Abstract
In this study, analyzed the effective width of concrete unfilled composite steel grid deck which has different shear connector details from that of composite bridge. The effective width of concrete unfilled composite steel grid deck according to effective width calculation method, load size and main bearing bar spacing-span ratio was evaluated. As a result of analysis, it is analyzed that the effective width is calculated to be nearly equal to the actual effective width by idealizing the stress shape as a trapezoidal shape. In addition, shear hole penetration reinforcing bars applied to increase the shear strength is shown to increase the effective width. From the results of the analysis of the effective width according to main bearing bar spacing-span ratio, proposes the correction factor that can calculate the effective width ratio of the unfilled steel composite steel grid deck.
본 연구에서는 합성형교와는 다른 전단연결 상세를 가지는 콘크리트 비충전 강합성 바닥판의 유효폭을 수치적으로 분석하였다. 유효폭 산정 방법 및 위치, 작용하중 크기, 메인 베아링 바 간격-지간장비에 따른 콘크리트 비충전 강합성 바닥판의 유효폭을 평가하였다. 분석 결과 응력 형태를 사다리꼴로 이상화하여 유효폭을 산출하여도 실제 유효폭과 거의 동일한 것으로 분석되었다. 또한, 전단 강도 증가를 위해 적용된 전단홀 관통 철근이 유효폭을 증가 시키는 역할을 하는 것으로 나타났다. 메인 베아링 바 간격-지간장비에 따른 유효폭 분석 결과로부터 콘크리트 비충전강합성 바닥판의 유효폭비를 산출 할 수 있는 보정 계수를 제안하였다.