• Title/Summary/Keyword: 간접 측정

Search Result 1,017, Processing Time 0.039 seconds

A Study on Intrinsic Noise of Capacitively Coupled Active Electrode (용량성 결합 능동 전극의 내부 잡음 분석)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily Life. This study is the first step to reducing the large background noise appearing in indirect-contact ECG. This study built the thermal noise model of capacitively coupled active electrode which is used in indirect-contact ECG. The results show that the level of thermal noise estimated by the thermal noise model is much the same as that of actual background noise for the capacitively coupled active electrode alone. By applying the actual electrical properties of a sample cotton cloth to the thermal noise model, the theoretical level of thermal noise in the indirect-contact ECG was estimated. The results also show that the level of op-amp's intrinsic noise is so small that it can be negligible in comparison with thermal noise of resistors. The relationship between the level of thermal noise and the resistance of the bias resistor was derived, and it is the base for the further study how to choice the optimal resistance for the bias resistor.

Validity and Reliability for the Use of Program Outcome Indirect Measurement Tool in Korean Nursing Baccalaureate Education (간호교육 프로그램 학습성과 간접측정도구의 활용을 위한 신뢰도 및 타당도 검증)

  • Song, Mi Ok;Kim, Heeyoung
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.8
    • /
    • pp.608-618
    • /
    • 2021
  • The aim of this study was to verify the feasibility and reliability of the program outcome indirect measurement tool developed for nursing college students in Korean. 396 nursing students from 5 nursing colleges participated in this study, data were collected from November 22 to December 10, 2019. Data analysis was conducted using the IBM Statistics SPSS 21.0 and AMOS 21.0 programs to analyze item analysis, exploratory and confirmatory factor analysis. As a result of the item analysis, all 79 items were selected for factor analysis. In the exploratory factor analysis, five items that were loaded with other factors were deleted. The final factor loading range was from .37 to .86, and the cumulative explanatory variance for 12 factors was 71.71%. No items were deleted as a result of the confirmatory factor analysis, and the final scale was consisted of 74 items. The average score for scale was 3.78 and Cronbach' α was .98. The feasibility and reliability of the program outcome indirect measurement tool have been verified through this study. Therefore it can be used as a more standardized indirect measurement tool for nursing college students.

Agreement and Digit Preference of Blood Pressure Measurements Between pairs of Random-Zero Sphygmomanometer, Digit Automatic Device and Regular Mercury Sphygmomanometer on Hypertensive Urban Young African-American Men (도시지역 고혈압을 가진 젊은 흑인 남성들의 Random-Zero Sphygmomanometer, Digit Automatic Device 와 Regular Mercury Spygmomanometer 사이의 혈압측정 방법에 의한 일치도와 점(숫자)선호도)

  • Park, Kyung-Min
    • Research in Community and Public Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.170-177
    • /
    • 1996
  • 신체의 활력을 측정하는 혈압은 다른 어느 측정치보다 변동이 심하고 정상적으로 변할 수 있는 생리적 현상이어서 정확하게 측정하기란 쉽지 않다. 1mmHg 차이의 혈압일지라도, 특히 큰 집단일 경우, 연구목적에서 그 결과를 크게 왜곡 시킬 수 있다. (Wright & dore, 1970). 혈압 측정에는 직접적 방법과 간접적 방법이 있다. 이 중 간접적 방법은 임상분야와 연구분야에서 실제로 넓게 사용되고 있을 분만 아니라 신체로의 직접적 침투하는 방법도 아니고 가격 또한 비싸지 않다. 그러나, 간접적 측정 방법은 혈압에 영향을 끼치는 많은 요인들인 관찰자 편견, 확장기음의 청취음 선택, 관찰자와 환자 사이의 상호관계 때문에 방법론적으로 문제제기가 되기도 한다. 이런 요인을 최소화하기 위하여 가장 타당도가 높은 측정도구의 선택이 필요하다. 도시지역의(Ease Baltimore) 고혈압을 가진 젊은 흑인 남성(연령별/성별/종속별/거주지역) 중 수축기 혈압이 140mmHg 이고 확장기 혈압이 90mmHg인 사람, 또는 확장기 혈압이 90mmHg인 사람, 또는 혈압하강제를 먹고 있는 사람 200명을 대상으로 훈련받은 community health worker(CHW)에 의해 Random-Zero Sphygmdmanometer(RZS)와 Digit Automatic Device(DAD)로 혈압을 측정하게 하였다. 이 중 36명을 무작위 추출하여 regular Mercury Sphygmdmanometer (RMS)로 혈압을 측정하게 했다. Bland 와 Altman에 의해 제기된 두측정값의 차이에 대한 scattergram(일치도 검증법)과 AAMI(Association for the Advancement of Medical Instrument) 기준, BHS 기준, Central Tendency와 숫자선호도로 검증되었다. AAMI와 BHS 기준에 의하면 확장기 혈압에서 RZS와 DAD의 일치도와 평균을 중심으로 더 넓게 퍼져있어 낮은 일치도를 보였으며 또 DAD와 RMS의 혈압치는 숫자 선호도를 볼 수 있는데 특히 RMS는 더 뚜렷하게 나타났는데 확장기 혈압의 최빈치(30.6)는 100mmHg이었다. 혈압치들이 가장 가까이 "0"점으로 치우쳐져 있었다. RZS의 Central tendency는 DAD와 RMS보다 뚜렷하였다. 결론적으로 RZS는 이 연구목적으로 가장 적절함을 보여준다.

  • PDF

Air-tightness Test by Silicagel on Museum Cases (조습제(燥濕濟)(Art-Sorb)를 이용한 벽부형진열장(壁附形陳列欌) 밀폐도(密閉度) 간접측정(間接測淀))

  • Yu, Hei-sun;Kim, Myoung-nam;Lee, Sung-eun
    • Conservation Science in Museum
    • /
    • v.3
    • /
    • pp.71-78
    • /
    • 2001
  • The airtightness of museum cases in museums was measured by using CO2 tracing gas, but it has been pointed that it has a problem with measuring the airtightness of a museum case which has a hole inside before it is used or while is being used. So studies tried to come up with alternatives which make it possible to measure the airtightness of a museum case before it is used or while it is being used if necessary by indirectly measuring the airtightness of the museum case without changing its form. Indirect measuring is done by measuring the change of Art-sorb weight and the change of temperature and humidity inside the museum case. Experiments were made for 12 days with three builtin wall case installed at the same place without turning on the lights but with Art-sorb and the data logger of temperature and humidity put into museum case. The change rate was produced with the change of temperature and humidity inside the museum case divided by that of those around museum case. As a result, the temperature change rate of museum case A(0.67) was lower than that of museum case B(0.69) or museum case C(0.79). The humidity change rate of museum case A(0.12) was lower than that of museum case B(0.19) or museum case C(0.72) showing that its airtightness was the best. Also in the direct airtightness measurement by CO2 tracing gas, the air exchange rate was compared with the humidity change rate by Art-sorb in the indirect measurement.

우주거리척도(Cosmic Distance Scale)로 사용되는 식쌍성 I. 알골형 식쌍성을 이용하여 측정한 거리

  • 홍경수;강영운
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.23-23
    • /
    • 2003
  • 천체의 거리는 다양한안 방법을 사용하여 직접 혹 간접적으로 측정되어왔다. 특히 우주배경복사를 측정하는 인공위성 관측의 정밀도가 혁명적으로 향상됨에 따라 우주의 나이는 수 % 이내의 정밀도로 결정할 수 있는 수준으로 발전하였다. 우주의 규모가 구체적으로 정의되는 가운데 우주의 절대적인 크기를 제시하기 위하여 천체의 거리를 측정하는데 사용되는 표준등불로 세페이드 변광성 이외에 식쌍성이 새롭게 대두되었다. 이 논문에서는 식쌍성이 거리척도의 표준등불이 될 수 잇는지 검증하기 위하여 광도곡선과 시선속도곡선이 잘 알려진 알골형 쌍성 식쌍성 RY Aqr, RX Gem, RS Vul을 선정하여 거리를 산출하였다. 별을 선정한 기준은 2색 이상의 광도곡선이 발표되고, 이중 분광쌍성으로 시선속도곡선이 각 성분별로 잘 관측되어 발표되고, IUE 관측 자료가 있는 알골형 쌍성이다. 거리 산출과정에서 간접적으로 유추하여 얻는 인자를 줄이기 위하여, 광도곡선으로부터 별의 상대적인 크기를 구하고, 시선속도곡선으로부터 공전궤도의 장반경을 구하고, 별의 에너지 분포 곡선으로부터 별의 온도를 측정하였다. 위 3종류의 관측 결과를 종합하여 식쌍성의 물리적 인자와 거리를 구하였다. 이와 같은 방법으로 구한 거리는 히파크러스를 이용하여 관측한 시차와 비교하였다.

  • PDF

A Studies on Indirect Photometric Detection of Aliphatic Compounds by High-Performance Liquid Chromatography (고성능 액체 크로마토그래피에 의한 지방족 화합물의 간접 분광광도 측정에 관한 연구)

  • Sam-Woo Kang;Jeon-Tag Kang
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.406-412
    • /
    • 1989
  • Indirect photometric detection of aliphatic compounds such as alcohols, ketones and esters was investigated in high-performance liquid chromatography, These samples possessing nonchromophore or weak chromophore could be indirectly detected by a UV detector with addition of UV absorbing, p-chlorophenol or p-nitrophenol in mobile phase as detection reagent, and submicrogram detection limits were achieved. Some mixtures of samples were also able to be separated and quantitated with good resolution and comparatively high sensitivity under optimum conditions.

  • PDF

환자에서의 젖산 측정

  • Seo, Ji-Min
    • Journal of the korean veterinary medical association
    • /
    • v.43 no.12
    • /
    • pp.1113-1118
    • /
    • 2007
  • 중환자에서 조직의 저산소증을 확인하고 교정하는 것은 매우 중요하다. 혈중 젖산측정은 30년 이상 인의에서 조직의 산소화를 위한 간접적인 측정방법으로 이용되었다. 그러나 수의에서는 최근에 많이 이용되고 있는 방법이다. 비싸지 않은 간이 젖산 측정계로 중환자의 젖산을 연속적으로 모니터하는 것이 수의 응급실 및 전문병원(referral center)에서 상용화되고 있다. 수의 환자에서 혈중 젖산 측정은 질병의 심각도를 결정하고 치료 결정을 조절하는데 유용한 보조 수단이다.

  • PDF

A Study on Shear Stress Distribution in a Open Channel (개수로에서의 바닥전단응력 분포 분석)

  • Kim, Min Gyu;Kang, Kimchhun;Oh, Jun Oh;Park, Jae Hyeon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.445-445
    • /
    • 2016
  • 급변하는 개수로 흐름에서 발생하는 바닥전단응력의 분포는 하천구조물 설계에 있어 매우 중요한 요소이다. 하천 구조물 중 호안에 대한 하천설계기준 '설계편 제 24장 호안'에는 호안 설계에 대한 일반적인 사항이 제시 되어 있으나, 구체적인 소류력 또는 유속에 대한 기준, 각 호안공법들의 안정성을 평가하기 위한 시험법 등에 대한 구체적인 기준이 부족한 상황이다. 소류력 측정방법에는 간접측정법과 직접측정법이 있다. 간접측정법에는 Reach-Average공식, Reynolds Stress, TKE공식 (Turbulent Kinetic Energy)이 있고 직접측정법에는 Shear Meter, Preston Tube 등이 있다. 본 연구에서는 바닥전단응력을 직접 측정할 수 있는 1차원 소류력 측정장치를 개발하고, 최대유속 5m/s 가변형 고속수로 실험을 통하여 Reach-Average 공식, Reynolds Stress, TKE 공식으로 산정한 바닥전단응력 값과 1차원 소류력 측정장치 값을 비교 분석하였다. 실험케이스는 총 3개로, 22.42???, 30.00???, 41.00??? 유량을 사류이면서 난류인 상태로 실험을 수행하였다. 분석 결과, 본 연구에서 개발한 1차원 소류력 측정장치의 측정값은 TKE공식과 약 2.3% 차이가 났으며, Reach-Average공식과 약 8.1%, Reynolds Stress는 약 22.1% 차이가 났다. 즉, 본 연구에서 개발한 1차원 소류력 측정장치는 유속 범위(1m/s ~1.6m/s )에서 TKE공식을 이용한 바닥전단 응력과 가장 근사하게 나타나는 것으로 분석되었다.

  • PDF

An Approach to Measure Anthropometric Data of Simulated Human Hand Using Photogrammetry (시뮬레이션 환경에서 사진측량기법을 이용한 손 치수 측정 방법에 대한 연구)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.5
    • /
    • pp.511-517
    • /
    • 2016
  • Anthropometric data of the hand is one of the important issues for the product design related with hand and manual operation in terms of user-centered design. Direct measurement, which traditionally uses anthropometric measuring tool, has a few disadvantages in cumulation of measuring time, possible errors in raw data, doubtful reliability between inspectors. Newly introduced 3D scanning technology overcomes those disadvantages; however, another disadvantages, such as, hight cost and immovability, have been introduced. In this study, photogrammetric approach was introduced for the measurement of anthropometric data in hand. In order to minimize the possibility of error during direct and indirect measurement, a simulated object was used and effectiveness of photogrametric measurement was confirmed for the collection of anthropometric data in hand.

Development of an High Speed Detector System for Radiation (방사선원 검출용 고속 탐지기 개발)

  • Lee, Seung-Min;Lee, Hyo-Sung;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.121-123
    • /
    • 2007
  • 광변환 물질을 사용하여 X-선이나 감마방사선을 가시 광으로 변환한 다음 CCD 카메라를 통하여 광량을 측정하면 방사선의 양을 간접적으로 측정할 수 있다. 본 연구에서는 CCD형 비상대응 로봇용 고속 삼차원 방사선 위치 탐지장치에서 방사선 위치 센싱의 핵심 역할을 수행하는 CCD 방사선 탐지부를 간접 방사선 측정 방법을 응용하여 고안하고 구현한 다음 이에 대한 방사선 특성시험 및 거리측정을 수행하였다. 시험 결과로부터 구현한 CCD형 방사선 센서가 방사선 위치 및 선량 탐지장치로 활용 가능성이 충분함 확인하였다.

  • PDF