• Title/Summary/Keyword: 감압장치

Search Result 77, Processing Time 0.035 seconds

Significance of Intraoperative BAEPs Monitoring during Microvascular Decompression Surgery (미세혈관 감압술중 뇌간청각유발전위 감시장치의 유용성)

  • Kim, Tae Joon;Ko, Yong;Kim, Young Soo;Oh, Seong Hoon;Kim, Kwang Myung;Kim, Nam Kyu;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.5
    • /
    • pp.635-639
    • /
    • 2000
  • Objective : Surgery for the microvascular decompression is mostly concerned with injury to the cranial nerves or brain stem by cerebellar retraction. Intraopeartive brain stem auditory evoked potentials(BAEPs) has been continuously monitored on surgery to evaluate the extent of injury, recovery of the nerves and prognosis. Methods : Of the 161 cases of CP angle surgery from Feb. 1996 to Apr. 1998, 103 cases were monitored during operation. Thirty five patients who had undergone similar surgery were selected and evaluated ; 23 patients were monitored and 12 were not during surgery. If monitor showed more than 0.5 mSec delay of latency, surgeon was given a warning not to retract brain any more. If more than 1mSec delay, surgeon was informed to stop surgery and wait for the returning of evoked potentials. The level of amplitudes and delay of latencies during the initial stage of operation, opening the dura, insertion of teflon patches, and closing the dura and recovery were then compared. Resuls : Twenty patients were male and 15 were female. Their average age was 50.26 years. Mean amplitude during the initial stage of operation was $0.60{\pm}0.25mV$, at opening the dura $0.56{\pm}0.26$, after teflon patches insertion $0.49{\pm}0.20$, and after closure of dura $0.47{\pm}0.28mV$. Mean latency during the early stage of operation was $6.08{\pm}0.67mSec$, at opening of dura $6.38{\pm}0.55$, insertion of teflon $6.97{\pm}0.59$, and closing the dura $6.17{\pm}0.54$. There was statistical significance in the difference of amplitudes between each procedures, and in the difference of latencies. For the complete recovery of amplitude and latency, it usually took average 5.65 minutes(0-20 min). In monitored group, only one patient required more than 20 minutes to recover and suffered from hearing disturbance after surgery. Others were recovered within 10 minutes without complications. However, 4 out of 12 patients who were not monitored showed hearing disturbance, and 1 patient had temporary facial palsy and dizziness(p=0.000). Conclusion : The results indicate that continuous intraoperative monitoring of BAEPs during CP angle surgery is seen mandatory procedure to prevent operative complications.

  • PDF

Fundamental Study on a Distillation Separation of a LiCl-KCl Eutectic Salt from Rare Earth Precipitates (희토류 침전물로부터 LiCl-KCl 공융염의 증류 분리에 관한 기초연구)

  • Yang, Hee-Chul;Eun, Hee-Chul;Kim, In-Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.1
    • /
    • pp.65-70
    • /
    • 2010
  • The distillation rate on LiCl-KCl eutectic salt under different vacuums from 0.5-50 mmHg was first investigated by using both a non-isothermal and a isothermal thermogravimetric (TG) analysis. Based on the non-isothermal TG data, distillation rate equations as a function of the temperature could be derived. Calculated flux by these model flux equations was in agreement with the distillation rate obtained from isothermal TG analysis. A distillation rate of $10^{-4}-10^{-5}$ mole $cm^{-2}sec^{-1}$ is obtainable at temperatures less than 1300K and vacuums of 0.5-50 mmHg. About a 99% salt distillation efficiency was obtained after an hour at a temperature above 1150 K under 50 mmHg in a small scale distillation test system. An increase in the vaporizing surface area is relatively effective for removing residual salt in the remaining particles, when compared to that for the vaporizing time. Over 99.95% of total distillation efficiency was obtained for a 1-h distillation operation by increasing the inner surface area from $4.52cm^2$ to $12.56cm^2$.

A Study on the Utilization and Control Method of Hybrid Switching Tap Based Automatic Voltage Regulator on Smart Grid (스마트그리드의 탭 전환 자동 전압 조정기의 다중 스위칭 제어 방법 및 활용 방안에 관한 연구)

  • Park, Gwang-Yun;Kim, Jung-Ryul;Kim, Byung-Gi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.31-39
    • /
    • 2012
  • In this paper, we propose a microprocessor-based automatic voltage regulator(AVR) to reduce consumers' electric energy consumption and to help controlling peak demanding power. Hybrid Switching Automatic Voltage Regulator (HS-AVR) consist of a toroidal core, several tap control switches, display and command control parts. The coil forms an autotransformer which has a serial main winding and four parallel auxiliary windings. It controls the output voltage by changing the combination of the coils and the switches. Relays are adopted as the link switches of the coils to minimize the loss. To make connecting and disconnecting time accurate, relays of the circuit have parallel TRIACs. A software phase locked loop(PLL) has been used to synchronize the timings of the switches to the voltage waveform. The software PLL informs the input voltage zero-crossing and positive/negative peak timing. The traditional voltage transformers and AVRs have a disadvantage of having a large mandatory capacity to accommodate maximum inrush current to avoid the switch contact damage. But we propose a suitable AVR for every purpose in smart grid with reduced size and increased efficiency.

Development of the Most Optimized Ionizer for Reduction in the Atmospheric Pressure and Inert Gas Area (감압대기 및 불활성가스 분위기에서 적합한 정전기 제거장치의 개발)

  • Lee, Dong Hoon;Jeong, Phil Hoon;Lee, Su Hwan;Kim, Sanghyo
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.42-46
    • /
    • 2016
  • In LCD Display or semiconductor manufacturing processes, the anti-static technology of glass substrates and wafers becomes one of the most difficult issues which influence the yield of the semiconductor manufacturing. In order to overcome the problems of wafer surface contamination various issues such as ionization in decompressed vacuum and inactive gas(i.e. $N_2$ gas, Ar gas, etc.) environment should be considered. Soft X ray radiation is adequate in air and $O_2$ gas at atmospheric pressure while UV radiation is effective in $N_2$ gas Ar gas and at reduced pressure. At this point of view, the "vacuum ultraviolet ray ionization" is one of the most suitable methods for static elimination. The vacuum ultraviolet can be categorized according to a short wavelength whose value is from 100nm to 200nm. this is also called as an Extreme Ultraviolet. Most of these vacuum ultraviolet is absorbed in various substances including the air in the atmosphere. It is absorbed substances become to transit or expose the electrons, then the ionization is initially activated. In this study, static eliminator based on the vacuum ultraviolet ray under the above mentioned environment was tested and the results show how the ionization performance based on vacuum ultraviolet ray can be optimized. These vacuum ultraviolet ray performs better in extreme atmosphere than an ordinary atmospheric environment. Neutralization capability, therefore, shows its maximum value at $10^{-1}{\sim}10^{-3}$ Torr pressure level, and than starts degrading as pressure is gradually reduced. Neutralization capability at this peak point is higher than that at reduced pressure about $10^4$ times on the atmospheric pressure and by about $10^3$ times on the inactive gas. The introductions of these technology make it possible to perfectly overcome problems caused by static electricity and to manufacture ULSI devices and LCD with high reliability.

Effect of Microwave Plasma on Sterilization of Acidovorax citrulli Infected Watermelon Seeds (저온플라즈마(Microwave Plasma)를 활용한 Acidovorax citrulli 감염 수박종자의 살균 효과 검정)

  • Kim, Sang Woo;Ju, Han Jun;Gwon, Byeong Heon;Adhikari, Mahesh;Kim, Hyun Seung;Park, Mi-Ri;Lee, Youn Su
    • Research in Plant Disease
    • /
    • v.27 no.1
    • /
    • pp.8-16
    • /
    • 2021
  • This study was conducted to check the sterilization efficacy of microwave plasma (MWP) against the watermelon seeds infected with Acidovorax citrulli 11-251. Watermelon seeds were artificially vacuum inoculated to produce A. citrulli 11-251 infected seeds. Aac ImmunoStrip and scanning electron microscope (SEM) results suggests that, seeds (coat and endosperm) were infected under the concentration of 1×107/30 min. MWP sterlization process was carried out at 50 W (3 min, 5 min, and 10 min), 80 W (3 min, 5 min, and 10 min), and 100 W (3 min, 5 min, and 10 min). According to the results, MWP sterilized the artificially inoculated seed coats by 95.96% at 80 W/10 min and seed endosperms by 100% at 100 W/10 min respectively. Although, seeds were sterlized by MWP, germination rate of seeds were low as compared to non treated (negative control) seeds. Moreover, cell membrane of A. citrulli 11-251 was damaged while observed in SEM after sterilized with MWP. Further studies regarding the appropriate sterilization condition by MWP against A. citrulli infected seeds for germination will be conducted in our next study.

A sensitive analytical method for determination of 3-monochloropropane-1,2-diol and 1,3-dichloropropan-2-ol in various foods by gas chromatography with mass spectrometer (가스크로마토그래피/질량분석기를 이용한 식품 중 클로로프로판올 화합물 분석)

  • Kim, Eunju;Park, Sungkug;Choi, Dongmi
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.543-552
    • /
    • 2008
  • This paper described the relatively sensitive and simultaneous analytical method for 3-monochloropropane-1,2-diol (3-MCDP, $C_3H_7ClO_2$, MW. 110) as well as 1,3-dichloropropan-2-ol (1,3-DCP, $C_3H_6Cl_2O$, MW. 128) in various foods. Food samples were homogenized in 5M NaCl solution, mixed with aluminum oxide and eluted with dichloromethane. The extracted chloropropanols were concentrated by rotary evaporator and $N_2$ blow serially were derivatized with HFBA (Heptafluorobutyric anhydride, $C_8F_{14}O_3$, MW. 410) and were determined by GC/MS using isotope dilution method. The characteristic molecular ions at m/z 253, 275, 289, 291, and 453 for HFBA derivatives of 3-MCPD (MW. 502) and 110, 275, and 277 for HFBA derivatives of 1,3-DCP (MW. 325) were chosen in selected ion mode. The method validation data showed sufficiently good properties of LOD (0.003 mg/kg), LOQ (0.010 mg/kg), linearity ($R^2{\geq}0.999$ at 0.010~1.000 mg/kg), and recovery rate (${\approx}97%$). The levels of chloropropanols in soy sauce, sauces, processed meat products, fishery products, and seasonings (n=56/157) determined by the presented method were 0.0~0.3 mg/kg.

Development and Validation of the Determination of Sorafenib in Human Plasma using Tandem Mass Spectrometry Coupled with Liquid Chromatography (고속액체크로마토그래피 텐덤질량분석기법을 이용한 사람 혈장 내 소라페닙 농도분석법의 개발 및 검정)

  • Park, Daejin;Lee, Sunggon;Kim, Woomi
    • Journal of Life Science
    • /
    • v.22 no.11
    • /
    • pp.1456-1462
    • /
    • 2012
  • Sorafenib is a multikinase inhibitor and an oral anticancer drug approved for the treatment of patients with advanced renal cell carcinoma and those with unresectable hepatocellular carcinoma. The purpose of this study was to develop an efficient method of the determination of sorafenib in human plasma using tandem mass spectrometry coupled with liquid chromatography (LC/MS/MS) and validate the method by the guidelines of the Korean Food and Drug Administration (KFDA). Plasma samples ($100{\mu}l$) were added with chlorantraniliprole as an internal standard and then mixed with the 0.1% formic acid-containing extraction solution composed of isopropyl alcohol and ethyl acetate (1:4, v/v). After centrifugation, the supernatant was concentrated at $45^{\circ}C$ under negative pressure and centrifugal force. The residue was reconstituted with a mobile phase and injected into the HPLC instrument using a reverse phase Waters XTerra$^{TM}$ C18 column (particle size $3.5{\mu}m$). Liquid chromatography was carried out within the run time of 5 min using a mobile phase composed of buffer (0.1% formic acid and 10 mM ammonium formate), methanol, and acetonitrile (1:6:3, v/v/v). The analytes were monitored by tandem mass spectrometry in the multiple reaction monitoring method programmed to detect sorafenib at 'm/z 465.2 ${\rightarrow}$ 252.5' and chlorantraniliprole at 'm/z 484.4 ${\rightarrow}$ 286.2' with positive electrospray ionization mode ($ES^+$). The result showed the proper linearity ($r^2$ > 0.99) over the range of 2,000-5,000 ng/ml with good accuracy (90.7-103.9%) and precision (less than 10%). The newly developed method using LC/MS/MS was validated by the guideline of KFDA and identified as more sensitive compared to the previous methods.