Seismic Evaluation of RC Special Shear Wall with Improved Reinforcement Details in Boundary Elements (경계요소의 횡보강근 상세를 개선한 RC 특수전단벽의 내진성능 평가)

  • Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.195-202
    • /
    • 2012
  • This paper summarizes the seismic performance of two shear walls with different reinforcement details in boundary elements. One is a special shear wall designed by KBC2009 and the other is a shear wall with improved reinforcement details in boundary elements, which is a newly proposed type of special shear wall. Experimental tests under cyclic reversed loading were carried out with two 2/3 scale shear walls which were modelled from the lower part of seismic-resisting shear wall in 22-stories wall-slab apartment building. The experimental results show that seismic performance of shear wall with improved reinforcement details was almost similar to that of special shear wall with respect to the moment-drift ratio. However, energy dissipation capacity and ductility were slightly different. Also, shear wall with improved reinforcement details in boundary elements satisfied the inter-story drift limit of 1.5% from KBC2009.

Wavelet Transform Based Doconvolution of Ultrasonic Pulse-Echo Signal (웨이브렛 변환을 이용한 초음파 펄스 에코 신호의 디컨볼루션)

  • Jhang, Kyung-Young;Jang, Hyo-Seong;Park, Byung-Yll;Ha, Job
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.511-520
    • /
    • 2000
  • Ultrasonic pulse echo method comes to be difficult to apply to the multi-layered structure with very thin layer, because the echoes from the top and the bottom of the layer are superimposed. We can easily meet this problem when the silicon chip layer in the semiconductor is inspected by a SAM equipment using fairly low frequency lower than 20MHz by which severe attenuation in the epoxy mold compound of packaging material can be overcome. Conventionally, deconvolution technique has been used for the decomposition of superimposed UT signals, however it has disabilities when the waveform of the transmitted signal is distorted according to the propagation. In this paper, the wavelet transform based deconvolution(WTBD) technique is proposed as a new signal processing method that can decompose the superimposed echo signals with superior performances compared to the conventional deconvolution technique. WTBD method uses the wavelet transform in the pre-stage of deconvolution to extract out the common waveform from the transmitted and received signal with distortion. Performances of the proposed method we shown by through computer simulations using model signal with noise and we demonstrated by through experiments for the fabricated semiconductor sample with partial delamination at the top of silicon chip layer.

  • PDF

On the Removal of Irregular Frequencies in the Prediction of Ship Motion in Waves (파랑중에서 전진동요하는 선박의 특이파수 억제에 관한 연구)

  • H.Y. Lee;D.J. Yum
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.4
    • /
    • pp.73-81
    • /
    • 1994
  • The source and source/dipole distribution methods using 3-dimensional panel method have been widely used for ship motion analysis. When these methods are used, large errors in the predicted hydrodynamic coefficients are introduced around the irregular frequencies caused by the resonance of imaginary internal flow. Therefore, the irregular frequencies need to be removed for an accurate prediction of ship motion. This paper adopts 3-dimensional translating and oscillating Green function derived by Wu. The adaptive integration method, stretching transform and stationary phase method are used for the calculation of the calculation of Green function and the integral equation is derived by distributing the Green function n ship surface and inner free-surface. The condition of zero normal velocity, that is, wall condition on inner free-surface has been successfully used for the removal of irregular frequencies in oscillating problems. The calculations are carried out for series 60($C_B=0.7$) vessel and the results are compared with those of other theoretical analyses and experiment.

  • PDF

Study on Elevator Induced Structural Vibration Reduction Performance Using Polymer Concrete (폴리머 콘크리트를 이용한 엘리베이터 기인 구조 진동저감 성능 연구)

  • Yeom, Jihye;Kim, Jeong-Jin;Park, Junhong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.90-94
    • /
    • 2021
  • With the increased interest on quiescent place for residential place, the noise generation from facilities needs to be minimized. One important noise source include sounds from operation of elevators. The elevator operates between floors and generates significantly annoying sounds to the nearby living spaces. It is recognized as the significant contributor inducing noise annoyance to residents. Elevator is supported to the building structure at several locations for movements between floors. In this study, the vibration reduction by use of polymer concrete on the support location was demonstrated. By measuring and comparing the vibration generation when supported on cement and polymer concrete, the noise reduction performance was evaluated. The polymer concrete was made in the form of being inserted into the wall that imitates the hoistway. The impact vibration was induced to the bracket and vibration transfer magnitude was measured. The damping ratio was evaluated through normalization and curve fitting of transient response, and comparison was performed for each resin mixing ratio. By use of polymer concrete, it was possible to reduce the vibration generation in an effect manner without sacrifice on the structural rigidity.

Performance analysis of CSMA based MAC protocols for underwater communications (수중 통신에 적합한 CSMA기반 매체접근제어 프로토콜 연구)

  • Song, Min-Je;Jang, Youn-Seon
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1068-1072
    • /
    • 2018
  • In underwater communications, there are many challenges due to energy limitations, long propagation delay, low data rate, and high power loss, unlike terrestrial RF communications. Especially, the propagation delay of underwater acoustic channel is five orders of magnitude higher than in electro-magnetic terrestrial channels due to the low speed of sound(1,500m/s). Thus, the MAC protocols for terrestrial communications are not suitable for underwater network. In this paper, we studied the considerations for MAC protocol in underwater acoustic channel. Here, we concentrated on CSMA based MAC protocols. From the results, we confirmed that the number of control packets has an important effect on the performance in underwater environment. These results would be useful in designing MAC protocols for underwater acoustic communications.

Strengthening of Non-ductile Reinforced Concrete (RC) frames with Expansive Joint Mortar and H-beam Frame (팽창형 접합부 모르타르와 H형강 프레임에 의한 비내진 상세를 갖는 철근콘크리트 골조의 내진보강)

  • Kim, Ji-Hyeon;Jang, Seok-Joon;Yun, Da-Ae;Kim, Dae-Young;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.127-135
    • /
    • 2019
  • The seismic performance of non-ductile reinforced concrete (RC) frame retrofitted with H-beam frame and cast expansive mortar into joint between existing RC frame and H-beam frame is investigated experimentally and analytically. RC frames considered in the study contain non-ductile reinforcement details of low-rise school building constructed in Korea before 1988. The tests were conducted on half-scale specimens simulating the lower frame assemblages of a typical school building. Two one-bay, one-story RC frames with and without retrofitting with H-beam frame and expansive joint mortar were tested to failure. Test and analysis results indicated that seismic strengthening using H-beam and expansive joint mortar significantly improved the lateral strength and stiffness of non-ductile RC frame without installing anchor bolts to fit H-beam frame into existing RC frame. The effectiveness of seismic strengthening technology proposed in the study for non-ductile RC frame was verified experimentally and analytically.

A Study on Interference Mitigation Method between S-Band Radars using Band Pass Filter (대역통과 필터를 이용한 S-Band 레이더 간의 간섭 회피방안 연구)

  • Seongjoon Pak;Jaeyeon Kim;Tae-Soon Chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.79-85
    • /
    • 2023
  • To make normal operation of S-Band PSR(Primary Surveillance Radar) which are in operation near distance, Minimizing the mutual frequency interference was studied in this paper. First, the phenomenon of radar receiver was analyzed when the interference between PSR was occurred. And next, the proper S-Band Bandpass filter(BPF) was chosen to deal with the interference. And inhibition performance of BPF was verified by comparative analysis of Radar's RF reception characteristic before and after of BPF application. There is 6.4~7.7 dB passband attenuation when BPF was applied at Radar receiver. So the PSR probability of detection were compared and analyzed to check the radar detection performance was deteriorated or not, And this result proved the usefulness of this study.

Development and applicability study of customized porcelain packaging technology using 3D printed TPU material (TPU 소재 3D 출력물을 이용한 도자기 맞춤형 포장 기술 개발 및 적용성 연구)

  • Oh Seungjun
    • Conservation Science in Museum
    • /
    • v.31
    • /
    • pp.39-54
    • /
    • 2024
  • We wanted to check The feasibility of substituting the manual ceramic packaging technology with 3D digital technology using cotton pad packaging material was examined. To examine the shock absorption, vibration resistance and compression resistance of 3D packaging material printed out by using TPU material, composite vibration, and packaging compression and drop tests were conducted. As the results of the tests, the 3D packaging material displayed vibration resistance that has been improved by approximately 10~20% based on the damping ratio of the composite vibration test, compression resistance performances that are more than 5 times higher, and shock absorption performance was also improved as the packaged object was not broken in the six-sided drop test. Based on these results, it is determined that it would be possible to secure the reusability of the ceramic packaging materials and simplify packaging techniques, and to present diversity in the packaging materials and packaging technologies.

Evaluation of Seakeeping Performance of an Light Aircraft Carrier (경항모 내항성능 평가 연구)

  • Dong-Min Park;Min-Guk Seo;Hyungdo Song;Seok-Kyu Cho;Sa Young Hong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.61 no.5
    • /
    • pp.297-311
    • /
    • 2024
  • In this study, a combined seakeeping performance evaluation method has been developed for the design purpose of the light aircraft carrier CVX of Korean Navy. A frequency domain analysis method was developed for evaluation of safe operating envelope up to sea state 6, while a time domain analysis method was developed for survival condition of sea state 7 and higher. The frequency-domain solver AdFLOW-Navy was developed by adding empirical formula of roll damping and fin-stabilizer to the existing AdFLOW by KRISO, which was based on the three-dimensional higher order boundary element method (HOBEM). For the estimation of the roll damping coefficient, a two-dimensional cross-section was automatically extracted from the three-dimensional panel, and the roll damping coefficient was analyzed for the two-dimensional cross-section. As for the time domain analysis method, KIMAPS-Navy was developed by improving and expanding the KIMAPS series developed by KRISO which is based on the impulse response function by utilizing the hydrodynamic coefficients obtained from the AdFLOW-Navy. In addition, a weakly nonlinear analysis approach was applied to analyze highly nonlinear motion under heavy sea states. Finally numeraical analysis results were compared with model tests, which showed practical usefulness of the present combined seakeeping analysis approach.

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.