• Title/Summary/Keyword: 감도분포

Search Result 91, Processing Time 0.044 seconds

Measurements and Statistical Modeling of Man-made Noise (인위적인 전자파 잡음의 측정 및 통계적 모형)

  • 김종호;우종우;백락준;윤현보
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.2
    • /
    • pp.159-170
    • /
    • 1998
  • Man-made noise in PCS frequency range are measured using the three axis antennal with common port and the measured data are statistically treated for modeling. The can optimal parameters of the measured APD curves can be calculated fast by using the Composite Approximation Algorithm. The calculated APD parameters can reduce the EM-environments Data Base memory and also be applied to determine the output and sensitivity margin of the transmitter and the receiver.

  • PDF

Thermal Transfer Analysis of Micro Flow Sensor Based on Excel (Excel을 이용한 마이크로 흐름센서의 열전달 해석)

  • Kim Tae-Yong;Chung Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.251-254
    • /
    • 2006
  • 마이크로 흐름센서는 종래의 반도체 집적회로 공정기술을 이용하여 소형으로 제작이 가능하며, 빠른 응답특성을 가지는 장점이 있어 다양한 응용이 기대되고 있다. 본 연구에서는 넓은 흐름의 세기영역에서 정밀한 감도를 가지는 2차원 마이크로 흐름센서를 실리콘 기판위에 설계하여 왔다. 이러한 흐름센서의 정확한 온도특성을 분석하고 이 결과로부터 최적을 온도 감지막 위치를 결정할 필요가 있다. 설계방법으로서 표계산 소프트웨어 Excel을 이용하여 열운송방정식의 차분 방정식을 매크로 기능을 이용하여 적용하고 워크시트 내에서 셀 참조방식을 활용하여 자동 계산을 수행하도록 구현하였다. 본 연구에서는 Excel을 활용한 효율적인 설계방법을 제시하고 하나의 히터와 양측에 한 쌍의 온도 감지막을 가진 마이크로 흐름센서에 대해서 열전달 특성을 계산하고 이로부터 최적을 온도 감지막 위치를 결정할 수 있었다.

  • PDF

Novel PD Sensor Design for Stator Winding Diagnosis of Turbine Generators (터빈발전기의 고정자권선 진단을 위한 새로운 부분방전 센서설계)

  • Yi, Sang-Hwa;Hwang, Don-Ha;Kang, Dong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2042-2043
    • /
    • 2007
  • 고압회전기의 운전중 부분방전을 효과적으로 측정하고 진단하기위해 고정자 권선과 슬롯사이에 취부 되는 방향성 결합기형태의 부분방전센서가 일부 사용되고 있다. 기존 결합기형 센서는 마이크로스트립 등의 전송선로 타입으로, 센서 출력 단자의 효과적인 매칭을 목표로 설계되었으나, 센싱도체의 폭이 좁아 권선으로부터 효과적인 커플링이 힘들다. 본 논문에서는 고정자 권선 및 슬롯 구조의 전계분포 계산결과를 바탕으로 부분방전 신호 측정에 효과적인 형태의 센서를 설계하였다. 제작된 센서를 실제와 동일한 고정자 권선 및 슬롯 구조에서 타 센서와 비교하여 성능을 시험한 결과, 기존 마이크로스트립타입의 센서와 상용센서에 비해 좋은 감도를 가지는 것으로 나타났다.

  • PDF

반도체 및 디스플레이 공정에서 발생하는 오염입자 측정을 위한 PBMS (Particle Beam Mass Spectrometer)개발

  • Yun, Seok-Rae;Lee, Gyu-Chan;Kim, Tae-Seong;Kim, Dong-Bin;Gang, Sang-U;Park, Myeong-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.84-84
    • /
    • 2013
  • 본 개발은 반도체 또는 디스플레이 공정상의 불량률을 최소화 하기 위하여 시작 되었다. PBMS를 이용하여 공정상에 발생하는 오염입자들을 모니터링하고자 하였으나 기존의 시스템은 크기, 감도, 교정등의 문제들로 현장적용에 무리가 있었던 것이 사실이다. 주식회사 이엘은 PBMS의 문제들을 개선 또는 제거하여 현장에 적용 가능하도록 하였으며 전용 프로그램을 개발하여 사용자의 편의성을 증대하였다.

  • PDF

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Measurements and Statistical Modeling of Ignition Noise from Vehicle (자동차 점화계통에서 발생된 전자파 잡음의 측정 및 통계적 모형)

  • 김종호;윤현보;백락준;우종우
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.4
    • /
    • pp.390-402
    • /
    • 1997
  • The ignition noises from the vehicle are measured and the measurement data are statistically treated for modeling. The low-noise amplifier and band-pass filter are added between the receiver and the three axes antenna for low noise level measurement and the APD and PSD are measured in 800 MHz frequency range. The measured APD curves can be expressed in terms of sensitivity study of each model through 3(class A) or 6(Class B) parameters variation, and these optimal parameter can easily be calculated by using the Composite Approximation Algorithm. The selected APD parameter can be used for making the Data Base EM-environments and also applied to determine the output and sensitivity margin for the transmitter and receiver. 'Digital microwave transmission systems are equipped with equalizer against fading during multipath fading. In this paper, we proposed variable reference tap position equalizer that varies the reference tap according to fading type to archive better performance. We got the perf?mance improvement about 4~5 dB in MP condition and 2~3 dB in NMP condition from simulation results.

  • PDF

Feasibility Study of the Real-Time IMRT Dosimetry Using a Scintillation Screen (고감도 형광판을 이용한 실시간 선량측정 가능성 연구)

  • Lim Sang Wook;Yi Byong Yong;Ko Young Eun;Ji Young Hoon;Kim Jong Hoon;Ahn Seung Do;Lee Sang Wook;Shin Seong Soo;Kwon Soo-Il;Choi Eun Kyoung
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.64-68
    • /
    • 2004
  • Purpose : To study the feasibility of verifying real-time 2-D dose distribution measurement system with the scintillation screen for the quality assurance. Materials and Methods : The water phantom consisted of a scintillation screen (LANEX fast screen, Kodak, USA) that was axially located in the middle of an acrylic cylinder with a diameter of 25 cm. The charge-coupled device (CCD) camera was attached to the phantom In order to capture the visible light from the scintillation screen. To observe the dose distribution In real time, the intensity of the light from the scintillator was converted to a dosage. The isodose contours of the calculations from RTP and those of the measurements using the scintillation screen were compared for the arc therapy and the Intensity modulated radiation therapy (IMRT). Results : The kernel, expressed as a multiplication of two error functions, was obtained in order to correct the sensitivity of the CCD of the camera and the scintillation screen. When comparing the calculated isodose and measured isodose, a discrepancy of less than 8 mm in the high dose region was observed. Conclusion : Using the 2-D dosimetry system, the relationship between the light and the dosage could be found, and real-time verification of the dose distribution was feasible.

Design of Miniaturized Magnetic Field Probe for Measurement of IC Surface Current Distribution (IC 표면 전류 분포 측정을 위한 초소형 자기장 프로브 설계)

  • Lee, Seung-Bae;Jeon, Young-Hyun;Kim, Byung-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.5
    • /
    • pp.154-161
    • /
    • 2009
  • Recently, as many functional blocks are integrated on a small area the high speed integrated circuits emerge as a critical electromagnetic interferer which causes mal-function of adjacent circuitries and lowers the sensitivity of the wireless receivers. Therefore, it is necessary to devise an precise analyzing tool to pinpoint the major electromagnetic noise contributor among the internal circuit blocks of high speed IC's. This paper presents the design, fabrication, and measurement results of the high resolution magnetic field probe which can measure the current density on the IC surface. In order to achieve the high resolution, the magnetic field probe is fabricated using 3-metal semiconductor process so that its thickness is reduced by 10% than that of conventional works. Through the magnetostatic analysis and EM simulation, spatial resolution and sensitivity to the nonmagnetic field components are analyzed. Experimentally, it is found that the fabricated probe can measure the current density on the IC surface with $210{\mu}m$-spatial-resolution.

CsX+ SNMS의 Matrix Effect 감소연구

  • 문환구;김동원;한철현;김영남;심태언
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1992.02a
    • /
    • pp.17-18
    • /
    • 1992
  • SIMS is an indispensable surface analysis instrument in trace element depth p profiling because of high detection sensitivity and excellent depth r resolution, however, it requires standard sample to do quantitative analysis d due to matrix effect depending on the species of impurities and sample m matricies and on the sputtering rates. A Among the SNMS technology developed to supply the deficiency, we researched i into CsX+ SNMS which improved the resul t quanti tati vely wi thout any extra epuipments. So basic SNMS functions were confirmed through matrix element composition rate a analysis using Si02 layer etc. and adaptability to trace element c concentration analysis was tried. For that purpose we compared SIMS depth profile data for Boron which presented s strong matrix effect on account of Fluorin existence after BF2 ion implantation on silicon substrate with SNMS data. d dynamic range were investigated. A After these experements we concluded that CsX+ SNMS reduced matrix effect and we could apply it to profile impurity elements.

  • PDF

Research of Matrix Effect Reduction of $CsX^+$ SNMS ($CsX^+$ SNMS의 Matrix Effect 감소연구)

  • 문환구;김동원;한철현;김영남;심태언
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.115-120
    • /
    • 1992
  • SIMS is an indispensable surface analysis instrument in trace element depth profiling because of high detection sensitivity and excellent depth resolution, however, it requires a standard sample to do quantitative analysis due to matrix effect depending on the species of impurities and sample matricies and on the sputtering rates. Among the SNMS technology developed to supply the deficiency, we researched into CsX+ SNMS which improved the result quantitatively without any extra epuipments. So basic SNMS functions were confirmed through matrix element composition rate analysis using Siq layer etc., and adaptability to trace element concentration alaysis was tried. For that purpose we compared SIMS depth profile data for Boron which presented strong matrix effect on account of Fluorin existence after BF2 ion implantation on silicon substrate with SNMS data. Also detection limit and dynamic range were investigated. After these experements we concluded that CsX+ SNMS reduced matrix effect and we could apply it to profile impurity elements.

  • PDF