• Title/Summary/Keyword: 간 초음파 영상

Search Result 230, Processing Time 0.031 seconds

Feature Extraction by Line-clustering Segmentation Method (선군집분할방법에 의한 특징 추출)

  • Hwang Jae-Ho
    • The KIPS Transactions:PartB
    • /
    • v.13B no.4 s.107
    • /
    • pp.401-408
    • /
    • 2006
  • In this paper, we propose a new class of segmentation technique for feature extraction based on the statistical and regional classification at each vertical or horizontal line of digital image data. Data is processed and clustered at each line, different from the point or space process. They are designed to segment gray-scale sectional images using a horizontal and vertical line process due to their statistical and property differences, and to extract the feature. The techniques presented here show efficient results in case of the gray level overlap and not having threshold image. Such images are also not easy to be segmented by the global or local threshold methods. Line pixels inform us the sectionable data, and can be set according to cluster quality due to the differences of histogram and statistical data. The total segmentation on line clusters can be obtained by adaptive extension onto the horizontal axis. Each processed region has its own pixel value, resulting in feature extraction. The advantage and effectiveness of the line-cluster approach are both shown theoretically and demonstrated through the region-segmental carotid artery medical image processing.

Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy (전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가)

  • Park, Sung Yong;Lim, Seung Kyu;Si, Myoung Geun;Lee, Ji Hae;Kim, Jong Yeol;Cho, Eun Joo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.

  • PDF

A Study on the Radiographic Diagnosis of Caroli's Disease (카롤리병의 방사선학적 진단에 대한 고찰)

  • Yeo-jin Hong;Min-a Kim;Soo-bin Kim;Jin-joo Song;Kyoung-hoon Jang;Min-cheol Jeon;Man-Seok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.385-392
    • /
    • 2023
  • Caroli's disease is a fibrocystic liver disease. Autosomal recessive disorder is characterized by congenital multiple dilatation of the bile duct. Computerized tomography, magnetic resonance imaging, cholangiography and ultrasound are among the methods for diagnosing caroli disease. Computerized tomography is essential for detecting and distinguishing fibroplastic liver disease and is useful for determining intrahepatic bile duct dilatation. However, awareness of the possible side effects of using contrast mediums is necessary. A typical method of magnetic resonance cholangiography is used for magnetic resonance imaging. A non-invasive examination can reduce the pain of the patient, and the anatomical structure of the bile pancreatic duct and the presence or absence of lesions can be easily and quickly observed. Biliary contrast is an effective diagnostic method that can directly visualize various cystic dilatations throughout the enlarged bile duct. However, since this procedure is also an invasive procedure, it is recommended not for diagnosis but for treatment purposes. Ultrasonography can confirm similar findings to computerized tomography. The hepatic artery root is difficult to prove with conventional grayscale ultrasound. However, it is of clinical value in that it can not only describe dilated bile ducts with vascular roots in the tube but also easily identify color Doppler signals in the tube. With the development of video diagnostics, early diagnosis has become possible through computerized tomography, magnetic resonance imaging, cholangiography, and ultrasound. In order to further contribute to the development of video diagnostics so that long-term prognosis can be improved after treatment through early diagnosis, we examined what aspects of each test's caroli disease appear.

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: I. Spherical Wave Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : I. 구형파 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.391-401
    • /
    • 2004
  • 3D imaging systems using 2D phased arrays have a large number of active channels, compelling to use a very expensive and bulky beamforming hardware, and suffer from low volume rate because, in principle, at least one ultrasound transmit-receive event is necessary to construct each scanline. A high speed 3D imaging method using a cross array proposed previously to solve the above limitations can implement fast scanning and dynamic focusing in the lateral direction but suffer from low resolution except at the fixed transmit focusing along the elevational direction. To overcome these limitations, we propose a new real-time volumetric imaging method using a cross array based on the synthetic aperture technique. In the proposed method, ultrasound wave is transmitted successively using each elements of an 1D transmit array transducer, one at a time, which is placed along the elevational direction and for each firing, the returning pulse echoes are received using all elements of an 1D receive array transducer placed along the lateral direction. On receive, by employing the conventional dynamic focusing and synthetic aperture method along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. In addition, in the proposed method, a volume of interest consisting of any required number of slice images, can be constructed with the same number of transmit-receive steps as the total number of transmit array elements. Computer simulation results show that the proposed method can provide the same and greatly improved resolutions in the lateral and elevational directions, respectively, compared with the 3D imaging method using a cross array based on the conventional fixed focusing. In the accompanying paper, we will also propose a new real-time 3D imaging method using a cross array for improving transmit power and elevational spatial resolution, which uses linear wave fronts on transmit.

Automated Measurement System of Carotid Artery Intima-Media Thickness based on Dynamic Programming (다이나믹 프로그래밍 기반 경동맥 내막-중막 두께 자동측정 시스템)

  • Lee, Yu-Bu;Kim, Myoung-Hee
    • Journal of the Korea Society for Simulation
    • /
    • v.16 no.1
    • /
    • pp.21-29
    • /
    • 2007
  • In this paper, we present a method of detecting the boundary of the intima-media complex for automated measurement based on dynamic programming from carotid artery B-mode ultrasound images and then show the experimental results. We apply the dynamic programming for determining the optimal locations that a cost function is minimized. The cost function includes cost terms which are representing image features such as intensity, intensity gradient and geometrical continuity of the vessel interfaces. Moreover, we improve the boundary continuity by applying the B-spline to smooth the rough boundary due to noise such as speckle, dropout and weak edges. The proposed method has obtained more accurate reproducible results than conventional edge-detection by considering multiple image features and ensures efficient automated measurement by solving the problems of the inter- and intra-observer variability and its inefficiency due to manual measurement.

  • PDF

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.403-414
    • /
    • 2004
  • In the accompanying paper, we proposed a real. time volumetric imaging method using a cross array based on receive dynamic focusing and synthetic aperture focusing along lateral and elevational directions, respetively. But synthetic aperture methods using spherical waves are subject to beam spreading with increasing depth due to the wave diffraction phenomenon. Moreover, since the proposed method uses only one element for each transmission, it has a limited transmit power. To overcome these limitations, we propose a new real. time volumetric imaging method using cross arrays based on synthetic aperture technique with linear wave fronts. In the proposed method, linear wave fronts having different angles on the horizontal plane is transmitted successively from all transmit array elements. On receive, by employing the conventional dynamic focusing and synthetic aperture methods along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. Mathematical analysis and computer simulation results show that the proposed method can provide uniform elevational resolution over a large depth of field. Especially, since the new method can construct a volume image with a limited number of transmit receive events using a full transmit aperture, it is suitable for real-time 3D imaging with high transmit power and volume rate.

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

Comparison of Ultrasound Histogram in Liver, Kidney and Spleen in Beagle Dogs (비글견에 있어서 간, 신장 및 비장의 초음파 히스토그램 비교)

  • Lee Kichang;Jung Joohyun;Oh Sunkyoung;Jeong Yucheol;Lim Changyun;Yoon Junghee;Choi Mincheol
    • Journal of Veterinary Clinics
    • /
    • v.22 no.3
    • /
    • pp.186-189
    • /
    • 2005
  • For the assessment of the clinical application of histogram on internal parenchymal organs, ultrasonography with a multi-frequency transducer was taken. We scanned in the region of right cranial abdomen for both liver and right kidney, and left cranial abdomen for liver, spleen and left kidney in 9 normal Beagle dogs. The data from histogram examined in a region of interest centered on each picture element of B-mode images at the same depth were compared among liver, renal cortex, spleen, cortex and medulla of each kidney. The right renal cortex showed significantly lower echogenicity than parenchyma of liver by $15{\%}$. Spleen was more echogenic than the cortex of the left kidney by $23{\%}$, and liver was more echogenic than the left renal cortex by $30{\%}$. Renal cortex was more echogenic than medulla by $47{\%}$ and $65{\%}$ on the right and left side, respectively (p<0.05). The mean (${\pm}SD$) values calculated echogenicity were $46.2{\pm}12.3\;(95\%$ confidential interval (CI), 41.0 to 55.0) and $53.4{\pm}12.1\;(95\%$ CI, 47.0 to 55.1) in in the right renal cortex and liver parenchyma, $65.0{\pm}11.8\;(95\%$ CI, 57.9 to 71.0) and $51.0{\pm}16.9\;(95\%$ CI, 42.8 to 54.1) in splenic parenchyma and renal cortex. And the mean values calculated echogenicity were $65.0{\pm}10.15\;(95\%$ CI, 60.1 to 71.5) and $52.0{\pm}9.4\;(95\$ CI, 43.8 to 60.3) in liver parenchyma and the left renal cortex, $54.5{\pm}18.3\;(95\%$ CI, 40.1 to 62.8) and $35.0{\pm}16.2\;(95\%$ CI, 24.2 to 43.6) in the left renal cortex and medulla. And the mean values calculated echogenicity were $55.0{\pm}14.4\;(95\%$ CI, 47.3 to 61.7) and $40.0{\pm}13.2\;(95\%$ CI, 34.3 to 46.7) in the right renal cortex and medulla, respectively. In addition, the echogenicity ratios were $0.86{\pm}0.11$ between the right renal cortex and liver parenchyma, $1.37{\pm}0.47$ between spleenic parenchyma and the left renal cortex, $1.30{\pm}0.19$ between liver parenchyma and the left renal cortex. All the values measured showed significant different (p<0.05). Ultrasound histogram is simple, useful and feasible to evaluate the sonographic architecture of the internal organs such as liver, spleen and kidney, quantitatively.

An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound (효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현)

  • 박형재;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.516-519
    • /
    • 2001
  • To diagnose a patient's blood vessel disease, apoplexy, hypertension, arteriosclerosis, the blood velocity is very important. Determining the blood velocity methods using ultrasound are Continuous Doppler System and Pulse Doppler System. In using the Pulse Doppler System, we can obtain the position of blood velocity. But it is more complex hardware than Continuous Doppler System and it has low SNR(signal-noise ratio). So in this study, to obtain a believable information we use the Continuous Pulse Doppler System. Thus system have analog part and digital part. In analog part is composed of ultrasound generating part, the amplifying part to amplify the received signal from ultrasound sensor, the demodulation part to detect blood velocity and the filtering part to remove the noise. In digital part is composed of the A/D conversion part, digital signal processing part, and the communication part to communicate the PC. In this study to implement efficient ultrasound blood velocity measurement system, we can get the patient's blood velocity information in realtime. Thus, It is a useful in the accurate diagnosis with C.T(computered tomography), M.R.I(magnetic resonance imaging).

  • PDF

Incidental Extramammary Findings on Preoperative Breast MRI in Breast Cancer Patients: A Pictorial Essay (유방암 환자의 수술 전 유방 MRI에서 우연히 발견된 유방 외 소견: 임상화보)

  • Jin-A Ryoo;Shin Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.372-385
    • /
    • 2023
  • Breast cancer is one of the most common cancers and causes several complications in females. Currently, MRI is a necessary method for preoperative studies in patients with breast cancer. A high frequency of breast MRI can lead to an increase in the number of incidental extramammary findings. Moreover, it can provide accurate preoperative workup; therefore, the prognosis of patients can be improved. Herein, we provide several extramammary findings, including the mediastinum, lung, upper abdomen, bone, and soft tissue, correlating with US, chest CT, liver MRI, PET-CT, and bone scan.