• Title/Summary/Keyword: 갑상선 스캔

Search Result 53, Processing Time 0.046 seconds

The Usefulness of Diagnostic Scan Using Technetium-99m Pertechnetate Scintigraphy prior to the First Ablative Radioiodine Treatment in Patients with Well Differentiated Thyroid Carcinoma: A Comparative Study with Iodine-131 (분화된 갑상선암 수술 후 초치료에 있어서 Tc-99m Pertechnetate을 이용한 진단 스캔의 유용성: Iodine-131 스캔과의 비교)

  • Yoon, Seok-Nam;Park, Chan-H.;Hwang, Kyung-Hoon;Kim, Su-Zy;Soh, Eui-Young;Kim, Kyung-Rae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.285-293
    • /
    • 2000
  • Purpose: A prospective comparison was made between imaging with Tc-99m pertechnetate (Tc-99m) and Ioine-131 (I-131) for the detection of residual and metastatic tissue after total thyroidectomy in patients with well-differentiated thyroid carcinoma. Materials and Methods: Initially our patients had imaging with Tc-99m, followed by I-131 within 3 days. The study included 21 patients who had ablation with high dose of I-131 ranging from 100 mCi to 150 mCi. Planar and pinhole images were acquired for both Tc-99m and I-131. Diagnostic images of Tc-99m and I-131 were compared with post-therapy images. Degree of uptake on Tc-99m and I-131 images was scored by four point scale and compared. Results: The results of the Tc-99m study were: 16 of 19 studies (84%) were positive on simple planar images, but 19 of 20 studies (95%) were positive on pinhole images. Conventional I-131 diagnostic imaging on the other hand showed that all studies (100%) were positive on both planar and pinhole images. There was a significant difference in degree of uptake between Tc-99m and I-131 planar images (p<0.05). Only one case of Tc-99m scintigraphy was negative on both planar and pinhole studies (false negative). There was no distant metastasis on the therapeutic I-131 images. Conclusion: Tc-99m scan using pinhole in certain clinical situations is an alternative to the I-131 scan in detecting thyroid or lymph node metastasis prior to the first ablative treatment after thyroidectomy for well-differentiated thyroid carcinoma.

  • PDF

Thyroid Carcinoma Presenting as Hot nodule on Technetium-99m Pertechnetate Thyroid Scintigraphy (Technetium-99m Pertechnetate 갑상선 스캔에서 열결절로 나타난 갑상선암)

  • Shong, Young-Kee;Lee, Mun-Ho;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Myung-Hae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.147-150
    • /
    • 1992
  • In general, hot nodules on techetium scan are regarded as benign tumors, and usually no further work up for malignancy is indicated, if they are truly autonomous. The authors experienced two cases of thyroid carcinoma presenting as hot nodule on technetium-99m pertechnetate thyroid scintigraphy. One case with papillary carcinoma, and other case with follicular carcinoma are presented in addition to a review of the literature.

  • PDF

Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan (흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감)

  • Lee, Jun Seok;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • In chest and abdomen CT scans, the radiation exposure doses by scattering lines were measured at the eyeball and thyroid. Radiation exposure was investigated by using shielding devices. The chest and abdomen CT scan protocols used in the real examination were applied to measure and compare radiation doses before and after the use of shielding devices at the eyeball and the thyroid. The radiaton doses were measured with OSLD dosimeters. Barium, tungsten sheets, goggles and neck shields were used to protect the scattered X-ray. The chest CT scans showed respectively 3.01 mSv and 6.21 mSv at the eyeball and the thyroid by the scattered X-ray. The abdomen CT scans showed 0.55 mSv and 3.22 mSv for the eyeball and the thyroid respectively. Barium and tungsten sheets had 11% to 13% protection rates at the eyeball and the thyroid for chest CT scan, and 34% to 49% reduction in radiation dose for the abdomen CT scan. Because of the significant radiation dose, which causes cataracts and thyroid cancer by the repeated and continuous radiation exposure, for the chest and the abdomen CT scans, it is required to use shielding devices to reduce radiation dose for examinations.

Comparison Study of Lesion Localization in Patients with Primary and Secondary Hyperparathyroidism using Double-Phase Tc-99m Sestamibi Scintigraphy (일차성 및 이차성 부갑상선기능항진증 환자에서 Double-Phase Tc-99m Sestamibi 스캔에 의한 병변의 국소화에 관한 비교)

  • Jeon, Tae-Joo;Lee, Jong-Doo;Rhyu, Young-Hoon;Park, Jung-Soo;Jang, Hang-Seok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.368-380
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate and compare the scintigraphic findings and diagnostic accuracy of double-phase Tc-99m sestamibi scan in primary and secondary hyperparathyroidism (HPT). Materials and Methods: We retrospectively reviewed 16 cases of primary (18 lesions) and 11 cases of secondary HPT (44 lesions) who underwent Tc-99m-sestamibi scan before the surgical intervention. Scan was performed using LEM camera (Siemens, Germany) after the injection of 740MBq of Tc-99m sestamibi. Routine image consisted of baseline and 3-hour delayed images and each image was obtained using both parallel and pine hole collimator. The study population was 27 patients (male/female=5/22, age: $49.1{\pm}10.8$). Results: Eighteen lesions of primary HPT consisted of 13 adenomas and S hyperplasias, while all lesions of secondary HPT were hyperplasias. Among the case of primary HPT, we could detect all the lesions of 13 adenomas but only 2 lesions of 5 hyperplasias (40%) could be detected by double phase scintigraphy. Three cases of primary lesion showed decreased uptake in delayed images compared with baseline. The sensitivity, specificity, positive predictive value and accuracy of primary and secondary HPT were 58.8% (10/17), 83.3% (10/12), 83.3% (10/12), 75.9% (22/29), and 37.5% (15/40), 50% (2/4), 88.2% (15/17), 38.6% (17/44), respectively. Overall sensitivity, specificity, positive predictive value and accuracy were 43.9% (25/57), 75% (12/16), 86.2% (25/29), and 53.4% (39/73). There were no statistical difference between the weight of primary and secondary HPT lesion (p>0.05). Conclusion: Tc-99m sestamibi scan is fairly good modality to detect parathyroid lesion in patient with primary HPT before the surgical intervention. However, since some of cases may reveal decreased uptake in delayed image, a careful attention to the findings of baseline images may be helpful. Still the low accuracy of sestamibi scan in diagnosis of secondary HPT prohibits routine use of it for this disease.

  • PDF

The Usefulness of $^{99m}Tc$-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism (원발성 부갑상선 기능 항진증의 수술전 병소확인에서 $^{99m}Tc$-Sestamibi 스캔의 유용성)

  • Baik, S.H.;Kim, S.M.;Choi, K.M.;Choi, Y.S.;Kim, S.J.;Yu, J.M.;Choi, D.S.;Choe, J.C.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.465-472
    • /
    • 1995
  • An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and $^{201}T1/^{99m}Tc$ subtraction scan. Among them $^{201}T1/^{99m}Tc$ subtraction scan is known as the most accurate tool for preoperative localization. Recently $^{99m}Tc$-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with $^{201}T1/^{99m}Tc$ subtraction imaging and $^{99m}Tc$-Sestamibi. The sensitivities of the $^{99m}Tc$-Sestanibi, $^{201}T1/^{99m}Tc$ subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of $^{99m}Tc$-Sestamibi and $^{201}T1/^{99m}Tc$ subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the $^{99m}Tc$-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.

  • PDF

Determination of Therapeutic Dose of I-131 for First High Dose Radioiodine Therapy in Patients with Differentiated Thyroid Cancer: Comparison of Usefulness between Pathological Staging, Serum Thyroglobulin Level and Finding of I-123 Whole Body Scan (분화 갑상선암 수술 후 최초 고용량 방사성옥소 치료시 투여용량 결정: 병리적 병기, 혈청 갑상선글로불린치와 I-123 전신 스캔의 유용성 비교)

  • Jeong, Hwan-Jeong;Lim, Seok-Tae;Youn, Hyun-Jo;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.301-306
    • /
    • 2008
  • Purpose: Recently, a number of patients needed total thyroidectomy and high dose radioiodine therapy (HD-RAI) get increased more. The aim of this study is to evaluate whether pathological staging (PS) and serum thyroglobulin (sTG) level could replace the diagnostic I-123 scan for the determination of therapeutic dose of HD-RAI in patients with differentiated thyroid cancer. Materials and Methods: Fifty eight patients (M:F=13;45, age $44.5{\pm}11.5\;yrs$) who underwent total thyroidectomy and central or regional lymph node dissection due to differentiated thyroid cancer were enrolled. Diagnostic scan of I-123 and sTG assay were also performed on off state of thyroid hormone. The therapeutic doses of I-131 (TD) were determined by the extent of uptakes on diagnostic I-123 scan as a gold standard. PS was graded by the criteria recommended in 6th edition of AJCC cancer staging manual except consideration of age. For comparison of the determination of therapeutic doses, PS and sTG were compared with the results of I-123 scan. Results: All patients were underwent HD-RAI. Among them, five patients (8.6%) were treated with 100 mCi of I-131, fourty three (74.1%) with 150 mCi, six (10.3%) with 180 mCi, three (5.2%) with 200 mCi, and one (1.7%) with 250 mCi, respectively. On the assessment of PS, average TDs were $154{\pm}25\;mCi$ in stage I (n=9), $175{\pm}50\;mCi$ in stage II (n=4), $149{\pm}21\;mCi$ in stage III (n=38), and $161{\pm}20\;mCi$ in stage IV (n=7). The statistical significance was not shown between PS and TD (p=0.169). Among fifty two patients who had available sTG, 25 patients (48.1%) having below 2 ng/mL of sTG were treated with $149{\pm}26\;mCi$ of I-131, 9 patients (17.3%) having $2{\leq}\;sTG\;<5\;ng/mL$ with $156{\pm}17\;mCi$, 5 patients (9.6%) having $5{\leq}\;sTG\;<10\;ng/mL$ with $156{\pm}13\;mCi$, 7 patients (13.5%) having $10{\leq}sTG\;<50\;ng/mL$ with $147{\pm}24\;mCi$, and 6 patients (11.5%) having above 50 ng/mL with $175{\pm}42\;mCi$. The statistical significance between sTG level and TD (p=0.252) was not shown. Conclusion: In conclusion, PS and sTG could not replace the determination of TD using I-123 scan for first HD-RAI in patients with differentiated thyroid cancer.