• Title/Summary/Keyword: 감마지표

Search Result 86, Processing Time 0.028 seconds

Evaluation of the Utility of a Volumetric Modulated Arc Therapy Specific Patient Quality Assurance using Software-based Quality Assurance System (소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Kwon, Kyung-Tae
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • The purpose of this study is to evaluate the usefulness of a software-based quality assurance system based on Volumetric Modulated Arc Therapy treatment plan. Evaluate treatment plan through the D VH analysis, PTV mean dose ($D_{mean}$) and PTV 95% dose($D_{95}$) compare the MFX based on original treatment plan, Average error rate was $0.9{\pm}0.6%$, $1.0{\pm}0.8%$, respectively. Measuring point dose using phantom and ion chamber, the average error rate between the ionization chamber and MFX was $0.9{\pm}0.7%$, $1.1{\pm}0.7%$ (high dose region), $1.1{\pm}0.9%$, $1.2{\pm}0.7%$ (low dose region). The average gamma though of MFX and $Delta^{4PT}$ is $98.7{\pm}1.2%$, $98.4{\pm}.3%$, respectively. Through this study, A software based QA system that simplifies hardware based QA procedures that involve a lot of time and effort. It can be used as a simple and useful tool in clinical practice.

Failure Pattern of Pineal and Ectopic Pineal Germ Cell Tumor after Gamma Knife Radiosurgery (송과선 및 이소성 송과선 생식세포종의 감마 나이프 수술 후 재발 양상)

  • Cho, Heung-Lae;Sohn, Seung-Chang
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.92-100
    • /
    • 2000
  • Purpose :This study was performed to determine the optimal treatment velum of Patients treating with radiation therapy for intracranial germ cell tumor. Materials and Methods : From 1993 to 1998, 19 patients with intracranial germ cell tumors treated by gamma knife radiosurgery were analyzed. The location of tumor was as follows; 9 cases on pineal region, 1 case on suprasellar region, and 9 cases of multiple lesion. 7 patients were pathologically verified; 5 cases of germ cell tumor and 2 cases of non germinomatous germ cell tumor. Tumor volume was ranged from 2.4 cm$^{3}$ to 74 cm$^{3}$. Irradiation dose was 10 Gy to 20 Gy with 50% isodose curve. Follow up period was 10 months to 54 months. Results : Recurrences were observed in 14 cases among 19 (74%) patients. Complete remission and partial remission were achieved in 2 (11%) and 10 (53%) respectively. No response was observed in 7 (36%). 2 cases were recurred within original tumor bed. 6 cases were recurred beyond but contiguous with tumor bed. Ventricular relapses separated from pretreatment tumor bed were 3. Spinal recurrences were 4. Among 8 recurred cases of which tumor volume is smaller than 20 cm$^{3}$, 2 were recurred within original tumor bed, 4 were recurred beyond but contiguous with tumor bed, and 1 spinal recurrence. Meanwhile, 6 cases of which tumor volume larger than 20 cm3, 1 case was recurred beyond but contiguous with tumorbed, 2 ventricular recurrences separated with original tumor bed, and 3 spinal recurrences. 5 cases which did not show any recurrence sign showed characteristics of single lesion, tumor volume smaller than 20 cm$^{3}$ and normal tumor marker. All of 4 cases of spinal recurrences happened in the case having ventricular invasion or lesion. Among 9 cases having multiple lesion, only 3 cases recurred within original tumor bed or around tumor bed, the other 6 cases recurred separated from pretreatment tumor bed. Conclusion : Gamma knife radiosurgery is not recommended for the treatment of intracranial germ cell tumor. It is because of small treatment volume and inadequate radiation dose that are characteristics of gamma knife radiosurgery. Tumor volume, ventricular invasion or ventricular lesion in multiple lesion are important factors to be considered for the wide field radiation therapy Tumor volume smaller than 20 cm$^{3}$, single lesion, no ventricular lesion or invasion, and normal tumor marker are ideal indications for small involved field radiation therapy. Prophylactic spinal irradiation seems to be necessary when there is ventricular lesion, ventricular invasion, and multiple lesions. When the tumor volume is larger than 20 cm$^{3}$, multiple lesions, abnormal tumor marker, and whole ventricular irradiation or partial brain irradiation would be possible and neoadjuvant chemotherapy would be most beneficial in these group.

  • PDF

Analysis of Dose Distribution on Critical Organs for Radiosurgery with CyberKnife Real-Time Tumor Tracking System (사이버나이프 실시간 종양추적 시스템을 이용한 방사선수술 시 주요 장기의 선량분포 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Ji, Young-Hoon;Kim, Kum-Bae;Lee, Sang-Hoon;Choi, Jin-Ho;Lee, Re-Na;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • We measured the dose distribution for spinal cord and tumor using Gafchromic film, applying 3D and 4D-Treatment Planning for lung tumor within the phantom. A measured dose distribution was compared with a calculated dose distribution generated from 3D radiation treatment planning and 4D radiation treatment planning system. The agreement of the dose distribution in tumor for 3D and 4D treatment planning was 90.6%, 97.64% using gamma index computed for a distance to agreement of 1 mm and a dose difference of 3%. However, a gamma agreement index of 3% dose difference tolerence of and 2 mm distance to agreement, the accordance of the dose distribution around cord for 3D and 4D radiation treatment planning was 57.13%, 90.4%. There are significant differences between a calculated dose and a measured dose for 3D radiation treatment planning, no significant differences for 4D treatment planning. The results provide the effectiveness of the 4D treatment planning as compared to 3D. We suggest that the 4-dimensional treatment planning should be considered in the case where such equipments as Cyberknife with the real time tracking system are used to treat the tumors in the moving organ.

  • PDF

Adaptive Response Induced by Low Dose Ionizing Radiation in Human Lymphocytes (인체 말초 혈액 림프구에서 저선량 방사선 조사에 의해 유도되는 적응 반응)

  • Kim, Jeong-Hee;Lee, Kyung-Jong;Cho, Chul-Koo;Yoo, Seong-Yul;Kim, Tae-Hwan;Kim, Sung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.97-102
    • /
    • 1995
  • Adaptive response induced by low dose ${\gamma}-ray$ irradiation in human peripheral lymphocytes was examimed. Human lymphocytes were exposured to low dose of ${\gamma}-ray$ (priming dose, 0.01Gy) followed by high dose (challenging dose, 1.5Gy) after various time intervals (4, 7, 20 hours). Frequencies of micronuclei were enumerated in both primed and unprimed groups. Maximum reduction in frequency of micronuclei was observed when challenging dose irradiation was followed by priming dose after 4hr incubation period. When challenging doses were irradiated 7 or 20hr after priming dose, frequencies of micronuclei were reduced slighty. However, these reduction were not statistically significant. In this study, human peripheral lymphocytes were irradiated at Go phase and they showed adaptive response induced by low dose radiation. Since micronucleus assay is relatively simpler and faster than other methods, it may be a good tool for evaluating radiation-induced adaptive responses.

  • PDF

Applicability of Geophyscal Well Logging in the Assessment of Seawater Intrusion (임해지역 해수침투 평가를 위한 물리검층의 적용성)

  • Lee Sang-Gyu;Hwang Sae-Ho;Hwang Hak-Su;Park In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.3
    • /
    • pp.101-111
    • /
    • 2000
  • In order to assess the seawater intrusion, induction, temperature and conductivity of fluid, and natural gamma logs were obtained in nine wells at the three study areas having different hydrogeologic characteristics. Besides surface geophysical exploration, supplementary geophysical well logs were carried out to understand the hydrogeological characteristics related to the seawater intrusion in the study areas. The geophysical well logs have been proved to increase the accuracy of interpretation of the surface geophyscial exploration's data for assessment of seawater intrusion, and to get the optimum depth for a long monitoring of groundwater. They, also, revealed that the identification of hydrogeological units for strata's porosity was able to be achieved and were illustrated the applicability of geophysical well logs monitoring. Finally, geophysical well logs are expected to play to get the more quantitative information of seawater infusion, if it is fully collaborated with a better method that is strata's resistivity determination with not relatively much effected by seawater within the drilled borehole and that is the porosity measurement with built on small diameter PVC casing.

  • PDF

A Calculation of Effective Dose Equivalent from Data of Environmental Monitoring around the Karlsruhe Nuclear Research Center (Karlsruhe 원자력연구소 주변의 환경방사능 측정자료로부터 실효선량당량계산)

  • Lee, Chang-Woo;Lee, Jeong-Ho;Wicke, A.
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.75-85
    • /
    • 1990
  • The dose calculations were carried out using environmental montoring data around Karlsruhe Nuclear Research Center(KfK). Ingestion of plant foods was the most important pathway, and the K-40 and Pb-210 natural radioisotopes in food were the most effective radiation source to man. The dose received from artificial nuclides were mostly emitted by gamma irradiation of Cs-134 and Cs-137 deposited on the ground. The effective dose equivalent in the KfK environment was far less than the dose equivalent limit recommended by ICRP.

  • PDF

An Enhancement Technique for Backlit Images using Laplace Pyramid Fusion (라플라스 피라미드 융합을 이용한 역광영상의 개선 방법)

  • Kim, Jin Heon
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.292-298
    • /
    • 2022
  • There is a limit to improving the image quality through global processing of images taken under backlighting because too bright and dark parts are mixed in one scene. This paper introduces a method to improve the quality of a photo by making two virtual images that improve the dark and bright areas of a backlit photo, and fusing them with the original image into a Laplacian pyramid. The proposed method reduces the computational burden by using histogram stretching and gamma transformation that can be simplified with LUT when creating the two virtual images. In addition, in order to obtain a color-enhanced image, contrast conversion was performed only on the luminance using the HSV coordinate system. The proposed technique showed its effectiveness by calculating several NIQA indicators using standard image data sets.

Study on Glomerular Filtration Rate comparison according to renal depth measurement of kidney donors (신 공여자에서 신장 깊이 측정에 따른 사구체여과율의 비교에 관한 고찰)

  • Lee, Han Wool;Park, Min Soo;Kang, Chun Goo;Cho, Seok Won;Kim, Joo Yeon;Kwon, O Jun;Lim, Han Sang;Kim, Jae Sam;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.48-56
    • /
    • 2014
  • Purpose $^{99m}Tc$-DTPA renal scintigraphy serves as a key indicator to measure a kidney donor's Glomerular Filtration Rate (GFR) and determine the possibility of kidney transplant. The Gates method utilized to measure GFR considers 3 variables of renal depth, injection dose, and net kidney counts. In this research, we seek to compare changes in kidney donors' GFR according to renal depth measurement methods of the 3 variables. Materials and Methods We investigated 32 kidney donors who had visited the hospital from October, 2013 to March, 2014 and received abdominal CT and $^{99m}Tc$-DTPA GFR examination. With the cross-section image of the CT and the lateral image from a gamma camera, we measured the renal depth and compared with renal depth calculation equations-Tonnesen, Taylor, and Itoh methods. Renal depth-specific GFR was calculated by using Xeleris Ver. 2.1220 of GE. Then the results were compared with MDRD (Modification of Diet Renal Disease) GFRs based on serum creatinine level. Results The renal depths measured based on the CT and gamma camera images showed high correlation. Tonessen equation gave the lowest GFR value while the value calculated by using the renal depth of CT image was the highest with a 16.62% gap. MDRD GFR showed no statistically significant difference among values calculated through Taylor, Itoh, CT and gamma camera renal depth application (P>0.05), but exhibited a statistically significant change in the value based on Tonnesen equation (P<0.05). Conclusion This research has found that, in GFR evaluation in kidney donors by utilizing $^{99m}Tc$-DTPA, Tonnesen equation-based Gates method underestimated the value than the MDRD GFR. Therefore, if a MDRD GFR value shows a huge difference from the actual examination value, using an image-based renal depth measurement, instead of Tonnesen equation applied to Gates method, is expected to give an accurate GFR value to kidney donors.

  • PDF

Study of Scatter Influence of kV-Conebeam CT Based Calculation for Pelvic Radiotherapy (골반 방사선 치료에서 산란이 kV-Conebeam CT 영상 기반의 선량계산에 미치는 영향에 대한 연구)

  • Yoon, KyoungJun;Kwak, Jungwon;Cho, Byungchul;Kim, YoungSeok;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • The accuracy and uniformity of CT numbers are the main causes of radiation dose calculation error. Especially, for the dose calculation based on kV-Cone Beam Computed Tomography (CBCT) image, the scatter affecting the CT number is known to be quite different by the object sizes, densities, exposure conditions, and so on. In this study, the scatter impact on the CBCT based dose calculation was evaluated to provide the optimal condition minimizing the error. The CBCT images was acquired under three scatter conditions ("Under-scatter", "Over-scatter", and "Full-scatter") by adjusting amount of scatter materials around a electron density phantom (CIRS062, Tissue Simulation Technology, Norfolk, VA, USA). The CT number uniformities of CBCT images for water-equivalent materials of the phantom were assessed, and the location dependency, either "inner" or "outer" parts of the phantom, was also evaluated. The electron density correction curves were derived from CBCT images of the electron density phantom in each scatter condition. The electron density correction curves were applied to calculate the CBCT based doses, which were compared with the dose based on Fan Beam Computed Tomography (FBCT). Also, 5 prostate IMRT cases were enrolled to assess the accuracy of dose based on CBCT images using gamma index analysis and relative dose differences. As the CT number histogram of phantom CBCT images for water equivalent materials was fitted with a gaussian function, the FHWM (146 HU) for "Full-scatter" condition was the smallest among the FHWM for the three conditions (685 HU for "under scatter" and 264 HU for "over scatter"). Also, the variance of CT numbers was the smallest for the same ingredients located in the center and periphery of the phantom in the "Full-scatter" condition. The dose distributions calculated with FBCT and CBCT images compared in a gamma index evaluation of 1%/3 mm criteria and in the dose difference. With the electron density correction acquired in the same scatter condition, the CBCT based dose calculations tended to be the most accurate. In 5 prostate cases in which the mean equivalent diameter was 27.2 cm, the averaged gamma pass rate was 98% and the dose difference confirmed to be less than 2% (average 0.2%, ranged from -1.3% to 1.6%) with the electron density correction of the "Full-scatter" condition. The accuracy of CBCT based dose calculation could be confirmed that closely related to the CT number uniformity and to the similarity of the scatter conditions for the electron density correction curve and CBCT image. In pelvic cases, the most accurate dose calculation was achievable in the application of the electron density curves of the "Full-scatter" condition.

Clinical significance of serum vascular endothelial growth factor in Kawasaki disease (가와사끼병에서 혈청 Vascular Endothelial Growth Factor의 임상적 의의)

  • Lee, Ho Seok;Yun, Sin Weon;Jung, Young Soo;Chae, Soo Ahn;Lim, In Seok;Lee, Dong Keun;Choi, Eung Sang;Yoo, Byung Hoon;Lee, Mi Kyung
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.995-1004
    • /
    • 2007
  • Purpose : Kawasaki disease is a systemic vasculitis, leading cause of pediatric acquired heart disease. Vascular endothelial growth factor (VEGF) has functions as vascular permeability factor, plays an important role in coronary artery lesion (CAL). We studied the clinical significance of serum VEGF in Kawasaki disease. Methods : Kawasaki group was 49 patients, and control group was 15 patients. Diagnosis followed AHA (American Heart Association) diagnostic criteria, with blood sampling in acute, subacute, and convalescent phase. Echocardiographic abnormalities were defined and the definition of intravenous gamma globulin (IVGG)-responsive and IVGG-resistant was determined. Results : Serum VEGF of Kawasaki group was significantly higher than of control group. Comparison of serum VEGF between CAL and non-CAL group, between carditis group and non-carditis group showed no significant differences. Subacute serum VEGF was statistically higher in IVGG-resistant group than in IVGG-responsive group, and serum VEGF of IVGG-resistant group in subacute phase was statistically higher than in the other phases. Serum VEGF of convalescent CAL and non-CAL group in acute and subacute phase had meaningful differences. Total fever duration and subacute serum VEGF had positive correlation. Acute serum VEGF had positive correlation with ESR and CRP, all phases serum VEGF had also positive correlation with WBC. Acute and subacute serum VEGF had negative correlations with hemoglobin and albumin. Conclusion : Serum VEGF can help to determine the severity of Kawasaki disease, especially subacute serum VEGF seems to be used as a prognostic factor of coronary complication. Afterward, further studies needed with more strict diagnostic criteria and more study groups.