• 제목/요약/키워드: 감도계수

Search Result 229, Processing Time 0.026 seconds

Analysis of detection of mass position and modified stiffness using the change of the structural dynamic characteristics (구조물의 동특성 변화로부터 변경된 질량 및 강성 해석)

  • Lee, Jung-Youn;Oh, Jae-Eung
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.786-791
    • /
    • 2004
  • This study proposed the analysis of mass position detection and modified stiffness due to the change of the mass and stiffness of structure by using the original and modified dynamic characteristics. The method is applied to examples of a cantilever and 3 degree of freedom by modifying the mass. The predicted detection of mass positions and magnitudes are in good agreement with these from the structural reanalysis using the modified mass.

  • PDF

Micro Thermopile for body Temperature (체온계용 마이크로 써모파일)

  • Yoo, Kum-Pyo;Kim, Yun-Ho;Byun, H.M.;kang, Moon-Sik;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2401-2403
    • /
    • 2005
  • MEMS를 기반으로 하는 써모파일은 여러 산업분야에 측정 센서로 각광받고 있다. 이러한 써모파일은 유속, 가스, 칼로리미터 및 비접촉식 체온계 등의 적외선 및 열 측정 소자로 사용되고 있다. 기존의 써모파일은 산화막/질화막/산화막이나 혹은 산화막/질화막의 공정을 사용하여 제작되며, 열전쌍은 지벡 계수가 큰 여러 가지 물질을 사용하여 제작되어 발표되고 있다. 그러나 본 논문에서는 저 스트레스 질화막을 사용하여 다이어프램을 제작하였다. 열전쌍은 인을 주입한 다결정 실리콘과 알루미늄을 직렬로 연결하여, 60쌍으로 제작하였고, 또한, 열접점의 열전쌍의 접합 모양을 변경하여 감도를 증가 시켰다. 소자의 기는 $3{\times}3mm$이고, 활성영역은 $1{\times}1mm$이다. 그리고 출력은 사람 체온인 $37^{\circ}C$일 때, 0.403mV의 출력전압을 보였다.

  • PDF

A Long-term Mortality Prediction Model for Patient with ST-segment Elevation Myocardial Infarction using Decision Tree (의사결정트리를 이용한 ST분절상승 급성심근경색증 환자를 위한 장기 사망 예측 모형)

  • Park, Soo-Ho;Park, Hyeon-Ah;Ryu, Kwang-Sun;Kim, Hyeong-Soo;Ryu, Keun-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06c
    • /
    • pp.139-141
    • /
    • 2012
  • 이 논문에서는 한국인 급성심근경색증 환자에 대한 KAMIR 데이터를 기반으로 ST분절상승 심근경색이 처음 발병한 환자의 사망에 영향을 미치는 위험요소들을 찾고, 이를 기반으로 ST분절상승 급성심근경색환자의 1년 이내 사망을 예측하는 모델을 제시한다. 총 22개의 속성 중에서 속성 선택 알고리즘을 적용한 결과 나이, 심장박출계수, 크레아티닌, 고감도 C-반응성 단백질 등 4개의 속성이 선택되었고, 이 속성들을 이용하여 더욱 정확한 예측 모델을 구축할 수 있었다. 제시된 모델을 통해서 고위험군 환자의 위험성을 평가하고 예후를 추정할 수 있을 것으로 기대한다.

Characteristics of a Solder-Clad FBG Temperature Sensor (땜납이 용융 부착된 FBG 온도 센서의 특성)

  • Pyoung, Jae-Hyub;Lee, Sang-Bae;Shin, Jong-Dug
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.10
    • /
    • pp.45-50
    • /
    • 1999
  • We report a solder-clad fiber Bragg grating(FBG) temperature sensor in order to obtain better Bragg wavelength sensitivity to temperature than a bare FBG sensor. The solder-clad FBG sensor shows a wavelength sensitivity improvement by a factor of four compared to the case of a bare FBG sensor at temperatures below $110^{\circ}C$. However, it has a sensitivity of 0.01 $nm/^{\circ}C$ at temperatures over $110^{\circ}C$, which is identical to that of a bare FBG sensor. Bragg wavelength of the sensor shows a blue-shift below $110^{\circ}C$ because the sensor is fabricated above melting temperature of solder. The thermal stress at the FBG-solder interface has been relieved by annealing, which results in a stable operation.

  • PDF

Humidity Sensor Using Microstrip Patch Antenna (마이크로스트립 패치 안테나를 이용한 습도 센서)

  • Junho Yeo
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.1
    • /
    • pp.71-76
    • /
    • 2023
  • In this paper, a humidity sensor using a microstrip patch antenna(MPA) and polyvinyl alcohol(PVA) is studied. PVA is a polymer material whose permittivity changes with humidity, and a rectangular slot is added to the radiating edge of the MPA, which is sensitive to changes in electric field, in order to increase the sensitivity to changes in relative permittivity. After thinly coating the area around the radiating edge with the rectangular slot of the MPA fabricated on a 0.76 mm-thick RF-35 substrate with PVA, the changes in the resonant frequency and magnitude of the MPA's input reflection coefficient are measured when relative humidity is adjusted from 40% to 80% in 10% increments at a temperature of 25 degrees using a temperature and humidity chamber. Experiment results show that when the relative humidity increases from 40% to 80%, the resonance frequency of the antenna' input reflection coefficient decreases from 2.447 GHz to 2.418 GHz, whereas the magnitude increases from -7.112 dB to -3.428 dB.

Development of Phantom and Comparison Analysis for Performance Characteristics of MOSFET Dosimeter (MOSFET 선량계 특성분석을 위한 팬톰 개발 및 특성 비교)

  • Chung, Jin-Beom;Lee, Jeong-Woo;Kim, Yon-Lae;Lee, Doo-Hyun;Choi, Kyoung-Sik;Kim, Jae-Sung;Kim, In-Ah;Hong, Se-Mie;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.48-54
    • /
    • 2007
  • This study is to develope a phantom for MOSFET (Metal Oxide Semiconductors Field Effect Transistors) dosimetry and compare the dosimetric properties of standard MOSFET and microMOSFET with the phantom. In this study, the developed phantom have two shape: one is the shape of semi-sphere with 10cm diameters and the other one is the flat slab of $30{\times}30cm$with 1 cm thickness. The slab phantom was used for calibration and characterization measurements of reproducibility, linearity and dose rate dependency. The semi-sphere phantom was used for angular and directional dependence on the types of MOSFETs. The measurements were conducted under $10{\times}10cm^2$ fields at 100cm SSD with 6MV photon of Clinac (21EX, Varian, USA). For calibration and reproducibility, five standard MOSFETS and microMOSFETs were repeatedly Irradiated by 200cGy five times. The average calibration factor was a range of $1.09{\pm}0.01{\sim}1.12{\pm}0.02mV/cGy$ for standard MOSFETS and $2.81{\pm}0.03{\sim}2.85{\pm}0.04 mV/cGy$ for microMOSFETs. The response of reproducibility in the two types of MOSFETS was found to be maximum 2% variation. Dose linearity was evaluated In the range of 5 to 600 cGy and showed good linear response with $R^2$ value of 0.997 and 0.999. The dose rate dependence of standard MOSFET and microMOSFET was within 1% for 200 cGy from 100 to 500MU/min. For linearity, reproducibility and calibration factor, two types of MOSFETS showed similar results. On the other hand, the standard MOSFET and microMOSFET were found to be remarkable difference in angular and directional dependence. The measured angular dependence of standard MOSFET and microMOSFET was also found to be the variation of 13%, 10% and standard deviation of ${\pm}4.4%,\;{\pm}2.1%$. The directional dependence was found to be the variation of 5%, 2% and standard deviation of ${\pm}2.1%,\;{\pm}1.5%$. Therefore, dose verification of radiation therapy used multidirectional X-ray beam treatments allows for better the use of microMOSFET which has a reduced angular and directional dependence than that of standard MOSFET.

  • PDF

Preliminary Study on Performance Evaluation of a Stacking-structure Compton Camera by Using Compton Imaging Simulator (Compton Imaging Simulator를 이용한 다층 구조 컴프턴 카메라 성능평가 예비 연구)

  • Lee, Se-Hyung;Park, Sung-Ho;Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.51-61
    • /
    • 2009
  • A Compton camera, which is based on the geometrical interpretation of Compton scattering, is a very promising gamma-ray imaging device considering its several advantages over the conventional gamma-ray imaging devices: high imaging sensitivity, 3-D imaging capability from a fixed position, multi-tracing functionality, and almost no limitation in photon energy. In the present study, a Monte Carlo-based, user-friendly Compton imaging simulator was developed in the form of a graphical user interface (GUI) based on Geant4 and $MATLAB^{TM}$. The simulator was tested against the experimental result of the double-scattering Compton camera, which is under development at Hanyang University in Korea. The imaging resolution of the simulated Compton image well agreed with that of the measured image. The imaging sensitivity of the measured data was 2~3 times higher than that of the simulated data, which is due to the fact that the measured data contains the random coincidence events. The performance of a stacking-structure type Compton camera was evaluated by using the simulator. The result shows that the Compton camera shows its highest performance when it uses 4 layers of scatterer detectors.

  • PDF

Thermoelectric Properties and Crystallization of $(Bi1-xSbx)_2Te_3 $ Thin Films Prepared by Magenetron Sputtering Process (마그네트론 스퍼터링법으로 제조한 $(Bi1-xSbx)_2Te_3 $박막의 결정성과 열전특성)

  • 연대중;오태성
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.62-62
    • /
    • 2000
  • 비접촉식 온도센서는 물체에서 방출하는 적외선 등의 복사신호를 열에너지로 전환하고 이를 다시 전기신호로 2차 에너지 변환하여 온도를 감지하는 센서로 인체 검지를 응용한 다양한 상품 및 교통, 방재, 빌딩 시스템 등의 분야에 널리 응용되고 있다. 비접촉식 적외선 센서는 열에너지를 전기에너지로 변환하는 방법에 따라 양자형과 열형으로 구분되며, 이중 양자형은 광전도나 광기전력 효과 등을 이용하여 감도 및 응답성이 우수하다는 장점을 지니고 있지만, 소자부를 80K 이하 온도로 유지시키는 냉각을 필요로 하므로 대형 제작이 불가피하고 그 용도가 제한적이다. 열형은 냉각이 필요 없고 소형으로 제작가능한 장점을 지니고 있어 써모 파일이나 초전체를 이용한 번용 센서가 보급되고 있다. 그러나 써모파일의 경우 출력되는 전기 신호가 미약하여 감도 및 응답성을 향상하기 위해 구조가 복잡하고, 특히 모터초퍼나 저항을 전압으로 변환시키는 전력기 등이 필요로 하는 단점을 지니고 있다. 따라서 이러한 문제점을 보완하기 위해 열전재료 박막을 이용한 적외선 센서를 개발하려는 노력이 진행중에 있다. 열전박막을 이용한 적외선 센서는 열전재료의 Seebeck 현상을 이용하여 열에너지에서 전기에너지의 변환이 자가발전으로 이루어져 offset과 외부 바이어스를 필요로 하지 않는다. 또한 작은 온도 변화에도 그 감도와 응답성이 높고, 출력신호가 커서 증폭기 등이 불필요한 장점을 지니고 있다. 특히 초전형 센서가 상온에서도 기판에 대한 열 확산을 제어해야 하는 문제점을 갖는 반면, 열전박막형 적외선 센서는 고온에서도 안정된 출력 신호를 얻을 수 있어 그 활용 온도 범위가 크게 확대될 것으로 기대된다. 본 실험에서는 우수한 열전특성을 갖는 (Bi1-xSbx)2Te3 박막을 얻기 위해 열팽창계수가 작고 알칼리 원소가 0.3% 이하로 포함되어 있는 corning glass(# 7059)를 기판으로 사용하였다. 또한 최적의 열전특성을 나타내는 조성을 실험적으로 구하기 위해 (Bi0.2Sbx)2Te3 조성의 합금 타? 위에 Bi2Te3 및 Sb2Te3 chip을 올려놓고 그 면적을 변화시켜 다양한 조성의 열전박막을 증착하였다. 열전박막의 증착시 산화와 오염에 의한 열전특성 변화를 최소화하기 위해 초기진공도를 1$\times$10-6 Torr로 하였으며, Ar 가스를 흘려주어 2$\times$102 Torr 의 증착진공도를 유지하였다. 열전박막을 증착하기 전에 기판을 10분간 200W의 출력으로 RF 처리하였으며, 30$0^{\circ}C$에서 33 /sec의 속도로 (Bi1-xSbx)2Te3 박막을 증착하였다. 이와 같이 제조된 (Bi1-xSbx)2Te3 박막의 미세구조를 SEM으로 관찰하고 EDS로 조성을 분석하였으며, XRD를 이용하여 결정성을 관찰하였다. 또한 (Bi1-xSbx)2Te3 박막의 Seebeeck 계수 및 전기비저항을 측정하고 증착된 박막조성, 결정상, 미세구조와 열전특성간의 상관관계를 고찰하였다.

  • PDF

Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT' (고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가)

  • Kim, Jaeil;Lim, Jeongjin;Cho, Seongwook;Noh, Kyeongwoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.54-58
    • /
    • 2019
  • Purpose At now, there are many kind of dedicated heart SPECT machine in clinical nuclear medicine. Among those, the fixed focusing type SPECT can make a good quality, quantity image because a detectors of this SPECT arranged forward a special ROI and didn't rotate around of body. So, in this paper, we will evaluate a spatial uniformity about resolution and sensitivity at a same plane of a fixed focusing type SPECT. Materials and Methods We used D-SPECT as a fixed focusing type SPECT and Cario MD as a rotated parallel type SPECT to comparing each other. We injected $^{99m}Tc(14.8MBq/1cc)$ to 10 capillary tube (diameter=1mm), and we set those line sources a tfield of view of each SPECT. And then we acquired SPECT date, we applied are construction by recommended methods. By using two tomography images, we calculated a full width of half maximum as a resolution and total counts as a sensitivity, and we compared a CV (coefficientofvariation) values between two images as a spatial uniformity. Results In case of D-SPECT, a CV of resolution and sensitivity are 7.45%, 12.34%. In case of Cario MD, an CV of resolution and sensitivity are 12.49%, 21.84% Conclusion As a results, CV of resolution and sensitivity of a fixed focusing type SPECT is 67.75%, 77.00% higher than ones of a rotated parallel type SPECT. It means that a fixed focusing type SPECT is more uniformed, because this new SPECT can reduce a motion blur artifact by rotating detector around body, also all of detector that made by semiconductor arrange forward a special FOV like heart.

Performance of the Magnetic Compass Made in Korea ( 2 ) - An Examination of the Damping Characteristics - (한국산 자기 컴퍼스의 성능 ( 2 ) - 제진특성 시험 -)

  • 안영화
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.2
    • /
    • pp.173-179
    • /
    • 1990
  • This paper described to be measured the damping Characteristics in the artificial magnetic field in order to estimate the stabilited of the card and characteristic of movement of the directional system of the magnetic compasses made in Korea. The results obtained are summarized as follows. 1) It is compared by the elements of performance of the magnetic compasses made in Korea with the standards for magnetic compass of the IMO NAV/ANNEX II. The results are suitabled in the korean off shore, but it is unsuitabled in the high latitude sea than over the latitude 60 degree. 2) The characteristic of damping curve by the diameter of cards when the diameter of cards are 170mm and 175mm(clearance are 10.0m, 12.5mm), the fricative error is indicated the least than the other ones.

  • PDF