• Title/Summary/Keyword: 감쇠 효과

Search Result 632, Processing Time 0.17 seconds

A Simulation of Earthquake Loss Estimation for a Gyeongju Event (경주지역 발생 지진에 대한 지진손실예측 시뮬레이션)

  • Kang, Su-Young;Kim, Kwang-Hee;Suk, Bong-Chool;Yoo, Hai-Soo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.95-103
    • /
    • 2008
  • Knowledge of expected losses in terms of physical, economic, and social damages due to a potential earthquake will be helpful in the effort to mitigate seismic hazards. In this study, losses due to a magnitude 6.7 scenario earthquake in the Gyeongju area have been estimated using the deterministic method in HAZUS. The attenuation relation proposed by Sadigh et al.(1997) for site classes B, C, and D, which are assumed to represent the characteristics of the strong-motion attenuation in the Korean Peninsula, has been applied. Losses due to the hypothetical earthquake have been also calculated using other attenuation relationships to examine their roles in the loss estimation. The findings indicate differences among the estimates based on various attenuation relationships. Estimated losses of the Gyeongju area by a scenario earthquake using HAZUS should be seriously considered in the planning of disaster response and hazard mitigation.

Linear Stability Analysis for Combustion Instability in Solid Propellant Rocket (고체추진 로켓의 선형 안정성 요소에 대한 연구)

  • Kim, Hakchul;Kim, Junseong;Moon, Heejang;Sung, Honggye;Lee, Hunki;Ohm, Wonsuk;Lee, Dohyung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.27-36
    • /
    • 2013
  • Linear stability analysis for combustion instability within a cylindrical port of solid rocket motor has been conducted. The analysis of acoustic energy has been performed by a commercial COMSOL code to obtain the mode function associated to each acoustic mode prior to the calculation of stability alpha. An instability diagnosis based on the linear stability analysis of Culick is performed where special interests have been focused on 5 stability factors(alpha) such as pressure coupling, nozzle damping, particle damping and additionally, flow turning effect and viscous damping to take into account the flow and viscosity effect near the fuel surface. The instability decay characteristics depending on the particle size is also analyzed.

Study of Integrated Optimal Design of Smart Top-Story Isolation and Building Structures in Regions of Low-to-Moderate Seismicity (중약진지역 구조물과 스마트 최상층 면진시스템의 통합최적설계에 대한 연구)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.13-20
    • /
    • 2013
  • In order to reduce seismic responses of a structure, additional dampers and vibration control devices are generally considered. Usually, control performance of additional devices are investigated for optimal design without variation of characteristics of a structure. In this study, multi-objective integrated optimization of structure-smart control device is conducted and possibility of reduction of structural resources of a building structure with smart top-story isolation system has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions. The integrated optimal design method proposed in this study can provide various optimal designs that presents good control performance by appropriately reducing the amount of structural material and damping device.

Seismic Retrofitting of Cabinet Structures in Nuclear Power Plant (원자력 발전소 캐비닛구조물의 내진보강)

  • 이계희;김재민;김상윤
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.31-37
    • /
    • 2003
  • This paper presents the methodologies for seismic retrofitting of cabinet equipment which can be employed to resolve the USI A-46 problem related to seismic qualification of old nuclear power plant. To obtain accurate dynamic characteristics of a cabinet structure, three types of structural modeling are introduced and the their free vibration modes are compared. Three types of seismic retrofitting scenarios, such as 1) the installation of bracing, 2) installation of damper, 3) installation of tuned mass damper(TMD), are established and evaluated for the decrease of ICRS(In Cabinet Reponse Spectrum). In the cases of 1) & 2), since the retrofitted structures show larger ICRS than that of the original structure, the careful considerations are need in the application of these methods. Though the installation of TMD shows the best retrofitting result, the construction of analysis model that indicate the accurate vibration modes of real structure is estimated the essential step of this retrofitting method.

Movable Anchorage System for Mitigation of Cable Vibration in Cable-Stayed Bridges with Sag (Sag가 고려된 사장교 케이블의 진동저감을 위한 Movable Anchorage 시스템)

  • Hwang, Inho;Park, Jun Hyung;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.657-664
    • /
    • 2008
  • Rain-wind induced cable vibration can cause the damages in the cable-stayed bridge due to very little inherent damping characteristics and low fundamental frequency. External Dampers attached to stay cables near anchorages have been shown to be effective means at short stay-cables. However, installation locations of external dampers are limited to a particular range due to aesthetic and practical reasons for very long stay-cables. A recent study by the authors showed that the stay-cable vibration system can perform better than the optimal passive viscous damper, thereby demonstrating its applicability in large cable-stayed bridges. This paper extends the previous study on the taut string representation of the cable by adding cable sag and inclination. The response of the proposed system compared to those of the cable with and without an external damper, and the movable anchorage system provides very effective mitigation of cable vibration. Cable damping ratio is seen to be remarkably reduced by movable anchorage system for a wide range of cable sag. This result shows that the sag effects of the proposed system should be considered.

Performance Investigation of Semi-Active Damper Considering Mass Modeling of Functional Fluid (작동유체 질량을 고려한 유연우주트러스구조물 제진용 반능동 댐퍼의 성능분석)

  • Oh, Hyun-Ung;Choi, Young-Jun;Lee, Kyong-Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.5
    • /
    • pp.450-456
    • /
    • 2009
  • Semi-active vibration control is one of the attractive control methods for space application due to its robustness as passive damping system and much higher damping performance than passive system. In this paper, performance investigation of semi-active damper considering a mass modeling of functional fluid inside of the damper has been performed. Numerical investigation results confirmed that the damper model considering the fluid mass is effective for vibration suppression performance at a relatively low viscosity range of functional fluid. Based on the analysis results, design method to enhance the performance of semi-active damper has been proposed.

Earth Reflection Effect Analysis in the Environment of Line Source Induction (전력선 유도 환경에서의 지면 반사계 영향 분석)

  • Lee, Sangmu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.26-32
    • /
    • 2013
  • The earth reflection effect on the induced voltage by line source such as power line occurring induction inteference is analyzed to scrutinize how much it would reduce the induced voltage. Using hankel transformation including bessel function, directly calculation formulae for extracting a refelction coefficient is a most important technical application in this paper since the reflection coefficient on the earth cannot be deduced by a general coefficient calculation formulae according to a plain wave. The electric field is utilized to transform the electromagnetic field into an induced voltage. The composed efficiency to a source induction voltage by an earth reflection is about a range of 60~70% for the axis constellation of each object like observation point, source position and other material parameters.

Numerical Model on Suspended Load Diffusion due to Tidal Flow (조류(潮流)에 의한 부유사(浮遊砂)의 확산(擴散)에 대한 수치모형(數値模型))

  • Lee, Jong Kyu;Ahn, Soo Hahn
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.13-23
    • /
    • 1984
  • The purpose of this paper is to develop a numerical model which can be used to compute the suspended load concentration of which the two-dimensional unsteady diffusion equation is able to be solved by the finite difference method using the implicit scheme. The pick-up rate formula from the bottom used in the open channel as a sink source term and the Coleman's empirical formula for the diffusion coefficient were taken, and especially the hindered settling velocity and the vertical velocity of flow due to the periodical tidal motion were taken into account, while the effects of the variables, such as the horizontal and vertical velocities of flow, tidal range, the settling velocity and hindered settling, on the suspened load concentrations have been discussed, comparing the results obtained from the different cases in the simulation conditions.

  • PDF

Vibration Control of a Cantilever Beam by Using a Piezoelectric Servo-Damper (압전형 서어보 감쇠기를 이용한 외팔보계의 진동제어)

  • 이상호;지원호;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.169-173
    • /
    • 1991
  • 최근 자동화기술의 발달에 따라 산업용 로보트팔의 경량화, 고속화를 실행하 게 되는 경우와 우주, 원자력발전소 등과 같은 특수한 환경하에서 매니퓰레 이터(manipulator)를 제어하게 되는 경우가 많아지고 있는데, 이때 팔의 강성 이 충분하지 않으면 위치결정시 목표점에서의 과도진동이 발생하게 되어 위 치결정정도와 작업효율이 저하된다. 그러므로 이러한 경량화된 장비들의 진 동특성을 파악하고 운동시 발생하는 진동을 효율적으로 제어할 수 있는 제 어기(controller)를 설계하여 잔류진동을 감쇠시키므로써 위치결정시간을 줄 일 수 있고, 전체 작업행정시간이 단축되므로써 작업ㅎ류을 향상시키는 효과 를 가져오게 된다. 이때 원하고자 하는 제어를 하기 위해서는 제어대상 (plant)의 계규명(system identification)을 정확히 하여야 하는데 해석적으로 계를 규명하기가 까다로운 경우 제어기를 설계하는 것이 사실상 어렵게 되 므로 이러한 경우 실험적인 방법으로 주파수응답함수(frequency response function)를 구해 계의 모형(model)을 구하는 방법이 널리 사용되고 있다. 이 분야에 있어서 기존의 논문들은 팔의 변위를 측정하여 진동을 제어하나 이 러한 방법들은 간헐적으로 움직이는 산업장비(예:로보트의 팔)의 과도응답을 제어하기에는 부적합하다. 따라서 본 연구에서는 이러한 장비들의 과도응답 을 효과적으로 제어할 수 있도록 가속도계를 사용, 가속도를 측정하여 변위 를 제어하고자 한다.

  • PDF

Noise Map Analysis for the Design of Noise Barrier at School Site (학교부지의 방음벽 설계를 위한 소음지도 해석)

  • Yun, Junho;Kim, Wonjin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.232-238
    • /
    • 2012
  • In this study, the noise mapping simulation is executed to design an effective barrier reducing noise levels of a school site. The geographical features of the ambient site and the school buildings are modelled in detail in order to consider sound propagation, deflection, and absorption phenomena etc. The main sound source, sound power level of expressway, is estimated on the basis of measured noise levels at several points of the site. The noise mapping simulation is performed by using ENPro, environmental noise prediction program based on ISO 9613 to analysis the effectiveness of noise barrier. Consequently, the noise barrier is designed to meet an environmental noise standard and satisfy low cost and safety conditions.