• Title/Summary/Keyword: 감마-선

Search Result 1,495, Processing Time 0.032 seconds

Effects of $^{60}Co-gamma$ Radiation on Ricebran Oil (미강유에 대한 코발트 60-감마선의 영향에 관한 연구)

  • Han, Deok-Bong;Suck, Han-Gyun;Yoo, Young-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.129-135
    • /
    • 1973
  • The accumulation of peroxides, acid values, and carbonyl values during irradiation and post-irradiation storage of the ricebran oil has been studied. The rice bran oils were irradiated two doses of 2 and 7 megarads (300 rads/sec) at $23^{\circ}C$ atmospheric circumstance. The acid values, peroxide values and carbonyl values were measured at regular intervals of one week during the storage at $5^{\circ}C$ and $25^{\circ}C$. 1) During the storage, the acid values of the irradiated rice bran oils increased or decreased insignificantly regardless of the addition of antioxidants and storage temperature. 2) The peroxide values were not increased continuously but increased zigzag. The result was indicated that the composition and decomposition of peroxides occurred continuously throughout the storage. 3) As the peroxide values increased, carbonyl values decreased and changed quite differently, but, especially in 7th week, they were constant or insignificant. 4) Dibutylhydroxytoluene is more effective than caffeic acid in retarding the formation of peroxides during irradiation of rice bran oils and post-irradiation storage. The effect of antioxidant is more efficient at 2 megarads than at 7 megarads irradiation. When we store the rice bran oil, the addition of antioxidants of post-irradiation is more desirable than that of preirradiation. 5) In spite of changing conditions such as storage temperature and addition of antioxidants, the peroxide values of rice bran oils irradiated at 2 megarads were always greater than those at 7 megarads during the storage. Peroxide values of samples at high temperature $(25^{\circ}C)$ storage increased as twice as those of low temperature $(5^{\circ}C)$ storage samples. At low temperature, peroxide values in the first week increased twice during the period of 8th weeks storage, but those did from three to four times at higher temperature in the same period Therefore, the low temperature storage is recommandable too.

  • PDF

The Patient Specific QA of IMRT and VMAT Through the AAPM Task Group Report 119 (AAPM TG-119 보고서를 통한 세기조절방사선치료(IMRT)와 부피적세기조절회전치료(VMAT)의 치료 전 환자별 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Kim, Jong-Ha;Park, Seung;Lee, Keun-Sub;Sohn, Seung-Chang;Shin, Young-Joo;Kim, Yon-Lae
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.255-263
    • /
    • 2012
  • The aim of this study was to evaluate the patient specific quality assurance (QA) results of intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) through the AAPM Task Group Report 119. Using the treatment planning system, both IMRT and VMAT treatment plans were established. The absolute dose and relative dose for the target and OAR were measured by using an ion chamber and the bi-planar diode array, respectively. The plan evaluation was used by the Dose volume histogram (DVH) and the dose verification was implemented by compare the measured value with the calculated value. For the evaluation of plan, in case of prostate, both IMRT and VMAT were closed the goal of target and OARs. In case of H&N and Multi-target, IMRT was not reached the goal of target, but VMAT was reached the goal of target and OARs. In case of C-shape(easy), both were reached the goal of target and OARs. In case of C-shape(hard), both were reached the goal of target but not reached the goal of OARs. For the evaluation of absolute dose, in case of IMRT, the mean of relative error (%) between measured and calculated value was $1.24{\pm}2.06%$ and $1.4{\pm}2.9%$ for target and OAR, respectively. The confidence limits were 3.65% and 4.39% for target and OAR, respectively. In case of VMAT the mean of relative error was $2.06{\pm}0.64%$ and $2.21{\pm}0.74%$ for target and OAR, respectively. The confidence limits were 4.09% and 3.04% for target and OAR, respectively. For the evaluation of relative dose, in case of IMRT, the average percentage of passing gamma criteria (3mm/3%) were $98.3{\pm}1.5%$ and the confidence limits were 3.78%. In case of VMAT, the average percentage were $98.2{\pm}1.1%$ and the confidence limits were 3.95%. We performed IMRT and VMAT patient specific QA using TG-119 based procedure, all analyzed results were satisfied with acceptance criteria based on TG-119. So, the IMRT and VMAT of our institution was confirmed the accuracy.

Preliminary Investigations of the Dosimetric Properties of a Normoxic Polymethacrylic Acid Gel Dosimeter Using a Respiration-Motion Simulator (호흡모의움직임장치를 이용한 정상산소 폴리메타크릴산 겔 선량계의 선량특성)

  • Park, Chae Hee;Cho, Yu Ra;Cho, Kwang Hwan;Park, Ji Ae;Kim, Kyeong Min;Kim, Kum Bae;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.138-144
    • /
    • 2012
  • Dose distribution throughout the clinical organ range of motion was analyzed using a respiratory-motion simulator that was equipped with a polymer gel dosimeter and EBT2 film. The normoxic polymer gel dosimeter was synthesized from gelatin, MAA, HQ, THPC and HPLC. The gel dosimeter and EBT2 film were irradiated with Co-60 gamma rays that were moved along the x-axis and y-axis in ${\pm}1.5cm$ steps at five-second intervals. The field size was $5{\times}5cm^2$. The SSD was 80 cm and set to 10 Gy at a depth of 2 cm. The PDD at a depth of 50 mm was 75.2% in the ion chamber, 82.3% in the static state and 86.1% in the dynamic state in the gel dosimeter. The penumbra for the dynamic state target, which was measured using the gel dosimeter, averaged 10.89 mm, this is a 40.5% increase over the penumbra of the static state target of 7.74 mm. In addition, when measuring with gel dosimetry, the value for the penumbra is 36.6% smaller in the static state and 29.4% smaller in the dynamic state compared to measuring with film. The aim of this study was to investigate the dosimetric properties of a normoxic polymethacrylic acid gel dosimeter in static and dynamic states and to evaluate the potentiality as a relative dosimeter for dynamic therapeutic radiation.

Cloning and Characterization of a 5-Enolpyruvyl Shikimate 3-Phosphate Synthase (EPSPS) Gene from Korean Lawn Grass (Zoysia japonica) (들잔디 5-Enolpyruvyl Shikimate 3-Phosphate Synthase(EPSPS) 유전자 클로닝 및 특성)

  • Lee, Hye-Jung;Lee, Geung-Joo;Kim, Dong-Sub;Kim, Jin-Beak;Ku, Ja-Hyeong;Kang, Si-Yong
    • Horticultural Science & Technology
    • /
    • v.28 no.4
    • /
    • pp.648-655
    • /
    • 2010
  • This study is the first comprehensive report on the molecular cloning, structural characterization, sequence comparison between wild and mutant types, copy number in the genome, expression features and activities of a gene encoding 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS) in Korean lawn grass ($Zoysia$ $japonica$). The full length cDNA of the EPSPS from Korean lawn grass ($zj$EPSPS) obtained from a 3' and 5' RACE method was 1540 bp, containing a 1176 bp ORF, a 144 bp leader sequence (5' UTR) and a 220 bp 3' UTR, which was eventually decoded 391 amino acid residues with a molecular mass of 41.74 kDa. The Southern blot detection of the $zj$EPSPS showed that the gene exists as a single copy in the Korean lawn grass genome. Sequence comparison of the $zj$EPSPS gene demonstrated that the glyphosate-tolerant mutant (GT) having a Pro-53 to Ser substitution in the gene seems to have a preferred binding activity of the enzyme to phosphoenol pyruvate(PEP) over glyphosate, which allows the continuous synthesis of aromatic amino acids in the shikimate pathway. From the Northern blotting analysis, the $zj$EPSPS was found to be highly expressed, with continuous increase until 36 hours after 0.5% glyphosate treatment in both wild and mutant samples, but 1.5-fold higher EPSP synthase activity was observed in the tolerant mutant when exposed to the glyphosate treatment. The molecular information of the $zj$EPSPS gene obtained from this study needs to be further dissected to be more effectively applied to the development of gene-specific DNA markers and zoysiagrass cultivars; nevertheless, the glyphosate-tolerant mutant having the featured $zj$EPSPS gene can be provided to turfgrass managers for weed problems with timely adoptable management options.

Effect of Gamma Irradiation and Cichorium Products on Oxidative Damage and Lipid Metabolism in Streptozotocin-Induced Diabetic Rats (감마선 전신 조사와 치커리 가공물 식이가 Streptozotocin 유발 당뇨쥐의 산화적 손상과 지질대사에 미치는 영향)

  • Woo, Hyun-Jung;Kim, Ji-Hyang;Kim, Jin-Kyu;Kim, Hee-Jung;Park, Ki-Beom
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.2 s.62
    • /
    • pp.102-111
    • /
    • 2006
  • The increased occurrence of hyperglycemia and oxidative stress in streptozotocin (STZ) induced type I diabetes has been implicated in the etiology and pathology of disease complication. STZ has known to be genotoxic in a variety of assays including tests for microbial mutagenesis and unscheduled DNA synthesis in rat kidney. Diabetes mellitus (DM) is a pathologic condition, resulting in severe metabolic imbalances and non-physiologic changes in many tissues. We examined the effect of gamma radiation and KWNP on preventing the development of insulin dependent diabetes mellitus using streptozotocin-induced Fisher 344 diabetic rats. The hematological values (red blood cell and white blood cell), serum biochemical constituents-alkaline phosphatase (ALP), total cholesterol, triglycerides and insulin-were checked and the organs (testis, spleen and kidney) were weighed. The gonad indices of the STZ treated groups were much lower than the value of the control group. But the gonad indices of the KWNP treated groups were higher than those of the treated groups. The ratio of the weight of kidney to the body weight of the STZ treated groups was higher than that of the control group. The value of the diabetic group treated with KWNP after irradiation (F group) was lower than the other STZ treated groups. The white blood cell and ALP values of the F group were lower than the other STZ groups, as well. The cholesterol and triglyceride values of all the KWNP treated groups were significantly lower than the other groups. A significant increase (about 10 times) of insulin was detected in the F group. The results of hematological assay showed the distinctive damage in the irradiated and STZ treated groups. The quantity of apoptotic cells in seminiferous tubule of testis confirmed a serious damage as assessed in the STZ treated groups. These experimental results have revealed that treatment of the products of KWNP after irradiation has the antidiabetic effect in the STZ-induced diabetic rats. But the F group showed higher recuperative power. These experimental results have revealed that treatment of the gamma irradiation and KWNP have the recovering effect in the STZ-induced diabetic rats.

Microbial Growth in Dried Fishes During Preservation (건어물 저장 중 미생물 증식상태에 관한 연구)

  • 이현자;김종군;이수정;조한옥
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.3
    • /
    • pp.135-140
    • /
    • 1993
  • Dried fishes such as dried pollack, dried sliced squid, dried white bait, dried anchoy) and dried cod used to cook Korean traditional foods were airpacked in polyethylene tube and irradiated with 7 kGy of gamma-ray source. The effect of gamma irradiation on microbial growth in dried fishes was investigated during storage at ambient temperature for 12 months. The total aerobic bacteria in the control group were contaminated by $3.9{\times}10^{3}\;cells/g$ in dried pollack, $5.6{\times}10^{5}\;cells/g$ in dried sliced squid, $1.2{\times}10^{5}\;cells/g$ in dried white bait, $1.2{\times}10^{4}\;cells/g$ in dried anchovy and $1.2{\times}10^{4}\;cells/g$ in dried cod and 7 kGy irradiation could eliminate the bacteria and also reduce aerobic bacterial load to 1~3 log cycle and no apparent growth of microorganisms occurred during storage. Molds in the control group were contaminated by $4.0{\times}10^{2}\;cells/g$ in dried pollack, $$1.3{\times}10^{2}\;cells/g$ in dried sliced squid, $2.5{\times}10^{2}\;cells/g$ in dried white bait, 90 cells/g in dried anchovy and $2.0{\times}10^{2}\;cells/g$ in dried cod, respectively. 7 kGy irradiation could sterilize the molds and the growth of molds of nonirradiated samples were slightly decreased during storage. Yeasts in the control group were contaminated by $1.4{\times}10^{3}\;cells/g$ in dried poUack, 75 cells/g in dried sliced squid, $1.1{\times}10^{3}\;cells/g$ in dried white bait, 50 cells/g in dried anchovy, $1.6{\times}10^{2}\;cells/g$ in dried cod, respectively and irradiation could sterilize the yeasts and growth of yeasts was slightly decreased in dried pollack and dried white bait but increased in order of dried anchovy, dried cod and dried sliced squid. Coliforms in all sample were sterilized by irradiation and its growth was decreased during storage except dried anchovy.

  • PDF

A Study of Radiation Exposure in Proton Therapy Facility (양성자치료기 가속기 시설에서의 작업종사자의 방사선 피폭 연구)

  • Lee, Sang-Hoon;Shin, Dong-Ho;Yoon, Myong-Geun;Shin, Jung-Wook;Rah, Jeong-Eun;Kwak, Jung-Won;Park, Sung-Yong;Shin, Kyung-Hwan;Lee, Doo-Hyun;Ahn, Sung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Proton therapy facility, which is recently installed at National Cancer Center in Korea, generally produces a large amount of radiation near cyclotron due to the secondary particles and radioisotopes caused by collision between proton and nearby materials during the acceleration. Although the level of radiation by radioisotope decreases in length of time, radiation exposure problem still exists since workers are easily exposed by a low level of radiation for a long time due to their job assignment for maintenance or repair of the proton facility. In this paper, the working environment near cyclotron, where the highest radiation exposure is expected, was studied by measuring the degree of radiation and its duration for an appropriate level of protective action guide. To do this, we measured the radiation change in the graphite based energy degrader, the efficiency of transmitted beam and relative activation degree of the transmission beam line. The results showed that while the level of radiation exposure around cyclotron and beam line during the operation is much higher than the other radiation therapy facilities, the radiation exposure rate per year is under the limit recommended by the law showing 1~3 mSv/year.

  • PDF

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

Comparison of Radiation Adaptive Responses in Peripheral Lymphocytes of Patients Undergoing Tc-99m MDP and Tc-99m DTPA Scintigraphies (Tc-99m MDP와 Tc-99m DTPA 신티그라피를 시행한 환자의 말초혈액 림프구에서 유도되는 방사선 적응반응의 비교)

  • Bom, Hee-Seung;Li, Ming-Hao;Min, Jung-Jun;Kwon, An-Sung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.252-259
    • /
    • 2000
  • Purpose: The purpose of this study was to compare the radiation adaptive response (RAR) in peripheral lymphocytes (PL) of patients induced by Tc-99m MDP and Tc-99m DTPA scintigraphies. Materials and Methods: Lymphocytes from 45 patients (25 males, 20 females, mean age $44{\pm}18$ years) were collected before and after scintigraphies using 740 MBq Tc-99m MDP (n=22) or Tc-99m DTPA (n=23). Lymphocytes from 20 controls (12 males, 8 females, mean age $43{\pm}7$ years) were also collected. They were exposed to challenge dose of 2 Gy ${\gamma}-rays$ using a Cs-137 cell irradiator Number of ring-form (R) and dicentric (D) chromosomes was counted under the light microscope. From them a representative score, Ydr, was calculated as Ydr=(D+R)/cells. Adaptation index (AI) was defined as difference of Ydr between unconditioned and conditioned lymphocytes. Ydr was also measured after an administration of cycloheximide (CHM), a protein synthesis inhibitor, before challenge dose. Results: RAR was induced in both groups of patients. CHM abolished the adaptive response in both groups. AI of Tc-99m MDP group was significantly higher than that of Tc-99m BTPA group. Conclusion: Tc-99m MDP induced RAR was more prominent than those induced by Tc-99m DTPA.

  • PDF

Study of 188Re(V)-DMSA for Treatment of Cancer: Radiolabeling and Biodistribution (암 치료를 위한 188Re(V)-DMSA에 관한 연구: 방사성동위원소 표지와 생체내 분포)

  • Kim, Young Ju;Jeong, Jae Min;Chang, Young Soo;Lee, Dong Soo;Chung, June-Key;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.81-88
    • /
    • 1998
  • The purpose of this study was to examine the radiolabeling and biodistribution of $^{188}Re(V)$-DMSA as a therapeutic cancer radiopharmaceutical. We made a DMSA kit($NaHCO_3$ 1.5 mg, meso-2,3-dimercaptosuccinic acid 1.0 mg, L(+)-ascorbic acid 0.7 mg, $SnCl_2{\cdot}2H_2O$ 0.34 mg, pH 2.9) for labeling with $^{188}Re$. In this kit, $^{188}ReO_4{^-}$ 5 mCi/2 ml added and boiled at $100^{\circ}C$ for 3 hr in water bath. The final pH adjusted to 7.5 with 7% $NaHCO_3$ solution. We checked the labelling efficacy with TLC-SG(n-butanol : acetic acid : $H_2O$ = 3 : 2 : 3) and examined the stability both in room temperature and in serum at $37^{\circ}C$. Biodistribution(1, 3, 13, 24, 48 hr) of $^{188}Re(V)$-DMSA compound was evaluated in Sarcoma 180 tumor-bearing mice. Each labeling efficiency and stability at room temperature for 48 hours was over 98% and 95%, respectively. The stability in serum were 82%(6 hr) and 85%(48 hr). Tumor uptake of $^{188}Re(V)$-DMSA in Sarcoma 180-bearing mice were $0.66{\pm}0.15%$(1 hr), $0.51{\pm}0.10%$(3 hr), $0.19{\pm}0.05%$(24 hr) and $0.13{\pm}0.02%$(48 hr). These result are consistent with those of $^{99m}Tc(V)$-DMSA which were reported previously. In conclusion, $^{188}Re(V)$-DMSA may be a useful therapeutic radiopharmaceutical for treating some cancers and metastatic bone lesion.

  • PDF