• Title/Summary/Keyword: 감마지수법

Search Result 16, Processing Time 0.033 seconds

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF

Effects of γ-Irradiation from Cobalt-60 on Immunogenicity of Eimeria tenella (Cobalt-60 γ-선 조사가 Eimeria tenella 의 면역원성에 미치는 영향)

  • Youn, Hee-jeong;Kang, Yung-bai;Jang, Du-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.657-664
    • /
    • 1993
  • To reveal the immunogenicity of ${\gamma}-irradiated$ E tenella and its progeny, a series of experiments on the effects of Cobalt-to ${\gamma}-irradiation$ was performed. The SPF chickens inoculated with diffenrt doses of inoculum were challenged with $1{\times}10^5$ oocysts of virulent E tenella. The levels of 100 Gy ${\gamma}-irradiation$ from $^{60}Co$ and of inoculum with $1{\times}10^4$ oocysts were recognized as proper as immunogen by comparison of survival rates, body weight gains, blood in feces and lesion scores in the chickens. In these trials of challenge with virulent E tenella after inoculation with $1{\times}10^4$ oocysts of the ${\gamma}-irradiated$ E tenella and its progeny, the survival rates of the chickens challenged with the virulent E tenella after immunization with the 1st and the 3rd progeny groups of ${\gamma}-irradiated$ E tenella oocysts were higher(l00%) than that(87.0%) of the challenged control group. The signs of blood in feces and the lesion scores were seen markedly lower with the ourput of the smaller number of oocysts, i.e. OPG 103,900 and 25,800 in the groups of the 1st and the 3rd progeny, respectively, than those(OPG 1,658,900) of the challenged control group. The body weight gains of the 1st and the 3rd progeny groups, the 1st week and the 2nd week after challenge, were higher (2.6g and 155.4g, 11.6g and 168.9g respectively) than those(-85.8g and 63.6g, respectively) of the challenged control group, and the feed conversion ratios(FCR 3.28 and 2.96) of the 1st and the 3rd progeny groups were lower than that(FCR 5.60) of the groups challenged control group. The anticoccidial indices(70.5 and 93.9) of the groups challenged with the virulent oocysts of E tenella after immunization with the 1st and the 3rd progeny of the ${\gamma}-irradiated$ E tenella were significantly higher than that (ACI -81.9) of the challenged control group. It was thought that the immunogenicity of ${\gamma}-irradiated$ E tenella would be increase according to increase the number of generation passaged in chicken. That might be because of increasing the pathogenicity of ${\gamma}-irradiated$ E tenella according to increase the number of generation passaged in chicken.

  • PDF

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.

Usefulness of Three-phasic Bone Scan in Young Male Patients Suspected of Post-traumatic Reflex Sympathetic Dystrophy Syndrome (외상후 교감신경 이영양증이 의심되는 젊은 남자 환자들에서 삼상 골스캔의 유용성)

  • Lee, Won-Woo;Kim, Tae-Uk;Kim, Tae-Hoon;Jung, Cheoul-Yun;Moon, Jin-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.52-60
    • /
    • 2001
  • Purpose: In young male patients who suffered several kinds of trauma with subsequent suspicious reflex sympathetic dystrophy syndrome, we performed three-phasic bone scan in order to investigate its usefulness. Materials and Methods: Patients with narrow range of age (21-25. mean $22.8{\pm}1.3$, all male) were included with suspicious reflex sympathetic dystrophy syndrome of 12 feet and 5 hands. Only one was bilateral feet case and 16 were ipsilateral (Rt:13, Lt:3). The etiologic traumas were 4 fractures, 4 sprains, 3 blunt trauma, 2 cellulitis, 1 tendon tear, 1 crush injury, 1 overexercise, and 1 unknown. Radiologically 3 showed osteoporotic changes. Three-phasic bone scans were performed $21.2{\pm}7.3wks$ after trauma. Results: According to symptom complex, confirmatory reflex sympathetic dystrophy syndrome 4 cases and suspicious 13 were analyzed. All confirmatory cases (100%) showed increased uptake at delay phase with periarticular accentuation. Of confirmatory 4 cases, 2 showed increased uptake in all three phases (perfusion: P, blood pool: B, and delay: D), and other 2 revealed decreased P but, both increased B and D. Of suspicious 13 cases, 9(69.2%) had increased D (4 periarticular and 5 focal), 2 decreased D, and 2 symmetric D. In 12 foot cases, so-called weight hearing patterns - increased contralateral sole at P and B - were revealed in 7(58.3%). Conclusion: Diffuse periarticular increased uptake at delay phase of three-phasic bone scan was a compatible finding to reflex sympathetic dystrophy syndrome in young male patients whose symptom complex strongly designated post traumatic reflex sympathetic dystrophy syndrome.

  • PDF

Spectral Analysis of Hidden EEG Arousal Activity in Periodic Leg Movements in Sleep without Microarousal (미세각성이 없는 수면중 주기성 사지운동증 뇌파의 스펙트럼 분석)

  • Cyn, Jae-Gong;Seo, Wan-Seok;Oh, Jung-Su;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.10 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Objectives: Periodic leg movements in sleep (PLMS) might be subdivided based upon whether or not they are associated with visible EEG microarousals (MA). MA is considered to be responsible for nonrestorative sleep and daytime fatigue. The American Sleep Disorders Association's (ASDA) scoring rules for MA based on visual analysis of the EEG changes suggest that MA should last more than 3 seconds. However, it has been suggested that visual analysis may not detect some changes in EEG activity. This study is aimed at measuring changes in EEG spectra during PLMS without MA in order to better understand the arousing response of PLMS. Methods: Ten drug-free patients (three men and seven women) diagnosed with PLMS by polysomnography were studied. Spectral analysis of the EEG was performed in each patient on 30 episodes of PLMS without MA, chosen randomly across the night in stage 2 non-REM sleep. We applied stricter criteria for MA compared to ASDA, by defining it as a return to alpha and theta frequency lasting at least 1 second. Results: The mean PLMS index was $16.7{\pm}10.0$. The mean PLMS duration was $1.3{\pm}0.7$ seconds. Comparison of 4-second EEG activity both before and after the onset of PLMS without MA using independent t-test showed that the movements were associated with significant increase of relative activity in the delta band (p=0.000) and significant decrease of activity in the alpha (p=0.01) and sigma (p=0.000) bands. No significant decrease in the theta (p=0.05), beta (p=0.129), or gamma (p=0.062) bands was found. Conclusion: PLMS without MA was found to be associated with EEG change characterized by increase in the delta frequency band. This finding seems to be compatible with the hypothesis of an integrative hierarchy of arousal responses of Sforza's. Considering that the subjects had lower PLMS index and shorter PLMS duration than those of the previous study, it is suggested that an even less severe form of PLMS without MA could induce neurophysiologic change, which may potentially be of clinical significance.

  • PDF

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.