• Title/Summary/Keyword: 개발용량

Search Result 1,978, Processing Time 0.032 seconds

Development of Model Based Battery SOC Indicator for Electric Vehicle (모델기반의 전기자동차용 전지 잔존용량계 개발)

  • Lim, Y.C.;Park, J.G.;Ryoo, Y,J.;Lee, H.S.;Byun, S.C.;Kim, E.S.
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.35-42
    • /
    • 1996
  • In this paper, a development of model based battery SOC indicator is described. The proposed method is independent upon initial SOC, is reliable on the sudden change of load, and could estimate the available driving distance. The mathematical model of battery which has relation of the current, voltage and SOC estimates the SOC by least square estimation to minimize the error between measured voltage and estimated voltage. For experiment, the charging and discharging system using computer was designed to acquire the current and voltage data for model. The feasibility in electric vehicle was confirmed by variable load testing using the developed SOC indicator by stand-alone type microcontroller.

  • PDF

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (지열원 멀티열펌프 시스템의 용량가변 특성 연구)

  • Cho, Chanyong;Oh, Myung Suk;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF

고속 백플랜 기술: 광 백플랜

  • 박효훈;안승호
    • The Magazine of the IEIE
    • /
    • v.31 no.8
    • /
    • pp.61-72
    • /
    • 2004
  • 통신시스템의 클락 속도는 수 GHz를 넘어 10GHz수준을 요구하고 있고, 입출력 단자에서 전송용량은 수백 Gb/s를 넘어 수 Tb/s 이상을 요구하고 있다. 이처럼 급증하는 속도와 용량을 백플랜에서 감당하게 되어, 백플랜이 시스템 성능을 좌우하는 주요부분으로 되어있다. 기존의 전기적 배선에 의한 백플랜 구성은 더 이상의 속도와 용량을 감당하기에 힘들게 되어,[1] 신호전송을 전자 대신 빛으로 하는 광 백플랜이 그 대안으로 개발되고 있다.(중략)

  • PDF

패류양식해역 환경용량 산정 II 고성만 환경용량 산정

  • 이원찬;최우정;이필용;김형철;구준호;박청길
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.10a
    • /
    • pp.210-211
    • /
    • 2001
  • 연안 해역은 어장환경 악화와 가용 먹이량을 초과한 시설량 증대로 양식 생물의 생존 및 성장률이 저하되어 생산량이 감소하고 있으며 (Keng et ai.,2000; Sugawara & Okoshi, 1991), 부영양화가 진행적지 않은 일부 해역에서도 양식 생물의 미성숙으로 인해 양식 기간이 연장되고 있다 (Choi et al., 1997). 이와 같은 이유로 양식 어장의 지속적인 개발과 이용을 위해서는 해역의 환경용량 (Carrying capacity)에 적합하도록 양식 생물 시설량을 재 조정할 필요성이 제기되고 있다 (Heral et al., 1990; Kang et al., 2000) (중략)

  • PDF

Estimating Development Density Constrained by Traffic Congestion in the Downtown, Seoul (교통혼잡을 고려한 서울 도심부 개발가능밀도 추정)

  • Hwang, Kee Yeon;Shin, Sang Young;Kang, Jun Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1D
    • /
    • pp.49-58
    • /
    • 2006
  • The purpose of this study is to develop transportation-sensitive land use densities in a metropolitan context. It analyses traffic impacts according to 20 different development density scenarios in the downtown Seoul, and estimates the density ceiling. The results identify that the transportation-wise sustainable density in the downtown can be extended up to the FAR level of 460% with an option of 2,000 won congestion charge levied on the downtown area. It also finds that the region-wide sustainability measured by congestion level can be improving as the level of congestion charge increases. Without the congestion charge, however, the density ceiling slides down to 430%. It is recommended that, in order to bring in higher density developments in the region, transportation demand management (TDM) measures are indispensible.

해외전력 - 멕시코전력공사의 전원개발계획 (2017년까지 2,649만 kW의 증강을 계획)

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.387
    • /
    • pp.68-69
    • /
    • 2009
  • 국유전기사업자 멕시코전력공사(CFE)는 2008년 9월, 앞으로 10년간의 전원개발계획을 종합 정리한 보고서 "Programs de Obrase Inversions de Sector Electrico 2008-2017"을 발표하였다. CFE는 2017년까지의 전력수요의 신장을 연평균 4.8%로 예상하여 발전설비를 약 2,649만 kW 증강하는 계획이다. 이 계획에서는 신규 전원의 주력을 가스 컴바인드 사이클로 하고 있으나 재생가능에너지 전원을 총발전용량의 25%로 하는 것과 석유 등의 발전화력을 단계적으로 폐지하는 것 등도 포함시키고 있다. 다만 신규 발전소의 건설은 독립발전사업자(IPP)에 의지하지 않을 수 없는 상황으로 계획목표 중에 679만 kW 상당의 용량은 미확정 상태로 두고 있다.

  • PDF

Investigation on the modified continual reassessment method in phase I clinical trial (1상 임상실험에서 수정된 CRM에 대한 연구)

  • 강승호
    • The Korean Journal of Applied Statistics
    • /
    • v.15 no.2
    • /
    • pp.323-336
    • /
    • 2002
  • In this paper we consider the modified continual reassessment method in which a cohort consists of three patients. Simulation has been a main research tool in the investigation of CRM. In this paper we propose complete enumeration as an alternative of simulation. Using new method we show that the expected toxicity rate at the MTD converges to the target toxicity rate well as the sample size increases.

A Method to Select Optimal Size of Multiple Distributed Generation System by Using the Reduced Multivariate Polynomial Model (RMP 기법을 사용한 복수 분산전원 시스템의 용량선정 최적화 방법)

  • Lee, Soo-Hyoung;Park, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.56_57
    • /
    • 2009
  • 전력설비의 증설 없이 지속적으로 증가하는 부하는 전력계통의 안정성 및 신뢰성 확보를 어렵게 하며, 송전으로 인한 전력손실을 급격하게 증가시킨다. 비용 및 환경적인 측면에서, 분산전원은 야기되는 문제의 해결책이 될 수 있으며, 분산전원의 연계로 얻어지는 전력계통의 안정도 및 신뢰도 향상과 전력손실 감소는 연계되는 분산전원의 용량에 의해 결정이 된다. 따라서 최적용량 선정문제는 분산전원을 전력계통에 연계하기 위해 필수적으로 선행되어야 할 과제이나, 현재까지 이를 명확하게 해결한 체계적 방법은 개발되지 않았다. 이번 연구는 reduced multivariate polynomial (RMP)모델을 이용한 계통연계 복수 분산전원 시스템의 최적용량 선정 방법을 제안하며, 최적용량 선정을 위해 요구되는 시스템 자원을 획기적으로 감소시킨다.

  • PDF

A Study on Iron Electrode of Ni/Fe Battery(II) (니켈/철 축전지의 철전극에 관한 연구(II))

  • 김운석;박성용;조원일;조병원;윤경석
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.300-307
    • /
    • 1993
  • To develop high performance nickel-iron secondary battery, the characteristics of charge-discharge reaction of iron electrode were examined by cyclic voltammetry technique, SEM and XRD analysis. The capacity of the test electrodes was determined by the constant current charge-discharge method. It was found that the temperature and concentration of electrolyte were the major determinant factors of electrode capacity, and especially the 1st discharge capacity was increased with the increase of temperature. The effect of fore forming agent on the electrode capacity was negligible. The electrode capacity was above 350 ㎃h/g(36% utility) at 0.25C discharge rate. The stability of electrode was very good, but the activation occurred slowly.

  • PDF

Preparation and Characterization of Si-loaded Expanded Graphite as Anode Material for Lithium ion Batteries (실리콘이 함유된 팽창흑연의 제조 및 전기화학적 특성)

  • Kim, Eunkyung;Ji, Mijung;Jung, Sunghun;Choi, Byunghyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.103.2-103.2
    • /
    • 2011
  • 리튬이차전지의 음극물질로서 상용화되고 있는 탄소재료중 흑연은 전기자동차에 적용하기에는 낮은 용량과 나쁜 출력특성을 갖고 있어 지금보다 두배이상의 용량과 출력특성이 좋은 음극소재의 개발이 필요하다. 또 다른 음극물질로 실리콘은 흑연에 비해 월등히 높은 이론용량을 나타내고 있지만 실리콘이 리튬이온과 만나면 부피가 4배이상 팽창하여 사이클이 진행될수록 충방전 용량이 급격히 감소하게 된다. 그래서 본 연구에서는 이 두 음극소재를 상호보완하기 위해 천연흑연을 산처리 과정을 통해 제조된 팽창흑연을 매트릭스로 사용하여 팽창흑연에 실리콘을 충진 시키는 연구를 진행하였다. 팽창흑연에 실리콘을 충진시킴으로써 1C일 때 약 650mAh/g의 용량을 나타내었으며, 50cycle이 진행된 후에도 비교적 안정한 사이클 특성을 나타내었다.

  • PDF