• Title/Summary/Keyword: 감마 분석법

Search Result 157, Processing Time 0.029 seconds

Application of Immunoassay for the Detection of Gamma-Irradiated Shrimp (감마선 조사된 새우의 검지를 위한 면역분석법의 적용)

  • 이주운;육홍선;조경환;차보숙;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.4
    • /
    • pp.600-604
    • /
    • 2001
  • Immunoassay was used to study the detection method of irradiated shrimp. Sandwich ELISA was formatted with monoclonal antibody (Ab) (M-IgG) and polyclonal Abs (P-IgG) and polyclonal Abs (P-IgG) individually produced against brown shrimp tropomyosin (TPM) as an antigen. When M-IgG was used as a coating Ab to capture TPM, and P-IgG were used as reaction Ab against captured TPM could be detected in the range of 12.5 to 50 $\mu\textrm{g}$/mL. Detected concentrations of TPM from irradiated shrimp decreased dose-dependently, and the concentration of Ag by combination of irradiation with heating or freezing treatments also decreased. This results suggests the possibility for Sandwich ELISA, one of immunological analyses, to be applied for detecting irradiated shrimp.

  • PDF

고순도게르마늄(HPGe) 검출기를 이용한 방사성폐기물 드럼의 핵종농도 평가

  • 박경록;강덕원
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11b
    • /
    • pp.583-589
    • /
    • 1996
  • 원자력발전소에서 발생되는 방사성폐기물들은 폐기물형태 및 방사능 농도가 다양하며 영구처분장으로 이송전까지는 발전소내의 임시 저장고에 안전하게 보관, 관리하고 있다. 생성된 폐기물드럼내에는 감마방출핵종을 비롯하여 알파 및 베타방출 핵종들이 균질 또는 비균질하게 존재하고 있으며 방사능의 세기나 폐기물의 특성에 따라 안정화시키거나 압축처리하여 드럼에 담겨져 있기 때문에 일반적인 파괴분석에 의한 화학분석법으로는 작업자의 피폭, 시료의 대표성 선정 및 장시간의 화학처리 시간소요 등으로 핵종분석이 곤란하다. 따라서 본 논문은 일반적으로 감마핵종분석시 흔히 사용하고 있는 고순도게르마늄(HPGe) 검출기를 이용하여 드럼의 감마핵종농도를 분석하는 방법과 장치의 개발에 대해 언급하였으며 알파나 베타핵종과 같이 직접 분석이 곤란한 핵종들은 각 폐기물드럼내에 존재하는 Co-60이나 Cs-137과의 상관관계를 미리 예측한 척도인자 (scaling factor)를 이용하여 간접적으로 구하는 방법을 사용하고 있으나 본 논문에서는 드럼으로부터 감마핵종만을 분석하는 방법에 대해서만 언급하였다. 또한 핵종분석시스템의 최적 운전조건을 도출하기 위해 드럼회전테이블의 속도결정 및 모의드럼을 이용한 방사능측정 등을 통해 핵종 농도 분석시의 오차를 30% 이내로 유지할 수 있었다.

  • PDF

감마분광법에 의한 핵물질 계량기술 개발

  • 양한범;임재관;김성현;유재형;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.835-840
    • /
    • 1995
  • 핵물질의 화학적분리 및 정제를 위한 용매추출실험의 농도분석에 사용될 수 있는 감마방사능 계측장치를 제작하고 기계적 성능 및 원격작동 시험을 하였다. 계측장치의 모든 구동부분은 공압으로 작동되며 우라늄시료를 분석한 결과 0∼250g/L의 농도범위에서 방사능세기와 일정한 상관관계를 나타내었다.

  • PDF

신뢰도분석을 위한 감마사전확률분포의 추정

  • 전치혁;박영신;김지수
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1993.04a
    • /
    • pp.294-300
    • /
    • 1993
  • 어떤 무기체계의 임무신뢰도분석에 베이지안기법을 사용하는데 있어 고장율이 주어졌을 때 고장간 시간이 지수분포를 따른다는 가정하에 이의 Conjugate Prior인 감마분포의 추정문제를 다룬다. 임무별 고장간시간에 대한 예측분포를 유도하였으며, 실제 측정된 기존의 임무별 고장간시간이 이 예측분포를 따른다는 전제하에 비선형 최소자승법을 이용하여 감마분포의 두 파라메터를 추정하는 방안을 제시하였다. 또한 대상 무기체계의 실제 고장자료를 이용하여 추정치를 구하였다.

  • PDF

Effect of Gamma Irradiation for Hygienic Long-Term Storage on Biological Activity of Teucrium veronicoides (위생적인 장기 보존을 위한 감마선 조사가 곽향(Teucrium veronicoides)의 생리활성에 미치는 영향)

  • Park, Hye-Jin;Park, Ki-Tae;Cho, Young-Je
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.5
    • /
    • pp.581-591
    • /
    • 2017
  • The purpose of this study was to examine the biological activities of gamma-irradiated Teucrium veronicoides. In photostimulated luminescence analysis, non-irradiated sample showed lower than 700 photon counts (PCs), whereas irradiated (5 and 10 kGy) samples showed higher than 700 PCs. The thermoluminescence ratio of non-irradiated samples was less than 0.1, whereas the values of irradiated samples were greater than 0.1. Electron spin resonance analysis was performed confirmed for irradiation identification. The total phenolic contents of hot-water and 50% ethanol extracts were higher than those values after irradiation at 10 kGy. Regarding 1,1-diphenyl-2-picrylhydrazyl radical inhibitory activity, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) radical scavenging activity, antioxidant protection factor, thiobarbituric acid reactive substance inhibitory activity as antioxidant test and xanthine oxidase inhibitory activity, the effect of gamma irradiation had on significant effects. On the other hand, ${\alpha}-amylase$ inhibitory activity of 10 kGy-irradiated hot-water extract was 23.6% higher than that of the non-irradiated sample. Thus, gamma irradiation could be used for the long-term storage of Teucrium veronicoides.

Performance Test of the Ultralow Background Gamma-Ray Measurement System (극저준위 백그라운드 감마선 측정시스템의 성능시험)

  • Na, Won-Woo;Lee, Young-Gil
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.219-226
    • /
    • 1997
  • Ultralow background gamma-ray measurement system was installed to measure and analyze gamma-rays emitted from environmental and swipe samples. The background reduction techniques applied on this system are the passive shielding to surround the HPGe detector, an active external anticosmic shield to shield cosmic-rays and the nitrogen gas supply to minimize the introduction of ubiquitous radon decay nuclei. The performance test result showed that the system background at energies between 50 keV and 2 MeV is reduced about $10^{-2}$ order and the MDA is so low as to be suitable for the environmental sample analysis. But it is appeared that the neutron produced by cosmic-ray increases the background at low energy region.

  • PDF

Synthetic risk management over risk of financial assets (금융자산의 위험에 관한 종합적 위험관리)

  • Kim, JongKwon
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.1
    • /
    • pp.59-75
    • /
    • 2000
  • 최근의 추세를 볼 때 위험관리에 관한 중요성이 점점 증대하고 있다. 그럼에도 불구하고 우리나라 은행들의 위험관리 실태는 아직 미흡한 실정이다. 그리고 대부분의 은행들이 현재 위험관리에 대응하기 위하여 ALM의 갭관리, 듀레이션관리 등을 행하고 있지만 BIS에서 중요시하고 있는 VaR의 개발과 운용은 아직 초보단계에 있다. 한국 주식포트폴리오에서 몬테카를로 시뮬레이션과 Full Variance Covariance Model의 VaR값은 비슷한 수준으로 Diagonal Model 의 VaR값 보다 작음을 알 수 있다. 이는 좀 더 정교한 계산이 요구되는 Full Variance Covariance Model의 VaR값이 보다 단순한 Diagonal Model의 VaR값 보다 정확성면에서 우수하다는 것을 보여주고 있다. 한편 이자율포트폴리오 의 경우에는 델타-감마 분석법과 몬테카를로 시뮬레이션의 경우 95% 신뢰구간의 VaR는 델타-감마 분석법이 작지만 99% 신뢰구간에서의 VaR는 몬테카를로 시뮬레이션방법이 작다는 것을 알 수 있다. 그래서 어느 한 가지 방법에 의한 VaR추정치가 가장 좋은 것이라고 단정하기 어려움을 알 수 있었다.

  • PDF

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.