• 제목/요약/키워드: 개구 크기

Search Result 210, Processing Time 0.037 seconds

Estimation of optical losses in dielectric apertured terahertz vertical cavity lasers (개구 크기에 따른 테라헤르츠 표면 발광 반도체 레이저의 광손실에 대한 연구)

  • 유영훈
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.92-96
    • /
    • 2003
  • Dielectric apertures in vertical cavity laser have been used for improved device performance. Numerical analysis is used to estimate the optical losses as the aperture diameter is reduced. The optical losses depend on the aperture size, thickness and location. The optical loss strongly depend on the aperture size and thickness when the aperture size is similar or smaller than the emitted wavelength. The optical loss is negligible and not depend on the aperture thickness when the aperture size is larger than 5 times emitted wavelength.

ELECTROMAGNETIC RADIATION CHARACTERISTICS Of SLIM TYPE DOUBLE CAVITY BY INTERNAL ELECTROMAGNETIC SOURCES (내부 전자파원에 의한 슬림형 이중 공동의 전자파 방사 특성)

  • Park, Eun-Jung;Kim, Kyeong-Bong;Kim, Ki-Chai;Kim, Eee-Kook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.217-220
    • /
    • 2007
  • 본 논문에서는 이중 구조의 공동에서 작은 공동 내부에 존재하는 전자파원으로부터 방사되는 전자파를 내부 공동의 개구를 지나 외부 공동의 개구를 통해 방사될 때, 외부 공동의 개구 크기 변화에 따른 방사 전자파의 크기를 FDTD법으로 검토하고 있다. 외부 공동 개구의 크기는 최대 방사 전자파의 주파수를 결정하므로 개구의 크기를 조절하면 방사되는 전자파의 크기를 제어할 수 있음을 이론해석을 통하여 확인하고 있다.

  • PDF

Reduction of Electromagnetic Penetration Through Narrow Slots in Conducting Screens (도체평판의 슬롯을 통하여 침입하는 침투전자파의 저감)

  • 김기채;김민석
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.12-15
    • /
    • 2001
  • 본 논문에서는 무한 도체판에 존재하는 폭이 좁은 슬롯에 단락도체를 설치하였을 때 슬롯을 통하여 침투하는 침투전자파의 크기를 검토하고 있다. 이론해석으로서는 슬롯 개구면의 전계분포에 관한 적분방정식을 유도하고, 개구면 전계분포를 등가 반경의 개념을 적용한 선자류로 가정하여 구분정현함수를 사용한 Galerkin의 모멘트법으로 침투전자파의 크기를 계산하였다. 슬롯에 평면파가 입사할 때 슬롯 개구에 설치된 단락도체에 의해 개구면 전계분포가 제어되고 침투전자파의 크기가 감소된다는 것을 확인하고 있다.

  • PDF

Fire Simulation for Vent Flow and Temperature in Engine Room of Small Ship: Effects of Ceiling Duct Location and Side Vent Size (소형선박 기관실의 개구부 유동 및 온도에 대한 화재시뮬레이션: 천장 통풍통 위치 및 측면 개구부 크기 영향)

  • Jeong, Lee-Gyu;Lee, Chi Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.454-465
    • /
    • 2020
  • Fire simulations were performed using the Fire Dynamics Simulator (FDS) software to examine the vent flow and temperature in the engine room of a small ship. A diesel fire with a heat release rate of 10 kW was targeted, and the effects of the ceiling duct location, side vent existence and nonexistence, and side vent size were investigated. The existence or nonexistence of the side vent and its size considerably affected the smoke behavior, mass flow rate through the vent, and temperature. When the side vent was not installed or was small, the smoke layer reached the floor in the engine room. In addition, as the side vent size increased, the mass flow rate through the vent increased with decreasing temperature value. However, the effects of the ceiling duct location on the smoke behavior, mass flow rate through the vent, and temperature seemed to be relatively minor compared to those of the side vent size. Therefore, to improve the fire safety of the engine room in a small ship, the side vent size is considered to be a more important design factor than the ceiling duct location.

A Study on the External Wall Heating Temperature Distribution According to Opening Size in Building (건물의 개구부 크기에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.261-267
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as following: when the experiment was conducted with opening sizes(horizontal length) each at 2,000mm, 1,600mm, and 1,400mm, the flashover occurred at 630 seconds, 505 seconds and 510 seconds, respectively. Also, the total heating time, in proportion to this, came to 815 seconds, 713 seconds and 721 seconds. The maximum heating temperature of the exterior wall by the opening size reached 282.4℃ at 2,000mm, 382.9℃ at 1,600mm, and 423.8℃ at 1,400mm. This represented that as the opening size gets smaller, the heating temperature of the exterior wall by fire spread becomes higher.

Characteristics of Insertion Loss of Transmission Line with Equal Line Length Due to a Rectangular Aperture Size in a Backplane (백플레인 개구의 크기 변화에 따른 대칭 전송선로의 삽입 손실)

  • Jung, Sung-Woo;Cho, Jun-Ho;Kim, Ki-Chai
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2518-2524
    • /
    • 2009
  • This paper presents the backplane effects due to a rectangular aperture size for two-wire transmission line with equal line length crossing the changeable rectangular aperture in an infinite ground backplane. It is used to determine the characteristics of the backplane insertion loss of the transmission line from the load section in accordance with the backplane aperture size. The results show that the insertion gain and insertion loss are obtained for the specific frequency range when the transmission line is closed to the backplane aperture size. The insertion loss is decreased that the aperture horizontal length and vertical length is more than a=50 mm and b=20 mm. The measurements of insertion loss are performed to verify the theoretical analysis.

RADIATED EMISSION CHARACTERISTICS OF DOUBLE CAVITY BY INNER CAVITY AND EXTERNAL SLOT LOCATIONS (이중 공동의 전원단 위치와 외부공동의 개구 위치변화에 따른 전자파 방사특성)

  • Park, Eun-Jung;Park, Jae-Wook;Kim, Geun-Soo;Kim, Ki-Chai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.339-342
    • /
    • 2008
  • 본 논문에서는 이중 구조의 공동에서 작은 공동 전원단 내부에 존재하는 전자파원으로부터 방사되는 전자파를 내부 전원단의 개구를 지나 외부 공동의 개구를 통해 방사될 때, 내부 전원단의 위치와 외부 공동의 개구 위치 변화에 따른 방사 전자파의 크기를 FDTD법으로 검토하고 있다. 외부 공동 개구의 크기는 최대 방사 전자파의 주파수를 결정하며 내부 전원단의 위치를 조절하면 방사되는 전자파의 크기를 제어할 수 있음을 이론해석으로 통하여 확인하고 있다.

  • PDF

Compartment Fire Test Using Kerosene and Aviation Fuel (등유 및 항공유를 사용한 격실 화재시험)

  • Bang, Kyoung-Sik;Lee, Ju-Chan;Seo, Chung-Seok;Seo, Ki-Seog;Kim, Hyung-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.476-479
    • /
    • 2012
  • 차량의 충돌에 따른 등유의 누출에 의한 화재와 항공기 충돌에 따른 항공유의 누출에 의한 화재 발생 시 격실의 개구부 크기에 따른 화염온도를 평가하기 위해 화원으로 등유와 Jet-A-1을 사용하고 개구부의 크기를 조절해 가며 격실화재시험을 수행하였으며, 가장 높게 측정된 시험결과의 조건으로 과도화재시험을 수행하여 금속저장용기가 화염온도에 미치는 영향을 평가하였다. 시험결과 등유보다 Jet-A-1의 열 방출속도 및 질량 연소유속이 크게 나타났으며, Jet-A-1에서의 화염온도가 높게 측정되었다. 연료 소모율은 개구부의 크기가 클 경우 작은 경우보다 크게 나타났으며, 개구부의 크기가 클 경우 화염온도가 높게 측정되었다. 격실 내에 금속저장용기가 저장되었을 때는 저장용기가 화염으로부터 받는 열량만큼 화염의 온도는 낮아지는 것으로 나타났다.

  • PDF

Reduction Characteristics of Electromagnetic Penetration Through Narrow Slots by Resistive Sheet Loading (손실판 장하에 의한 슬릿 침투 전자파의 저감 특성)

  • Cho, Jun-Ho;Park, Eun-Jung;Kim, Kyeong-Bong;Jung, Sung-Woo;Kim, Ki-Chai
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1518-1519
    • /
    • 2007
  • 본 논문에서는 두 개의 무한도체 평판에 폭이 좁은 개구가 존재할 때, 개구를 통해서 침투하는 침투전자파의 크기를 두 무한도체 평판사이에 여러 가지 특성을 가지는 손실판을 장하하여 개구면 전계분포를 제어하여 침투 전자파의 크기를 저감시키는 방법을 제안하고 있다. 개구면에 평면파가 입사할 때, 손실판에 의해 개구면 전계분포가 제어된다. 두 개의 무판도체 평판 사이에 손실판을 장하하면 개구면의 전계분포 및 침투전자파가 효과적으로 제어됨을 확인하고 있다.

  • PDF

Temperature Measurement of Flip Chip Joints with Peripheral Array of Solder Bumps (페리퍼럴어레이 플립칩의 온도 분포 특성)

  • Cho Bon-Goo;Lee Taek-Yeong;Lee Jongwon;Kim Jun-Ki;Kim Gangbeom
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.3 s.36
    • /
    • pp.243-251
    • /
    • 2005
  • The distribution of temperature of flip chipped device with peripheral solder bump array was measured with variables, such as the locations and geometries of heater, the size of device, the size of passivation opening. The highest temperature was measured with the larger device, $3.0(mm)\times3.0(mm)$, which has the smallest heater at the center of device and the circular passivation opening. For 2 (watts) power input, the device shows the highest temperature of about $110(^{\circ}C)$. In contrast, the smaller device, $1.5(mm)\times1.8(mm)$, shows that of $90(^{\circ}C)$. In addition to the size effect, the increase of passivation opening size decreased the maximum temperature by about $10(^{\circ}C)$. From the measurement, the temperature of device could be controlled with the size and geometry of heater, the size of device and the size and geometry of passivation opening.

  • PDF