• Title/Summary/Keyword: 개방형고장

Search Result 31, Processing Time 0.031 seconds

Fault Diagnosis Scheme for Open-Phase Fault of Permanent Magnet Synchronous Motor Drive using Extended Kalman Filter (영구자석 동기전동기 드라이브의 확장형 칼만필터를 이용한 개방성 고장진단 기법)

  • Ahn, Sung-Guk;Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.191-198
    • /
    • 2011
  • In this paper, the fault diagnosis scheme for PMSM drives has been proposed to maintain control performance under a switch open-phase fault of inverter. When the open-phase fault occurs, the stator resistances of PMSM are estimated by Extended Kalman Filter (EKF) in real time and can appear differently according to the location of fault occurrence to check the fault detection and identification. The control algorithm is configured without the additional device and low cost by adding the existing control program. Also, by using motor parameter the estimated stator resistance value improves the control performance of the controller affected by parameter variation. The feasibility of the proposed fault diagnosis algorithm is validated in simulation and experiment.

Detection Method of an Open Circuit Fault in a Grid Connected NPC Inverter System (계통연계 형 NPC인버터 시스템의 개방성 고장진단)

  • Jang, Dae-Min;Choi, Ui-Min;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.417-418
    • /
    • 2011
  • 본 논문은 계통연계 형 3-레벨 NPC(Neutral Point Clamped)인버터의 고장진단 방법을 제안한다. 제안하는 고장진단 방법은 스위칭 소자의 개방고장 진단뿐만 아니라 고장 난 스위칭 소자의 위치 또한 판별 할 수 있다. 스위칭 소자의 고장 진단은 콘코디아 변환(Concordia transformation)에 의한 전류패턴의 반지름 변화로 판단 할 수 있다. 고장 난 스위칭 소자의 위치는 기존의 콘코디아 변환(Concordia transformation)에 의한 전류패턴을 분석하는 방법에 간단한 스위칭 동작을 추가함으로써 구분 할 수 있다. 제안하는 기법은 추가적인 센서가 필요하지 않고 전류신호에 기반을 두고 있으므로 시스템의 복잡한 모델링이 필요하지 않은 장점이 있다. 본 논문은 10kW급 태양광 계통연계 시스템을 모의한 시뮬레이션을 바탕으로 제안한 기법의 타당성을 검증한다.

  • PDF

Study of Fault Tolerant and Circulating Current Control Method for Three-Phase 2-Parallel PWM Converter Systems (3상 2-병렬 PWM 컨버터의 고장허용 제어 및 순환전류 저감에 관한 연구)

  • Park, Jin-Woo;Jung, Jun-Hyung;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.58-59
    • /
    • 2016
  • 본 논문에서는 3상 2-병렬 PWM 컨버터의 단일 스위치 개방 고장 시 고장 허용 제어 방법과 그에 따라 발생하는 순환전류를 저감하는 연구를 진행 하였다. PWM 컨버터의 스위치 개방 고장은 DC단 전압 맥동과 계통 측 전류의 왜곡을 유발하며 이는 고장허용제어를 통해 개선 가능하다. 하지만 고장허용제어를 병렬형 PWM 컨버터에 적용하는 경우에는 컨버터의 비동기적인 스위칭으로 발생된 순환 전류 때문에 기존의 방법을 적용 할 수 없다. 따라서 본 논문에서는 2-병렬 PWM 컨버터의 스위치 개방 고장 허용제어에 따른 순환전류 저감에 대한 연구를 진행하였다. 연구한 내용은 시뮬레이션을 통해 확인하였다.

  • PDF

Fault Detection and Compensation Scheme of Switch Open-fault in VSI for Two-phase Excitation Drive (2상 여자 구동용 전압형 인버터의 스위치 개방고장 검출 및 보상 기법)

  • Lee, Kui-Jun;Park, Nam-Ju;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.74-80
    • /
    • 2007
  • This paper proposes the novel open-fault detection/isolation scheme of inverter switch in two-phase excited VSI. This scheme identify open-fault using voltage sensor at lower switches of each phase according to the operating mode. It has benefit of simple implementation, fast detection and robustness in the load so that stab of the system is improved. Also, at faulty mode, it minimizes faulty effect and makes possible continuous operation through the reconfiguration procedure applying four-switch operation. The validity of proposed fault detection scheme is verified by experimental results.

Fault Diagnosis of DC-DC Boost Converter (DC-DC 부스트 컨버터 고장 진단 알고리즘)

  • Cho, Hyun-ki;Kwak, Sang-shin
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.123-124
    • /
    • 2012
  • 최근, 높은 신뢰성을 갖는 전원공급 시스템의 중요성이 부각되면서 컨버터 내 고장을 빠르게 진단할 수 있는 기능이 필요하게 되었다. 본 논문은 DC-DC 부스트 컨버터 스위치의 개방형 고장 및 단락형 고장 발생 시, 인덕터의 전압을 통해 고장 여부를 검출하는 동시에 고장 종류를 진단할 수 있는 알고리즘을 제안한다.

  • PDF

A Survey on Fault Detection and Diagnosis Method for Open-Cycle Liquid Rocket Engines through China R&D Case (중국의 연구 사례를 통한 개방형 액체로켓엔진의 고장진단 동향 분석)

  • Lee, Kyelim;Cha, Jihyoung;Ko, Sangho
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.3
    • /
    • pp.22-30
    • /
    • 2017
  • This paper examines a survey on recent research regarding health monitoring and management for liquid rocket engines (LRE). For this, we investigated precedent techniques applied to LRE development. Particularly, we focused on open-cycle LRE to apply to KSLV-II (Korea Space Launch Vehicle II). Through this study, we subdivided health monitoring algorithms and analyzed fault detection and diagnosis algorithm developed in China, since China researched open-cycle LRE that have the same cycle as KSLV-II rocket engines. We discuss significant points to be considered regarding development of the KSLV-II.

A Novel Fault Detection Method using the PWM characteristic at Open-Circuit Fault in NPC Inverter Systems (NPC 인버터 시스템에서 개방성 고장시 PWM 특성을 이용한 새로운 고장 검출 방법)

  • Kim, Tae-Jin;Lee, Jung-Dae;Ha, Dong-Hyun;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.900-901
    • /
    • 2008
  • 본 논문은 NPC 인버터(Neutral-point-clamped Inverter) 시스템을 구성하는 스위칭 소자에 개방성 고장이 발생하였을 경우 인버터 시스템의 고장 검출을 위한 새로운 고장 검출 방법을 제안하였다. 이 방법은 CPWM(continuous-PWM) 고유의 특성을 이용하기 때문에 간단한 알고리즘으로서 구현이 용이할 뿐만 아니라 기존의 방법보다 빠른 고장 검출 능력을 가진다. 빠른 고장 검출 능력은 고장 검출 시간의 지연에서 올 수 있는 직류-링크 커패시터의 전압 불평형 문제 및 이로 인한 다른 스위치로의 전압 스트레스 증가에 의한 소자 파괴와 같은 악영향을 개선시킬 수 있다. 제안된 방법의 타당성을 입증하기 위하여 실험을 수행하였다.

  • PDF

A Study on Fault Model end Performance Evaluation under Power Switch Open Fault in an Inverter-Driven Permanent Magnets Synchronous Motor (영구자석 동기전동기 구동 인버터 스위치의 개방 고장에 의한 제어 특성해석 및 고장모델 연구)

  • Kim, Kyeong-Hwa;Choi, Dong-Uk;Gu, Bon-Gwan;Jung, In-Soung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.40-51
    • /
    • 2009
  • To analyze influences under open faults in switching devices of the PWM inverter and under the isolation between the inverter and motor terminal, a faulty model for the inverter-driven permanent magnet synchronous motor is presented. Even though the conventional dq motor model obtained through the transformation of phase voltage model is widely used to analyze and control AC motor, it can not be used under open faults in switching devices since the 3-phase balanced condition is no longer hold under the open fault and it is not easy to obtain motor input voltages in open phase from the pole voltage. To deal with this problem, a faulty model for an inverter-driven permanent magnet synchronous motor is derived by using the line voltage of motor according to switch open, which can be effectively used for performance evaluation of the diagnostic algorithm. The validity of the proposed faulty model is verified through comparative simulations and experiments using DSP TMS320F28335.

Fault diagnostic method for multiple open-switch faults in an inverter-fed linear induction motor (선형 유도 전동기 구동 인버터의 다중 스위치 개방형 고장 진단 기법)

  • Choi, Jung-Hyun;Kim, Kyeong-Hwa;Kim, Sanghoon;Yoo, Dong sang
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.518-519
    • /
    • 2014
  • 선형 유도 전동기 구동 인버터의 스위치 결함에 대한 신뢰성 향상을 위해, 실제 온라인 기반의 고장 및 고장점 검출에 대한 연구가 활발하다. 인버터에서 스위치 고장이 발생하면, 일반적으로 전압, 전류에 고조파가 발생되고 토크의 리플이 증가하게 된다. 또한, 인버터 스위치 고장의 경우 과전류가 발생하며 다른 전자 부품에 2차 피해를 일으킬 수 있다. 본 논문에서는 센서를 통해 얻은 전류의 정보를 이용하여 고장 및 고장 스위치를 검출하는 알고리즘을 제안한다. 한 개 또는 두 개의 스위치 고장을 4개의 faulty group으로 구별하여 고장 검출이 이루어지며 제안된 알고리즘을 입증하기 위해 Matlab-Simulink을 이용한 시뮬레이션 결과와 실험 결과가 제시된다.

  • PDF

A Novel Fault Detection Method of Open-Fault in NPC Inverter System (NPC 인버터의 개방성 고장에 대한 새로운 고장 검출 방법)

  • Lee, Jae-Chul;Kim, Tae-Jin;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.115-122
    • /
    • 2007
  • In this paper, a novel fault detection method for fault tolerant control is proposed when the NPC inverter has a open failure in the switching device. The open fault of switching device is detected by checking the variation of a leg-voltage in the neutral-point-clamped inverter and the two phases control method is used for continuously balance the three phases voltage to the load. It can be achieve the fault tolerant control for improving the reliability of the NPC inverter by the fault detection and reconfiguration. This method has fast detection ability and a simple realization for fault detection, compared with a conventional method. Also, this fast detection ability improved the harmful effects such as DC-link voltage unbalance and overstress to other switching devices from a delay of fault detection. The proposed method has been verified by simulation and experiment.