• Title/Summary/Keyword: 강재지보

Search Result 18, Processing Time 0.02 seconds

A Study on Strength Characteristics of Yieldable Steel Arch Supports (가축성 강재 지보의 강도특성에 관한 연구)

  • 김종우
    • Tunnel and Underground Space
    • /
    • v.8 no.4
    • /
    • pp.261-274
    • /
    • 1998
  • The brief results of laboratory and field tests of yieldable steel arches are represented. The test supports were fabricated with three U-sectional beams which are 25.8 kg/m of Glocken profile. The structural analyses of semi-circular and arch supports were conducted to find out shape factor of U beam to be 1.35 and the location of 2nd plastic hinges. Load capacity of arch supports under crown loading were examined as a function of leg length. Yieldable characheristics of test supports were investigated with various bolting torque of connection part. Determination method of bolting torque were also studied. Finally, test supports were installed in-situ with torque of 21 kg .m, which showed a typical yielding procedure.

  • PDF

Analysis for Mechanical Behavior of GFRP Rock Bolt for Permanent Support of Tunnel (영구 터널지보재로서의 활용을 위한 GFRP 록볼트의 역학적 거동 분석)

  • Sim, Jong-Sung;Kang, Tae-Sung;Lee, Yong-Taek;Kim, Hyun-Joong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.124-131
    • /
    • 2010
  • Rock Bolt generally utilizes deformed reinforcing bar welded from structural steel of which strength is higher than required for making advantageous use of the support function of ground. In the condition with highly corrosive underground water, however, problem frequently occurs on tunnel and slope stabilization in terms of repair, rehabilitation and maintenance issues due to the destruction of Rock Bolt by corrosion of steel. A structural performance evaluation for GFRP Rock Bolt was conducted for the purpose of resolving the foregoing problem and at the same time developing a permanently-usable support material. This study intended to evaluate the safety factor of GFRP Rock Bolt by implementing the slope stability interpretation via structural analysis on the basis of its structural characteristics derived from both tensile force function test and shear force function test. It is judged based on the results that GFRP Rock Bolt would secure sufficient ground stability as an alternative material for existing Steel Rock Bolt.

A Numerical Study on the Behavior of Shotcrete Reinforced by Various Steel Supports (강재로 보강된 숏크리트 거동의 수치해석적 연구)

  • Lee, Sang-Don;Park, Yeon-Jun;Lim, Doo-Chul;Son, Jeong-Hun;You, Kwang-Ho;Kim, Su-Man
    • Tunnel and Underground Space
    • /
    • v.18 no.3
    • /
    • pp.226-238
    • /
    • 2008
  • The steel ribs which are used to enhance the supporting capability of the shotcrete are estimated to be very effective, but their characteristics depending on the types of steel support are not well understood enough to be considered in the design stage. This paper describes the behavior of the shotcrete reinforced by various types of steel supports. Through flexural toughness test, major strength parameters such as flexural tensile strength, equivalent flexural tensile strength and residual tensile strength were obtained and used in the numerical analyses. Test results show that steel rebar was not as dependable as H-beam or lattice girder but close examination of the test results revealed that the specimen was failed in shear because of the shorter span than desired. Therefore tests on the properly dimensioned specimens are necessary for valid evaluation of the steel rebar reinforced shotcrete. In the first set of numerical stability analyses, shotcrete and steel supports were modelled separately. Then compared with the second set of analyses in which shotcrete and steel supports were regarded as a composite material. The two results coincided reasonably and this equivalent model turned out to be useful.

Numerical Study on Shotcrete Lining with Steel Reinforcement Using a Fiber Section Element (화이버 단면 요소를 이용한 강재 보강된 숏크리트 라이닝의 수치해석적 연구)

  • Kim, Jeong Soo;Yu, Jee Hwan;Kim, Moon Kyum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.919-930
    • /
    • 2014
  • In this study, the load capacities and behaviors of a shotcrete member with steel supports, as composite member, are investigated numerically by using a fiber section element. The cross section of a shotcrete lining with steel support is divided into a bundle of fibers, which are allocated nonlinear stress-strain relations and used for determining internal forces. To verify the used approach of the finite element method for shotcrete with steel supports, the load-displacement relations of shotcrete lining obtained by numerical analysis are compared with existing experimental results and are analyzed with the stress distribution of the shotcrete and steel support obtained numerically. As a result, it is shown that the proposed approach can predict the load capacities of each material and the overall nonlinear behavior of shotcrete lining with steel supports. The change of location of the neutral axis and the flexural resistance ratio of each material are also derived from the stress distribution of the cross section of the shotcrete lining with steel supports. From the results, it is concluded that the flexural resistance performance of steel support should be considered in shotcrete lining design.

Analysis of Nonlinear Behaviors of Shotcrete-Steel Support Lining Considering the Axial Force Effects (축력의 영향을 고려한 숏크리트-강지보 합성 라이닝의 비선형 거동 분석)

  • Yu, Jeehwan;Kim, Jeongsoo;Kim, Moon Kyum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.357-367
    • /
    • 2017
  • Bending and axial forces simultaneously occur at the cross-section of a shotcrete lining reinforced with steel supports due to the tunnel geometry. The shotcrete has changing flexural stiffness depending on the axial forces and, as a result, severely nonlinear behavior. The mechanical properties of a shotcrete-steel composite also depend on the type of steel support. This study presents a fiber section element model considering the effect of axial force to evaluate the nonlinear behavior of a shotcrete-steel composite. Additionally, the model was used to analyze the effects of different types of steel supports on the load capacity. Furthermore, a modified hyperbolic model for ground reaction, including strain-softening, is proposed to account for the ground-lining interaction. The model was validated by comparing the numerical results with results from previous load test performed on arched shotcrete specimens. The changes in mechanical responses of the lining were also investigated. Results show a lining with doubly reinforcement rebar has similar load capacity as a lining with H-shaped supports. The use of more materials for the steel support enhances the residual resistance. For all types of steel reinforcement, the contribution of steel supports during peak load decreases as the ground becomes stiffer.

Study on the Effect of the Bearing Capacity Support of tunnel by Steel Rib in the Colluvial Soils (붕적층 지반에 적용된 터널에서 강재의 지보효과에 대한 연구)

  • Ahn, Sung-Youll;Lee, Jae-Young;Ahn, Kyung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.1
    • /
    • pp.31-40
    • /
    • 2006
  • The entrance and the exit structures of tunnels are often constructed on unfavorably soft soils (colluvial soils) as a result of environment-friendly design highlighted in recent years. For construction of such a tunnel, it is essential to secure sufficient bearing capacity of the lining supports as well as that of the surrounding soils. In this regard, H-shape steel-ribs with high stiffness are commonly used for lining supports. However, it was the past convention to ignore the effect of the steel-ribs in numerical evaluation of the structural safety. This study is intended to show how the shotcrete stresses are relieved by the steelribs, on the basis of numerical data obtained from 3-dimensional finite element analysis. The effect of steel ribs to shotcrete stresses is examined at different levels of application rates, i.e., 0%, 50%, 75% and 100% of the total stiffness. The data obtained from numerical analysis was compared with in-situ measurement. The effect of st eel ribs to shotcrete stresses was verified and appropriate total stiffness was proposed in the range of 50%~75%.

  • PDF

Performance evaluation of lattice girder depending on the quality of steel (강재 품질에 따른 격자지보재의 성능평가)

  • Jung, Hyuk-Sang;Shin, Young-Wan;Song, Ki-Il;Shin, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.2
    • /
    • pp.165-173
    • /
    • 2016
  • This paper dealt with contents on the performance evaluation of standardized steel and non-standardized steel of lattice girder. Lattice girder is arch type tunnel supports made of structural steel bar and it is girder used to ensure the stability of tunnel by suppressing any transformation of ground as much as possible during tunnel excavation. The performance evaluation of lattice girder can be conducted through bending strength test, tensile strength test and tunnel standard specification specifies that welding structural steel with over 500MPa yield strength shall be used. However, it is difficult to distinguish visually between standardized steel and non-standardized steel onsite if low-quality structural steel is used. Accordingly, this paper conducted performance evaluation of standardized steel and non-standardized steel of lattice girder to point out the issue of deteriorated yield strength of non-standardized steel, while proposed a method of verifying yield strength onsite.

Introduction to the quality evaluation of lattice girder using nondestructive test (비파괴법을 활용한 격자지보의 성능평가 기법 제안)

  • Jung, Hyuk-Sang
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.431-439
    • /
    • 2016
  • This paper dealt with contents of the quality evaluation method of lattice girder utilizing non-destructive method. Quality evaluation of ordinary lattice girder is performed through the tensile strength test of structural steel and visual inspection. The tensile strength test of structural steel is performed by collecting samples of lattice girder brought into the site, during which lattice girder must be damaged to obtain sample. In addition to such disadvantage, tensile strength tester is not available at the site in most cases, requiring an inconvenient service from test certification agency. In addition, it is substituted by mile sheet issued during the production of structural steel, which inevitably lacks reliability. Furthermore, visual inspection at the site entails a problem of lack of reliability, thereby requiring a method of easily and quickly evaluating the quality of lattice girder without damaging the material. Accordingly, this study comparatively analyzed the yield strength of tensile strength test and the yield strength of instrumented indentation test with same sample. The test results ensured over 95% precision level for the instrumented indentation test, based on which a quality evaluation method based on instrumented indentation test that allowed onsite direct quality evaluation is proposed.

Development of High Strength Lattice Girder and Evaluation of Its Performance (고강도 격자지보재의 개발 및 그 성능 평가)

  • Lee, Jae-Won;Min, Kyong-Nam;Jeong, Ji-Wook;Roh, Byoung-Kuk;Lee, Sang-Jin;Ahn, Tae-Bong;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.43-57
    • /
    • 2020
  • The objective of this study was to evaluate the performance of high-strength lattice girders as a possible superior alternative to conventional steel arch ribs. For this purpose, the structural characteristics of supports were analyzed using numerical analysis, and their performance was evaluated using maximum bending load tests and tensile tests of the welded joint. According to the results of structural analysis, the optimum size of the upper and lower members and plates is 50 mm × 31.8 mm × 25.4 mm, demonstrating excellent functionality and economic efficiency. High-strength lattice girders of dimensions 55 mm × 30 mm × 20 mm and 85 mm × 30 mm × 20 mm, determined from bending load tests, are found to meet both the reference values and the target values of H-profiles 100 and 125. A review of the ratio of theoretical deflection to actual deflection shows that the high-strength lattice girder developed during this study meets fewer than five of the evaluation criteria for lattice girder deflections proposed by the Federal Railway Department of Germany. Finally, tensile test results reveal that the welded joint of the high-strength lattice girder at the main steel bar-auxiliary steel bar-plate junction exceeds the target value, indicating that the welded joint has sufficient stability.

Development of Trenchless Tunneling Method Using Pressurizing Support and Its Field Application (가압식 지보를 이용한 비개착 터널공법 개발 및 현장적용 사례)

  • Kim, Dae-Young;Lee, Hong-Sung;Sim, Bo-Kyoung
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.7
    • /
    • pp.17-30
    • /
    • 2012
  • A new trenchless tunneling method using pressurizing support has been developed. As it overcomes shortcomings of conventional methods, it is applied to the field. The main concept of the new method is the pressurization system which, by means of pressurization bag between outer flange of steel ribs and excavated perimeter, applies the pressure corresponding to the magnitude of the relaxed earth pressure caused by excavation to the ground to prevent ground displacement. The stability of the support members and effect of displacement control of the new method were verified through several ways such as numerical tests and various model tests. The new method was applied to the construction of a 10.7 m wide, 7.9 m high and 85 m long road tunnel that passes under Yeongdong Expressway. By applying the new method, the tunnel construction was successfully completed in 13.5 months. It decreases the construction period to 35% compared to that of conventional methods, and ground displacement was almost negligible.