를 IEC 61643-1의 따라 구축 하였고, 구축된 시험설비의 성능을 분석하였다. 고압 계통의 순간 과전압시험 기준은 가장 일반적인 미국전력 계통의 기준인 3상 4선식이 반영이 되었으며 전압의 크기는 AC 1200V이다. 본 논문에서는 순간과전압이 상과 접지사이의 개방전압 AC 1200V을 약 200ms 동안 인가되는지를 측정하였고, 단락전류가 AC 300A이상을 측정하였다.

  • PDF

An Application Result of the Power-Quality Price Evaluation Method Considering Voltage Characteristic of Load (부하의 전압특성을 고려한 전력품질 가격산정 기법의 모의계통 응용)

  • Lee, Geun-Joon;Kang, Ku-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.325-327
    • /
    • 2005
  • 전력시장의 본격적인 개방을 앞두고 전력품질의 평가와 적정한 가격의 반영 매커니즘은 고도한 산업구조를 뒷받침하면서 전력시스템에 대한 투자 활성화를 위해 꼭 필요한 것이다. 본 연구에서는 부하의 전압이 변동할 때 부하가 허용할 수 있는 전압의 특성을 나타낸 전력 허용성 곡선(CBEMA)을 이용하여 모선 부하들에 대한 전력품질을 지표화 하는 한편, 이를 가격으로 환산하는 방법을 제안한다. 본 연구의 장점은 각 모선에 설치된 부하의 종류 및 구성비를 기초로 부하모형을 산출하고 모선에 대표가 되는 전력품질곡선을 작성하므로, 각 모선별 전력품질 지표 및 비용의 산출이 가능하며, 이를 기초로 전력계통 문제해석시 품질비용의 취급이 가능하다는 점이다. 본 논문은 부하-전압특성을 전력허용 곡선에 의해 도출하고 각 모선별 대표 전력허용곡선을 산출한 다음 이를 모형계통에 적용함으로써 전력품질가격산정기법의 적용을 가능케하였다.

  • PDF

Hysteretic Variable Structure Controller for PV Simulator (PV Simulator를 위한 히스테리시스 가변구조 제어기)

  • Na, Jaeho;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.263-264
    • /
    • 2015
  • 태양광 발전용 PCS(Power Conditioning System)의 성능을 평가를 위해 사용되는 PV Simulator는 전압제어방식 또는 전류제어방식으로 제어할 수 있다. 각각의 제어방식을 개별적으로 개방전압 운전점에서 단락전류 운전점까지 부하를 가변 하였을 때 서로 상반된 구간에서 불안정한 구간이 발생한 것을 실험을 통해 발견하였다. 이렇게 불안정한 제어 구간에서는 PV Simulator의 출력 전압과 전류가 심하게 바운싱되기 때문에 전 운전 범위에서 PCS의 성능평가를 하는데 제한이 있을 뿐만 아니라, 하드웨어에도 손상을 줄 수 있다. 본 논문은 전압제어방식과 전류제어방식이 각각 안정한 제어 구간에서 불안정한 제어 구간으로 이동되기 전에 히스테리시스 가변 구조로 제어함으로써 두 제어방식의 장점을 극대화 시킨 PV Simulator 제어기를 제안한다.

  • PDF

Study of Fault Tolerant and Circulating Current Control Method for Three-Phase 2-Parallel PWM Converter Systems (3상 2-병렬 PWM 컨버터의 고장허용 제어 및 순환전류 저감에 관한 연구)

  • Park, Jin-Woo;Jung, Jun-Hyung;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.58-59
    • /
    • 2016
  • 본 논문에서는 3상 2-병렬 PWM 컨버터의 단일 스위치 개방 고장 시 고장 허용 제어 방법과 그에 따라 발생하는 순환전류를 저감하는 연구를 진행 하였다. PWM 컨버터의 스위치 개방 고장은 DC단 전압 맥동과 계통 측 전류의 왜곡을 유발하며 이는 고장허용제어를 통해 개선 가능하다. 하지만 고장허용제어를 병렬형 PWM 컨버터에 적용하는 경우에는 컨버터의 비동기적인 스위칭으로 발생된 순환 전류 때문에 기존의 방법을 적용 할 수 없다. 따라서 본 논문에서는 2-병렬 PWM 컨버터의 스위치 개방 고장 허용제어에 따른 순환전류 저감에 대한 연구를 진행하였다. 연구한 내용은 시뮬레이션을 통해 확인하였다.

  • PDF