• Title/Summary/Keyword: 간종양

Search Result 693, Processing Time 0.038 seconds

Commissionning of Dynamic Wedge Field Using Conventional Dosimetric Tools (선량 중첩 방식을 이용한 동적 배기 조사면의 특성 연구)

  • Yi Byong Yong;Nha Sang Kyun;Choi Eun Kyung;Kim Jong Hoon;Chang Hyesook;Kim Mi Hwa
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 1997
  • Purpose : To collect beam data for dynamic wedge fields using conventional measurement tools without the multi-detector system, such as the linear diode detectors or ionization chambers. Materials and Methods : The accelerator CL 2100 C/D has two photon energies of 6MV and 15MV with dynamic wedge an91es of 15o, 30o, 45o and 60o. Wedge transmission factors, percentage depth doses(PDD's) and dose Profiles were measured. The measurements for wedge transmission factors are performed for field sizes ranging from $4\times4cm^2\;to\;20\times20cm^2$ in 1-2cm steps. Various rectangular field sizes are also measured for each photon energy of 6MV and 15MV, with the combination of each dynamic wedge angle of 15o 30o. 45o and 60o. These factors are compared to the calculated wedge factors using STT(Segmented Treatment Table) value. PDD's are measured with the film and the chamber in water Phantom for fixed square field. Converting parameters for film data to chamber data could be obtained from this procedure. The PDD's for dynamic wedged fields could be obtained from film dosimetry by using the converting parameters without using ionization chamber. Dose profiles are obtained from interpolation and STT weighted superposition of data through selected asymmetric static field measurement using ionization chamber. Results : The measured values of wedge transmission factors show good agreement to the calculated values The wedge factors of rectangular fields for constant V-field were equal to those of square fields The differences between open fields' PDDs and those from dynamic fields are insignificant. Dose profiles from superposition method showed acceptable range of accuracy(maximum 2% error) when we compare to those from film dosimetry. Conclusion : The results from this superposition method showed that commissionning of dynamic wedge could be done with conventional dosimetric tools such as Point detector system and film dosimetry winthin maximum 2% error range of accuracy.

  • PDF

Subjective and Functional Results after a Proximal Gastrectomy: Prospective Study for Comparison of Reconstruction Procedures (근위부 위절제술 후 재건 술식에 따른 경과 관찰)

  • Kim, Ji-Hoon;Yook, Jeong-Hwan;Kim, Byung-Sik;Oh, Sung-Tae
    • Journal of Gastric Cancer
    • /
    • v.6 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: A proximal gastrectomy is performed for gastric cancer in the upper part of the stomach to preserve the function of the stomach after surgery. An esophagogastrostomy is one of the common reconstruction methods for a proximal gastrectomy, but this method results in a high incidence of reflux esophagitis. This study was undertaken to compare subjective and functional results between esophagogastrostomy and jejunal interposition reconstructions. Materials and Methods: From June 1998 to December 2002, proximal gastrectomies were performed in 33 patients with tumors in the upper third of the stomach; 8 had reconstruction using jejunal interposition between the esophagus and the remnant stomach (JI group) while 25 had reconstruction using esophagogastrostomy (EG group). The postroperative courses of the patients were reviewed in terms of symptoms, weight changes, and endoscopic findings. Results: The mean age of the patients was 59 years; 26 were men and 7 were women. There were no significant differences in general complications, operating times, or histologic features between the two groups. Fifty-two percent (52%) of the EG group complained of dysphagia, and 16% them experienced heartburn and acid belching. Twelve percent (12%) of the JI group complained of dysphagia, but heartburn and acid belching did not occur. Incidences of reflux esphagitis (36%) and balloon dilatation for anastomotic stricture (16%) were more common in the EG group than in the JI group (0% and 12%). Conclusion: To prevent or minimize complications, such as reflux esophagitis and postoperative symptoms, a proximal gastrectomy with a jejunal interposition is an alternative method as an organ-preserving surgical strategy to improve quality of life for patients. (J Korean Gastric Cancer Assoc 2006;6:1-5)

  • PDF

Comparative Analysis of Laparoscopy-assisted Gastrectomy versus Open Gastrectomy (복강경 보조 위절제술과 개복 위절제술의 비교 분석)

  • Lim, Jung Taek;Kim, Byung Sik;Jeong, Oh;Kim, Ji Hoon;Yook, Jeong Hwan;Oh, Sung Tae;Park, Kun Choon
    • Journal of Gastric Cancer
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • Purpose: There has been increased the number of early gastric cancer and laparoscopy-assisted gastrectomy (LAG), due to early detection through mass screening program. We started the LAG in April 2004 and performed 119 cases of gastric cancer in 2005, so we report a surgical outcome compared with that of open gastrectomy (OG). Materials and Methods: 119 patients underwent LAG in 2005, and for open group, 126 patiens of early gastric cancer were selected sequentially from January 2005 to March 2005. We compared clinicopathologic characteristics, postoperative courses and complications between two groups. Results: There was no significant difference between age, a length of hospital stay, distal resection margin and a number of retrived lymph nodes. The operation time was longer in LAG group (239.2 vs 123.3 mins, P<0.001) and a diet progression was faster in LAG group (first flatus: 3.05 vs 3.70 days, SOW: 2.86 vs 3.22 days, liquid diet: 3.87 vs 4.19 days, soft diet: 4.84 vs 5.26 days, P<0.001). But there was no difference statistically in postoperative discharge date (7.73 vs 8.25 days, P=0.229). The additional requirement of analgesic injection was less frequent in LAG group (2.97 vs 4.92 times, P<0.001). The harvested lymph nodes were similar in both groups (23.9 vs 23.1, P=0.563). A complication rate was lower in LAG group (4.9% vs 9.5%), but there was no statistical significance (P=0.179). There was no mortality in both groups and no conversion to open gastrectomy in the LAG group. Conclusion: LAG can be performed safely and accepted in view of curative procedure in treatment of early gastric cancer. But we need the follow up of long-term period to evaluate the survival rate and recurrence, and a prospective randomized controlled study should be done to establish that LAG will be a standard operation for early gastric cancer.

  • PDF

Scheduling Algorithms and Queueing Response Time Analysis of the UNIX Operating System (UNIX 운영체제에서의 스케줄링 법칙과 큐잉응답 시간 분석)

  • Im, Jong-Seol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.3
    • /
    • pp.367-379
    • /
    • 1994
  • This paper describes scheduling algorithms of the UNIX operating system and shows an analytical approach to approximate the average conditional response time for a process in the UNIX operating system. The average conditional response time is the average time between the submittal of a process requiring a certain amount of the CPU time and the completion of the process. The process scheduling algorithms in thr UNIX system are based on the priority service disciplines. That is, the behavior of a process is governed by the UNIX process schuduling algorithms that (ⅰ) the time-shared computer usage is obtained by allotting each request a quantum until it completes its required CPU time, (ⅱ) the nonpreemptive switching in system mode and the preemptive switching in user mode are applied to determine the quantum, (ⅲ) the first-come-first-serve discipline is applied within the same priority level, and (ⅳ) after completing an allotted quantum the process is placed at the end of either the runnable queue corresponding to its priority or the disk queue where it sleeps. These process scheduling algorithms create the round-robin effect in user mode. Using the round-robin effect and the preemptive switching, we approximate a process delay in user mode. Using the nonpreemptive switching, we approximate a process delay in system mode. We also consider a process delay due to the disk input and output operations. The average conditional response time is then obtained by approximating the total process delay. The results show an excellent response time for the processes requiring system time at the expense of the processes requiring user time.

  • PDF

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

Preservation of Subvalvular Apparatus During Mitral Valve Replacement (판막하부 구조물을 보존하는 인공 승모판막 치환술)

  • 임창영;임정철
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1329-1336
    • /
    • 1996
  • From January, 1994 to January. 1996, mitral valve replacement was performed in 27 patients. Among these, 17 patients underwent mitral valve replacement(MVR) with preservation of the annulo-papillary continuity(PAPCMVR) (-Group I), and 10 patients underwent conventional methods of excision of all the chordae(Group II). The operative technique for PAPCM VR consists of the division of the anterior leaflet into anterior and posterior segments, shifting and reattachment of the divided segments to the mitral ring of the respective commissural areas. This retrospective study has been designed to evalute the postoperative left ventricular function in the two groups. In the group 1, LVEF(Left Vnetricular Ejection Fraction : %) was 52 $\pm$ 3 preoperatively And 50$\pm$3 postoperatively, LVESI Vent icular End Systolic Volume Index/mL/m2) wIns 59 :6 and 51 $\pm$ 7, LVEDI Ventricular End Diastolic Volume Index/mL/m2) was 124$\pm$ 11 and 91 :8. In the group II, LVEF was 56$\pm$1 and 47:), LVESVI 62$\pm$12 and 61$\pm$15, LVEDVI 133$\pm$27 and 104$\pm$17. : the variation of the LVEF in these two group was statistically different(p(0.05). A comparison of left ventricular function data between Group I(n: 17) and Group II(n: 10) revealed better results in echocardiographic LVEF(p<0.05), LVEDVI(p<0.01) in the former group. The mean functional class(UYHA) was 2.6 preoperative and improved to 1.0 postoperatively In group 1, and 2.8 and to 1.0 in group II. We conclude that maintenance of continuity between the mitral annulus and papillary muscles is expected to have a beneficial effect on postoperative left ventricular performance.

  • PDF

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

Comparative Study of Cyclioxygenase-2 Expression and HER-2/neu Amplification in Korean and Caucasian Women with Early-Onset Breast Carcinoma (한국인과 백인 젊은 여성 유방암 환자에서 Cyclooxygenase-2 발현과 HER-2/neu 증폭의 비교 연구)

  • Choi, Doo-Ho;Kim, Eun-Seog;Kim, Yong-Ho;Jin, So-Young;Lee, Dong-Wha;Haffty, Bruce G.
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.307-315
    • /
    • 2004
  • Purpose: The purpose of this work was to study the differences of cyclooxygenase (COX-2) expression between Korean and Caucasian patients with early-onset breast carcinoma by immunohistochemistry. The test were analyzed to find a correlation between COX-2 and other biomarkers including HER-2/neu amplification, because we previously reported that a significant difference had been found in the expression of HER-2/neu between the two races. Furthermore, we investigated prognostic significance of COX-2 in korean patients. Materials and Methods: Sixty Korean women who were diagnosed breast carcinoma at 45 years old or younger and 60 Caucasian women with breast carcinoma were selected for this study. The median age of both groups was 37 years and tumor sizes were distributed evenly between the two group. Paraffin embedded blocks of primary tumor were processed for immunohistochemical staining of COX-2. The COX-2 expression was evaluated according to the percentage of positive cells and the intensity of staining. And the results were compared with the data of the previous studies to find correlation between COX-2 and other parameters and survival data. Results: Proportion of the COX-2 expression in total patients was $27.6\%$. The percentage of tumors that stained positive for COX-2 in korean and Caucasian women with early-onset breast carcinoma were $37.9\%$ and $20.8\%$, respectively. The difference was statistically not significant(p=0.090). Expression of COX-2 was not associated with several clinicopathologic parameters including HER-2/neu overexpression, but negative estrogen receptor status was correlated with significance (p=0.046). The 5 year disease free survival rate for patients with COX-2 expression was $67.9\%$, compared to $81.9\%$ of the COX-2 negative patients and the result was statistically not significant. Conclusions : A significant difference was not found in the expression of COX-2 between the two groups of patients with early-onset breast carcinoma. And correlation between COX-2 and other parameters was not observed except estrogen receptor negativity. Large scaled further research including radiotherapy factors will be needed to identify COX-2 as a prognostic role in patients with early-onset breast carcinoma.

Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF

Clinical Outcome of Multicystic Dysplastic Kidney in 46 Children (다낭성 이형성 신 환아 46명의 예후와 관련한 임상적 고찰)

  • Jeong Il-Cheon;Hwang You-Sik;Ahn Sun-Young;Han Sang-Won;Lee Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.10 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • Purpose : Conservative management of multicystic dysplastic kidney(MCDK) without nephrectomy has recently been advocated. The purpose of this study was to determine the clinical course of conservatively managed MCDK and to find out possible predictive factors for involution of MCDK by ultrasonography(US). Methods : A retrospective analysis was made on 45 patients(26 boys and 20 girls) in whom MCDK was detected and had been traced by US between Dec. 1993 and Aug. 2005 at Severance Hospital. Results : Median follow-up time was 30 months(range 2-102 months). All patients under-went radionuclide scans and voiding eystourethrograms. The serial follow-up US showed complete involution in 11(24%), partial involution in 19(41%), and no interval change or increased in cyst size in 13(28%) patients. Nephrectomy was done in 3 patients(7%) due to relapsing urinary tract infection(UTI) and severe abdominal distension. The mean age of complete involution of MCDK was 37 months(range 12-84 months). Episodes of UTI were present in 17 patients(37%) and additional genitourinary(GU) abnormalities were found in 22 patients(44%). Hypertension and renal insufficiency was complicated in one patient. No child developed malignant tumor. Univariate analysis showed that five variables were associated with complete involution of the MCDK; gender, site, UTI episode, additional GU abnormalities, and renal length on initial US. After adjusting using the Pearson model, the presence of additional GU abnormalities was exclusively associated with complete involution among the 5 variables(P=0.034). Conclusion : In our review of 46 cases of MCDK, non-surgical approach for patients with MCDK was advisable and we could predict poor prognosis when MCDK is associated with other GU anomalies.

  • PDF