• Title/Summary/Keyword: 강-콘크리트 합성바닥판

Search Result 58, Processing Time 0.019 seconds

Behavior of Steel-Concrete Composite Decks for PSC Girder Bridge with Various Shear Span Lengths (전단 지간의 변화에 따른 PSC 거더용 강-콘크리트 합성 바닥판의 역학적 거동)

  • Kim, Tae-Hyup;Park, Jun-Myung;Hong, Sung-Nam;Park, Sun-Kyu;Kim, Hyeong-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.275-281
    • /
    • 2007
  • Recently, steel-concrete composite structures are widely used in bridge and building constructions. In this paper, a new type of steel-concrete composite deck with profiled steel sheeting is proposed to replace the conventional cast-in-place reinforced concrete deck. Perfobond rib shear connectors were utilized to provide horizontal shear resistance between the profiled sheeting and the concrete. To validate the effectiveness of the proposed deck system, 8 full-scale deck specimens for PSC girder bridge were fabricated. The specimens were tested with four different shear span lengths to determine the horizontal shear resistance of the deck under a static monotonic loading. For comparison purpose, two reinforced concrete decks were also fabricated and tested. The horizontal shear resistance of the proposed deck system was calculated using the m-k method.

Experimental Study on the Flexural Behavior of Inverted T-Shaped Steel·Concrete Composite Deck for Bridges (역T형강·콘크리트 합성바닥판의 휨거동에 관한 실험적 연구)

  • Kim, Sung Hoon;Park, Young Hoon;Lee, Seung Yong;Choi, Jun Hyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.331-340
    • /
    • 2008
  • This study is to suggest the details of new concept of bridge deck. Experimental studies on the behavior of a inverted T-shaped steelconcrete composite deck were carried out. The part of inverted T-shaped steel is embedded in concrete. Reinforced concrete deck specimen and composite deck specimens were fabricated and static bending fracture tests were conducted. The ultimate strength and fracture strength of specimens were evaluated. The effects of shear hole crossing bars of composite deck were also analyzed. From the results of experiments, composite deck with shear hole crossing bar increased shear strength, and showed typical tensile failure. Ultimate strength and fracture strength of composite deck with shear hole crossing bar are higher than those of reinforced concrete deck. The displacement of composite deck is higher than that of reinforced concrete deck.

Analysis of Effective Flexural Rigidity of Corrugated Steel-Concrete Composite Deck with I-beam Welded (I형강으로 보강된 강합성 절곡 바닥판의 유효 휨강성 분석)

  • Son, Chang-Du;Hong, Sung-Nam;Park, Jun-Myung;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.145-154
    • /
    • 2009
  • Steel-Concrete Composite Deck with I-beam welded is lighter and easier to construct than conventional in situ reinforced concrete slabs due to the I-beam embedded in the corrugated slab. For the calculation of effective flexural rigidity of conventional reinforced concrete structures, methods suggested in Design Standard for Roads and Bridges and ACI have been used. In this paper, the calculation methods were applied to steel-concrete composite deck with I-beam welded and then results of the steel-concrete composite deck were compared with those of reinforced concrete slabs. In addition, applicability of the methods to steel-concrete composite deck with I-beam welded was estimated. In order to compare the effective flexural rigidity, flexural experiments were conducted. Fifteen slabs were built and the variables considered in the experiments were studs, length of the slab, shape of the section and connecting methods.

강.콘크리트 합성바닥판 일본 합성구조물 설계의 소개

  • 문태경
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.27-33
    • /
    • 1997
  • 현재 일본의 합성구조물의 설계에 관한 기준서는 토목학회 '강구조물의 극한강도와 설계'와 철도종합기술연구소의 '철도구조물등설계표준.동해설(강.합성구조물)'이 있다. 그리고, 토목학회.강구조위원회.강구조 극한강도 연구 소위원회에서 합성구조물의 극한강도 분과회를 조직해서, 한계상태설계법의 포멧에 따라 합성구조물의 설계지침서를 금년 여름경에 출판 할 예정이다. 본인도 합성구조물의 극한강도 분과회의 위원으로 약 3년간동안 많은 공부와 연구를 행할 수 있는 기회를 받았다. 합성구조물의 설계지침서는 합성바닥판, 합성거더와 합성기둥으로 나누어져있으며, 이번에 소개한 부분은 그중 일부분인 합성바닥판의 강판과 철근콘크리트를 적당한 전단연결재로 결합한 합성바닥판의 설계부분이다.

  • PDF

Evaluation on Effective Width of Concrete Unfilled Composite Steel Grid Deck (콘크리트 비충전 강합성 바닥판의 유효폭 평가)

  • Park, Young Hoon;Lee, Seung Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.521-529
    • /
    • 2017
  • In this study, analyzed the effective width of concrete unfilled composite steel grid deck which has different shear connector details from that of composite bridge. The effective width of concrete unfilled composite steel grid deck according to effective width calculation method, load size and main bearing bar spacing-span ratio was evaluated. As a result of analysis, it is analyzed that the effective width is calculated to be nearly equal to the actual effective width by idealizing the stress shape as a trapezoidal shape. In addition, shear hole penetration reinforcing bars applied to increase the shear strength is shown to increase the effective width. From the results of the analysis of the effective width according to main bearing bar spacing-span ratio, proposes the correction factor that can calculate the effective width ratio of the unfilled steel composite steel grid deck.

Fatigue Behavior of Steel-Concrete Composite Bridge Deck with Perfobond Rib Shear Connector (유공판재형 전단연결재를 갖는 강-콘크리트 합성바닥판의 피로거동에 관한 연구)

  • Kyung, Kab Soo;Lee, Seung Yong;Jeong, Youn Ju;Kwon, Soon Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.71-80
    • /
    • 2010
  • Bridge deck is directly influenced by environment and vehicle load, it is easily damaged so that it requires an appropriate repair and retrofit. Therefore, developing a bridge deck with high durability is necessary in order to minimize the maintenance of bridge deck and use it to its design life. In this study, static test was carried out to evaluate a fatigue capacity of steel-concrete composite deck, which was newly developed by supplementing problems of existing reinforced concrete deck. Based on results from the static test, fatigue load was decided, and fatigue test was conducted under the constant amplitude repeated load. From the fatigue tests, the S-N curve regarding principle structural details of composite deck was made, and characteristics of fatigue behavior was estimated by comparing and evaluating it with fatigue design criteria. In addition, fatigue design guideline was presented. As a result, it is found that each structural details of composite deck proposed by this study, such as upper flange of corrugated steel plate and middle section of it, shear connector and lower flange of corrugated steel plate, is satisfying the fatigue strength.

An analytical study on behavior of the girder pannel in simplified composite deck during construction (초간편 강합성 바닥판 거더패널의 가설중 거동에 관한 해석적 연구)

  • Han, Deuk-Choen;Choi, Seung-Ho;Yoon, Ki-Yong;Yi, Gyu-Se;Kim, Sang-Seup
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.108-111
    • /
    • 2007
  • 최근 현장타설 바닥판의 대안으로 강합성 바닥판을 이용하여 바닥판의 공용년수를 증진시키고 공기 단축 및 시공의 간편성, 교통흐름의 원활화등을 위한 연구가 활발히 이루어지고 있다. 본 논문에서는 기존 I형강 매입형 강합성 바닥판을 기본으로 한 새로운 형식의 초간편 강합성 바닥판을 제시하여 거동패널의 거동에 대해 연구하였다. 하부강판과 I형강의 용접량의 변화, I형강의 복부에 유공 유무, 유공의 위치변화에 대한 특성을 파악하였다 이때 H형강의 상부 플랜지는 강판과 용접된 것으로 가정하였으며, 가설시 합성전 단면에 대한 거동 분석이므로 하중은 강판, I형강, 콘크리트의 자중만 고려되었다. 연구결과, 하부강판과 I형강의 용접길이 변화시 전체용접에 비해 30%용접을 수행시 중앙부 단면에서 최대 휨 인장응력이 증가하는 결과를 보였으며, I형강 복부에 유공이 있을시 유공이 없는 경우 보다 처짐량이 약간 증가함을 확인하였다. 또한 I형강 복부의 유공 위치를 변화시킨 결과 거더패널 강바닥판의 거동에는 영향을 받지 않는 것으로 나타났다.

  • PDF

Analysis For Effective Moment For Iinertia For Corrugated Steel-Concrete Composite Deck with I-beam Welded (교량용 I형강 접합 절곡강합성 바닥판의 휨강성 분석)

  • Son, Chang-Du;Park, Jun-Myung;Han, Kyung-Bong;Kim, Jun-Won;Lee, Jae Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.209-212
    • /
    • 2008
  • Corrugated steel-concrete composite deck with I-beam welded is lighter and has higher load carrying capacity than RC slabs due to an I-beam embedded in the corrugated deck. The methods suggested from ACI and design standard of roadway bridge are used to evaluate effective moment inertia of RC structures. This paper presents evaluation and application of effective moment inertia for corrugated steel-concrete composite deck with I-beam welded by using the methods suggested from design standard of roadway bridge, ACI and CEB-FIP MC-90. In order to evaluate effective moment inertia, a series of flexural experiments were carried out. Five beams were built and the parameters considered in the experiments were studs, shape of the sections and connections of the beams. By using the aforementioned methods, effective moments of inertia was calculated and they were compared with the experimental results. As a result, The method suggested from CEB-FIP MC-90 yielded more satisfactory agreement than that from ACI. It was found that the beam has studs showed high load-carrying capacity and high effective moment of inertia.

  • PDF

An Experimental Study on the Bending Behaviour of Steel Grid Composite Deck (격자형 강합성 바닥판의 휨거동에 대한 실험적 연구)

  • Shin, Hyun Seop;Lee, Chin Hyung;Park, Ki Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.175-184
    • /
    • 2011
  • To take advantage of reduced on-site construction periods and minimize traffic impacts various types of steel grid composite deck have been developed since 1930's. Modular prefabricated unfilled grid decks permit a long-distance transportation and construction under unfavorable condition, for example, in mountainous regions due to its comparatively light-weighter structure than fully filled grid deck. In this study bending tests of unfilled grid decks for the deck member of various kinds of infrastructure are carried out, bending strength and behaviour of composite action are experimentally evaluated. In this bending test, design variables are considered, such as type of shear connection between steel grid and concrete slab, spacing between cross bars and thickness of concrete slab. Through test results bending strength and behaviour of composite action are evaluated, reference data for proper type of shear connection and other details of the deck, such as spacing between cross bars, are obtained.

Behavior of Stud Shear Connectors in Precast Deck using Lightweight Concrete (경량콘크리트를 사용한 프리캐스트 바닥판에서 스터드 전단연결재의 거동)

  • Cho, Sun Kyu;Lee, Jong Min;Youn, Seok Goo;Choi, Yun Wang
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.227-236
    • /
    • 2008
  • The kind of concrete generally used in steel concrete composite bridges is normal-weight concrete whose unit weight is ${2,300kg/m^{3}}$. However, using lightweight concrete in composite bridges diminishes the sectional forces due to the self-weight of concrete decks. As a result, this will make the bridge design more economical. The type of concrete deck that could be adopted in composite bridges using lightweight con crete may be classified into Cast-In-Place (C.I.P.) concrete deck and precast concrete deck. These two types of decks have some differences with respect to structural behavior and constructional method, and hence,structural behavior of stud shear connectors that connect a concrete deck to a steel girder is changed with the type of deck used. In this study, push-out tests were conducted to evaluate the characteristics of static behavior of the stud shear connectors with a precast deck using lightweight concrete. Also, additional precast deck specimens with bedding layer that had shear keys and devices for transverse confinement of the bedding layer for the prevention of cracks occurring in the bedding layer were tested. These cracks The efficiency of these devices was then evaluated.