• Title/Summary/Keyword: 감도 측정

Search Result 2,749, Processing Time 0.033 seconds

Calibration of Quadrupole Mass Spectrometer for Various Gases (Quadrupole Mass Spectrometer의 기체별 감도 특성)

  • 신용현;홍승수;이철로;임재영;박재홍;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.1
    • /
    • pp.9-16
    • /
    • 1993
  • 부분압 분석 장비의 감도 측정 시스템을 설계 제작하였다. 이 시스템을 이용하여 부분압측정기기로 많이 쓰이는 Quadrupole Mass Spectrometer의 N2, O2, Ar, CO, H2에 대한 감도를 10-4∼10-8torr 영역에서 측정하여 감도의 압력 의존성을 보고 검출 방식, Emission current, Secondary Electron Multiplier 전압 등이 감도에 미치는 영향도 측정하였다. 실험 결과 기체 종류에 따라서는 물론 사용조건에 따라서도 감도의 절대값 변화 및 압력 의존성 변화가 아주 심한 것을 알 수 있었다. 따라서 Quadrupole Mass Spectrometer를 정량적인 측정에 이용하기 위해서는 이에 대한 감도 측정 및 특정조사가 반드시 선행되어야 한다.

  • PDF

Characteristics of Conducting Polymer-based Urea Sensors with Planar Pt Electrode on Silicon Substrate (전도성 고분자를 이용한 요소 측정용 반도체 바이오센서의 특성)

  • Park, Sung-Ho;Jin, Joon-Hyung;Min, Nam-Ki;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1454-1456
    • /
    • 2001
  • 신장병 진단에 중요한 요소의 농도를 측정하기 위한 요소 센서를 반도체 위에 개발이 연구의 목적이다. 센서의 감도 측정은 선형 전위 주사법(Linear sweep voltammtry)을 이용하였다. 선형 전위 주사법은 가역적이든 비가역적이든 관계없이 cottrell 식에 의한 전류와 농도의 직선관계로부터 감도를 측정할 수 있는 장점이 있고 또한 저 농도에서 민감하게 반응한다. 따라서 기존 전위차 측정형 바이오 센서(Potentiometric biosensor)에서 규명할 수 없는 감도 문제를 선형 전위 주사법으로 규명하고자 하였다. 센서전극은 p-type 실리콘 웨이퍼 위에 전극을 제작했다. 그 위에 cyclic voltammetry 법을 사용하여 전도성 고분자를 전기 중합 하였고, 그위에 다시 chronoamperometry법을 사용하여 우레아제를 고정화 하여 작업전극으로 제작하였다. 센서의 감도는 phosphate buffer 용액(pH7.4)속에서 온도 35$^{\circ}C$를 유지하며 측정하였다.

  • PDF

Measurement of the Perceptual Distortion of 3D Depth/Shape in Realistic Broadcasting (실감 방송에서의 3D 깊이/모양 지각감 왜곡의 측정)

  • Li, Hyung-Chul O.
    • Journal of Broadcast Engineering
    • /
    • v.14 no.2
    • /
    • pp.210-218
    • /
    • 2009
  • The 3D shape as well as the depth of an object presented on a 3D display is perceptually distorted depending on viewing distance. It is quite undesirable that different observers perceive different depth and shape from an object displayed on a 3D monitor. To resolve the problem of perceptual distortion of 3D depth and shape, the degree of the distortion should be measured appropriately. As a basis for resolving these problems, the present research suggests an instrument for measuring the degree of the perceptual distortion of 3D depth and shape.

Characteristics of Quadrupole Mass Spectrometer for Partial Pressure Measurement in CO-$H_2$ Gas Mixture (CO와 $H_2$ 혼합기체에 대한 Quadrupole Mass Spectrometer의 감도 특성)

  • 신용현;홍승수;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.3
    • /
    • pp.314-318
    • /
    • 1993
  • Quadrupole mass spectrometer는 부분압 측정 및 잔류기체 분석에 널리 이용되고 있는 장비이다. CO, H2, Ar이 혼합되어 존재할 때 quadrupole mass spectrometer의 감도를 10-4∼10-8torr영역에서 측정하고 단일기체로 존재할 때의 감도와 비교하였다. 그 결과 일정한 부분압을 유지하고 있는 경우라도, 주위 분위기 기체 종류와 부위기 기체 압력에 따라 감도 별화가 심한 것을 알 수 있었다. 따라서 QMS를 부분압 측정이나 조성분석에 이용하기 위해서는 이에 대한 특성조사가 반드시 필요하다.

  • PDF

DEVELOPMENT OF UHF SENSOR FOR PARTIAL DISCHARGE DIAGNOSIS OF POWER TRANSFORMER (전력변압기 부분방전 진단을 위한 UHF 센서 개발)

  • Ryu, Eun-Tae;Hwang, Kyung-Rok;Jung, Jae-Ryong;Yang, Hang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1556-1557
    • /
    • 2011
  • 변압기의 고체 절연이 열화 되거나 불순물 및 수분이 혼입되어 임계치 이상의 고전계가 인가되면 결합부분에서 부분방전이 발생한다. 현재 변압기에서 부분방전을 검출하기 위해서는 부싱탭을 이용하거나 전류센서, 초음파센서 등을 이용하여 부분방전을 검출하고 있지만 전기적인 부싱탭이나 전류센서를 이용한 검출 방법은 주변 잡음의 영향을 많이 받고 초음파법은 감도가 낮다는 단점을 가지고 있다. 이에, UHF 방식을 이용한 부분방전 검출 기술이 전력기기의 초기 고장진단을 발견하는 효과적인 방법으로 인식되고 있다. 최근에는 이러한 UHF 진단방식의 높은 감도, 외부노이즈에 대한 적은 영향, 온라인 측정의 가능성의 장점으로 전력용 변압기에도 적용되고 있다. 본 논문에서는 전력 변압기에서 PD 진단에 적합한 UHF 센서의 개발에 대해서 소개한다. 제안된 UHF 센서는 광대역(500 ~ 1,500MHz)에서 측정이 가능하며 감도가 우수하며 특정 대역에서 공진점을 가지는 다중 공진 모노폴 안테나 타입이다. 안테나 시뮬레이션 및 해석을 통해 유중 부분방전을 모의하여 감도 측정을 실시한 결과 제안된 UHF 센서가 전력용 변압기의 부분방전 측정에서 높은 감도를 나타냈으며, 기존 측정 방식의 단점을 보완할 수 있는 방안으로서 전자파를 이용한 부분방전 측정에 대한 기초연구를 실시하여 변압기 운전중에 전자파 측정에 의한 부분방전 감시가 가능한 것으로 나타났다.

  • PDF

A Psychometric Analysis and Revision of the Mathematics Teaching Efficacy Beliefs Instrument Using the Rasch Model: Focusing on Personal Teaching Efficacy (Rasch 모형을 활용한 수학 교수 효능감 측정 도구의 심리측정적 특성 분석 및 수정: 개인 효능감 요인을 중심으로)

  • Hwang, Sunghwan
    • Journal of the Korean School Mathematics Society
    • /
    • v.24 no.1
    • /
    • pp.1-18
    • /
    • 2021
  • The purpose of the study was to examine the psychometric properties of the personal teaching efficacy of the Mathematics Teaching Efficacy Beliefs Instrument and revise the scale for the use of Korean elementary school teachers. Data were collected from 299 elementary teachers. A Rasch analysis was used to evaluate unidimensionality and appropriateness of category use and item difficulty levels. Moreover, person separation and reliability as well as item separation and reliability were examined using the revised scale. Results suggested that the original personal teaching efficacy scale (13 items with five categories) had several problems in its psychometric properties. Thus, we revised the scale into eight items with four categories. The follow-up analysis results showed the revised scale provided sufficient psychometric properties for measuring Korean elementary school teachers' self-efficacy beliefs for teaching mathematics. Limitations and implications of the study were also discussed.

Development and Validation of Mathematics Teaching Efficacy Scale for South Korean Elementary Teachers (초등학교 교사의 수학 교수 효능감 측정 도구 개발 연구)

  • Kim, Rina;Sihn, Hang Gyun
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.21 no.3
    • /
    • pp.443-460
    • /
    • 2017
  • The aim of this study was to develop and validate a mathematics teaching efficacy scale for South Korean Elementary Teachers. The sample was consisted of 300 elementary teachers in South Korea. A total of 13 items were developed and examined for internal consistence. The results of this study showed that the proposed scale was appropriate to represent mathematics teaching efficacy of elementary teachers.

  • PDF

The Development of Mathematics Teaching Efficacy Instrument (수학 교수 효능감 측정 도구 개발 연구)

  • Kang, Moonbong;Kim, Jeongha
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.18 no.3
    • /
    • pp.519-537
    • /
    • 2014
  • Teacher efficacy influences teacher's own behaviors in class and students outcomes such as achievement, motivation and their own self-efficacy. In recent years, self efficacy and teacher efficacy are becoming more popular in many educational aspects. Teacher efficacy depends on him/her and each tasks and goals. Therefore, we need special instrument for measuring mathematics teacher efficacy. On this study, we derived educationally meaningful factors on mathematics teacher efficacy from previous literature. We developed Mathematics Teaching Efficacy Instrument(MTEI) consisted of 30 items with 6-point Likert scale. The six factors are as follows; mathematics teaching efficacy expectancy, mathematics teaching outcome expectancy, mathematics teaching content knowledge, teacher belief on their own students, the past mathematics learning experience for teacher own, influence from social-cultural environment.

  • PDF

Characteristics of Voltammetric Urea Sensors Based on Poly(3-methylthiophene) film (Poly(3-methylthiophene)막 위에 urease를 고정화 한 voltammetric biosensor의 특성)

  • Park, Sung-Ho;Park, Buh-Hun;Min, Nam-Ki;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1766-1768
    • /
    • 2000
  • 신장병 진단의 척도로 요소의 농도는 매우 중요하다. 요소의 농도를 측정하기 위한 센서개발이 본 연구의 목적이다. 기존의 Potentiometry법은 Nernst식이 적용된다는 가정하에 감도를 측정했다. 실험결과 전극상에서 우레아제의 요소 가수분해 반응은 Nernst식을 적용할 수 없는 비가역적인 반응으로 판단되어 센서의 감도 측정을 Linear sweep Voltammetry(LSV)법을 이용하였다. Voltammetry법은 가역적이든 비가역적이든 관계없이 Cottrell 식에 의한 전류와 농도의 직선관계로부터 감도를 측정할 수 있다는 장점이 있다. 센서 전극의 표면은 SEM으로 분석하였고, LSV 법으로 측정한 센서의 감도는 $34{\mu}A$/decade 였다.

  • PDF

The Effect of Training Using Artificial Intelligence Virtual Reality Program on Balance and Fall Efficacy For Stroke patients (인공지능 가상현실 게임 프로그램 적용이 뇌졸중 환자의 균형과 낙상효능감에 미치는 영향)

  • Lee, min-jae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2016.05a
    • /
    • pp.285-286
    • /
    • 2016
  • 본 연구는 가상현실시스템을 이용한 훈련이 뇌졸중 환자의 균형과 낙상효능감에 미치는 영향을 알아보기 위해 실시하였다. 연구 대상자는 뇌졸중 환자 20명으로 실험군 10명 대조군 10명씩 각각 배정하였다. 실험군과 대조군 모두 일반적인 주 5회의 물리치료와 작업치료를 받았다. 실험군은 추가적으로 가상현실 프로그램을 이용하여 8주간 1일 20분 주 3회 시행하였다. 본 연구의 측정은 균형수행 능력검사, 낙상효능감 척도검사를 사용하였다. 두 군 간 훈련 후 측정 사이에 균형수행 능력검사와, 낙상효능감 검사에서 통계적으로 유의한 차이를 보였다(p<0.05). 또한 각 군 간 훈련 후 측정 사이에 균형수행 능력검사와, 낙상효능감 검사에서 통계적으로 유의한 차이를 보였다(p<0.05). 따라서 가상현실 프로그램 병행한 훈련이 뇌졸중 환자의 균형과 낙상효능감을 향상시키는데 긍적적인 도움을 주어 유용한 뇌졸중 환자의 치료 프로그램으로 사용될 수 있을 것으로 보여 진다.

  • PDF