DOI QR코드

DOI QR Code

Evaluation on Effective Width of Concrete Unfilled Composite Steel Grid Deck

콘크리트 비충전 강합성 바닥판의 유효폭 평가

  • 박영훈 (부천대학교 토목과) ;
  • 이승용 (한국교통대학교 건설환경도시교통공학부)
  • Received : 2016.11.18
  • Accepted : 2017.05.08
  • Published : 2017.06.01

Abstract

In this study, analyzed the effective width of concrete unfilled composite steel grid deck which has different shear connector details from that of composite bridge. The effective width of concrete unfilled composite steel grid deck according to effective width calculation method, load size and main bearing bar spacing-span ratio was evaluated. As a result of analysis, it is analyzed that the effective width is calculated to be nearly equal to the actual effective width by idealizing the stress shape as a trapezoidal shape. In addition, shear hole penetration reinforcing bars applied to increase the shear strength is shown to increase the effective width. From the results of the analysis of the effective width according to main bearing bar spacing-span ratio, proposes the correction factor that can calculate the effective width ratio of the unfilled steel composite steel grid deck.

본 연구에서는 합성형교와는 다른 전단연결 상세를 가지는 콘크리트 비충전 강합성 바닥판의 유효폭을 수치적으로 분석하였다. 유효폭 산정 방법 및 위치, 작용하중 크기, 메인 베아링 바 간격-지간장비에 따른 콘크리트 비충전 강합성 바닥판의 유효폭을 평가하였다. 분석 결과 응력 형태를 사다리꼴로 이상화하여 유효폭을 산출하여도 실제 유효폭과 거의 동일한 것으로 분석되었다. 또한, 전단 강도 증가를 위해 적용된 전단홀 관통 철근이 유효폭을 증가 시키는 역할을 하는 것으로 나타났다. 메인 베아링 바 간격-지간장비에 따른 유효폭 분석 결과로부터 콘크리트 비충전강합성 바닥판의 유효폭비를 산출 할 수 있는 보정 계수를 제안하였다.

Keywords

References

  1. Ahn, I.S., Chiewanichakorn, M., Chen, S. S. and Aref, A. J. (2004). "Effective flange width provisions for composite steel bridges." Engineering structures, Vol. 26, pp. 1843-1851. https://doi.org/10.1016/j.engstruct.2004.07.009
  2. Amadio, C. and Fragiacomo, M. (2004) "Effective width evaluation for steel-concrete composite beams." Journal of Constructional Steel Research, Vol. 58, No. 3, pp. 378-389.
  3. Castro, J. M., Elghazouli, A. Y. and Izzuddin, B. A. (2006). "Assessment of effective slab widths in composite beams." Journal of Constructional Steel Research, 63, pp. 1317-1327
  4. Chen, S. and Zhang, Z. (2005). "Effective width of a concrete slab in steel-concrete composite beams prestressed with external tendons." Journal of Constructional Steel Research, Vol. 62, pp. 493-500.
  5. Chiewanichakorn, M., Aref, A. J., Chen, S. S. and Ahn, I.-S. (2004). "Effective flange width definition for steel-concrete composite bridge girder." Journal of Structural Engineering, pp. 2016-2031.
  6. Fahmy, E. H. and Robinson, H. (1986). "Analyses and tests to determine the effective widths of composite beams in unbraced multistory frames." Canadian Journal of Civil Engineering, Vol. 13, No. 1, pp.66-75. https://doi.org/10.1139/l86-010
  7. FEA Ltd. (2002). Powerful FE technology for specialist applications. LUSAS Ver. 13.4
  8. Kim, S. H., Park, Y. H., Lee, S. Y. and Choi, J. H. (2008). "Experimental study on the flexural behavior of inverted t-shaped steel . concrete composite deck for bridges." Journal of KSCE, Vol. 28, No. 3A, pp. 331-340 (in Korean).
  9. Mohammad, A. A. Alsarraf and Hamdy Shehab El Din (2016). "Effects of web openings on the effective slab widths in composite steel beams." IACSIT International Journal of Engineering and Technology, Vol. 8, No. 1, pp. 6-10. https://doi.org/10.7763/IJET.2016.V8.849
  10. Nie, J.G., Tian, C.-Y. and Cai, C. S. (2008). "Effective width of steelconcrete composite beam at ultimate strength state." Engineering structures, Vol. 30, pp. 1396-1407. https://doi.org/10.1016/j.engstruct.2007.07.027