• Title/Summary/Keyword: 강우 월류수

Search Result 33, Processing Time 0.026 seconds

Effects of Disinfectant Concentration, pH, Temperature, Ammonia, and Suspended Solids on the Chlorine Disinfection of Combined Sewer Overflow (소독제 농도, pH, 온도, 암모니아 농도, 부유물질이 강우 월류수 염소 소독에 미치는 영향)

  • Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.685-690
    • /
    • 2014
  • The treatment of combined sewer overflow (CSO) is one of potential concerns in domestic wastewater treatment in Korea due to the pre-announce of CSO regulations. This work investigated the effects of disinfectant (NaOCl) concentration (0.11 to 4.0 mg $Cl_2/L$), pH (6.5 to 8.0), temperature (15 to $25^{\circ}C$), ammonia (10 to 41 mg N/L), and suspended solids (91 to 271 mg SS/L) on the chlorine disinfection of CSO. The effect of NaOCl concentration on the pseudo-$1^{st}$ order reaction rate for total coliform inactivation was described well with a saturation-type model with the half-velocity constant of 1.212 mg/L. The total coliform inactivation reaction rate decreased with SS and pH, and increased with temperature. Ammonia in the examined range did not affect the disinfection kinetics. A chlorine contact tank with the injection chlorine level of 1 mg $Cl_2/L$ and the hydraulic retention time of 1.25 min is estimated to reduce total coliform from $1{\times}10^5MPN/mL$ to 1,000 MPN/mL at 271 mg SS/L, $15^{\circ}C$, and pH 8.0. Chlorine would be a proper option for the disinfection of CSO.

A Study on Characteristics of Nonpoint Pollution using Initial Overflows of Urban Stream (도시하천의 초기월류수를 이용한 비점오염특성 연구)

  • Kang, Yong-Tae;Han, Sang-Yun;Cho, Yong-Hyun;Song, Kuen-Kwan;Jeon, Jong-Gyu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.116-118
    • /
    • 2007
  • 비강우시와 강우시 학장천의 수질은 BOD, COD, T-N, T-P, SS에 대해 각각 $11.0{\sim}31.3mg/L$, $15.6{\sim}31.4mg/L$, $5.762{\sim}15.937mg/L$, $0.918{\sim}1.291mg/L$, $18.1{\sim}31.41mg/L$$27.2{\sim}65.11mg/L$, $32.1{\sim}73.2rng/L$, $13.409{\sim}18.051mg/L$, $1.263{\sim}2.282mg/L$, $66.0{\sim}417.9mg/L$로 나타나 학장천은 전형적인 생활하수의 특성을 지녔으며, 강우시 발생되는 초기월류수에 다량의 비점오염물질이 포함됨을 알 수 있었다. 강우시 발생된 월류수의 유량을 측정한 결과 학장천의 유출계수는 $0.61{\sim}0.83$의 범위였고, 초기세척효과는 SS>T-N>COD>BOD>T-P>1 의 순서로 그 정도가 크게 나타났다. 학장천 초기월류수의 유량가중평균농도를 산정한 결과 대부분의 항목에서 청천시의 수질농도보다 높게 나타나 강우에 의한 월류수의 비점오염물질의 유출이 심각함을 알 수 있다.

  • PDF

Impacts Assessments of River Linked with Runoff Characteristics of Non-Point Source by CSOs in Urban Area (도시지역 월류수에 의한 비점오염원의 유출 특성과 연계한 하천 영향 평가)

  • Kim, You-Seong;Ko, Hyuk-Bae;Ahn, Sang-Dae;Kim, Won-Il;Ahn, Won-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.92-96
    • /
    • 2008
  • 최근에 이상기후로 인한 집중호우는 단시간의 높은 강우 강도의 발생을 증가시켜 재해 유발의 측면에서 뿐만 아니라 유역 내 비점오염원이 합류식 관거의 월류수인 CSOs(Combined Sewer Overflows)의 형태로 강우와 함께 유입되어 수질 및 환경을 오염시키는 문제점이 발생한다. 이에 따라 월류수의 유출특성에 대한 정량적인 분석을 통하여 유량 및 수질 등의 오염부하량에 대한 적절한 저감 방안이 요구되고 있는 실정이다. 이에 본 연구에서는 비점오염원의 농도가 상대적으로 높은 도시유역에 강우로 인한 월류수의 유출 특성 변화를 분석함과 동시에 월류수가 하천에 방류되었을 때의 하천에 미치는 영향 분석을 통하여 하천의 효율적인 수질 관리 방안을 제시하고자 한다. 경기도 구리시를 대상유역으로 선정하였으며, 도시 강우-유출 모델인 SWMM을 사용하여 유역의 유출량 및 월류수의 수질 모의를 수행하였으며, 유역의 최종 방류구에 비점오염 저감을 위해 설치된 저류지를 통해 하천으로 배출되는 유출수와의 연계는 미국 환경청에서 개발된 WASP 모델을 적용하여 왕숙천 본류에 대한 월류수 변화가 하천에 미치는 영향을 분석하였다. 저류지 설치 전 후의 하천에 월류수가 미치는 영향을 BOD 농도를 중심으로 비교 분석하였다. 분석 결과 저류지 설치 후 BOD 농도의 저감율은 설치 전 보다 최소 1.9%, 최대 81.2%의 저감 효과가 있는 것으로 분석되었다. 향후 신뢰도 높은 수질모의를 위해서는 월류수 발생시 월류수와 하천의 지속적인 모니터링을 통해 현장 여건을 반영할 수 있는 입력변수의 도출이 매우 중요한 것으로 나타났다.

  • PDF

Estimation of NPS Pollutant Loads using Long-term Outflow Simulation (장기유출 모의를 통한 비점오염 부하 산정)

  • Lee, jung-ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2010.05a
    • /
    • pp.644-646
    • /
    • 2010
  • 최근 비점오염원 제어를 위해 오염총량제(Total Maximum Daily Loads, TMDL)가 도입되었으며, 이것은 도시유역에서의 대표적 비점오염원인 합류식 하수관거 월류수(Combined Sewer Overflows, CSOs)의 발생에 대한 분석이 선행되어야 한다. CSOs를 산정하기 위한 방법으로는 두 가지가 있다. 첫째, 확률강우량 분석에 의한 유출량 모의 방법으로, 이것은 표준강우사상에 의한 연간 CSOs 산정에 국한되는 한계를 가지고 있다. 둘째, 관측 강우 자료를 이용한 장기유출모의(LOS) 방법으로, 이 방법은 장기간의 강우 자료를 이용할 경우 최근의 강우 변화 양상을 반영하기 어려우며, 반면 단기간의 강우 자료를 이용할 경우 결과에 대한 신뢰도를 보장할 수 없다. 본 연구에서는 연간 CSOs 발생량 및 오염부하량을 산정하기 위하여 강우발생모형과 Long-term Outflow Simulation 모형을 이용하였다. 본 연구를 통한 CSOs의 산정은 앞서 언급된 기존 방법들의 문제점을 해결하고자 개발되었으며, 향후 도시화에 따른 유출 변화 및 유역 물순환 변화에 대한 연구에 활용될 수 있다.

  • PDF

A Water Quality Modeling Study of Chunggye Stream during Combined Sewer OverFlow Period (합류식 하수관거 월류수 유입 기간 동안에 나타나는 청계천 수질 변화 모델 연구)

  • Yi, Hye-Suk;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1340-1346
    • /
    • 2005
  • A water quality modeling study was performed for Chunggye stream during combined sewer overflow(CSO) period, utilizing the diagnostic system for water management in small watershed, CREEK-1(Cyber River for Environment and Economy in Korea). This system integrated geogaphic information system, data base, landscape ecological model(FRAGSTATS), watershed model(SWMM), water quality model (WASP5), and computer graphic. In this study, the watershed model and water quality model were extensively utilized so as to simulate water qualities and flow in Chunggye stream during wet periods. The Chunggye stream watershed was divided into 18 sub-basins in the watershed model and the stream reach into 11 segments in the water quality model. The watershed model was validated against field measurements of BOD, TN, TP, and flow at the downstream location, where the model results showed a reasonable agreement with the field measurements at all parameters. From this study, it was shown that the stream water quality would change along with elapsed time from rainfall start as well as rainfall intensity. The model results indicated that the water quality would significantly upgrade due to the first flush and high sewage ratio of CSO at the beginning of rainfall event, but become degraded along with the runoff increase due to dilution effect.

Study on Characteristics of CSOs in Asan City (합류식 하수관거 월류수 발생특성 연구 - 아산시 모종처리구역을 중심으로)

  • Oh Kyung Seok;Ho Jong-Kwang;Kim Kyung-Won;Hwang Byung-Gi
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.278-280
    • /
    • 2004
  • 본 연구에서는 아산시의 모종처리구역을 대상으로 합류식 하수관거 월류수의 발생특성을 파악하고자 유량 및 오염물질 발생경향, 오염물질별 상관관계 등에 대하여 살펴보았다. 조사 결과, 강우시 월류 발생초기의 오염물질의 농도는 강우에 의한 초기세척현상(First Flush)에 의해 상당히 높게 나타났으며, 강우초기의 높은 오염물질의 농도는 강우에 의해 희석되어 일시적으로 낮아졌다가 높은 강우강도에 의하여 급격히 상승하였으며, 이후 오염물질의 농도는 유량의 감소에 따라 점차적으로 감소하는 것으로 나타났다. 또한 수질항목별 상관계수를 보면, SS와 TP의 상관계수가 가장 크게 나타났으며, COD와 TP, SS와 COD의 순으로 상관계수가 높은 것으로 나타났다.

  • PDF

Evaluating origin of pollution load by stormwater runoff in Hongje basin -Focussing Gugi catchment (홍제천 유역의 강우유출수 오염부하 기원평가 -구기 배수분구를 중심으로)

  • Oh Kyung-Seok;Ho Jong-Kwang;Hwang Byung-Gi
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.288-291
    • /
    • 2004
  • 강우유출수의 오염기원별 기여도를 파악하고자 홍제천 유역의 구기 배수분구를 대상으로 강우시 유량 및 오염물질 발생경향 및 오염기원별 오염도 분석 등에 대하여 살펴보았다. 강우시 발생초기의 오염물질의 농도는 강우에 의한 초기세척현상(First Flush)에 의해 상당히 높게 나타났으며, 강우초기의 높은 오염물질의 농도는 강우에 의해 희석되어 일시적으로 낮아졌다가 높은 강우강도에 의하여 급격히 상승하였으며, 이후 오염물질의 농도는 유량의 감소에 따라 점차적으로 감소하는 것으로 나타났다. 물질수지식을 이용한 근사적인 오염부하의 오염원별 기여도 분석에서 관거 퇴적물에 의한 오염도가 COD $27.7\%$, SS $47.5\%$로 나타났으며 지역에 따라서는 건기 하수보다도 더 높은 기여도를 보이고 있어 월류수 오염부하의 제어측면에서 정기적인 관거내 퇴적물의 준설과 세정을 통하여 상당량의 오염부하를 저감시킬 수 있는 것으로 나타났다.

  • PDF

Study on characteristics of CSOs in urban area -Focus on Pyungchang catchment of Hongje basin (도시지역 합류식 하수관거 월류수 발생특성 연구 - 홍제천 평창배수분구을 중심으로)

  • Oh Kyung-Seok;Ho Jong-Kwang;Hwang Byung-Gi
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.284-287
    • /
    • 2004
  • 홍제천 유역의 평창 배수분구를 대상으로 합류식 하수관거 월류수의 발생특성을 파악하고자 유량 및 오염물질 발생경향, 오염물질별 상관관계, 연간 강우유출 오염부하량 등에 대하여 살펴보았다. 강우시 오염물질의 초기세척현상은 누적오염 부하량비를 이용하여 분석하였으며, 모든 수질항목에 대하여 초기유출현상이 나타났으며, 초기 $20\%$ 유출 유량에서 오염부하가 $30\%$ 정도로 유출되고 있는 것으로 분석되었다. 또한 수질항목별 상관계수를 보면, 건기시의 상관계수는 COD와 SS가 0.4857, 월류수의 경우에는 SS와 TN의 상관계수가 0.7723으로 가장 크게 나타났다. 연간 강우에 의하여 방류선으로 배출되는 면적당 오염부하는 COD 1,202kg/ha/yr SS 494kg/ha/yr로 산정되었다.

  • PDF

Effects of Combined Sewer Overflows According to Drainage Basin Types (유역형상에 따른 합류식 하수도의 월류부하량 추정)

  • Lee, Cheol-Kyu;Hyun, In-Hwan;Jeong, Jeong-Youl;Shim, Jae-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.4 s.15
    • /
    • pp.21-26
    • /
    • 2004
  • It is muck important to determine the intercepting capacities as measures for reducing the load of contamination influenced by CSOs during wet weather period. Intercepting and treating the whole rainfalls can be best measured for reducing the contamination load, but it is not desirable in view of scale and preservation of the wastewater treatment facilities. This study analyzed the quantity and quality of the water in the combined sewer by method of changing the type and size of drainage basin and intercepting capacities in rainfalls, estimate the influence the other CSOs at the change of planned intercepted quantity, and compared the degree of contamination load between the combined system and separate system by examining the influence of the other CSOs at the change of planned intercepted quantity.

Estimation of Interevent Time for Management of Non-Point Source Pollutants (비점오염원 관리를 위한 독립호우 결정)

  • Lee, Eui Hoon;Yoo, Do Geun;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3159-3168
    • /
    • 2014
  • Interevent Time Definition(IETD) is essential in CSOs(Combined Sewer Overflows) tank design for the treatment of non-point source pollution. However, existent rainfall analysis can not calculate total amout of non-point source pollution. For deviding continuous rainfall events, therre are several IETD calculating methods. In this research, After calculate IETD by existents methods, problem of results is identified as existents method. To supplement these problems, new method using exponential decay function is suggested. The confidence range of ${\lambda}$ is estimated.