• Title/Summary/Keyword: 강제진동 응답

Search Result 79, Processing Time 0.023 seconds

An Investigation into the Hull-Girder Vibration Analysis of RO/RO Car/Truck Carriers (자동차운반선(自動車運搬船) 선체저차진동(船體低次振動)의 해석(解析))

  • K.C.,Kim;D.S.,Cho;J.H.,Chung;J.W.,Kang;S.J.,Moon;J.H.,Woo
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.1
    • /
    • pp.35-44
    • /
    • 1990
  • Most of the medium-size ships are powered by large-bore, long-stroke, slow-speed and two-stroke diesel engines in order to improve the fuel efficiency. Such a propulsion plant develops low-frequency excitation forces/moments of significant magnitude. A RO/RO car/truck carrier is also one of the cases. In this paper, the rational methods for analysis of vertical and coupled horizontal-torsional vibrations are presented. Taking account of unusual characteristics of the hull form and structural systems, the emphasis is put on modelling methods based on beam analogy, calculation of system parameters such as added mass and its center, polar added-mass moment of inertia, shear coefficient of hull sections and coupling degree in antisymmetric modes, and modal analysis of forced vibrations.

  • PDF

Domains of Attraction of a Forced Beam with Internal Resonance (내부공진을 가진 보의 흡인영역)

  • 이원경;강명란
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1711-1721
    • /
    • 1992
  • A nonlinear dissipative dynamical system can often have multiple attractors. In this case, it is important to study the global behavior of the system by determining the global domain of attraction of each attractor. In this paper we study the global behavior of a forced beam with two mode interaction. The governing equation of motion is reduced to two second-order nonlinear nonautonomous ordinary differential equations. When .omega. /=3.omega.$_{1}$ and .ohm.=.omega $_{1}$, the system can have two asymptotically stable steady-state periodic solutions, where .omega./ sub 1/, .omega.$_{2}$ and .ohm. denote natural frequencies of the first and second modes and the excitation frequency, respectively. Both solutions have the same period as the excitation period. Therefore each of them shows up as a period-1 solution in Poincare map. We show how interpolated mapping method can be used to determine the two four-dimensional domains of attraction of the two solutions in a very effective way. The results are compared with the ones obtained by direct numerical integration.

A Study of DC Motor Speed Control By tms-320C32 Based (TMS-320C32기반에 의한 DC 모터 속도제어의 연구)

  • Jeong, S.H.;Kwon, S.M.;Cheon, J.M.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2218-2220
    • /
    • 2003
  • 현대 산업현장에서 80%이상 사용되는 PID(proportional integral derivative) 제어기는 제어성, 적응성, 제어이득 조정 등의 특정이 있어나 제어 대상에 대한 PID 제어 계수를 경험적 방법인 수동으로 동조해야하는 문제점이 있다. 이를 개선하기 위해 본 논문에서 PID제어기의 최적 자동동조를 위한 릴레이 동조 방법을 제안한다. 기존의 한계감도법과 과도응답 법으로 초기계수를 결정하는 방법보다 유연성과 적용성이 높고, 이를 마이크로프로세서(DSP : TMS-320C32)에 적용하여 소프트웨어적으로 릴레이의 기능이 이루어지도록 설계했다. 이는 Ziegler-Nichols 계수조정법이 갖는 적용대상의 제약성을 극복한 방법이며, 릴레이에 의해 출력을 강제 진동시키고 출력의 진폭과 주기를 이용하여 PID 계수를 조정하고, 또 상대안정성의 척도인 위상여유를 고려하므로 시스템의 상대안정성과 견실성을 향상시킬 수 있음을 확인하였다.

  • PDF

Forced Vibration Analysis and Response Characteristics of a Vehicle Dull Progress Model (차량의 둔턱 진행 모델 강제진동해석과 응답특성)

  • Lee, Hyuk;Yoon, Moon-chul;Kim, Jong-Do
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.11
    • /
    • pp.49-57
    • /
    • 2020
  • The forced vibration characteristics for two impulse forces with time lag was discussed in the vehicle dull progress model. Detailed numerical analyses of the time domain were performed systematically. By the two exciting impulse forces, the responses of displacement, the velocity, and the acceleration were investigated in detail for the vehicle's vibration. Notably, the forced vibration responses in the time domain can be used to identify and monitor several vehicle vibration models. In order to define the responses of displacement, the velocity, and the acceleration, we applied a numerical technique (i.e., the Runge-Kutta-Gill method[1,2]). These variables were subsequently used to analyze the vehicle's vibration according to the time lapse and while it passed over a bump stock; moreover, the characteristics of the variables were analyzed in detail according to their force conditions. Finally, the intrinsic characteristics of the forced vibration were discussed in the context of the automobile model. Overall, our results indicate that the tested method can be successfully applied under different damped conditions.

Vibration Analysis of Mindlin-Plate Structures having Attachments by the Receptance Method (Receptance 방법에 의한 부가물을 갖는 Mindlin판유추 구조제의 진동해석)

  • S.Y. Han;J.H. Chung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.3
    • /
    • pp.98-106
    • /
    • 1995
  • In ship and offshore structures, there exist many local structural systems which may be regarded as a combined structural systems composed of thick plates or double wall panels and attachments reducible to damped spring-mass systems. For vibration analysis of such a combined system an analytical method based on the receptance method is presented in this paper. The free vibrational characteristics and forced vibration responses of the combined system can be calculated by synthesis of receptances of the panel and attachments. To calculate receptances of the panel, it may be regarded as a Mindlin plate for consideration of effects of shear deformation and rotary inertia and the assumed mode-Lagrange's equation method is applied using Timoshenko beam function or polynomials having properties of Timoshenko beam function as trial functions. Through some numerical calculations, accuracy and efficiency of the presented method are shown.

  • PDF

An Efficient Response Analysis Method for a Structural System Using Substructure Modes (부분구조의 모드를 이용한 구조계의 효율적 응답해석)

  • 김형근;박윤식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1084-1094
    • /
    • 1993
  • An efficient method for determining forced responses of a general linear structural system in time domain using subtructure modes and Lagrange multipliers is presented. Compared with the conventional mode synthesis methods, the suggested method does not construct the equations of motion of the combined whole structure and thus the modal parameters of the whole structure are not required. Only modal parameters of each substructure and geometric compatibility conditions are needed. Both the loaded interface free-free modes and free interface modes can be employed as the modal bases of each substructure. Recurrence discrete-time state equations based upon state transition matrix are formulated for the transient analysis of a parameter-changing system. It is shown form numerical examples that the suggested method is very accurate and efficient to calculate transient responses compares with the direct numerical integration method.

Vibration Test for PCB/Connector Assembly (인쇄회로기판 진동이 커넥터에 미치는 영향)

  • 허남일;김성철;송규섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.160-164
    • /
    • 1995
  • 정보통신 시스템의 고속/고밀도화 요구에 따라 개발되고 있는 ATM(Asynchronous Transfer Mode) 교환기 시스템은 팬을 이용한 강제대류냉각 방식의 채택과 시스템이 설치되는 장소에 따른 여러 환경조건에 의한 진동 문제가 발생될 수 있다. 시스템의 진동으로 인한 피해중 커넥터 접촉부에서 전기적 특성의 변화는 고속으로 전송되는 신호의 왜곡을 유발시킬 수 있어 시스템 개발시 이에 대한 충분한 연구 및 시험이 요구되고 있다. 진동환경에서 커넥터 접촉부는 접촉면의 상대운동으로 인한 접촉저항의 증가와 순간적인 신호전달 중단을 가져오게 되며, 특히 PCB/Connector Assembly에서 커넥터 접촉부는 PCB(Printed Circuit Board)의 장착 조건 및 동적 거동에 따라 전기적 특성이 변할 수 있다. 시스템에서 커넥터의 동적 거동을 이해하기 위해서는 PCB를 포함하는 시스템내 여러 요소의 동적 특성 이해와 복잡한 해석과정이 요구되며, 시스템 개발자는 진동 환경에서 이것의 시험 결과에 따라 커넥터의 사용을 결정해야 할 것이다. 커넥터의 전기적 특성 시험법은 IEC, EIA드 여러 국제 규격에 제시되어 있으며, 본 연구의 대상이 된 ATM교환기 시스템에서 PCB/Connector Assembly의 진동환경에서 접촉저항 측정과 관련된 접촉저항 임계치 및 측정법은 IEEE 규격 및 Bellcore 규격에 규정되어 있다. Bellcore에는 주어진 진동시험주기 전후에 IEC 규격의 LLCR(Low Level Contact Resistance) 측정회로를 이용한 측정법이 규정되어 있고, 냉각팬 및 주위 환경진동이 가해지는 동안의 영향에 대한 시험법은 규정되어 있지 않다. 본 연구에서는 한국통신의 전자장비 운용환경시험 조건의 진동에서 ATM 교환기 시스템에 사용되는 PCB/Connector Assembly 커넥터 접촉부의 접촉저항 변화와 PCB 진동에 의한 영향을 시험하였다.proach)등이 제시되었고 평면파 영역에 한하여 해서되어져 왔다. 본 논문에서는 분할 접근 방법(Segmentation Approach)을 이용하여 다공 요소로 이루어진 소음기를 해석하는데 적용하였다.로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다. 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity v

  • PDF

Dynamic response of nano-scale plates based on nonlocal elasticity theory (비국소 탄성 이론을 이용한 나노-스케일 판의 강제진동응답)

  • Kim, Jin-Kyu;Han, Sung-Cheon;Park, Weon-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.436-444
    • /
    • 2013
  • This article presents the dynamic response of nano-scale plates using the nonlocal continuum theory and higher-order shear deformation theory. The nonlocal elasticity of Eringen has ability to capture the small scale effects and the higher-order shear deformation theory has ability to capture the quadratic variation of shear strain and consequently shear stress through the plate thickness. The solutions of transient dynamic analysis of nano-scale plate are presented using these theories to illustrate the effect of nonlocal theory on dynamic response of the nano-scale plates. The relations between nonlocal and local theories are discussed by numerical results. Also, the effects of nonlocal parameters, aspect ratio, side-to-thickness ratio, size of nano-scale plate and time step on dynamic response are investigated and discussed. The amplitude and cycle increase when nonlocal parameter increase. In order to validate the present solutions, the reference solutions are used and discussed. The theoretical development as well as numerical solutions presented herein should serve as reference for nonlocal theories as applied to the transient dynamic analysis of nano-scale structures.

Real-time Hybrid Testing a Building Structure Equipped with Full-scale MR dampers and Application of Semi-active Control Algorithms (대형 MR감쇠기가 설치된 건축구조물의 실시간 하이브리드 실험 및 준능동 알고리즘 적용)

  • Park, Eun-Churn;Lee, Sung-Kyung;Lee, Heon-Jae;Moon, Suk-Jun;Jung, Hyung-Jo;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.5
    • /
    • pp.465-474
    • /
    • 2008
  • The real-time hybrid testing method(RT-HYTEM) is a structural testing technique in which the numerical integration of the equation of motion for a numerical substructure and the physical testing for an experimental substructure are performed simultaneously in real-time. This study presents the quantitative evaluation of the seismic performance of a building structure installed with an passive and semi-active MR damper by using RT-HYTEM. The building model that was identified from the force-vibration testing results of a real-scaled 5-story building is used as the numerical substructure, and an MR damper corresponding to an experimental substructure is physically tested by using the universal testing machine(UTM). The RT-HYTEM implemented in this study is validated because the real-time hybrid testing results obtained by application of sinusoidal and earthquake excitations and the corresponding analytical results obtained by using the Bouc-Wen model as the control force of the MR damper respect to input currents were in good agreement. Also for preliminary study, some semi-active control algorithms were applied to the MR damper in order to control the structural responses optimally. Comparing between the test results of semi-active control using RT-HYTEM and numerical analysis results show that the RT-HYTEM is more resonable than numerical analysis to evaluate the performance of semi-active control algorithms.